Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Waste Manag Res ; 34(2): 165-70, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26526019

ABSTRACT

The novelty of this study is to rapidly reduce hazardous lead leachates from solid waste using microwave digestion treatment, which is an energy-saving and low greenhouse gas emission technology. The article presents the reduction of toxic characteristic leaching procedure-extractable lead concentration in the municipal solid waste incineration fly ash by the microwave digestion treatment in HNO3/H2SO4 combination, and focuses on the effects of treatment time and temperature. The results obtained from this study indicated a significant reduction efficiency of toxic characteristic leaching procedure-extractable lead concentration and showed sufficient reduction in leaching levels to render the treated fly ash safe in lead compound leaching characteristics. The reduction efficiency of toxic characteristic leaching procedure-extractable lead concentration can reach 98% in 15 minutes of treatment time. This is equivalent to the original toxic characteristic leaching procedure-extractable lead concentration of 46.2 mg L(-1) in raw fly ash being reduced down to less than 1.0 mg L(-1). Based on the experimental data obtained in this study, a useful correlation between reduction efficiency and treatment conditions is proposed. For engineering applications, the necessary minimum treatment time is solved using a graphic illustration method, by which the minimum treatment time (t(min)) is obtained if the desired reduction efficiency (η) and treatment temperature (T) are known. The effects of treatment time and temperature are discussed. Some problems caused by the microwave digestion treatment method are also delineated in this article.


Subject(s)
Environmental Pollutants/chemistry , Lead/chemistry , Microwaves , Recycling/methods , Solid Waste/analysis , Waste Management/methods , Coal Ash/chemistry , Environmental Pollutants/radiation effects , Incineration , Lead/radiation effects
2.
Bull Environ Contam Toxicol ; 96(1): 102-6, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26611368

ABSTRACT

This study determined the influence of emerging industries development on molybdenum (Mo) groundwater contamination. A total of 537 groundwater samples were collected for Mo determination, including 295 samples from potentially contaminated areas of 3 industrial parks in Taiwan and 242 samples from non-potentially contaminated areas during 2008-2014. Most of the high Mo samples are located downstream from a thin film transistor-liquid crystal display (TFT-LCD) panel factory. Mean groundwater Mo concentrations from potentially contaminated areas (0.0058 mg/L) were significantly higher (p < 0.05) than those from non-potentially contaminated areas (0.0022 mg/L). The highest Mo wastewater concentrations in the effluent from the optoelectronics industry and following wastewater batch treatment were 0.788 and 0.0326 mg/L, respectively. This indicates that wastewater containing Mo is a possible source of both groundwater and surface water contamination. Nine samples of groundwater exceed the World Health Organization's suggested drinking water guideline of 0.07 mg/L. A non-carcinogenic risk assessment for Mo in adults and children using the Mo concentration of 0.07 mg/L yielded risks of 0.546 and 0.215, respectively. These results indicate the importance of the development of a national drinking water quality standard for Mo in Taiwan to ensure safe groundwater for use. According to the human health risk calculation, the groundwater Mo standard is suggested as 0.07 mg/L. Reduction the discharge of Mo-contaminated wastewater from factories in the industrial parks is also the important task in the future.


Subject(s)
Groundwater/chemistry , Molybdenum/analysis , Water Pollutants, Chemical/analysis , Adult , Child , Drinking Water/standards , Humans , Industrial Waste , Risk Assessment , Taiwan , Wastewater
3.
Environ Technol ; 36(5-8): 675-80, 2015.
Article in English | MEDLINE | ID: mdl-25176128

ABSTRACT

Microwave peroxide oxidation is a less greenhouse gas emission and energy-efficient technology to destroy toxic organic compounds in hazardous waste. The research novelty is to adopt the innovative microwave peroxide oxidation in H2SO4/HNO3 solution to efficiently destroy the polychlorinated dibenzo-p-dioxins (PCDDs)/Fs in municipal solid waste incineration fly ash. The major objective of this paper is to study dynamic destruction of PCDDs/Fs using the microwave peroxide oxidation. Almost all PCDDs/Fs in the raw fly ash can be destructed in 120 min at a temperature of 423 K using the microwave peroxide oxidation treatment. It was found that the microwave peroxide oxidation provides the potential to destruct the PCDDs/Fs content in municipal solid waste incinerator (MSWI) fly ash to a low level as a function of treatment time. A useful kinetic correlation between destruction efficiency and treatment conditions is proposed on the basis of the experimental data obtained in this study. The significance of this work in terms of practical engineering applications is that the necessary minimum treatment time can be solved using a proposed graphic illustration method, by which the minimum treatment time is obtained if the desired destruction efficiency and treatment temperature are known. Because of inorganic salt dissolution, the temperature would be a critical factor facilitating the parts of fly ash dissolution. Material loss problem caused by the microwave peroxide oxidation and the effects of treatment time and temperature are also discussed in this paper.


Subject(s)
Benzofurans/chemistry , Peroxides/chemistry , Polychlorinated Dibenzodioxins/analogs & derivatives , Benzofurans/radiation effects , Coal Ash , Dibenzofurans, Polychlorinated , Incineration , Kinetics , Microwaves , Polychlorinated Dibenzodioxins/chemistry , Polychlorinated Dibenzodioxins/radiation effects
4.
Chemosphere ; 91(6): 864-8, 2013 May.
Article in English | MEDLINE | ID: mdl-23453433

ABSTRACT

Microwave peroxide oxidation (MPO) is an energy-efficient and low GHG emission technology to destroy the hazardous organic compounds in solid waste. The objective of this paper is to explore the reduction feasibility of PCDDs/Fs in MSWI fly ash using the MPO in H2SO4/HNO3 solution. Nearly all PCDDs/Fs, 99% in the original fly ash, can be reduced in 120min at the temperature of 150°C using the MPO treatment. It was also found that a change occurred in the content distribution profiles of 17 major PCDD/F congeners before and after MPO treatment. This provides the potential to reduce the actual PCDDs/Fs content more than I-TEQ contents of PCDDs/Fs. The percentile distribution profile has a tendency of higher chlorinated PCDDs/Fs moving to the lower ones. It concludes that a significant reduction efficiency of I-TEQ toxicity was achieved and showed sufficient reduction of toxic level to lower than 1.0ngI-TEQ(gdw)(-1). The treatment temperature would be a critical factor facilitating the dissolution because higher temperature leads more inorganic salt (parts of fly ash) dissolution. Some problems caused by the MPO method are also delineated in this paper.


Subject(s)
Benzofurans/chemistry , Coal Ash/chemistry , Nitric Acid/chemistry , Peroxides/chemistry , Polychlorinated Dibenzodioxins/analogs & derivatives , Refuse Disposal/methods , Sulfuric Acids/chemistry , Benzofurans/isolation & purification , Cities , Dibenzofurans, Polychlorinated , Environmental Pollutants/chemistry , Environmental Pollutants/isolation & purification , Feasibility Studies , Microwaves , Oxidation-Reduction , Polychlorinated Dibenzodioxins/chemistry , Polychlorinated Dibenzodioxins/isolation & purification , Solutions
5.
J Hazard Mater ; 144(1-2): 292-9, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17110023

ABSTRACT

Kaolins contaminated with heavy metals, Cu and Pb, and organic compounds, p-xylene and phenanthrene, were treated with an upward electrokinetic soil remediation (UESR) process. The effects of current density, cathode chamber flushing fluid, treatment duration, reactor size, and the type of contaminants under the vertical non-uniform electric field of UESR on the simultaneous removal of the heavy metals and organic contaminants were studied. The removal efficiencies of p-xylene and phenanthrene were higher in the experiments with cells of smaller diameter or larger height, and with distilled water flow in the cathode chamber. The removal efficiency of Cu and Pb were higher in the experiments with smaller diameter or shorter height cells and 0.01M HNO(3) solution as cathode chamber flow. In spite of different conditions for removal of heavy metals and organics, it is possible to use the upward electrokinetic soil remediation process for their simultaneous removal. Thus, in the experiments with duration of 6 days removal efficiencies of phenanthrene, p-xylene, Cu and Pb were 67%, 93%, 62% and 35%, respectively. The experiment demonstrated the feasibility of simultaneous removal of organic contaminants and heavy metals from kaolin using the upward electrokinetic soil remediation process.


Subject(s)
Copper/chemistry , Environmental Restoration and Remediation/methods , Lead/chemistry , Phenanthrenes/chemistry , Soil Pollutants/chemistry , Xylenes/chemistry , Electrochemistry , Kaolin/chemistry
6.
J Hazard Mater ; 136(3): 532-41, 2006 Aug 25.
Article in English | MEDLINE | ID: mdl-16504386

ABSTRACT

An upward electrokinetic soil remedial (UESR) technology was proposed to remove heavy metals from contaminated kaolin. Unlike conventional electrokinetic treatment that uses boreholes or trenches for horizontal migration of heavy metals, the UESR technology, applying vertical non-uniform electric fields, caused upward transportation of heavy metals to the top surface of the treated soil. The effects of current density, treatment duration, cell diameter, and different cathode chamber influent (distilled water or 0.01 M nitric acid) were studied. The removal efficiencies of heavy metals positively correlated to current density and treatment duration. Higher heavy metals removal efficiency was observed for the reactor cell with smaller diameter. A substantial amount of heavy metals was accumulated in the nearest to cathode 2 cm layer of kaolin when distilled water was continuously supplied to the cathode chamber. Heavy metals accumulated in this layer of kaolin can be easily excavated and disposed off. The main part of the removed heavy metals was dissolved in cathode chamber influent and moved away with cathode chamber effluent when 0.01 M nitric acid was used, instead of distilled water. Energy saving treatment by UESR technology with highest metal removal efficiencies was provided by two regimes: (1) by application of 0.01 M nitric acid as cathode chamber influent, cell diameter of 100 mm, duration of 18 days, and constant voltage of 3.5 V (19.7 k Wh/m(3) of kaolin) and (2) by application of 0.01 M nitric acid as cathode chamber influent, cell diameter of 100 cm, duration of 6 days, and constant current density of 0.191 mA/cm(2) (19.1 k Wh/m(3) of kaolin).


Subject(s)
Environmental Restoration and Remediation , Kaolin/chemistry , Metals, Heavy/isolation & purification , Soil Pollutants/analysis , Algorithms , Electrochemistry , Electrodes , Energy Transfer , Hydrogen-Ion Concentration
SELECTION OF CITATIONS
SEARCH DETAIL
...