Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
iScience ; 25(10): 105199, 2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36248739

ABSTRACT

Buckling is a loss of structural stability. It occurs in long slender structures or thin plate structures which is subjected to compressive forces. For the structural materials, such a sudden change in shape has been considered to be avoided. In this study, we utilize the Au nanowire's buckling instability for the electrical measurement. We confirmed that the high-strength single crystalline Au nanowire with an aspect ratio of 150 and 230-nm-diameter shows classical Euler buckling under constant compressive force without failure. The buckling instability enables stable contact between the Au nanowire and the substrate without any damage. Clearly, the in situ electrical measurement shows a transition of the contact resistance between the nanowire and the substrate from the Sharvin (ballistic limit) mode to the Holm (Ohmic) mode during deformation, enabling reliable electrical measurements. This study suggests Au nanowire probes exhibiting structural instability to ensure stable and precise electrical measurements at the nanoscale.

2.
Sci Adv ; 8(15): eabm3622, 2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35417230

ABSTRACT

Skin-attachable sensors, which represent the ultimate form of wearable electronic devices that ensure conformal contact with skin, suffer from motion artifact limitations owing to relative changes in position between the sensor and skin during physical activities. In this study, a polarization-selective structure of a skin-conformable photoplethysmographic (PPG) sensor was developed to decrease the amount of scattered light from the epidermis, which is the main cause of motion artifacts. The motion artifacts were suppressed more than 10-fold in comparison with those of rigid sensors. The developed sensor-with two orthogonal polarizers-facilitated successful PPG signal monitoring during wrist angle movements corresponding to high levels of physical activity, enabling continuous monitoring of daily activities, even while exercising for personal health care.

3.
Sci Adv ; 7(23)2021 06.
Article in English | MEDLINE | ID: mdl-34088675

ABSTRACT

Skin-like health care patches (SHPs) are next-generation health care gadgets that will enable seamless monitoring of biological signals in daily life. Skin-conformable sensors and a stretchable display are critical for the development of standalone SHPs that provide real-time information while alleviating privacy concerns related to wireless data transmission. However, the production of stretchable wearable displays with sufficient pixels to display this information remains challenging. Here, we report a standalone organic SHP that provides real-time heart rate information. The 15-µm-thick SHP comprises a stretchable organic light-emitting diode display and stretchable organic photoplethysmography (PPG) heart rate sensor on all-elastomer substrate and operates stably under 30% strain using a combination of stress relief layers and deformable micro-cracked interconnects that reduce the mechanical stress on the active optoelectronic components. This approach provides a rational strategy for high-resolution stretchable displays, enabling the production of ideal platforms for next-generation wearable health care electronics.

4.
Nat Commun ; 10(1): 4454, 2019 10 01.
Article in English | MEDLINE | ID: mdl-31575854

ABSTRACT

While cracks are usually considered detrimental, crack generation can be harnessed for various applications, for example in ceramic materials, via directing crack propagation and crack opening. Here, we find that electron beam irradiation prompts a crack suppression phenomenon in a copper (Cu) thin film on a polyimide substrate, allowing for the control of crack formation in terms of both location and shape. Under tensile strain, cracks form on the unirradiated region of the Cu film whereas cracks are prevented on the irradiated region. We attribute this to the enhancement of the adhesion at the Cu-polyimide interface by electrons transmitted through the Cu film. Finally, we selectively form conductive regions in a Cu film on a polyimide substrate under tension and fabricate a strain-responsive organic light-emitting device.

5.
Nano Lett ; 18(2): 1323-1330, 2018 02 14.
Article in English | MEDLINE | ID: mdl-29361232

ABSTRACT

In the present study, we found that α-alumina hollow nanoshell structure can exhibit an ultrahigh fracture strength even though it contains a significant number of nanopores. By systematically performing in situ mechanical testing and finite element simulations, we could measure that the fracture strength of an α-alumina hollow nanoshell structure is about four times higher than that of the conventional bulk size α-alumina. The high fracture strength of the α-alumina hollow nanoshell structure can be explained in terms of conventional fracture mechanics, in that the position and size of the nanopores are the most critical factors determining the fracture strength, even at the nanoscales. More importantly, by deriving a fundamental understanding, we would be able to provide guidelines for the design of reliable ceramic nanostructures for advanced GaN light-emitting diodes (LEDs). To that end, we demonstrated how our ultrastrong α-alumina hollow nanoshell structures could be successfully incorporated into GaN LEDs, thereby greatly improving the luminous efficiency and output power of the LEDs by 2.2 times higher than that of conventional GaN LEDs.

SELECTION OF CITATIONS
SEARCH DETAIL
...