Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Assoc Med Bras (1992) ; 70(4): e20230998, 2024.
Article in English | MEDLINE | ID: mdl-38716936

ABSTRACT

OBJECTIVE: The use of cardiac implantable electronic devices has increased in recent years. It has also brought some issues. Among these, the complications of cardiac implantable electronic devices infection and pocket hematoma are difficult to manage. It can be fatal with the contribution of patient-related risk factors. In this study, we aimed to find mortality rates in patients who developed cardiac implantable electronic devices infection and pocket hematoma over 5 years. We also investigated the risk factors affecting mortality in patients with cardiac implantable electronic devices. METHODS: A total of 288 cardiac implantable electronic devices patients were evaluated. Demographic details, history, and clinical data of all patients were recorded. Cardiac implantable electronic devices infection was defined according to the modified Duke criteria. The national registry was used to ascertain the mortality status of the patients. The patients were divided into two groups (exitus and survival groups). In addition, the pocket hematoma was defined as significant bleeding at the pocket site after cardiac implantable electronic devices placement. RESULTS: The cardiac implantable electronic devices infection was similar in both groups (p=0.919), and the pocket hematoma was higher in the exitus group (p=0.019). The exitus group had higher usage of P2Y12 inhibitors (p≤0.001) and novel oral anticoagulants (p=0.031). The Cox regression analysis, including mortality-related factors, revealed that renal failure is the most significant risk factor for mortality. Renal failure was linked to a 2.78-fold higher risk of death. CONCLUSION: No correlation was observed between cardiac implantable electronic devices infection and mortality, whereas pocket hematoma was associated with mortality. Furthermore, renal failure was the cause of the highest mortality rate in patients with cardiac implantable electronic devices.


Subject(s)
Defibrillators, Implantable , Hematoma , Pacemaker, Artificial , Humans , Female , Male , Defibrillators, Implantable/adverse effects , Risk Factors , Aged , Middle Aged , Pacemaker, Artificial/adverse effects , Hematoma/etiology , Hematoma/mortality , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/etiology , Retrospective Studies , Time Factors , Aged, 80 and over
2.
Medicina (Kaunas) ; 59(6)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37374331

ABSTRACT

Background and Objectives: Smokeless tobacco (ST) use has recently become an alternative to cigarettes, and it has been concluded that ST is at least as harmful as cigarettes. ST use is thought to play a role in the pathogenesis of arrhythmia by affecting ventricular repolarization. In this study, we aimed to examine the relationships of Maras powder (MP), one of the ST varieties, with epicardial fat thickness and new ventricular repolarization parameters, which have not previously been described. Materials and Methods: A total of 289 male individuals were included in this study between April 2022 and December 2022. Three groups, 97 MP users, 97 smokers, and 95 healthy (non-tobacco), were compared according to electrocardiographic and echocardiographic data. Electrocardiograms (ECG) were evaluated with a magnifying glass by two expert cardiologists at a speed of 50 m/s. Epicardial fat thickness (EFT) was measured by echocardiography in the parasternal short- and long-axis images. A model was created with variables that could affect epicardial fat thickness. Results: There were no differences between the groups regarding body mass index (p = 0.672) and age (p = 0.306). The low-density lipoprotein value was higher in the MP user group (p = 0.003). The QT interval was similar between groups. Tp-e (p = 0.022), cTp-e (p = 0.013), Tp-e/QT (p =0.005), and Tp-e/cQT (p = 0.012) were higher in the MP user group. While the Tp-e/QT ratio did not affect EFT, MP predicted the epicardial fat thickness (p < 0.001, B = 0.522, 95%CI 0.272-0.773). Conclusions: Maras powder may play a role in ventricular arrhythmia by affecting EFT and causing an increase in the Tp-e interval.


Subject(s)
Tobacco, Smokeless , Humans , Male , Tobacco, Smokeless/adverse effects , Powders , Echocardiography , Electrocardiography , Arrhythmias, Cardiac/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...