Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
2.
Clin Radiol ; 69(1): 96-102, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24268510

ABSTRACT

The complication rate following radiofrequency catheter ablation for atrial fibrillation is low (<5%). Complications include pericardial effusion, cardiac tamponade, pulmonary vein stenosis, oesophageal ulceration or perforation, atrio-oesophageal fistula formation, stroke/transient ischaemic attack, phrenic nerve injury, haematoma at the puncture site, and femoral arteriovenous fistula. Among available imaging tools, computed tomography (CT) can be very useful in diagnosing complications of the procedure, particularly in the subacute and delayed stages after ablation. This review illustrates CT imaging of several of the common and uncommon complications of radiofrequency catheter ablation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Postoperative Complications/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans
3.
Braz J Med Biol Res ; 46(11): 974-984, 2013 11.
Article in English | MEDLINE | ID: mdl-24270912

ABSTRACT

The SEARCH-RIO study prospectively investigated electrocardiogram (ECG)-derived variables in chronic Chagas disease (CCD) as predictors of cardiac death and new onset ventricular tachycardia (VT). Cardiac arrhythmia is a major cause of death in CCD, and electrical markers may play a significant role in risk stratification. One hundred clinically stable outpatients with CCD were enrolled in this study. They initially underwent a 12-lead resting ECG, signal-averaged ECG, and 24-h ambulatory ECG. Abnormal Q-waves, filtered QRS duration, intraventricular electrical transients (IVET), 24-h standard deviation of normal RR intervals (SDNN), and VT were assessed. Echocardiograms assessed left ventricular ejection fraction. Predictors of cardiac death and new onset VT were identified in a Cox proportional hazard model. During a mean follow-up of 95.3 months, 36 patients had adverse events: 22 new onset VT (mean±SD, 18.4±4/year) and 20 deaths (26.4±1.8/year). In multivariate analysis, only Q-wave (hazard ratio, HR=6.7; P<0.001), VT (HR=5.3; P<0.001), SDNN<100 ms (HR=4.0; P=0.006), and IVET+ (HR=3.0; P=0.04) were independent predictors of the composite endpoint of cardiac death and new onset VT. A prognostic score was developed by weighting points proportional to beta coefficients and summing-up: Q-wave=2; VT=2; SDNN<100 ms=1; IVET+ =1. Receiver operating characteristic curve analysis optimized the cutoff value at >1. In 10,000 bootstraps, the C-statistic of this novel score was non-inferior to a previously validated (Rassi) score (0.89±0.03 and 0.80±0.05, respectively; test for non-inferiority: P<0.001). In CCD, surface ECG-derived variables are predictors of cardiac death and new onset VT.

4.
Braz. j. med. biol. res ; 46(11): 974-984, 18/1jan. 2013. tab, graf
Article in English | LILACS | ID: lil-694028

ABSTRACT

The SEARCH-RIO study prospectively investigated electrocardiogram (ECG)-derived variables in chronic Chagas disease (CCD) as predictors of cardiac death and new onset ventricular tachycardia (VT). Cardiac arrhythmia is a major cause of death in CCD, and electrical markers may play a significant role in risk stratification. One hundred clinically stable outpatients with CCD were enrolled in this study. They initially underwent a 12-lead resting ECG, signal-averaged ECG, and 24-h ambulatory ECG. Abnormal Q-waves, filtered QRS duration, intraventricular electrical transients (IVET), 24-h standard deviation of normal RR intervals (SDNN), and VT were assessed. Echocardiograms assessed left ventricular ejection fraction. Predictors of cardiac death and new onset VT were identified in a Cox proportional hazard model. During a mean follow-up of 95.3 months, 36 patients had adverse events: 22 new onset VT (mean±SD, 18.4±4‰/year) and 20 deaths (26.4±1.8‰/year). In multivariate analysis, only Q-wave (hazard ratio, HR=6.7; P<0.001), VT (HR=5.3; P<0.001), SDNN<100 ms (HR=4.0; P=0.006), and IVET+ (HR=3.0; P=0.04) were independent predictors of the composite endpoint of cardiac death and new onset VT. A prognostic score was developed by weighting points proportional to beta coefficients and summing-up: Q-wave=2; VT=2; SDNN<100 ms=1; IVET+=1. Receiver operating characteristic curve analysis optimized the cutoff value at >1. In 10,000 bootstraps, the C-statistic of this novel score was non-inferior to a previously validated (Rassi) score (0.89±0.03 and 0.80±0.05, respectively; test for non-inferiority: P<0.001). In CCD, surface ECG-derived variables are predictors of cardiac death and new onset VT.

5.
J Interv Card Electrophysiol ; 5(1): 59-66, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11248775

ABSTRACT

The normal functioning of dual chamber pacemaker-cardioverter defibrillator (AV pacer/ICD) may be affected by oversensing of the farfield R wave (FFRW) by the atrial channel. This study aimed to investigate whether placement of the AV pacer/ICD's atrial lead at a lateral (LAT) wall location compared to a medial (MED) location i.e. the appendage of the right atrium, would reduce the amplitude of FFRWs but not the nearfield atrial electrograms (AEGMs) during sinus rhythm (SR) and ventricular fibrillation (VF). In 17 patients, real time electrograms were recorded during SR and induced VF through the atrial lead initially at the MED and subsequently at the LAT location. In 10 patients the electrograms in SR were also recorded on a computerized data acquisition and recording system at different band-pass filter settings. Although FFRWs were recorded both at MED and LAT locations, they were much smaller, 3.5+/-4.1mm during SR and 1.7+/-2.2mm during VF at the LAT location. At 30-500Hz band-pass filter, lower amplitudes of FFRWs 0.14+/-0.09 mV were recorded at the LAT location. The V/A ratios of the amplitudes of FFRWs and AEGMs were smaller at the LAT location during SR and VF. The nearfield AEGMs were of similar amplitudes at the MED and LAT locations. These data indicate that lower amplitudes of FFRWs are recorded by placement of the atrial lead at the lateral wall of the right atrium. Oversensing of FFRWs may be prevented to improve functioning of the AV pacer-ICD.


Subject(s)
Defibrillators, Implantable , Electrocardiography , Electrophysiologic Techniques, Cardiac , Pacemaker, Artificial , Aged , Electrodes , Female , Heart Atria , Humans , Male , Middle Aged
6.
Am J Cardiol ; 85(5): 593-7, 2000 Mar 01.
Article in English | MEDLINE | ID: mdl-11078273

ABSTRACT

Previous studies of the removal of implantable cardioverter defibrillator (ICD) leads have been restricted to case reports or small series. In this report, we describe our experience in ICD lead extraction by intravascular countertraction method using Cook's extraction kit. A total of 47 high-voltage (HV) leads, 3 rate sensing (S) leads, and 2 subcutaneous arrays were removed from 42 patients (33 men, 9 women; mean age 59 years [range 14 to 81]). One HV superior vena cava (SVC) lead and 11 HV right ventricular (RV) leads were explanted by manual traction only and defined in the "lead removal" category. One S lead was removed using a femoral venous approach. The remaining 37 leads were explanted by SVC approach using extraction sheaths and defined in the "lead extraction" category. Twenty leads were extracted for "infectious" (group A) and 17 leads for "noninfectious" (group B) etiologies for which extraction times of 27.0+/-18.0 and 27.0+/-15.0 minutes (mean+/-SD), respectively, were not different. Although extraction time, 34.0+/-11.0 minutes, for leads implanted for >48 months was longer than 23.0+/-16.0, 28.0+/-18.0, and 24.0+/-14.0 minutes, for leads with implant durations of 12, 24, and 48 months, respectively, such differences were not statistically significant. The extraction time, however, was directly related to the degree of fibrosis around the lead, 39.0+/-15.0 minutes for leads with severe fibrosis compared with 13.0+/-6.0 minutes for the leads with mild fibrosis (p<0.001). Patient's age, sex, or history of coronary artery bypass graft surgery did not significantly affect extraction time. All except the initial 2 lead extractions were performed in the electrophysiology laboratory. No mortality or serious complications associated with the procedure using these methods were observed.


Subject(s)
Defibrillators, Implantable , Electrodes, Implanted , Device Removal/instrumentation , Device Removal/methods , Feasibility Studies , Female , Humans , Male , Middle Aged , Safety , Time Factors
7.
Pacing Clin Electrophysiol ; 23(2): 269-72, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10709237

ABSTRACT

Atrial activation from a site in the low lateral right atrium will typically proceed in a superior direction. We present a case of a low lateral right atrial tachycardia with a surface electrocardiographic P wave morphology that appeared to have an inferiorly directed axis. The tachycardia occurred 2 years after successful atrial flutter ablation. The use of a multipolar basket catheter allowed confirmation of the focal origin of the tachycardia, permitted its rapid localization, facilitated catheter ablation, and provided clues to atrial activation that helped describe the appearance of the P wave.


Subject(s)
Cardiac Catheterization , Catheter Ablation , Heart Conduction System/physiopathology , Tachycardia, Ectopic Atrial/physiopathology , Tachycardia, Ectopic Atrial/therapy , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Catheter Ablation/instrumentation , Catheter Ablation/methods , Electrocardiography , Electrodes , Humans , Male , Middle Aged , Postoperative Complications , Tachycardia, Ectopic Atrial/pathology , Tachycardia, Sinus/pathology , Tachycardia, Sinus/physiopathology , Tachycardia, Sinus/therapy
8.
J Interv Card Electrophysiol ; 4(4): 605-10, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11141207

ABSTRACT

The exact nature of the reentry circuit for the atrioventricular nodal reentrant tachycardia (AVNRT) and particularly the concept and role of the upper and lower common pathways is not well defined. Although it is well accepted that the His-Purkinje system and the ventricles are not an essential part of the tachycardia circuit, controversy still exists as to whether the atria are essential components of the circuit. We describe a patient in whom the AVNRT perpetuated despite the spontaneous development of 2:1 anterograde and 3:2 retrograde block. To our knowledge, such a combination of electrophysiological phenomenon has not been previously reported. The electrophysiological basis of these observations and their clinical implications are discussed.


Subject(s)
Electrocardiography , Heart Block/complications , Heart Block/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/complications , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Cardiac Catheterization , Cardiac Pacing, Artificial/methods , Female , Follow-Up Studies , Heart Block/therapy , Humans , Isoproterenol , Middle Aged , Tachycardia, Atrioventricular Nodal Reentry/therapy
9.
Cardiology ; 91(4): 264-7, 1999.
Article in English | MEDLINE | ID: mdl-10545683

ABSTRACT

Williams syndrome is characterized by a constellation of features including mental retardation and supravalvular aortic stenosis. Other cardiovascular abnormalities including arrhythmias contributing to sudden death have been described in these patients. In this report we describe a case of a 49-year-old female with Williams syndrome who presented with severe symptomatic supraventricular tachycardia. Cardiac electrophysiology study identified a left posteroseptal concealed accessory bypass tract responsible for atrioventricular reentrant tachycardia and a concomitant typical atrioventricular nodal tachycardia. Such unusual association of combination of two different types of supraventricular tachycardia and Williams syndrome has not been previously reported. Radiofrequency ablation was successfully performed to cure these arrhythmias.


Subject(s)
Atrioventricular Node/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/etiology , Tachycardia, Supraventricular/etiology , Williams Syndrome/complications , Catheter Ablation , Electrocardiography , Female , Heart Conduction System/physiopathology , Humans , Middle Aged , Syncope/etiology , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Paroxysmal/etiology , Tachycardia, Supraventricular/surgery , Williams Syndrome/physiopathology
10.
J Interv Card Electrophysiol ; 3(3): 283-5, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10490487

ABSTRACT

Patients with orthotopic heart transplantation may develop a variety of arrhythmias. Successful radiofrequency catheter ablation for tachyarrhythmias from manifest and concealed accessory bypass tracts in transplant patients has been previously reported. We present a patient with orthotopic heart transplantation who developed typical atrioventricular nodal tachycardia, which was successfully treated by radiofrequency catheter ablation.


Subject(s)
Atrioventricular Node/surgery , Catheter Ablation , Heart Transplantation/adverse effects , Tachycardia, Atrioventricular Nodal Reentry/surgery , Aged , Atrioventricular Node/physiopathology , Electrocardiography , Heart Rate , Humans , Male , Tachycardia, Atrioventricular Nodal Reentry/etiology , Tachycardia, Atrioventricular Nodal Reentry/physiopathology
11.
Curr Opin Cardiol ; 14(1): 44-51, 1999 Jan.
Article in English | MEDLINE | ID: mdl-9932207

ABSTRACT

The common reasons for removal of pacing and defibrillator leads are infection, malfunction, or design defects such as fracture of J wires in Teletronics Accufix leads (Telectronics Pacing, Englewood, CO), which impose considerable risk for cardiac morbidity and mortality. Chronically implanted leads are fixed to the myocardium by fibrous tissue. Fibrous scar tissue may also encase the lead along its course. Furthermore, fragility of the lead and its tendency to break when extraction force is applied to overcome resistance imparted by the scar tissue add to the challenge of lead extraction. Thus, the extraction of chronically implanted leads is an important issue. Until a few years ago, the only methods available for the removal of chronically implanted leads were traction on the proximal segment of the lead and cardiac surgery. New techniques were developed to extract the leads by a transvenous approach using locking stylets, sheaths, snares, and retrieval baskets. Lead extraction using intravascular countertraction methods has since evolved as a specialty of its own. Progress has also been made in developing other system, such as Excimer laser energy for lead extraction. In this article, we discuss principles, techniques, and experience with these methods of extraction of chronic pacemaker and defibrillator leads.


Subject(s)
Cardiac Surgical Procedures , Defibrillators, Implantable , Electrodes , Defibrillators, Implantable/adverse effects , Electrodes/adverse effects , Equipment Failure , Humans , Vena Cava, Inferior/surgery , Vena Cava, Superior/surgery
12.
Am J Cardiol ; 76(3): 144-7, 1995 Jul 15.
Article in English | MEDLINE | ID: mdl-7611148

ABSTRACT

Transesophageal atria pacing (TEAP) using a pill electrode was performed in 49 patients with atrial flutter. The responses observed were (1) immediate sinus rhythm in 17 (35%), (2) delayed sinus rhythm in 13 (27%), (3) atrial fibrillation in 11 (22%), and (4) no success in 8 (16%) patients. Sinus rhythm was thus restored in 30 patients (61%). In group A, 12 of 17 patients (p < 0.05) had coronary artery disease. The patients in group D had echocardiographic evidence of right atrial enlargement (2.56 +/- 0.29 cm, p = 0.007), left atrial enlargement (4.6 +/- 0.12 cm, p < 0.0001), right ventricular dilatation (3.41 +/- 0.45 cm, p < 0.05), left ventricular dilatation (6.39 +/- 0.66 cm, p < 0.05), and depressed left ventricular ejection fraction (32 +/- 7%, p < 0.05). Optimal pacing rate (375 +/- 54 beats/min) was 41% higher than the mean atrial flutter rate (266 +/- 37 beats/min) for cardioversion to immediate sinus rhythm. Pacing current strength and the pulse width had no influence on the final outcome. On the basis of the result of the initial attempt, patients undergoing TEAP repetitively had an almost predictably similar outcome on the subsequent attempts. Thus, normal sinus rhythm could be resumed in most patients with atrial flutter by TEAP. It does not require general anesthesia and can be performed even in patients who have undergone digitalization, when a direct-current countershock may be of some concern.


Subject(s)
Atrial Flutter/therapy , Cardiac Pacing, Artificial/methods , Aged , Aged, 80 and over , Atrial Flutter/physiopathology , Cardiac Pacing, Artificial/statistics & numerical data , Chi-Square Distribution , Electrocardiography/statistics & numerical data , Electrodes , Esophagus , Female , Heart Rate , Humans , Male , Middle Aged , Pacemaker, Artificial/statistics & numerical data , Prognosis , Prospective Studies , Treatment Outcome
14.
Am J Med Sci ; 306(4): 233-5, 1993 Oct.
Article in English | MEDLINE | ID: mdl-8213891

ABSTRACT

Hepatocellular carcinoma is an uncommon cancer in the United States. Its initial presentation as spinal cord compression due to vertebral metastasis is rare. This article reports a case of radiculopathy and rapidly developing spinal cord compression because of bony metastasis from this form of liver cancer. This article also reviews pertinent literature and discusses the diagnostic modalities for early detection.


Subject(s)
Carcinoma, Hepatocellular/complications , Carcinoma, Hepatocellular/secondary , Spinal Cord Compression/etiology , Spinal Neoplasms/complications , Spinal Neoplasms/secondary , Thoracic Vertebrae , Humans , Liver Neoplasms/pathology , Male , Middle Aged
15.
Br J Rheumatol ; 30(4): 251-4, 1991 Aug.
Article in English | MEDLINE | ID: mdl-1863820

ABSTRACT

One hundred patients who presented to an Early Synovitis Clinic in 1979-81 were called for review after a minimum of 5 years. Sufficient data for analysis were obtained in 88 cases, of whom 36 had a final diagnosis of rheumatoid arthritis (19 seropositive, 17 seronegative) and 16 human parvovirus B19 arthropathy. Outcome was assessed by persistence of symptoms greater than 24 months and functional disability by Health Assessment Questionnaire. Sixty-two patients had persistent disease, with 26 showing some functional impairment (positive HAQ FDI). A number of presenting features were assessed for their ability to predict outcome at 5 years. Polyarticular onset of disease was associated with a poor prognosis but lacked both specificity and sensitivity. Certain laboratory tests at presentation, including positive rheumatoid factor and low serum sulphydryl levels, also indicated a poor outcome. Combining these serological abnormalities gave 100% specificity for detecting persistent, disabling disease but with rather low sensitivity. Thus, other test systems are required to increase further the successful prediction of clinical outcome in patients with early synovitis.


Subject(s)
Synovitis/physiopathology , Adolescent , Adult , Disability Evaluation , Female , Follow-Up Studies , Forecasting , Hand/diagnostic imaging , Health Status , Humans , Male , Middle Aged , Radiography , Rheumatoid Factor/analysis , Sulfhydryl Compounds/blood , Surveys and Questionnaires , Synovitis/blood , Synovitis/diagnostic imaging , Time Factors
16.
Br J Clin Pract ; 45(2): 146-7, 1991.
Article in English | MEDLINE | ID: mdl-1793702

ABSTRACT

Although hepatosplenic schistosomiasis is the commonest cause of liver disease worldwide, the diagnosis is not often considered in European countries. A case of Schistosomiasis mansoni complicated by portal hypertension is reported to demonstrate how diseases endemic to an immigrant's homeland can present many years later in non-endemic countries.


Subject(s)
Hypertension, Portal/etiology , Liver Diseases, Parasitic/complications , Schistosomiasis mansoni/complications , Splenic Diseases/complications , Adult , Chronic Disease , Female , Humans
17.
Br J Rheumatol ; 28(2): 118-23, 1989 Apr.
Article in English | MEDLINE | ID: mdl-2650797

ABSTRACT

A randomized control trial of TP-5 in rheumatoid arthritis is reported. In a multicentre study, 76 patients were treated with TP-5 50 mg or placebo three times a week for 3 weeks as a slow intravenous injection, and followed for 7 weeks. Clinical parameters such as the Ritchie index and sum score of swollen joints improved significantly on TP-5 compared to placebo. Laboratory parameters did not change but an increased skin test score to common recall antigens was observed. Toxicity was minimal. TP-5 is a potentially useful agent in the treatment of rheumatoid arthritis, although further studies are required to determine the optimal treatment regimen.


Subject(s)
Arthritis, Rheumatoid/drug therapy , Peptide Fragments/therapeutic use , Thymopoietins/therapeutic use , Thymus Hormones/therapeutic use , Arthritis, Rheumatoid/blood , Arthritis, Rheumatoid/physiopathology , Clinical Trials as Topic , Humans , Hypersensitivity, Delayed/immunology , Peptide Fragments/adverse effects , Severity of Illness Index , Skin Tests , T-Lymphocytes/classification , Thymopentin , Thymopoietins/adverse effects
19.
SELECTION OF CITATIONS
SEARCH DETAIL
...