Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 959
Filter
2.
Article in English | MEDLINE | ID: mdl-38837174

ABSTRACT

Background: Cerebral embolic protection devices (EPDs) were developed to mitigate the risk of stroke during transcatheter aortic valve replacement (TAVR), but their benefit remains unproven. In the PROTECTED-TAVR trial, EPD use did not reduce periprocedural stroke (primary study outcome) but led to a 62% reduction in the secondary endpoint of disabling stroke. Given these results, the impact of EPDs during TAVR remains unclear. Methods: We used STS/ACC TVT registry data to examine the association between EPD use and a proxy for disabling stroke among transfemoral TAVR patients between 1/2018-6/2023. The primary outcome was in-hospital disabling stroke-defined as stroke associated with either in-hospital death or discharge to a non-home location. We evaluated the association between EPD use and disabling stroke using instrumental variable (IV) analysis with site-level preference for EPD use as the instrument-a quasi-experimental approach that can support causal inference. In addition, we performed a propensity-score based comparison using overlap weighting as a secondary analysis. Results: The study population consisted of 414,649 patients of whom 53,389 (12.9%) received an EPD. The unadjusted rate of in-hospital disabling stroke was 0.7% among the EPD group and 0.9% in the no EPD group. EPD use was associated with a reduction in disabling stroke in both IV analysis (RR 0.87; 95% CI: 0.73-1.00) and propensity-weighted (PW) analysis (OR 0.79; 95% CI: 0.70-0.90) but was not associated with a reduction in non-disabling stroke. In subgroup analyses, the benefit of EPD was greater among those with versus without prior stroke (interaction p<0.05 for IV and PW). Conclusions: In the largest study to date, among patients undergoing TAVR, EPD use was associated with a small, borderline significant reduction in stroke associated with death or a discharge to a non-home location (a proxy for disabling stroke) that is likely to be causal in nature. Taken together with previous mechanistic and clinical studies, these findings provide credible evidence that EPDs benefit patients undergoing TAVR.

3.
Circ Cardiovasc Interv ; : e013842, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708595

ABSTRACT

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.

4.
Article in English | MEDLINE | ID: mdl-38693866

ABSTRACT

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

5.
Europace ; 2024 May 04.
Article in English | MEDLINE | ID: mdl-38703375

ABSTRACT

BACKGROUND AND AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors of MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS: The multicenter retrospective cohort study included 2,668 patients (age 63.1±13.0 y; 23% female; 78% white; 43% nonischemic cardiomyopathy, left ventricular ejection fraction 28.2±11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and ECG metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. RESULTS: During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate ICD therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa (HR 1.16; 95%CI 1.01-1.34), larger SVGel (HR 1.17; 95%CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95%CI 0.63-0.86) and SAIQRST (HR 0.84; 95%CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT (ROC(t)AUC 0.728; 95%CI 0.668-0.788) identified high-risk (> 50%) patients with 75% sensitivity, 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95%CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future RCTs of prophylactic VT ablation.

6.
Article in English | MEDLINE | ID: mdl-38795108

ABSTRACT

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

8.
Circ Cardiovasc Interv ; : e013558, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38785079

ABSTRACT

BACKGROUND: Elevated aortic valve gradients are common after transcatheter aortic valve implantation for degenerated surgical aortic valve replacement bioprostheses, but their clinical impact is uncertain. METHODS: A total of 12 122 patients who underwent transcatheter aortic valve implantation-in-surgical aortic valve replacement from November 2011 to December 2019 in the Society of Thoracic Surgery/American College of Cardiology Transvalvular Therapeutics Registry were included. The primary outcome was a composite of 1-year all-cause mortality, stroke, myocardial infarction, or valve reintervention. Secondary outcomes included 1-year all-cause mortality, readmission, and change from baseline 12-question self-administered Kansas City Cardiomyopathy Questionnaire-Overall Summary Score. Due to nonlinearity observed with restricted cubic splines analysis, a Cox regression analysis with aortic valve mean gradient modeled as a spline-continuous variable (with 20 mm Hg as a cutoff) was used to study the 1-year composite outcome and mortality. RESULTS: The composite outcome occurred most frequently in patients with aortic valve mean gradient ≥30 and <10 mm Hg, as compared with those with 10 to 20 and 20 to 30 mm Hg ranges (unadjusted rates, 13.9%, 12.1%, 7.5%, and 6.5%, respectively; P=0.002). When the mean aortic valve gradient was ≥20 mm Hg, higher gradients were associated with greater risk of the 1-year composite outcome (adjusted hazard ratio, 1.02 [1.02-1.03] per mm Hg; P<0.001) and 1-year mortality (adjusted hazard ratio, 1.02 [1.00-1.03] per mm Hg; P=0.007). Whereas when the mean aortic valve gradient was <20 mm Hg, higher gradients were not significantly associated with the composite outcome (adjusted hazard ratio, 0.99 [0.98-1.003] per mm Hg; P=0.12) but were associated with lower 1-year mortality (adjusted hazard ratio, 0.98 [0.97-0.99] per mm Hg; P=0.007). CONCLUSIONS: The relationship between postprocedural aortic valve mean gradient after transcatheter aortic valve implantation-in-surgical aortic valve replacement and clinical outcomes is complex and nonlinear, with relatively greater adverse events occurring at low and high gradient extremes. Further study of factors mediating the relationship between postprocedural gradients and clinical outcomes, including low-flow states, is necessary.

9.
Open Heart ; 11(1)2024 May 20.
Article in English | MEDLINE | ID: mdl-38769066

ABSTRACT

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
10.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38761069

ABSTRACT

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Subject(s)
Aortic Valve Stenosis , Severity of Illness Index , Shock, Cardiogenic , Transcatheter Aortic Valve Replacement , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Retrospective Studies , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Risk Factors , Time Factors , Incidence
11.
Circ Cardiovasc Imaging ; 17(4): e016006, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38626097

ABSTRACT

BACKGROUND: Significant controversy continues to confound patient selection and referral for revascularization and mitral valve intervention in patients with ischemic cardiomyopathy (ICM). Cardiac magnetic resonance (CMR) enables comprehensive phenotyping with gold-standard tissue characterization and volumetric/functional measures. Therefore, we sought to determine the impact of CMR-enriched phenomapping patients with ICM to identify differential outcomes following surgical revascularization and surgical mitral valve intervention (sMVi). METHODS: Consecutive patients with ICM referred for CMR between 2002 and 2017 were evaluated. Latent class analysis was performed to identify phenotypes enriched by comprehensive CMR assessment. The primary end point was death, heart transplant, or left ventricular assist device implantation. A multivariable Cox survival model was developed to determine the association of phenogroups with overall survival. Subgroup analysis was performed to assess the presence of differential response to post-magnetic resonance imaging procedural interventions. RESULTS: A total of 787 patients were evaluated (63.0±11.2 years, 24.8% women), with 464 primary events. Subsequent surgical revascularization and sMVi occurred in 380 (48.3%) and 157 (19.9%) patients, respectively. Latent class analysis identified 3 distinct clusters of patients, which demonstrated significant differences in overall outcome (P<0.001). Latent class analysis identified differential survival benefit of revascularization in patients as well as patients who underwent revascularization with sMVi, based on phenogroup classification, with phenogroup 3 deriving the most survival benefit from revascularization and revascularization with sMVi (hazard ratio, 0.61 [0.43-0.88]; P=0.0081). CONCLUSIONS: CMR-enriched unsupervised phenomapping identified distinct phenogroups, which were associated with significant differential survival benefit following surgical revascularization and sMVi in patients with ICM. Phenomapping provides a novel approach for patient selection, which may enable personalized therapeutic decision-making for patients with ICM.


Subject(s)
Cardiomyopathies , Myocardial Ischemia , Humans , Female , Male , Myocardial Ischemia/complications , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/surgery , Magnetic Resonance Imaging/methods , Treatment Outcome , Mitral Valve , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/therapy , Cardiomyopathies/complications
12.
JAMA Cardiol ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630494

ABSTRACT

Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants: This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions: Atrial shunt device or sham control. Main Outcome Measures: Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results: The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, -5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, -2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs -1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance: In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration: ClinicalTrials.gov Identifier: NCT03088033.

13.
JAMA Cardiol ; 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38581644

ABSTRACT

Importance: Aortic stenosis (AS) is a major public health challenge with a growing therapeutic landscape, but current biomarkers do not inform personalized screening and follow-up. A video-based artificial intelligence (AI) biomarker (Digital AS Severity index [DASSi]) can detect severe AS using single-view long-axis echocardiography without Doppler characterization. Objective: To deploy DASSi to patients with no AS or with mild or moderate AS at baseline to identify AS development and progression. Design, Setting, and Participants: This is a cohort study that examined 2 cohorts of patients without severe AS undergoing echocardiography in the Yale New Haven Health System (YNHHS; 2015-2021) and Cedars-Sinai Medical Center (CSMC; 2018-2019). A novel computational pipeline for the cross-modal translation of DASSi into cardiac magnetic resonance (CMR) imaging was further developed in the UK Biobank. Analyses were performed between August 2023 and February 2024. Exposure: DASSi (range, 0-1) derived from AI applied to echocardiography and CMR videos. Main Outcomes and Measures: Annualized change in peak aortic valve velocity (AV-Vmax) and late (>6 months) aortic valve replacement (AVR). Results: A total of 12 599 participants were included in the echocardiographic study (YNHHS: n = 8798; median [IQR] age, 71 [60-80] years; 4250 [48.3%] women; median [IQR] follow-up, 4.1 [2.4-5.4] years; and CSMC: n = 3801; median [IQR] age, 67 [54-78] years; 1685 [44.3%] women; median [IQR] follow-up, 3.4 [2.8-3.9] years). Higher baseline DASSi was associated with faster progression in AV-Vmax (per 0.1 DASSi increment: YNHHS, 0.033 m/s per year [95% CI, 0.028-0.038] among 5483 participants; CSMC, 0.082 m/s per year [95% CI, 0.053-0.111] among 1292 participants), with values of 0.2 or greater associated with a 4- to 5-fold higher AVR risk than values less than 0.2 (YNHHS: 715 events; adjusted hazard ratio [HR], 4.97 [95% CI, 2.71-5.82]; CSMC: 56 events; adjusted HR, 4.04 [95% CI, 0.92-17.70]), independent of age, sex, race, ethnicity, ejection fraction, and AV-Vmax. This was reproduced across 45 474 participants (median [IQR] age, 65 [59-71] years; 23 559 [51.8%] women; median [IQR] follow-up, 2.5 [1.6-3.9] years) undergoing CMR imaging in the UK Biobank (for participants with DASSi ≥0.2 vs those with DASSi <.02, adjusted HR, 11.38 [95% CI, 2.56-50.57]). Saliency maps and phenome-wide association studies supported associations with cardiac structure and function and traditional cardiovascular risk factors. Conclusions and Relevance: In this cohort study of patients without severe AS undergoing echocardiography or CMR imaging, a new AI-based video biomarker was independently associated with AS development and progression, enabling opportunistic risk stratification across cardiovascular imaging modalities as well as potential application on handheld devices.

14.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
15.
Open Heart ; 11(1)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38663889

ABSTRACT

OBJECTIVES: We sought to determine the relationship between the degree of left ventricular ejection fraction (LVEF) impairment and the frequency and type of bleeding events after percutaneous coronary intervention (PCI). DESIGN: This was an observational retrospective cohort analysis. Patients who underwent PCI from 2009 to 2017 were identified from our institutional National Cardiovascular Disease Registry (NCDR) CathPCI database. Patients were stratified by pre-PCI LVEF: preserved (≥50%), mildly reduced (41%-49%) and reduced (≤40%) LVEF. PRIMARY OUTCOME MEASURES: The outcome was major bleeding, defined by NCDR criteria. Events were classified based on bleeding aetiology and analysed by multivariable logistic regression. RESULTS: Among 13 537 PCIs, there were 817 bleeding events (6%). The rate of bleeding due to any cause, blood transfusion, gastrointestinal bleeding and coronary artery perforation or tamponade each increased in a stepwise fashion comparing preserved, mildly reduced and reduced LVEF reduction (p<0.05 for all comparisons). However, there were no differences in bleeding due to asymptomatic drops in haemoglobin, access site haematoma or retroperitoneal bleeding. After multivariable adjustment, mildly reduced and reduced LVEF remained independent predictors of bleeding events (OR 1.36, 95% CI 1.06 to 1.74, p<0.05 and OR 1.73, 95% CI 1.45 to 2.06, p<0.0001). CONCLUSIONS: The degree of LV dysfunction is an independent predictor of post-PCI major bleeding events. Patients with mildly reduced or reduced LVEF are at greatest risk of post-PCI bleeding, driven by an increased need for blood transfusion, major GI bleeding events and coronary artery perforation or tamponade. Pre-PCI LV dysfunction does not predict asymptomatic declines in haemoglobin, access site haematoma or retroperitoneal bleeding.


Subject(s)
Heart Failure , Percutaneous Coronary Intervention , Registries , Stroke Volume , Ventricular Function, Left , Humans , Percutaneous Coronary Intervention/adverse effects , Male , Female , Retrospective Studies , Stroke Volume/physiology , Aged , Heart Failure/physiopathology , Heart Failure/diagnosis , Heart Failure/therapy , Ventricular Function, Left/physiology , Risk Factors , Middle Aged , Risk Assessment/methods , Incidence , United States/epidemiology , Treatment Outcome , Coronary Artery Disease/complications , Coronary Artery Disease/physiopathology , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Follow-Up Studies , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/diagnosis , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/epidemiology , Postoperative Hemorrhage/diagnosis , Time Factors
16.
Article in English | MEDLINE | ID: mdl-38641438

ABSTRACT

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

17.
JACC Case Rep ; 29(6): 102238, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38549857

ABSTRACT

Cardiac tumors of the left ventricle are rare, and cardiac magnetic resonance is the preferred imaging tool for evaluation given superior tissue characterization. We present a case of a patient with arrhythmia and left ventricular mass that was ultimately diagnosed with cardiac sarcoidosis, reminding us that tissue is the issue.

18.
Am J Cardiol ; 217: 86-93, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38432333

ABSTRACT

Low muscle mass (LMM) is associated with worse outcomes in various clinical situations. Traditional frailty markers have been used for preoperative risk stratification in patients who underwent transcatheter aortic valve replacement (TAVR). However, preoperative imaging provides an opportunity to directly quantify skeletal muscle mass to identify patients at higher risk of procedural complications. We reviewed all TAVR recipients from January to December 2018 and included subjects with preprocedural chest computed tomography. Multi-slice automated measurements of skeletal muscle mass were made from the ninth to twelfth thoracic vertebrae and normalized by height squared to obtain skeletal muscle index (cm2/m2). LMM was defined as the lowest gender-stratified skeletal muscle index tertile. Strength testing was collected during pre-TAVR evaluation. Primary outcome was a composite of perioperative complications, 1-year rehospitalization, or 1-year mortality. In our cohort, 238 patients met inclusion criteria, and 80 (33.6%) were identified to have LMM. Patients with LMM were older with lower body mass index, decreased grip strength, lower hemoglobin A1c, and higher N-terminal pro-brain natriuretic peptide. They had greater rates of the composite outcome and 2-year all-cause mortality, which remained significant on multivariable adjustment (hazard ratio 1.71, 95% confidence interval 1.05 to 2.78, p = 0.030 and hazard ratio 2.31, 95% confidence interval 1.02 to 5.24, p = 0.045, respectively) compared with patients without LMM; there was no significant difference in 5-year all-cause mortality. In conclusion, LMM was associated with an increase in the primary composite outcome and 2-year all-cause mortality in TAVR recipients. Using automatic muscle processing software on pre-TAVR computed tomography scans may serve as an additional preoperative risk stratification tool.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve Stenosis/complications , Tomography, X-Ray Computed/methods , Muscle, Skeletal/diagnostic imaging , Aortic Valve/surgery , Risk Factors
19.
Interv Cardiol Clin ; 13(2): 249-255, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38432767

ABSTRACT

Functional mitral regurgitation (FMR) is a common valvular heart disease in the geriatric population across the United States. This patient cohort is multimorbid and often has a prohibitive risk for conventional open-heart surgery. The diverse anatomic pathology of FMR is a complex problem and unfortunately does not have a universal solution. Carillon Mitral Contour System (Cardiac Dimensions, Kirkland, WA, USA) is a new device that provides transcatheter annular remodeling. In this review article, the authors summarize the evidence for the Carillon Mitral Contour System for FMR.


Subject(s)
Heart Valve Diseases , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Aged , Humans , Mitral Valve Insufficiency/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...