Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Natl Compr Canc Netw ; 11(4): 414-21, 2013 Apr 01.
Article in English | MEDLINE | ID: mdl-23584344

ABSTRACT

Definitive radiation therapy is the preferred treatment for many men with prostate cancer. Several modalities are used for radiation treatment delivery, including 3-dimensional conformal radiation therapy, intensity-modulated radiation therapy, proton beam therapy, stereotactic body radiation therapy, high-dose-rate prostate brachytherapy, and low-dose-rate prostate brachytherapy. This article reviews technologic advances that have enhanced radiation delivery and describes contemporary radiation treatment techniques for prostate cancer.


Subject(s)
Adenocarcinoma/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiotherapy/methods , Brachytherapy/methods , Dose Fractionation, Radiation , Humans , Male , Models, Biological
2.
Med Dosim ; 38(3): 251-4, 2013.
Article in English | MEDLINE | ID: mdl-23540491

ABSTRACT

Weight loss or gain during the course of radiation therapy for prostate cancer can alter the planned dose to the target volumes and critical organs. Typically, source-to-surface distance (SSD) measurements are documented by therapists on a weekly basis to ensure that patients' exterior surface and isocenter-to-skin surface distances remain stable. The radiation oncology team then determines whether the patient has undergone a physical change sufficient to require a new treatment plan. The effect of weight change (SSD increase or decrease) on intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) dosimetry is not well known, and it is unclear when rescanning or replanning is needed. The purpose of this study was to determine the effects of weight change (SSD increase or decrease) on IMRT or VMAT dose delivery in patients with prostate cancer and to determine the SSD change threshold for replanning. Whether IMRT or VMAT provides better dose stability under weight change conditions was also determined. We generated clinical IMRT and VMAT prostate and seminal vesicle treatment plans for varying SSDs for 10 randomly selected patients with prostate cancer. The differences due to SSD change were quantified by a specific dose change for a specified volume of interest. The target mean dose, decreased or increased by 2.9% per 1-cm SSD decrease or increase in IMRT and by 3.6% in VMAT. If the SSD deviation is more than 1cm, the radiation oncology team should determine whether to continue treatment without modifications, to adjust monitor units, or to resimulate and replan.


Subject(s)
Body Weight/radiation effects , Prostatic Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated , Humans , Male , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Weight Gain , Weight Loss
3.
Med Dosim ; 37(2): 208-13, 2012.
Article in English | MEDLINE | ID: mdl-21978532

ABSTRACT

The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.


Subject(s)
Carcinoma, Ductal, Breast/radiotherapy , Inflammatory Breast Neoplasms/radiotherapy , Neoplasm Recurrence, Local/radiotherapy , Radiotherapy, Conformal/methods , Carcinoma, Ductal, Breast/surgery , Female , Humans , Inflammatory Breast Neoplasms/surgery , Middle Aged , Neoplasm Recurrence, Local/surgery
4.
Pract Radiat Oncol ; 2(3): 201-209, 2012.
Article in English | MEDLINE | ID: mdl-24674124

ABSTRACT

PURPOSE: The Radiation Therapy Oncology Group (RTOG) has published consensus guidelines for contouring relevant anatomy for postmastectomy radiation therapy (RT). How these contours relate to current treatment practices is unknown. We analyzed the dose-volume histograms (DVHs) for these contours using current clinical practice at University of Texas MD Anderson Cancer Center and compared them with the proposed treatment plans to treat RTOG-defined targets to full dose. METHODS AND MATERIALS: We retrospectively analyzed treatment plans for 20 consecutive women treated with postmastectomy RT for which the treatment targets were the chest wall (CW), level III axilla (Ax3), supraclavicular (SCV), and internal mammary (IM) nodes. The RTOG consensus definitions were used to contour the following anatomic structures: CW; level I, II, and III axillary nodes (Ax1, Ax2, Ax3); SCV; IM; and heart (H). DVHs for these contours and the ipsilateral lung were generated from clinically designed treatment that had actually been delivered to each patient. For comparison regarding dose to normal tissue, new treatment plans were generated with the goal of covering 95% of the anatomic contours to 45 Gy. RESULTS: The prescribed dose was 50 Gy in each case. The mean percent of volumes that received 45 Gy (V45) for the RTOG guideline-based contours were CW 74%, Ax1 84%, Ax2 88%, Ax3 96%, SCV 84%, and IM 80%. Mean heart V10 values were 11% for treatment of left-sided tumors and 6% for right-sided tumors. Mean ipsilateral lung V20 values were 28% for left-sided tumors and 34% for right-sided tumors. For the contour-based plans, mean V45 values were CW 94%, Ax1 95%, Ax2 97%, Ax3 98%, SCV 98%, and IM 85%. Mean heart V10 values were 14% for treatment of left-sided tumors and 12% for right-sided tumors. Mean ipsilateral lung V20 values were 32% for left-sided tumors and 45% for right-sided tumors. CONCLUSIONS: Clinically derived treatment plans, which have proven efficacy and are the current standard, cover 74% to 96% of the anatomy-based RTOG consensus volumes to the prescription dose. This discrepancy should be considered if treatment planning protocol guidelines are designed to incorporate these new definitions.

SELECTION OF CITATIONS
SEARCH DETAIL
...