1.
Adv Radiat Oncol ; 9(3): 101390, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38292891

ABSTRACT

Purpose: The combination of surface-guided radiation therapy (SGRT) and image-guided radiation therapy (IGRT) can provide complementary information of patient positioning throughout treatments. The ExacTrac Dynamic (EXTD) system is a combined SGRT and IGRT system that can provide real-time motion detection via optical surface and thermal tracking during treatment delivery, with stereoscopic x-ray for positional verification. The purpose of this study was to examine the performance of EXTD for intrafractional motion monitoring using real clinical cases. Methods and Materials: Treatment log files exported from EXTD for 40 patients with 335 fractions were retrospectively analyzed. Frequency of beam-hold triggered during treatments were recorded, with the comparison of shifts detected by optical surface tracking (EXTD_Thml) and x-ray verification (EXTD_Xray). Results: Among the 335 fractions, automatic beam-holds were triggered 41 times, followed by x-ray positional verification with internal anatomy. The difference of shifts detected by EXTD_Thml and EXTD_Xray were less than 1 mm and 1° in translational and rotational directions, respectively. After x-ray verification, none of them required the application of positional correction. Conclusions: The availability of x-ray imaging with optical surface tracking in EXTD is essential to verify whether geometric shifts are required to correct patient position. Considering the ability of continuous monitoring of patient positions with optical surface tracking and internal imaging, EXTD is an effective tool for intrafractional motion monitoring during radiation therapy.

2.
Biomed Phys Eng Express ; 8(6)2022 09 29.
Article in English | MEDLINE | ID: mdl-36130477

ABSTRACT

Objective.To study the effects of magnetic field gradients on the dose deposition in an inhomogeneous medium and to present the benefits offered by magnetic-field-modulated radiotherapy (MagMRT) under multiple radiation beams.Approach.Monte Carlo simulations were performed using the Geant4 simulation toolkit with a 7 MV photon beam from an Elekta Unity system. A water cuboid embedded with material slabs of water, bone, lung or air was used to study the effects of MagMRT within inhomogeneous medium. Two cylindrical water phantoms, with and without a toroidal lung insert embedded, were used to study the effects of MagMRT under single, opposing or four cardinal radiation beams. Optimized magnetic field variations in the form of a wavelet were used to induce dose modulation within the material slabs or at the iso-center of the phantoms.Main results.The magnitudes of the dose enhancement and reduction induced by the magnetic field gradients become more prominent in a medium of lower density. A maximum dose increase of 6.5% and a decrease of 4.8% were found inside bone, while an increase of 20.4% and a decrease of 13.9% were found in lung tissue. Under multiple radiation beams, the dose enhancement can be induced at the iso-center while the dose reduction occurs in regions around the tumor. For the case with four cardinal beams irradiating a homogeneous water cylinder, an 8.4% of dose enhancement and a 2.4% of dose reduction were found. When a toroidal lung insert was embedded, a maximum dose enhancement of 9.5% and a reduction of 17.0% were produced for anterior-posterior opposing fields.Significance.With an optimized magnetic field gradient, MagMRT can induce a dose boost to the target while producing a better sparing to the surrounding normal tissue, resulting in a sharper dose fall-off in all directions outside the target volume.


Subject(s)
Lung , Magnetic Fields , Lung/radiation effects , Monte Carlo Method , Phantoms, Imaging , Water
3.
J Appl Clin Med Phys ; 23(8): e13698, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35699203

ABSTRACT

PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto-assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto-assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose-to-medium (Dm ) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D98% , D2% , and Dmean of the PTV69.96 _Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D98% , 3% difference in D2% , and 11.2% difference in Dmean were observed in the worst cases for PTV69.96 . Similar trend was observed for the PTV5940 _Air Cavity, in which the D98% , D2% , and Dmean calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D98% , D2% , and Dmean could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control.


Subject(s)
Nasopharyngeal Neoplasms , Radiotherapy, Intensity-Modulated , Algorithms , Humans , Nasal Cavity , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
4.
Med Dosim ; 47(2): 161-165, 2022.
Article in English | MEDLINE | ID: mdl-35241348

ABSTRACT

The purpose of this work was to study the radiobiological effect of using Acuros XB (AXB) vs Analytic Anisotropic Algorithm (AAA) on hepatocellular carcinoma (HCC) stereotactic body radiation therapy (SBRT). Seventy SBRT volumetric modulated arc therapy (VMAT) plans for HCC were calculated using AAA and AXB respectively with the same treatment parameters. Published tumor control probability (TCP) and normal tissue complication probability (NTCP) models were used to quantify the effect of dosimetric difference between AAA and AXB on TCP, NTCP and uncomplicated tumor control probability (UTCP). There was an average decrease of 2.5% in 6-month TCP. Normal liver has the largest average decrease in NTCP which was 59.7%. Bowels followed with 26.6% average decrease in NTCP. Duodenum, stomach and esophagus had 10.2%, 5.1%, and 4.3% average decrease in NTCP. There was an average decrease of 1.8% and up to 7.2% in 6-month UTCP. There was an overall decrease in TCP, NTCP, and UTCP for HCC SBRT plans calculated using AXB compared to AAA which could be clinically significant.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Radiosurgery , Algorithms , Carcinoma, Hepatocellular/radiotherapy , Humans , Liver Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted
5.
J Appl Clin Med Phys ; 23(5): e13567, 2022 May.
Article in English | MEDLINE | ID: mdl-35188333

ABSTRACT

Accurate detection of patient shift is essential during radiation therapy such that optimal dose is delivered to the tumor while minimizing radiation to surrounding normal tissues. The shift detectability of a newly developed optical surface and thermal tracking system, which was known as ExacTrac Dynamic (EXTD), was evaluated by comparing its performance with the image guidance under cone-beam computed tomography (CBCT). Anthropomorphic cranial and pelvis phantoms with internal bone-like structures and external heat pad were utilized to study the shift detection discrepancy between EXTD system and CBCT. Random displacements within the range of ± 2 cm for translations and ± 2 degrees for rotations were intentionally applied to the phantom. Positional shifts detected by optical surface and thermal tracking (EXTD_Thml), stereoscopic X-ray (EXTD_Xray), and CBCT were compared in 6 degrees of freedom. The translational difference between EXTD_Thml and CBCT was 0.57 ± 0.41 mm and 0.66 ± 0.40 mm for cranial and pelvis phantom, respectively, while it was 0.60 ± 0.43 mm and 0.76 ± 0.49 mm between EXTD_Xray and CBCT, respectively. For rotational movement, the difference between EXTD_Thml and CBCT was 0.19 ± 0.16° and 0.19 ± 0.22° for cranial and pelvis phantom, respectively, while it was 0.13 ± 0.18° and 0.65 ± 0.46° between EXTD_Xray and CBCT, respectively. This study demonstrated that the EXTD system with thermal mapping ability could offer comparable accuracy for shift detection with CBCT on both cranial and pelvis phantoms.


Subject(s)
Neoplasms , Radiosurgery , Cone-Beam Computed Tomography/methods , Humans , Phantoms, Imaging , Radiography , Radiosurgery/methods
6.
Phys Med Biol ; 66(20)2021 10 14.
Article in English | MEDLINE | ID: mdl-34587609

ABSTRACT

Objective.The feasibility of magnetic-field-modulated radiotherapy (MagMRT) with an MR-LINAC was investigated by studying the effects of dose enhancement and reduction using a transverse magnetic field with a longitudinal gradient applied along a photon radiation beam.Approach.Geant4 simulation toolkit was used to perform Monte Carlo simulations on a water phantom with the energy spectrum of a 7 MV flattening-filter-free photon beam from an Elekta Unity system as the source of radiation. Linear magnetic field gradients with magnitudes ranged from 1 to 6 T cm-1and spatial extents of 1-3 cm were used to study the dependence of dose modulation on these two parameters. The effects of radiation field size and the ability of dose modulation through optimizing the waveform of magnetic field variation were also explored.Main results.Our results show that dose enhancement and reduction can be achieved by applying a transverse magnetic field with a longitudinal field gradient along a photon beam. The steeper the gradient, the more prominent is the effect. A dose enhancement of 33% and a dose reduction of 22% are found for a magnetic gradient of 6 T cm-1and -6 T cm-1respectively. The spatial extent of the dose modulation effect which is greater than 3% is found to be around 1-2 cm. Both the dose enhancement and reduction effects are independent of the radiation field sizes, but they exhibit different behaviors with the spatial extents of the gradient. Multiple locations of dose enhancement and reduction can be produced by modulating the waveform of the magnetic field variation along the radiation beam, demonstrating a vast degree of freedom in the modulation aspect of MagMRT.Significance.MagMRT is a conceptually feasible and promising new radiotherapy modulation technique along the direction of the radiation beam.


Subject(s)
Particle Accelerators , Radiation Oncology , Magnetic Fields , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage
7.
Adv Radiat Oncol ; 6(5): 100739, 2021.
Article in English | MEDLINE | ID: mdl-34355107

ABSTRACT

PURPOSE: This work was to establish an uncomplicated tumor control probability (UTCP) model using hepatocellular carcinoma (HCC) stereotactic body radiation therapy (SBRT) clinical data in our institution. The model was then used to analyze the current dose prescription method and to seek the opportunity for improvement. METHODS AND MATERIALS: A tumor control probability (TCP) model was generated based on local clinical data using the maximum likelihood method. A UTCP model was then formed by combining the established TCP model with the normal tissue complication probability model based on the study by Dawson et al. The authors investigated the dependence of maximum achievable UTCP on planning target volume equivalent uniform dose (EUD) at various ratio between planning target volume EUD and normal liver EUD (T/N EUD ratios). A new term uncomplicated tumor control efficiency (UTCE) was also introduced to analyze the outcome. A UTCE value of 1 implied that the theoretical maximum UTCP for the corresponding T/N EUD ratio was achieved. RESULTS: The UTCE of the HCC SBRT patients based on the current dose prescription method was found to be 0.93 ± 0.05. It was found that the UTCE could be increased to 0.99 ± 0.03 by using a new dose prescription scheme, for which the UTCP could be maximized while keeping the normal tissue complication probability value smaller than 5%. CONCLUSIONS: The dose prescription method of the current HCC SBRT in our institution was analyzed using a UTCP model established based on local clinical data. It was shown that there could be a potential to increase the prescription dose of HCC SBRT. A new dose prescription scheme was proposed to achieve better UTCP. Additional clinical trials would be required to validate the proposed dose prescription scheme in the future.

8.
J Appl Clin Med Phys ; 21(11): 179-187, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33073897

ABSTRACT

An in-house trajectory log analysis program (LOGQA) was developed to evaluate the delivery accuracy of volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT). Methods have been established in LOGQA to provide analysis on dose indices, gantry angles, and multi-leaf collimator (MLC) positions. Between March 2019 and May 2020, 120 VMAT SBRT plans of various treatment sites using flattening filter-free (FFF) mode were evaluated using both LOGQA and phantom measurements. Gantry angles, dose indices, and MLC positions were extracted from log and compared with each plan. Integrated transient fluence map (ITFM) was reconstructed from log to examine the deviation of delivered fluence against the planned one. Average correlation coefficient of dose index versus gantry angle and ITFM for all patients were 1.0000, indicating that the delivered beam parameters were in good agreement with planned values. Maximum deviation of gantry angles and monitor units (MU) of all patients were less than 0.2 degree and 0.03 % respectively. Regarding MLC positions, maximum and root-mean-square (RMS) deviations from planned values were less than 0.6 mm and 0.3 mm respectively, indicating that MLC positions during delivery followed planned values in precise manner. Results of LOGQA were consistent with measurement, where all gamma-index passing rates were larger than 95 %, with 2 %/2 mm criteria. Three types of intentional errors were introduced to patient plan for software validation. LOGQA was found to recognize the introduced errors of MLC positions, gantry angles, and dose indices with magnitudes of 1 mm, 1 degree, and 5 %, respectively, which were masked in phantom measurement. LOGQA was demonstrated to have the potential to reduce or even replace patient-specific QA measurements for SBRT plan delivery provided that the frequency and amount of measurement-based machine-specific QA can be increased to ensure the log files record real values of machine parameters.


Subject(s)
Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
9.
PLoS One ; 9(11): e112229, 2014.
Article in English | MEDLINE | ID: mdl-25372041

ABSTRACT

PURPOSE: Intensity-modulated radiation therapy (IMRT) is the most common treatment technique for nasopharyngeal carcinoma (NPC). Physical quantities such as dose/dose-volume parameters are used conventionally for IMRT optimization. The use of biological related models has been proposed and can be a new trend. This work was to assess the performance of the biologically based IMRT optimization model installed in a popular commercial treatment planning system (Eclipse) as compared to its dose/dose volume optimization model when employed in the clinical environment for NPC cases. METHODS: Ten patients of early stage NPC and ten of advanced stage NPC were selected for this study. IMRT plans optimized using biological related approach (BBTP) were compared to their corresponding plans optimized using the dose/dose volume based approach (DVTP). Plan evaluation was performed using both biological indices and physical dose indices such as tumor control probability (TCP), normal tissue complication probability (NTCP), target coverage, conformity, dose homogeneity and doses to organs at risk. The comparison results of the more complex advanced stage cases were reported separately from those of the simpler early stage cases. RESULTS: The target coverage and conformity were comparable between the two approaches, with BBTP plans producing more hot spots. For the primary targets, BBTP plans produced comparable TCP for the early stage cases and higher TCP for the advanced stage cases. BBTP plans reduced the volume of parotid glands receiving doses of above 40 Gy compared to DVTP plans. The NTCP of parotid glands produced by BBTP were 8.0 ± 5.8 and 7.9 ± 8.7 for early and advanced stage cases, respectively, while those of DVTP were 21.3 ± 8.3 and 24.4 ± 12.8, respectively. There were no significant differences in the NTCP values between the two approaches for the serial organs. CONCLUSIONS: Our results showed that the BBTP approach could be a potential alternative approach to the DVTP approach for NPC.


Subject(s)
Models, Biological , Nasopharyngeal Neoplasms/radiotherapy , Patient Care Planning , Carcinoma , Female , Humans , Male , Nasopharyngeal Carcinoma
10.
J Appl Clin Med Phys ; 14(6): 4382, 2013 Nov 04.
Article in English | MEDLINE | ID: mdl-24257280

ABSTRACT

A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one without the use of the air cavity correction option (PRO10_no-air) for RapidArc planning in targets with low-density media of different sizes and complexities. The performance of PRO10_no-air and PRO10_air was initially compared using single-arc plans created for four different simple heterogeneous phantoms with virtual targets and organs at risk. Multiple-arc planning of 12 real patients having nasopharyngeal carcinomas (NPC) and ten patients having non-small cell lung cancer (NSCLC) were then performed using the above two options for further comparison. Dose calculations were performed using both the Acuros XB (AXB) algorithm with the dose to medium option and the analytical anisotropic algorithm (AAA). The effect of using intermediate dose option after the first optimization cycle in PRO10_air and PRO10_no-air was also investigated and compared. Plans were evaluated and compared using target dose coverage, critical organ sparing, conformity index, and dose homogeneity index. For NSCLC cases or cases for which large volumes of low-density media were present in or adjacent to the target volume, the use of the air cavity correction option in PRO10 was shown to be beneficial. For NPC cases or cases for which small volumes of both low- and high-density media existed in the target volume, the use of air cavity correction in PRO10 did not improve the plan quality. Based on the AXB dose calculation results, the use of PRO10_air could produce up to 18% less coverage to the bony structures of the planning target volumes for NPC cases. When the intermediate dose option in PRO10 was used, there was negligible difference observed in plan quality between optimizations with and without using the air cavity correction option.


Subject(s)
Algorithms , Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Carcinoma , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung Neoplasms/pathology , Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms/pathology , Neoplasm Staging , Organs at Risk , Phantoms, Imaging , Radiotherapy Dosage
11.
Biomed Res Int ; 2013: 692874, 2013.
Article in English | MEDLINE | ID: mdl-24066294

ABSTRACT

Deterministic linear Boltzmann transport equation (D-LBTE) solvers have recently been developed, and one of the latest available software codes, Acuros XB, has been implemented in a commercial treatment planning system for radiotherapy photon beam dose calculation. One of the major limitations of most commercially available model-based algorithms for photon dose calculation is the ability to account for the effect of electron transport. This induces some errors in patient dose calculations, especially near heterogeneous interfaces between low and high density media such as tissue/lung interfaces. D-LBTE solvers have a high potential of producing accurate dose distributions in and near heterogeneous media in the human body. Extensive previous investigations have proved that D-LBTE solvers were able to produce comparable dose calculation accuracy as Monte Carlo methods with a reasonable speed good enough for clinical use. The current paper reviews the dosimetric evaluations of D-LBTE solvers for external beam photon radiotherapy. This content summarizes and discusses dosimetric validations for D-LBTE solvers in both homogeneous and heterogeneous media under different circumstances and also the clinical impact on various diseases due to the conversion of dose calculation from a conventional convolution/superposition algorithm to a recently released D-LBTE solver.


Subject(s)
Neoplasms/radiotherapy , Radiometry , Software , Humans , Monte Carlo Method , Neoplasms/pathology , Photons
12.
Med Dosim ; 38(3): 337-43, 2013.
Article in English | MEDLINE | ID: mdl-23642300

ABSTRACT

We attempted to assess the effect of target-organ geometric complexity on the plan quality of sliding-window intensity-modulated radiotherapy (IMRT), double-arc (RA2), and triple-arc (RA3) RapidArc volumetric-modulated arc radiotherapy for nasopharyngeal carcinoma (NPC). Plans for 9-field sliding-window IMRT, RA2, and RA3 were optimized for 36 patients with NPC ranging from T1 to T4 tumors. Initially the patients were divided into 2 groups, with group A representing the most simple early stage (T1 and T2) cases, whereas group B represented the more complex advanced cases (T3 and T4). Evaluation was performed based on target conformity, target dose homogeneity, organ-sparing capability, and delivery efficiency. Based on the plan quality results, a subgroup of advanced cases, group B2, representing the most demanding task was distinguished and reported separately from the rest of the group B cases, B1. Detailed analysis was performed on the anatomic features for each group of cases, so that planners can easily identify the differences between B1 and B2. For the group A cases, RA3 plans were superior to the IMRT plans in terms of organ sparing, whereas target conformity and dose homogeneity were similar. For the group B1 cases, the RA3 plans produced almost equivalent plan quality as the IMRT plans. For the group B2 cases, for most of which large target volumes were adjacent to (5mm or less) and wrapping around the brain stem, RA2 and RA3 were inferior to the IMRT regarding both target dose homogeneity and conformity. RA2 plans were slightly inferior to IMRT and RA3 plans for most cases. The plan comparison results depend on the target to brain stem distances and the target sizes. The plan quality results together with the anatomic information may allow the evaluation of the 3 treatment options before actual planning.


Subject(s)
Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Carcinoma , Humans , Nasopharyngeal Carcinoma , Organs at Risk , Radiotherapy Dosage
13.
Med Phys ; 40(3): 031714, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23464309

ABSTRACT

PURPOSE: To compare the doses calculated by the Acuros XB (AXB) algorithm and analytical anisotropic algorithm (AAA) with experimentally measured data adjacent to and within heterogeneous medium using intensity modulated radiation therapy (IMRT) and RapidArc(®) (RA) volumetric arc therapy plans for nasopharygeal carcinoma (NPC). METHODS: Two-dimensional dose distribution immediately adjacent to both air and bone inserts of a rectangular tissue equivalent phantom irradiated using IMRT and RA plans for NPC cases were measured with GafChromic(®) EBT3 films. Doses near and within the nasopharygeal (NP) region of an anthropomorphic phantom containing heterogeneous medium were also measured with thermoluminescent dosimeters (TLD) and EBT3 films. The measured data were then compared with the data calculated by AAA and AXB. For AXB, dose calculations were performed using both dose-to-medium (AXB_Dm) and dose-to-water (AXB_Dw) options. Furthermore, target dose differences between AAA and AXB were analyzed for the corresponding real patients. The comparison of real patient plans was performed by stratifying the targets into components of different densities, including tissue, bone, and air. RESULTS: For the verification of planar dose distribution adjacent to air and bone using the rectangular phantom, the percentages of pixels that passed the gamma analysis with the ± 3%/3mm criteria were 98.7%, 99.5%, and 97.7% on the axial plane for AAA, AXB_Dm, and AXB_Dw, respectively, averaged over all IMRT and RA plans, while they were 97.6%, 98.2%, and 97.7%, respectively, on the coronal plane. For the verification of planar dose distribution within the NP region of the anthropomorphic phantom, the percentages of pixels that passed the gamma analysis with the ± 3%/3mm criteria were 95.1%, 91.3%, and 99.0% for AAA, AXB_Dm, and AXB_Dw, respectively, averaged over all IMRT and RA plans. Within the NP region where air and bone were present, the film measurements represented the dose close to unit density water in a heterogeneous medium, produced the best agreement with the AXB_Dw. For the verification of point doses within the target using TLD in the anthropomorphic phantom, the absolute percentage deviations between the calculated and measured data when averaged over all IMRT and RA plans were 1.8%, 1.7%, and 1.8% for AAA, AXB_Dm and AXB_Dw, respectively. From all the verification results, no significant difference was found between the IMRT and RA plans. The target dose analysis of the real patient plans showed that the discrepancies in mean doses to the PTV component in tissue among the three dose calculation options were within 2%, but up to about 4% in the bone content, with AXB_Dm giving the lowest values and AXB_Dw giving the highest values. CONCLUSIONS: In general, the verification measurements demonstrated that both algorithms produced acceptable accuracy when compared to the measured data. GafChromic(®) film results indicated that AXB produced slightly better accuracy compared to AAA for dose calculation adjacent to and within the heterogeneous media. Users should be aware of the differences in calculated target doses between options AXB_Dm and AXB_Dw, especially in bone, for IMRT and RA in NPC cases.


Subject(s)
Nasopharyngeal Neoplasms/radiotherapy , Radiation Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Intensity-Modulated/instrumentation , Carcinoma , Humans , Nasopharyngeal Carcinoma , Phantoms, Imaging , Radiometry , Radiotherapy Dosage
14.
Int J Radiat Oncol Biol Phys ; 85(1): e73-80, 2013 Jan 01.
Article in English | MEDLINE | ID: mdl-23040220

ABSTRACT

PURPOSE: To assess the dosimetric implications for the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy with RapidArc (RA) of nasopharyngeal carcinomas (NPC) due to the use of the Acuros XB (AXB) algorithm versus the anisotropic analytical algorithm (AAA). METHODS AND MATERIALS: Nine-field sliding window IMRT and triple-arc RA plans produced for 12 patients with NPC using AAA were recalculated using AXB. The dose distributions to multiple planning target volumes (PTVs) with different prescribed doses and critical organs were compared. The PTVs were separated into components in bone, air, and tissue. The change of doses by AXB due to air and bone, and the variation of the amount of dose changes with number of fields was also studied using simple geometric phantoms. RESULTS: Using AXB instead of AAA, the averaged mean dose to PTV70 (70 Gy was prescribed to PTV70) was found to be 0.9% and 1.2% lower for IMRT and RA, respectively. It was approximately 1% lower in tissue, 2% lower in bone, and 1% higher in air. The averaged minimum dose to PTV70 in bone was approximately 4% lower for both IMRT and RA, whereas it was approximately 1.5% lower for PTV70 in tissue. The decrease in target doses estimated by AXB was mostly contributed from the presence of bone, less from tissue, and none from air. A similar trend was observed for PTV60 (60 Gy was prescribed to PTV60). The doses to most serial organs were found to be 1% to 3% lower and to other organs 4% to 10% lower for both techniques. CONCLUSIONS: The use of the AXB algorithm is highly recommended for IMRT and RapidArc planning for NPC cases.


Subject(s)
Algorithms , Nasopharyngeal Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Air , Anisotropy , Bone and Bones/radiation effects , Carcinoma , Humans , Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms/diagnostic imaging , Nasopharyngeal Neoplasms/pathology , Phantoms, Imaging , Radiography , Radiometry/methods , Tumor Burden
15.
J Appl Clin Med Phys ; 13(6): 3887, 2012 Nov 08.
Article in English | MEDLINE | ID: mdl-23149781

ABSTRACT

The purpose of this study was to investigate the potential benefits of using triple-arc volumetric-intensity modulated arc radiotherapy (RapidArc (RA)) for the treatment of early-stage nasopharyngeal carcinoma (NPC). A comprehensive evaluation was performed including plan quality, integral doses, and peripheral doses. Twenty cases of stage I or II NPC were selected for this study. Nine-field sliding window IMRT, double-arc, and triple-arc RA treatment plans were compared with respect to target coverage, dose conformity, critical organ sparing, and integral doses. Measurement of peripheral doses was performed using thermoluminescent dosimeters in an anthropomorphic phantom. While similar conformity and target coverage were achieved by the three types of plans, triple-arc RA produced better sparing of parotid glands and spinal cord than double-arc RA or IMRT. Double-arc RA plans produced slightly inferior parotid sparing and dose homogeneity than the other two delivery methods. The monitor units (MU) required for triple-arc were about 50% less than those of IMRT plans, while there was no significant difference in the required MUs between triple-arc and double-arc RA plans. The peripheral dose in triple-arc RA was found to be 50% less compared to IMRT near abdominal and pelvic region. Triple-arc RA improves both the plan quality and treatment efficiency compared with IMRT for the treatment of early stage NPC. It has become the preferred choice of treatment delivery method for early stage NPC at our center.


Subject(s)
Film Dosimetry , Nasopharyngeal Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Carcinoma , Humans , Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms/pathology , Neoplasm Staging , Phantoms, Imaging , Radiotherapy Dosage
16.
Med Phys ; 39(8): 4705-14, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22894395

ABSTRACT

PURPOSE: The main aim of the current study was to assess the dosimetric impact on intensity modulated stereotactic radiotherapy (IMSRT) for locally persistent nasopharyngeal carcinoma (NPC) due to the recalculation from the Anisotropic Analytical Algorithm (AAA) to the recently released Acuros XB (AXB) algorithm. The dosimetric accuracy of using AXB in predicting air∕tissue interface doses from an open single small field in a simple geometric phantom and intensity modulated small fields in an anthropomorphic phantom was also investigated. METHODS: The central axis percentage depth doses (PDD) of a rectangular phantom containing an air cavity were calculated by both AAA and AXB from 6 MV beam with small field sizes (2 × 2 to 5 × 5 cm(2)). These data were compared to PDD measured by thin thermoluminescent dosimeters (TLDs) and Monte Carlo simulations. The doses predicted by AAA and AXB near air∕tissue interfaces from five different IMSRT plans were compared to the TLD measured doses in an anthropomorphic phantom. The PTV coverage, conformity and doses to organs at risk (OARs) calculated by AAA and AXB were compared for 12 patients, using identical beam setup, leaves movement and monitor units. RESULTS: Testing using the simple rectangular phantom demonstrated that AAA and AXB overestimated the PDD at the air∕tissue interfaces by up to 41% and 6%, respectively, from a 2 × 2 cm(2) field. The secondary build-up curves predicted by AXB caught up well with the measured data at around 2 mm beyond the air cavity. Testing using the anthropomorphic phantom showed that AAA overestimated the doses by up to 10%, while the measured doses matched those of the AXB to within 3%. Using AAA, the planning target coverage represented by 100% of the reference dose was estimated to be 4% higher than using AXB. The averaged minimum dose to the PTV predicted by AAA was about 4% higher and OARs doses 3% to 6% higher compared to AXB. CONCLUSIONS: AXB should be used whenever possible as the standard reference for IMSRT boost of NPC cases. The more accurate AXB indicating lower target coverage and lower minimum target dose compared to AAA should be noted.


Subject(s)
Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Radiation Oncology/methods , Radiometry/methods , Radiosurgery/methods , Radiotherapy, Intensity-Modulated/methods , Algorithms , Anisotropy , Humans , Monte Carlo Method , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Reproducibility of Results , Tomography, X-Ray Computed/methods
17.
Med Dosim ; 36(2): 138-44, 2011.
Article in English | MEDLINE | ID: mdl-20510601

ABSTRACT

We attempted to develop a method to compute the normal tissue complication probability (NTCP) of various critical organs from combined intensity-modulated radiotherapy (IMRT) and stereotactic radiotherapy (SRT) boost treatment of nasopharyngeal carcinoma (NPC), with the aid of a nonlinear image registration method. The SRT's planning computed tomography (CT) of a NPC patient treated with IMRT was warped to the IMRT's planning CT using a nonlinear image registration. Because CT and dose were inherently in-register, the entire dose distribution could be deformed using the same deformation field derived from the two CT sets. Using the biologically effective dose concept and the linear-quadratic model, physical doses of IMRT and SRT were converted to a 2 Gy-per-fraction equivalent dose to facilitate dose summation. The variation of organs' maximum doses of the combined treatments between traditional maximum dose sum and the proposed method was 1.5 Gy ± 1.7 Gy. After the correction of the effect of fractionation and dose heterogeneity within each organ, NTCP of each organ of interest was computed for the combined treatments. Based on the results of this case study, it is believed that dose registration could be a method for the NTCP computation of various critical organs when different fractionation schemes of radiation therapy treatment are instituted.


Subject(s)
Models, Biological , Nasopharyngeal Neoplasms/surgery , Radiation Injuries/etiology , Radiation Protection/methods , Radiometry/methods , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Body Burden , Case-Control Studies , Computer Simulation , Data Interpretation, Statistical , Dose-Response Relationship, Radiation , Humans , Models, Statistical , Radiation Dosage , Radiation Injuries/prevention & control
18.
Med Dosim ; 35(4): 255-63, 2010.
Article in English | MEDLINE | ID: mdl-19962878

ABSTRACT

The use of noncoplanar intensity-modulated radiation therapy (IMRT) might result in better sparing of some critical organs because of a higher degree of freedom in beam angle optimization. However, this can lead to a potential increase in peripheral dose compared with coplanar IMRT. The peripheral dose from noncoplanar IMRT has not been previously quantified. This study examines the peripheral dose from noncoplanar IMRT compared with coplanar IMRT for pediatric radiation therapy. Five cases with different pediatric malignancies in head and neck were planned with both coplanar and noncoplanar IMRT techniques. The plans were performed such that the tumor coverage, conformality, and dose uniformity were comparable for both techniques. To measure the peripheral doses of the 2 techniques, thermoluminescent dosimeters (TLD) were placed in 10 different organs of a 5-year-old pediatric anthropomorphic phantom. With the use of noncoplanar beams, the peripheral doses to the spinal cord, bone marrow, lung, and breast were found to be 1.8-2.5 times of those using the coplanar technique. This is mainly because of the additional internal scatter dose from the noncoplanar beams. Although the use of noncoplanar technique can result in better sparing of certain organs such as the optic nerves, lens, or inner ears depending on how the beam angles were optimized on each patient, oncologists should be alert of the possibility of significantly increasing the peripheral doses to certain radiation-sensitive organs such as bone marrow and breast. This might increase the secondary cancer risk to patients at young age.


Subject(s)
Body Burden , Head and Neck Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Whole-Body Counting/methods , Child , Child, Preschool , Female , Humans , Infant , Male
19.
Int J Radiat Oncol Biol Phys ; 70(1): 272-9, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-17980510

ABSTRACT

PURPOSE: To perform a comprehensive study on organ absorbed doses and effective doses from cone beam computed tomography (CBCT) for three different treatment sites. METHODS AND MATERIALS: An extensive set of dosimetric measurements were performed using a widely used CBCT system, the On-Board Imager (OBI). Measurements were performed using a female anthropomorphic phantom with thermoluminescent dosimeters (TLD). The effective doses to the body and the absorbed doses to 26 organs were reported using two different technical settings, namely, the standard mode and the low-dose mode. The measurements were repeated for three different scan sites: head and neck, chest, and pelvis. Comparisons of patient doses as well as image quality were performed among the standard mode CBCT, low-dose mode CBCT, and fan beam CT. RESULTS: The mean skin doses from standard mode CBCT to head and neck, chest and pelvis were 6.7, 6.4, and 5.4 cGy per scan, respectively. The effective doses to the body from standard mode CBCT for imaging of head and neck, chest, and pelvis were 10.3, 23.7, and 22.7 mSv per scan, respectively. Patient doses from low-dose mode CBCT were approximately one fifth of those from standard mode CBCT. CONCLUSIONS: Patient position verification by standard mode CBCT acquired by OBI on a daily basis could increase the secondary cancer risk by up to 2% to 4%. Therefore lower mAs settings for daily CBCT should be considered, especially when bony anatomy is the main interest.


Subject(s)
Cone-Beam Computed Tomography , Phantoms, Imaging , Radiation Dosage , Radiotherapy Dosage , Thermoluminescent Dosimetry/methods , Calibration , Female , Head , Humans , Neck , Particle Accelerators , Pelvis , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated