Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 72
Filter
1.
J Arrhythm ; 40(2): 363-373, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38586857

ABSTRACT

Background: The precise details of atrial activation around the triangle of Koch (ToK) remain unknown. We evaluated the relationship between the atrial-activation pattern around the ToK and success sites for slow-pathway (SP) modification ablation in slow-fast atrioventricular reentrant tachycardia (AVNRT). Methods: Thirty patients with slow-fast AVNRT who underwent successful ablation were enrolled. Atrial activation around the ToK during sinus rhythm was investigated using ultra-high-density mapping pre-ablation. The relationships among features of atrial-activation pattern and success sites were examined. Results: Of 30 patients (22 cryoablation; 8 radiofrequency ablation), 26 patients had a collision site of two wavefronts of delayed atrial activation within ToK, indicating a success site. The activation-search function of Lumipoint software, which highlights only atrial activation with a spatiotemporal consistency, showed non-highlighted area on the tricuspid-annulus side of ToK. In 23 of the patients, a spiky potential was recorded at that collision site outside the Lumipoint-highlighted area. Fifteen cryoablation patients with a success site coincident with a collision site outside the Lumipoint-highlighted area had significantly more frequent disappearances of SP after initial cryoablation (46.7% vs. 0%, p = .029), fewer cryoablations (3.7 ± 1.8 vs. 5.3 ± 1.3, p = .045), and shorter procedure times (170 ± 57 vs. 228 ± 91 min, p = .082) compared to the seven cryoablation patients without such sites. Four patients had transient AV block by ablation inside the Lumipoint-highlighted area with fractionated signals, but no patient developed permanent AV block or recurrence post-procedure (median follow-up: 375 days). Conclusions: SP modification ablation at the collision site of atrial activation of the tricuspid-annulus side along with a spiky potential could provide a better outcome.

2.
Hypertens Res ; 47(6): 1688-1696, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38532036

ABSTRACT

Lack of the typical nocturnal blood pressure (BP) fall, i.e non-dipper, has been known as a cardiovascular risk. However, the influence of non-dipper on atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) has been unclear. We investigated the clinical impact of non-dipping as evaluated by 24-hour ambulatory BP monitoring on the long-term outcome of AF recurrence post-PVI in 76 AF patients with a history of increased BP. The PVI procedure was successful in all 76 patients (mean age, 66±9years; antihypertensive medication, 89%; non-paroxysmal AF, 24%). Twenty patients had AF recurrence during a median follow-up of 1138 days. There was no difference in BP levels between the AF recurrence and non-recurrence groups (average 24 h systolic BP:126 ± 17 vs.125 ± 14 mmHg; P = 0.84). On the other hand, the patients with non-dipper had a higher AF recurrence than those with dipper (38.9% vs.15.0%; P = 0.018). In Cox hazard analysis adjusted by age, non-paroxysmal AF and average 24-hr systolic BP level, the non-dipper was an independent predictor of AF recurrence (HR 2.78 [95%CI:1.05-7.34], P = 0.039). Non-dipper patients had a larger left atrial (LA) volume index than the dipper patients (45.9 ± 17.3 vs.38.3 ± 10.2 ml/m2, P = 0.037). Among the 58 patients who underwent high-density voltage mapping in LA, 11 patients had a low-voltage area (LVA) defined as an area with a bipolar voltage < 0.5 mV. However, there was no association of LVA with non-dipper or dipper (22.2% vs.16.1%, P = 0.555). Non-dipper is an independent predictor of AF recurrence post-PVI. Management of abnormal diurnal BP variation post-PVI may be important.


Subject(s)
Atrial Fibrillation , Blood Pressure Monitoring, Ambulatory , Blood Pressure , Circadian Rhythm , Pulmonary Veins , Recurrence , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Aged , Middle Aged , Blood Pressure/physiology , Circadian Rhythm/physiology , Catheter Ablation , Treatment Outcome
4.
Intern Med ; 2023 Oct 06.
Article in English | MEDLINE | ID: mdl-37813617

ABSTRACT

Pulmonary vein stenosis (PVS) is a serious complication of catheter ablation (CA) for atrial fibrillation (AF). PVS generally occurs several months after CA and presents with non-specific symptoms and imaging findings. There have been reports of delayed diagnoses due to a misdiagnosis as infection, interstitial pneumonia, or organizing pneumonia. We introduced six cases of PVS after CA, all of which showed narrowing of the unilateral pulmonary vessels with or without lobar volume loss in the left lung on unenhanced computed tomography. We report these findings as important results indicating the possibility of PVS after CA for AF and contributing to the early diagnosis and management of PVS.

5.
J Arrhythm ; 39(4): 574-579, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37560274

ABSTRACT

Background: While most VVI pacemakers in bradycardic patients are set to a low limit of 60/min, the optimal lower limit rate for VVI pacemakers in atrial fibrillation has not been established. Although an increase in heart rate within the normal range in the setting of a VVI pacemaker might be expected to lead to an increase in cardiac output with the shortening of the diastolic time, the changes in cardiac output at different pacemaker settings have not been fully clarified. Methods: We included 11 patients with bradycardic atrial fibrillation who had VVI pacemakers implanted. Stroke volume was measured using the electrical cardiometry method (AESCULONⓇ mini; Osypka Medical) without pacing and at ventricular pacings of 60, 70, 80, and 90/min. Results: Stroke volume decreased stepwise at ventricular pacing rates of 60, 70, 80, and 90/min (63.6 ± 11.2, 61.9 ± 10.6, 59.3 ± 12.2, and 57.5 ± 12.2 mL, p < .001), but cardiac output increased (3.81 ± 0.67, 4.33 ± 0.74, 4.74 ± 0.97, and 5.17 ± 1.09 L/min, p < .001). The rate of increase in cardiac output at a pacing rate of 70/min compared to 60/min correlated with left ventricular end-systolic volume (r = 0.711, p = .014). Conclusions: Cardiac output increased at a pacing rate of 70 compared to 60 in bradycardic atrial fibrillation patients, and the rate of increase in cardiac output was greater in those with larger left ventricular end-systolic volume.

6.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37539865

ABSTRACT

AIMS: The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. METHODS AND RESULTS: Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). CONCLUSION: Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Atrial Appendage/surgery , Tachycardia/etiology , Tomography, X-Ray Computed , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
7.
J Cardiovasc Electrophysiol ; 34(4): 849-859, 2023 04.
Article in English | MEDLINE | ID: mdl-36738145

ABSTRACT

INTRODUCTION: Beyond pulmonary vein isolation (PVI), additional therapeutic strategies for atrial fibrillation (AF) have not been established. Remodeling of the left atrium (LA) could impact AF recurrence post-PVI. We investigated the impact of unipolar voltage (UV) criteria for the LA posterior wall (LA-PW) on AF recurrence post-PVI. METHODS: We reviewed the cases of 106 AF patients (mean age 63.8 years, nonparoxysmal AF: 59%) who underwent extensive encircling PVI by radiofrequency ablation guided by a 3-dimension mapping system, investigating the impact on AF recurrence of the UV criteria of the LA. RESULTS: Out of all patients, 26 patients had AF recurrence during post-PVI follow-up [median 603 days]. They showed a higher percentage of nonparoxysmal AF (80.8 vs. 52.5%, p = .011), longer AF duration (2.9 ± 2.7 vs. 1.0 ± 1.7 years, p = .002), and larger area size of UV < 2.0 mV in LA-PW (2.8 ± 1.8 vs. 1.0 ± 1.5 cm2 , p < .001) than those without recurrence. Cox Hazard analysis for AF recurrence adjusted by age, gender, AF duration, body mass index and left atrial volume index revealed that an area size over 2.0 cm2 of UV < 2.0 mV in LA-PW (HR 6.9 [95% CI:1.3-35.5], p = .021) posed independent risks for AF recurrence post-PVI. The atrial arrhythmia-free survival rate was higher in those with no area of UV < 3.0 mV in LA-PW compared to those with a sizable area (>2.0 cm2 ) of UV < 3.0 mV and <2.0 mV (95.0% vs. 74.2% vs. 57.1%, Log-Rank: p < .001). In the AF etiology of patients with AF recurrence, 9 of 14 patients who underwent the 2nd procedure had no PV reconnection, and 8 patients required the LA-PW isolation for their non-PV AF. CONCLUSION: UV criteria of LA-PW is a useful parameter for AF-recurrence post-PVI. Lower UV in LA-PW as an indication of electrical remodeling could indicate a higher risk of AF recurrence and the need for further therapeutic strategies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Middle Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria , Pulmonary Veins/surgery , Treatment Outcome , Retrospective Studies
8.
Europace ; 25(2): 374-381, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36414239

ABSTRACT

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods , Phrenic Nerve , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
9.
J Electrocardiol ; 75: 44-51, 2022.
Article in English | MEDLINE | ID: mdl-36306606

ABSTRACT

PURPOSE: Cryoablation is a safe alternative to radiofrequency (RF) ablation for slow-fast atrioventricular reentrant tachycardia (AVNRT); however, optimal electrogram parameters for site selection remain unknown. We retrospectively investigated local electrograms for slow pathway (SP) modification in cryoablation. METHODS: Forty-five consecutive patients with slow-fast AVNRT who underwent cryoablation using a 6-mm-tip catheter were enrolled. Electrogram parameters for sites of successful SP modification (success-sites) were investigated; these included the interval between atrial activation at His and the last deflection of SP potential, defined as the His(A)-SPP interval. In 8 patients, 3-dimensional mapping by multi-electrode catheter was performed pre-ablation for more detailed SP assessment. RESULTS: Twenty-seven of 45 patients had successful SP modification by 1 cycle of freeze-thaw-freeze cryoablation at a single site with a low amplitude and fragmented SP potential. Among a total of 76 cryoablation sites in all patients, the His(A)-SPP interval at success-sites (45 sites) was significantly longer than that at unsuccess-sites (31 sites) (86 ± 9 vs.78 ± 10 msec, p < 0.0001). The AV amplitude ratio was not significantly different between success-and unsuccess-sites (0.21 ± 0.22 vs.0.25 ± 0.23, p = 0.429). The cutoff value of the His(A)-SPP interval for successful cryoablation was 82 msec with a sensitivity of 0.67 and specificity of 0.71 (AUC: 0.739; 95%CI: 0.626-0.852; p < 0.0001). Three-dimensional mapping in all 8 patients showed that sites with the most delayed atrial activation and the last deflection of the fragmented SP potential within the Koch's triangle coincided with success-sites. CONCLUSION: A longer His(A)-SPP interval and fractionated SP potential were characteristics of successful cryoablation for SP modification in slow-fast AVNRT.


Subject(s)
Catheter Ablation , Cryosurgery , Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Humans , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/surgery , Retrospective Studies , Electrocardiography , Catheter Ablation/methods , Treatment Outcome
10.
Int Heart J ; 63(2): 241-246, 2022.
Article in English | MEDLINE | ID: mdl-35354746

ABSTRACT

There are no studies examining interventricular (VV) delay optimization by an electrical cardiometry method in relation to subsequent cardiac function in cardiac resynchronization therapy (CRT) -implanted patients. This study aimed to compare the VV delay in CRT-implanted patients by the dp/dt and electrical cardiometry and to examine the optimization of VV delay and improvement of cardiac function. We examined 19 consecutive CRT-implanted patients. The protocol included biventricular stimulation with either simultaneous or sequential pacing, and we evaluated systolic volume (SV) using an electrical cardiometry and the dp/dt of the left ventricle. The optimal VV delay was determined by the maximum SV using the electrical cardiometry. Two groups were defined, those whose increase in SV was at or above the median and those whose SV increase was below the median; changes in left ventricular ejection fraction (LVEF). The correlation between the VV delay optimized by the electrical cardiometry and dp/dt methods was high (R = 0.61, P = 0.006). Compared to the baseline SV (43.4 mL), the SV increased to 47.8 mL with simultaneous biventricular pacing (versus baseline P = 0.008) and further increased to 49.8 mL with optimized VV delay (versus simultaneous biventricular pacing P = 0.020). LVEF after 6 months significantly improved in the above-median SV increase group (37.6 versus 28.2%, P = 0.041), but not in the below-median SV increase group (26.5 versus 26.5%, P = 0.985). In conclusion, the optimal VV delay by electrical cardiometry method was almost concordant with that by the dp/dt method. Cardiac function significantly improved in the group with the above-median SV increase.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cardiac Resynchronization Therapy/methods , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Stroke Volume/physiology , Systole , Ventricular Function, Left
11.
BMC Cardiovasc Disord ; 22(1): 14, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35067224

ABSTRACT

PURPOSE: The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). METHODS: We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20-35 W) in 73 patients (Conventional group) and using the HP-SD setting (45-50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. RESULTS: The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. CONCLUSION: The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Conduction System/physiopathology , Heart Rate/physiology , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Electrocardiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Time Factors , Treatment Outcome
12.
Circ Arrhythm Electrophysiol ; 15(1): e010516, 2022 01.
Article in English | MEDLINE | ID: mdl-34962134

ABSTRACT

BACKGROUND: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. METHODS: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. RESULTS: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. CONCLUSIONS: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Iatrogenic Disease , Peripheral Nerve Injuries/epidemiology , Phrenic Nerve/injuries , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Peripheral Nerve Injuries/diagnosis , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
13.
J Interv Card Electrophysiol ; 63(1): 115-123, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33564988

ABSTRACT

PURPOSE: To elucidate the electrophysiological predictors of the intramural origins of left ventricular outflow tract-ventricular tachyarrhythmias (LVOT-VAs), and to clarify the involvement of anatomical factors. METHODS: Twenty-nine successfully ablated LVOT-VAs patients with origins in the aortomitral continuity (AMC) (n = 8), aortic sinus of valsalva (ASV) (n = 9), great cardiac vein (GCV) (n = 5), and intramural myocardium (n = 7) were enrolled. Intramural origins were defined as when effective ablation from AMC and epicardium (ASV and/or GCV) was needed. The local activation time difference (LATD) was calculated as follows: (earliest AMC activation) - (earliest epicardial activation), and was presented as an absolute value. Electrophysiological parameters and anatomical factors predisposing the intramural origins were investigated. RESULTS: LATD of intramural origins was significantly shorter than that of AMC and GCV (4.5 ± 2.6 vs. 12.1 ± 7.4 vs. 17.4 ± 4.7, P < 0.05), respectively. In multivariate logistic regression analysis, LATD was associated with intramural origins (odds ratio: 0.711, confidence interval: 0.514-0.985, P = 0.040). ROC analysis revealed LATD of 7 ms as cut-off value. In computed tomography analysis, some patients who had thick fat tissue below the GCV, and an unusual GCV running pattern might be misdiagnosed as intramural origins. CONCLUSION: LATD ≤ 7 ms was associated with intramural origins, but with some anatomical limitations.


Subject(s)
Catheter Ablation , Coronary Sinus , Tachycardia, Ventricular , Electrocardiography , Heart Ventricles/surgery , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery
15.
Circ Rep ; 3(4): 187-193, 2021 Mar 18.
Article in English | MEDLINE | ID: mdl-33842723

ABSTRACT

Background: The impact of preprocedural visit-to-visit blood pressure variability (BPV) on pulmonary vein isolation (PVI) outcome in patients with hypertension (HTN) and atrial fibrillation (AF) remains unclear. Methods and Results: This study enrolled 138 AF patients with HTN who underwent successful PVI. Patients were classified into 2 groups, those with AF recurrence (AF-Rec; n=42) and those without AF recurrence (No-AF-Rec; n=96). Blood pressure (BP) was measured at least 3 times during sinus rhythm, and systolic and diastolic BPV (Sys-BPV and Dia-BPV, respectively) were defined as the standard deviation of BP. Clinical characteristics were compared between the 2 groups, and the relationship between BPV and AF recurrence was investigated. Sys-BPV and Dia-BPV were significantly higher in the AF-Rec than No-AF-Rec group (Sys-BPV: 10.6±3.7 vs. 6.9±3.5; Dia-BPV: 7.3±3.1 vs. 4.8±3.0; P<0.05 for both). Receiver operating characteristic analysis revealed Sys-BPV 9.1 and Dia-BPV 5.7 as cut-off values for AF recurrence. Kaplan-Meyer analysis demonstrated higher AF recurrence in patients with Sys-BPV >9.1 and Dia-BPV >5.7 (P<0.05 for both). Cox multivariate regression analysis revealed that Sys-BPV >9.1 and Dia-BPV >5.7 were independent predictors of AF recurrence (hazard ratios 3.736 and 2.958, respectively; P<0.05 for both). Conclusions: Sys-BPV and Dia-BPV were associated with AF recurrence in AF patients with HTN.

16.
Intern Med ; 60(13): 2085-2088, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-33518575

ABSTRACT

We herein report a rare case of long QT syndrome (LQTS) coexisting with acetylcholine (Ach)-induced vasospasm. A 31-year-old woman experienced cardiopulmonary arrest during running. LQTS was diagnosed by an electrocardiogram, and the coexistence of Ach-induced vasospam was determined by an Ach provocation test on coronary angiography. Although an implantable cardioverter defibrillator was placed, a beta-blocker was not prescribed for two reasons: first, the patient showed Ach-induced vasospasm alone with no symptoms and no ST change by Ach injection, and second, the use of beta-blockers alone in such patients carries a risk of vasospasm-induced ventricular fibrillation.


Subject(s)
Coronary Vasospasm , Long QT Syndrome , Acetylcholine , Adult , Coronary Angiography , Coronary Vasospasm/chemically induced , Coronary Vasospasm/complications , Coronary Vasospasm/diagnosis , Electrocardiography , Female , Humans , Long QT Syndrome/chemically induced , Long QT Syndrome/diagnosis
17.
Circ Arrhythm Electrophysiol ; 13(10): e008602, 2020 10.
Article in English | MEDLINE | ID: mdl-32915644

ABSTRACT

BACKGROUND: The mechanism of esophageal thermal injury (ETI; esophageal mucosal injury and periesophageal nerve injury leading to gastric hypomotility) remains unknown when using a high-power short-duration (HP-SD) setting. This study sought to evaluate the characteristics of esophageal injuries in atrial fibrillation ablation using a HP-SD setting. METHODS: After exclusion of 5 patients with their esophagus at the right portion of left atrium and 21 patients with additional ablations such as box isolation and low voltage area ablation in left atrium posterior wall, 271 consecutive patients (62±10 years, 56 women) who underwent pulmonary vein isolation by radiofrequency catheter ablation were analyzed. In the 101 patients, a HP-SD setting at 45 to 50 W with an Ablation Index module was used (HP-SD group). In the remaining 170 patients before introduction of the HP-SD setting, a conventional power setting of 20 to 30 W with contact force monitoring was used (conventional group). We performed esophagogastroduodenoscopy after pulmonary vein isolation in all patients and investigated the incidence and characteristics of ETI. RESULTS: Although the incidence of ETI was significantly higher in the HP-SD group compared with the conventional group (37% versus 22%, P=0.011), the prevalence of esophageal lesions did not differ between the groups (7% versus 8%). Multivariate logistic regression analysis revealed that the use of the HP-SD setting (odds ratio, 6.09, P<0.001), and the parameters that suggest anatomic proximity surrounding the esophagus, were independent predictors of ETI. However, the majority of ETI in the HP-SD group was gastric hypomotility, and the thermal injury was limited to the shallow layer of the periesophageal wall using the HP-SD setting. CONCLUSIONS: Although the use of the HP-SD setting was a strong predictor of ETI, it could avoid deeper thermal injuries that reach the esophageal mucosal layer.


Subject(s)
Atrial Fibrillation/surgery , Burns, Electric/pathology , Catheter Ablation/adverse effects , Esophagus/pathology , Pulmonary Veins/surgery , Aged , Burns, Electric/epidemiology , Endoscopy, Digestive System , Esophagus/injuries , Female , Humans , Incidence , Male , Middle Aged , Prevalence , Risk Assessment , Risk Factors , Treatment Outcome
18.
J Arrhythm ; 36(1): 134-142, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32071632

ABSTRACT

BACKGROUND: The clinical significance of premature ventricular complexes (PVCs) in heart failure (HF) remains unclear. We aimed to clarify the associations of PVC burden with re-hospitalization and cardiac death in HF patients. METHODS: We studied 435 HF patients (271 men, mean age 65 years). All patients were hospitalized for worsening HF. After optimal medications, echocardiography, 24 hours Holter monitoring and cardiopulmonary exercise testing were performed before discharge. The clinical characteristics and outcomes of the HF patients were investigated. RESULTS: During a median follow-up period of 2.3 years, there were 125 (28.7%) cardiac events (re-hospitalization due to worsening HF, fatal arrhythmias, or cardiac death). The patients with cardiac events had higher PVC burden compared to those without (median 0.374%/d [interquartile range 0.013-1.510] vs median 0.026%/d [interquartile range 0.000-0.534], P < .001). We examined cutoff value of PVC burden for predicting cardiac events. Receiver-operating characteristic analysis showed PVC burden (>0.145%/d) to be a predictive factor of cardiac events (area under the curve: 0.64). Kaplan-Meier analysis demonstrated that cardiac events were more frequent in patients with high-PVC burden (>0.145%/d, n = 194) compared to those with low-PVC burden (≤0.145%/d, n = 241). Furthermore, the high-PVC burden patients had left ventricular (LV) and atrial dilatation, reduced LV ejection fraction, and impaired exercise capacity, compared to the low-PVC burden patients. In Cox proportional hazards analysis, high-PVC burden was significantly associated with cardiac events with a hazard ratio of 2.028 (95% confidence interval: 1.418-2.901, P < .001). CONCLUSION: These results suggest that PVC burden is an important predictor of cardiac events in HF patients.

19.
Ann Noninvasive Electrocardiol ; 25(4): e12749, 2020 07.
Article in English | MEDLINE | ID: mdl-32083399

ABSTRACT

BACKGROUND: Cardiac amyloidosis (CA) is characterized by left ventricular hypertrophy (LVH) and autonomic nervous imbalance due to amyloid infiltration. However, autonomic dysfunction is often seen in heart failure (HF) with LVH from other etiologies. We aimed to characterize autonomic dysfunction in CA from other etiologies of LVH. METHODS: Fifty-five HF patients with LVH (35 males, mean age 65 ± 16 years) were enrolled. LVH was defined as left ventricular mass index measured by echocardiography >95 g/m2 in women and 115 g/m2 in men. The etiology was as follows: amyloid light chain (AL)-CA, n = 14; hypertrophic cardiomyopathy, n = 21; and aortic stenosis (AS), n = 20. With the patient in a clinically stable condition, heart rate variability (HRV) and heart rate turbulence (HRT), which reflect autonomic dysfunction, were measured using Holter monitoring and compared among the three groups. RESULTS: Brain natriuretic peptide levels, LVH severity, left ventricular ejection fraction, and tissue Doppler index E/e' did not differ among the three groups. However, severe abnormalities of HRV and HRT were obtained in AL-CA. In the ROC analysis to identify AL-CA in HF with LVH, the best cutoff value for standard deviation of all R-R intervals, standard deviation of the 5-min mean R-R intervals, turbulence onset, and turbulence slope were 68.5 ms (AUC: 0.865), 58.5 ms (AUC: 0.834), 0.25% (AUC: 0.813), and 1.00 ms/RR (AUC 0.736), respectively. CONCLUSION: Autonomic dysfunction is a hallmark of AL-CA, and its noninvasive assessment by Holter monitoring may be a useful tool for differential diagnosis of HF with LVH.


Subject(s)
Amyloidosis/complications , Amyloidosis/physiopathology , Autonomic Nervous System Diseases/complications , Autonomic Nervous System Diseases/physiopathology , Heart Diseases/complications , Heart Rate/physiology , Aged , Amyloidosis/diagnosis , Autonomic Nervous System Diseases/diagnosis , Echocardiography/methods , Electrocardiography, Ambulatory/methods , Female , Heart Diseases/diagnosis , Heart Diseases/physiopathology , Humans , Male , Middle Aged
20.
J Arrhythm ; 36(5): 874-882, 2020 Oct.
Article in English | MEDLINE | ID: mdl-34484475

ABSTRACT

BACKGROUND: To investigate the clinical implication of the temporal difference in atrial fibrillation (AF)-onset in acute decompensated heart failure (ADHF) and its impact on post-discharge prognosis. METHODS: 336 new-onset ADHF patients without any history of AF before admission were enrolled (201 males, 63 ± 16 year-old) and classified into two groups based on their history of AF: the Control group (No AF was detected during hospitalization, n = 278), and the In-hos-AF group (AF occurred during hospitalization, n = 58). Post discharge prognosis including rehospitalization due to worsening HF, cardiac death, all-cause death and cerebrovascular event were compared. RESULTS: Kaplan-Meier analysis demonstrated that the incidence of rehospitalization due to HF, cardiac death, all-cause death and cerebrovascular event in the In-hos-AF group was not significantly different from that in the Control group (P > 0.05 respectively). However, when AF recurred in the In-hos-AF group patients (n = 24, 41%) after discharge, the incidence of rehospitalization due to HF and cardiac deaths were higher than those without AF recurrence (P = 0.018 and P = 0.027 respectively). Cox proportional analysis revealed that AF developing after discharge was proven to be an independent risk factor for rehospitalization due to HF (HR 1.845, P = 0.043), cardiac death (HR 3.562, P = 0.013) and all-cause deaths (HR 2.138, P = 0.020). CONCLUSION: Clinical outcomes of new-onset in-hospital AF patients were as good as those without AF history until AF recurrence. However, AF recurrence led to worse prognosis. Therefore, treatment for new-onset in-hospital AF in ADHF patients might be postponed until AF recurrence.

SELECTION OF CITATIONS
SEARCH DETAIL
...