1.
Mod Rheumatol ; 25(2): 286-91, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25109744

ABSTRACT

OBJECTIVES: This study aimed to evaluate the clinical safety and wear-resistance of the novel highly cross-linked polyethylene (HXLPE) acetabular liner with surface grafting of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) at 3 years after total hip replacement (THR). METHODS: Eighty consecutive patients underwent cementless THR using a 26-mm diameter cobalt-chromium-molybdenum alloy femoral head and a PMPC-grafted HXLPE liner for the bearing couplings. We evaluated the clinical and radiographic outcomes of 76 patients at 3 years after the index surgery. RESULTS: The clinical results at 3 years were equivalent to a Harris hip score of 95.6 points. No adverse events were associated with the implanted PMPC-grafted HXLPE liner, and no periprosthetic osteolysis was detected. The mean femoral head penetration rate was 0.002 mm/year, representing marked reduction compared with other HXLPE liners. CONCLUSIONS: A PMPC-grafted HXLPE liner is a safe option in THR and probably reduces the generation of wear particles.


Subject(s)
Arthroplasty, Replacement, Hip , Femur Head Necrosis/surgery , Hip Joint/surgery , Hip Prosthesis , Osteoarthritis, Hip/surgery , Phosphorylcholine/analogs & derivatives , Polymethacrylic Acids , Adult , Aged , Female , Femur Head Necrosis/diagnostic imaging , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Prospective Studies , Radiography , Treatment Outcome
2.
J Artif Organs ; 16(2): 170-5, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23238557

ABSTRACT

To control particle-induced osteolysis in total hip replacement (THR), we developed a new technique to graft poly(2-methacryloyloxyethyl phosphorylcholine) onto the surface of polyethylene liners. A prospective cohort study was conducted to investigate the clinical safety of this novel bearing surface. Between April 2007 and September 2008, we recruited a prospective consecutive series of 80 patients in five participating hospitals. These patients received a cementless THR; a 26-mm-diameter cobalt-chromium-molybdenum alloy ball and a poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liner were used for the bearing couplings. These individuals were followed a year postoperatively. An evaluation of clinical performance was conducted through an assessment of hip joint function based on the evaluation chart authorized by the Japanese Orthopaedic Association. No patients were lost to follow-up. No adverse events were found to be correlated with the implanted liners. The average hip joint function score improved from 43.2 preoperatively to 91.7 postoperatively at 1 year. There was no implant migration nor periprosthetic osteolysis detected on radiographic analysis. On the basis of our results, we conclude that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted cross-linked polyethylene liners are a safe implant option for hip replacement surgery for short-term clinical use.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Methacrylates , Phosphorylcholine/analogs & derivatives , Adult , Aged , Female , Humans , Male , Middle Aged , Polyethylenes , Polymethacrylic Acids , Postoperative Complications , Prospective Studies , Prosthesis Design , Treatment Outcome