Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Front Rehabil Sci ; 5: 1342370, 2024.
Article in English | MEDLINE | ID: mdl-38798750

ABSTRACT

Introduction: Bilateral microprocessor-controlled prosthetic knee (MPK) users have unique needs in traversing environmental barriers compared to unilateral users. An enhancement to the Genium™/Genium X3™ MPK which included an updated ruleset, hydraulics, and new bilateral parameter presets was made to improve safety while stumbling and the smoothness of gait for all users while also improving the experience of bilateral users. The purpose of the study was to evaluate the effectiveness of the enhancements in a sample with unilateral and bilateral amputation. Methods: A convenience sample of MPK users was recruited from two sites in the USA in two phases. Assessments included the L-Test of Functional Mobility, Activity-specific Balance Confidence Scale, Prosthetic Limb User Survey of Mobility, a study-specific questionnaire, and the Comparative Activities of Daily Living (ADL) Questionnaire. Statistical significance of extracted data was tested with the Wilcoxon Rank-Sum Test for independent data and Wilcoxon Signed-Rank for paired data with an a priori significance level of p < 0.05. Unilateral subjects were age-matched to the group of bilateral subjects for between-groups and within-groups analyses. Results: Twenty-six subjects (n = 26) were enrolled. Stumble frequency reduced 85% from 16.0 ± 39.7 to 2.4 ± 2.3 (p = 0.008) between baseline and final assessment overall. The bilateral group reported 50% (p = 0.009) and 57% (p = 0.009) greater relative improvement in patient-reported ease and safety, respectively, of completing ADLs compared to the unilateral group. The unilateral group reported residual limb pain and low back pain reduced from 2.3 to 1.4 (p = 0.020) and 3.8 to 1.8 (p = 0.027), respectively, whereas the bilateral group did not. Discussion: Substantial reductions in stumbles, residual limb pain, and back pain were shown overall. These reductions were driven by the unilateral group who also showed improvements in comfort, exertion, and concentration while walking. The enhancements to the knee likely reduced some gait asymmetry for unilateral users. Improvements in patient-reported ease and safety of completing ADLs were shown overall and were driven by the bilateral group. This study shows further improvement in patient experience is achievable through innovation in MPK technology even for patients who appear to be functioning well.

2.
J Neuroeng Rehabil ; 19(1): 9, 2022 01 28.
Article in English | MEDLINE | ID: mdl-35090505

ABSTRACT

BACKGROUND: Prosthetic feet are prescribed for persons with a lower-limb amputation to restore lost mobility. However, due to limited adaptability of their ankles and springs, situations like walking on slopes or uneven ground remain challenging. This study investigated to what extent a microprocessor-controlled prosthetic foot (MPF) facilitates walking on slopes. METHODS: Seven persons each with a unilateral transtibial amputation (TTA) and unilateral transfemoral amputation (TFA) as well as ten able-bodied subjects participated. Participants were studied while using a MPF and their prescribed standard feet with fixed ankle attachments. The study investigated ascending and descending a 10° slope. Kinematic and kinetic data were recorded with a motion capture system. Biomechanical parameters, in particular leg joint angles, shank orientation and external joint moments of the prosthetics side were calculated. RESULTS: Prosthetic feet- and subject group-dependent joint angle and moment characteristics were observed for both situations. The MPF showed a larger and situation-dependent ankle range of motion compared to the standard feet. Furthermore, it remained in a dorsiflexed position during swing. While ascending, the MPF adapted the dorsiflexion moment and reduced the knee extension moment. At vertical shank orientation, it reduced the knee extension moment by 26% for TFA and 49% for TTA compared to the standard feet. For descending, differences between feet in the biomechanical knee characteristics were found for the TTA group, but not for the TFA group. At the vertical shank angle during slope descent, TTA demonstrated a behavior of the ankle moment similar to able-bodied controls when using the MPF. CONCLUSIONS: The studied MPF facilitated walking on slopes by adapting instantaneously to inclinations and, thus, easing the forward rotation of the leg over the prosthetic foot compared to standard feet with a fixed ankle attachment with amputation-level dependent effect sizes. It assumed a dorsiflexed ankle angle during swing, enabled a larger ankle range of motion and reduced the moments acting on the residual knee of TTA compared to the prescribed prosthetic standard feet. For individuals with TFA, the prosthetic knee joint seems to play a more crucial role for walking on ramps than the foot.


Subject(s)
Amputees , Artificial Limbs , Amputation, Surgical , Biomechanical Phenomena , Foot , Gait , Humans , Microcomputers , Prosthesis Design , Walking
3.
Disabil Rehabil ; 44(24): 7349-7367, 2022 12.
Article in English | MEDLINE | ID: mdl-34694952

ABSTRACT

PURPOSE: The clinical benefits of microprocessor-controlled prosthetic knees (MPKs) in community ambulators have been well-established. A systematic review in limited community ambulators published in 2014 found benefits in safety, performance-based, and patient-reported outcomes. This work updates the previous analysis to the current state of the published evidence. METHODS: Systematic review and meta-analysis of the effect of MPKs in limited community ambulators. RESULTS: Thirteen research projects presented in 15 publications were identified. Overall validity was "high" in nine studies, "moderate" in three, and "low" in one. The literature described a total of 2366 patients, with 704 classified as limited community ambulators. The use of MPKs in limited community ambulators led to a reduction in falls (SMD g: -0.59; 95% confidence interval (CI) [-0.85, -0.32; I2=0%]), fear of falling (SMD g: 1.2; 95%CI [0.55, 1.85; I2=80%]), risk of falling as indicated by the TUG (SMD g: -0.45, 95%CI [-0.87, -0.02; I2=0%]), an improvement in mobility grade (0.51; 95%CI [0.47,0.55]), self-selected walking speed (SMD g: 0.47; 95%CI [0.14,0.81; I2=0%]), and patient-reported ambulation (MD 9.32; 95%CI [3.61, 15.02; I2=7%]), and utility (MD 7.76; 95%CI [2.05-13.47; I2=0%]). Other outcomes exhibited trends in favor of MPK use or remained insensitive. No outcome was identified favoring non-MPKs. CONCLUSIONS: These results suggest that MPKs may be considered a valuable therapeutic option in limited community ambulators with a transfemoral amputation.Implications for rehabilitationAbove knee amputees may be treated with a large variety of artificial exo-prosthetic knee components.Microprocessor-controlled prosthetic knees have proven to be advantageous and cost effective for community ambulators.The current analysis shows similar effects in safety, mobility, and patient perception also for limited community ambulators.Microprocessor-controlled prosthetic knees are a viable therapeutic option for limited community ambulators.


Subject(s)
Amputees , Artificial Limbs , Knee Prosthesis , Humans , Prosthesis Design , Fear , Microcomputers , Walking
4.
J Rehabil Assist Technol Eng ; 8: 2055668320981355, 2021.
Article in English | MEDLINE | ID: mdl-34345438
5.
Front Rehabil Sci ; 2: 805151, 2021.
Article in English | MEDLINE | ID: mdl-36188863

ABSTRACT

Introduction: Studies with a powered prosthetic ankle-foot (PwrAF) found a reduction in sound knee loading compared to passive feet. Therefore, the aim of the present study was to determine whether anecdotal reports on reduced musculoskeletal pain and improved patient-reported mobility were isolated occurrences or reflect a common experience in PwrAF users. Methods: Two hundred and fifty individuals with transtibial amputation (TTA) who had been fitted a PwrAF in the past were invited to an online survey on average sound knee, amputated side knee, and low-back pain assessed with numerical pain rating scales (NPRS), the PROMIS Pain Interference scale, and the PLUS-M for patient-reported mobility in the free-living environment. Subjects rated their current foot and recalled the ratings for their previous foot. Recalled scores were adjusted for recall bias by clinically meaningful amounts following published recommendations. Statistical comparisons were performed using Wilcoxon's signed rank test. Results: Forty-six subjects, all male, with unilateral TTA provided data suitable for analysis. Eighteen individuals (39%) were current PwrAF users, whereas 28 subjects (61%) had reverted to a passive foot. After adjustment for recall bias, current PwrAF users reported significantly less sound knee pain than they recalled for use of a passive foot (-0.5 NPRS, p = 0.036). Current PwrAF users who recalled sound knee pain ≥4 NPRS with a passive foot reported significant and clinically meaningful improvements in sound knee pain (-2.5 NPRS, p = 0.038) and amputated side knee pain (-3 NPRS, p = 0.042). Current PwrAF users also reported significant and clinically meaningful improvements in patient-reported mobility (+4.6 points PLUS-M, p = 0.016). Individuals who had abandoned the PwrAF did not recall any differences between the feet. Discussion: Current PwrAF users reported significant and clinically meaningful improvements in patient-reported prosthetic mobility as well as sound knee and amputated side knee pain compared to recalled mobility and pain with passive feet used previously. However, a substantial proportion of individuals who had been fitted such a foot in the past did not recall improvements and had reverted to passive feet. The identification of individuals with unilateral TTA who are likely to benefit from a PwrAF remains a clinical challenge and requires further research.

6.
Article in English | MEDLINE | ID: mdl-31795365

ABSTRACT

Overhead work activities can lead to shoulder pain and serious musculoskeletal disorders (WMSD), such as rotator cuff injury and degeneration. Recently developed exoskeletons show promising results in supporting workers in such activities. In this study, a novel exoskeleton was investigated for two different overhead tasks with twelve participants. To investigate the effects of the device, electromyographic (EMG) signals of different shoulder and adjacent muscles as well as kinematic and metabolic parameters were analyzed with and without the exoskeleton. The mean EMG amplitude of all evaluated muscles was significantly reduced when the exoskeleton was used for the overhead tasks. This was accompanied by a reduction in both heart rate and oxygen rate. The kinematic analysis revealed small changes in the joint positions during the tasks. This study demonstrated the biomechanical and metabolic benefits of an exoskeleton designed to support overhead work activities. The results suggest improved physiological conditions and an unloading effect on the shoulder joint and muscles which are promising indicators that the exoskeleton may be a good solution to reduce shoulder WMSD among workers who carry out overhead tasks on a regular basis.


Subject(s)
Ergonomics/methods , Muscle, Skeletal/physiology , Shoulder Joint/physiology , Shoulder/physiology , Adult , Biomechanical Phenomena , Electromyography , Female , Humans , Male , Young Adult
8.
Prosthet Orthot Int ; 42(2): 228-235, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28691574

ABSTRACT

BACKGROUND: Despite the evidence for improved safety and function of microprocessor stance and swing-controlled prosthetic knees, non-microprocessor-controlled prosthetic knees are still standard of care for persons with transfemoral amputations in most countries. Limited feature microprocessor-control enhancement of such knees could stand to significantly improve patient outcomes. OBJECTIVES: To evaluate gait speed, balance, and fall reduction benefits of the new 3E80 default stance hydraulic knee compared to standard non-microprocessor-controlled prosthetic knees. STUDY DESIGN: Comparative within-subject clinical study. METHODS: A total of 13 young, high-functioning community ambulators with a transfemoral amputation underwent assessment of performance-based (e.g. 2-min walk test, timed ramp/stair tests) and self-reported (e.g. falls, Activities-Specific Balance Confidence scale, Prosthesis Evaluation Questionnaire question #1, Satisfaction with the Prosthesis) outcome measures for their non-microprocessor-controlled prosthetic knees and again after 8 weeks of accommodation to the 3E80 microprocessor-enhanced knee. RESULTS: Self-reported falls significantly declined 77% ( p = .04), Activities-Specific Balance Confidence scores improved 12 points ( p = .005), 2-min walk test walking distance increased 20 m on level ( p = .01) and uneven ( p = .045) terrain, and patient satisfaction significantly improved ( p < .01) when using the 3E80 knee. Slope and stair ambulation performance did not differ between knee conditions. CONCLUSION: The 3E80 knee reduced self-reported fall incidents and improved balance confidence. Walking performance on both level and uneven terrains also improved compared to non-microprocessor-controlled prosthetic knees. Subjects' satisfaction was significantly higher than with their previous non-microprocessor-controlled prosthetic knees. The 3E80 may be considered a prosthetic option for improving gait performance, balance confidence, and safety in highly active amputees. Clinical relevance This study compared performance-based and self-reported outcome measures when using non-microprocessor and a new microprocessor-enhanced, default stance rotary hydraulic knee. The results inform rehabilitation professionals about the functional benefits of a limited-feature, microprocessor-enhanced hydraulic prosthetic knee over standard non-microprocessor-controlled prosthetic knees.


Subject(s)
Accidental Falls/prevention & control , Amputation, Surgical/rehabilitation , Gait/physiology , Microcomputers/statistics & numerical data , Postural Balance/physiology , Prosthesis Design , Adult , Amputation, Surgical/methods , Artificial Limbs , Cohort Studies , Female , Femur/surgery , Follow-Up Studies , Humans , Independent Living , Knee Joint , Male , Walking Speed/physiology , Young Adult
9.
Prosthet Orthot Int ; 41(1): 65-77, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27151648

ABSTRACT

BACKGROUND: There are clear indications for benefits of stance control orthoses compared to locked knee ankle foot orthoses. However, stance control orthoses still have limited function compared with a sound human leg. OBJECTIVES: The aim of this study was to evaluate the potential benefits of a microprocessor stance and swing control orthosis compared to stance control orthoses and locked knee ankle foot orthoses in activities of daily living. STUDY DESIGN: Survey of lower limb orthosis users before and after fitting of a microprocessor stance and swing control orthosis. METHODS: Thirteen patients with various lower limb pareses completed a baseline survey for their current orthotic device (locked knee ankle foot orthosis or stance control orthosis) and a follow-up for the microprocessor stance and swing control orthosis with the Orthosis Evaluation Questionnaire, a new self-reported outcome measure devised by modifying the Prosthesis Evaluation Questionnaire for use in lower limb orthotics and the Activities of Daily Living Questionnaire. RESULTS: The Orthosis Evaluation Questionnaire results demonstrated significant improvements by microprocessor stance and swing control orthosis use in the total score and the domains of ambulation ( p = .001), paretic limb health ( p = .04), sounds ( p = .02), and well-being ( p = .01). Activities of Daily Living Questionnaire results showed significant improvements with the microprocessor stance and swing control orthosis with regard to perceived safety and difficulty of activities of daily living. CONCLUSION: The microprocessor stance and swing control orthosis may facilitate an easier, more physiological, and safer execution of many activities of daily living compared to traditional leg orthosis technologies. Clinical relevance This study compared patient-reported outcomes of a microprocessor stance and swing control orthosis (C-Brace) to those with traditional knee ankle foot orthosis and stance control orthosis devices. The C-Brace offers new functions including controlled knee flexion during weight bearing and dynamic swing control, resulting in significant improvements in perceived orthotic mobility and safety.


Subject(s)
Activities of Daily Living , Orthotic Devices , Walking/physiology , Adult , Aged , Female , Humans , Lower Extremity , Male , Microcomputers , Middle Aged , Patient Reported Outcome Measures , Postural Balance , Range of Motion, Articular
10.
Arch Orthop Trauma Surg ; 136(9): 1281-1287, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27393498

ABSTRACT

INTRODUCTION: Unloader braces are non-surgical treatment options for patients with unicompartmental knee osteoarthritis (OA). However, many patients do not adhere to brace treatment because of complications related to discomfort and poor fit. An alternative to knee bracing is an ankle-foot orthosis (AFO) with a lever arm that presses the lower leg into valgus or varus. The aim of this study is to evaluate the clinical benefits of this AFO for patients with unicompartmental knee OA. MATERIALS AND METHODS: Twenty-three patients with knee OA were enrolled in this observational study. The primary clinical outcome measure was the Western Ontario and McMasters Universities Arthritis Index (WOMAC) total score. Secondary outcome measures included WOMAC subscores, visual analogue pain scale, activity restriction and complication rate. Clinical scores were collected at start and 3, 6, 9, and 12 months after enrollment. Statistical evaluation was performed using the Student's t test. RESULTS: Of the patients enrolled, 83 % suffered from medial compartment OA. Most patients had Grade II OA according to the Kellgren and Lawrence classification. WOMAC total score, both subscores and visual analogue pain scale were significantly improved over time. Patients also noted a reduction in restrictions to activities of daily living and sport-related activities while using the AFO. No patients discontinued orthosis use because of adverse effects. Two types of complications were noted: discomfort or light pressure sores around the ankle (7 patients), and wear and tear of the shoe in which the AFO was worn (14 patients). CONCLUSIONS: This observational study suggests that this AFO is effective at significantly reducing pain and stiffness as well as improving the physical function of patients with mild to moderate unicompartmental osteoarthritis of the knee.


Subject(s)
Foot Orthoses , Osteoarthritis, Knee/therapy , Activities of Daily Living , Cohort Studies , Female , Humans , Male , Middle Aged , Osteoarthritis, Knee/classification , Pain Measurement
11.
J Rehabil Res Dev ; 51(10): 1469-96, 2014.
Article in English | MEDLINE | ID: mdl-25856664

ABSTRACT

The benefits of microprocessor-controlled prosthetic knees (MPKs) have been well established in community ambulators (Medicare Functional Classification Level [MFCL]-3) with a transfemoral amputation (TFA). A systematic review of the literature was performed to analyze whether limited community ambulators (MFCL-2) may also benefit from using an MPK in safety, performance-based function and mobility, and perceived function and satisfaction. We searched 10 scientific databases for clinical trials with MPKs and identified six publications with 57 subjects with TFA and MFCL-2 mobility grade. Using the criteria of a Cochrane Review on prosthetic components, we rated methodological quality moderate in four publications and low in two publications. MPK use may significantly reduce uncontrolled falls by up to 80% as well as significantly improve indicators of fall risk. Performance-based outcome measures suggest that persons with MFCL-2 mobility grade may be able to walk about 14% to 25% faster on level ground, be around 20% quicker on uneven surfaces, and descend a slope almost 30% faster when using an MPK. The results of this systematic review suggest that trial fittings may be used to determine whether or not individuals with TFA and MFCL-2 mobility grade benefit from MPK use. Criteria for patient selection and assessment of trial fitting success or failure are proposed.


Subject(s)
Amputees/rehabilitation , Knee Prosthesis , Microcomputers , Patient Selection , Amputees/classification , Humans , Knee Prosthesis/adverse effects , Prosthesis Design , Walking
SELECTION OF CITATIONS
SEARCH DETAIL
...