J Med Phys ; 44(1): 16-20, 2019.
Article in English | MEDLINE | ID: mdl-30983766

ABSTRACT

PURPOSE: PerFRACTION™ is a three-dimensional (3D) in vivo electronic portal imaging device-based dosimetry software. To validate the software, three phantoms with different inserts (2D array, ionization chamber, and inhomogeneity materials) were constructed to evaluate point dose and fluence map. MATERIALS AND METHODS: Phantoms underwent independent computed tomography simulation for planning and received repetitive fractions of volumetric modulated arc therapy, simulating prostate treatment. Fluence and absolute point dose measurements, PerFRACTION™ reconstructed doses, and the dose predictions of the planning system were compared. RESULTS: There was concordance between ionization chamber and PerFRACTION™ 3D absolute point dose measurements. Close agreement was also obtained between X- and Y-axis dose profiles with PerFRACTION™ calculated doses, MapCHECK measured doses, and planning system predicted doses. Setup shifts significantly influenced 2D gamma passing rates in PerFRACTION™ software. CONCLUSIONS: PerFRACTION™ appears reliable and valid under experimental conditions in air and with phantoms.

2.
J Appl Clin Med Phys ; 19(5): 651-658, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30112817

ABSTRACT

A commercial semi-empirical volumetric dose verification system (PerFraction [PF], Sun Nuclear Corp.) extracts multi-leaf collimator positions from the electronic portal imaging device movies collected during a pre-treatment run, while the rest of the delivered control point information is harvested from the accelerator log files. This combination is used to reconstruct dose on a patient CT dataset with a fast superposition/convolution algorithm. The method was validated for single-isocenter multi-target SRS VMAT treatments against absolute radiochromic film measurements in a cylindrical phantom. The targets ranged in size from 0.8 to 3.6 cm and in number from 3 to 10 per plan. A total of 17 films rotated at different angles around the cylinder axis were analyzed. Each of 27 total targets was intercepted by at least one film, and 2-4 different films were analyzed per plan. Film dose was always scaled to the ion chamber measurement in a high-dose, low-gradient area deliberately created at the isocenter. The planar dose agreement between PF and film using 3%(Global dose-difference normalization)/1 mm gamma analysis was on average 99.2 ± 1.1%. The point dose difference in the low-gradient area in the middle of every target was below 3%, while PF-reconstructed and film dose centroids for individual targets showed submillimeter agreement when measured on a well aligned accelerator. Volumetrically, all voxels in all plans agreed between PF and the primary treatment planning system at the 3%/1 mm level. With proper understanding of its advantages and shortcomings, the tool can be applied to patient-specific QA in routine radiosurgical clinical practice.


Subject(s)
Phantoms, Imaging , Humans , Radiometry , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
3.
J Appl Clin Med Phys ; 18(3): 73-82, 2017 May.
Article in English | MEDLINE | ID: mdl-28371377

ABSTRACT

A superposition/convolution GPU-accelerated dose computation algorithm (the Calculator) has been recently incorporated into commercial software. The algorithm requires validation prior to clinical use. Three photon energies were examined: conventional 6 MV and 15 MV, and 10 MV flattening filter free (10 MVFFF). For a set of IMRT and VMAT plans based on four of the five AAPM Practice Guideline 5a downloadable datasets, ion chamber (IC) measurements were performed on the water-equivalent phantoms. The average difference between the Calculator and IC was -0.3 ± 0.8% (1SD). The same plans were projected on a phantom containing a biplanar diode array. We used the forthcoming criteria for routine gamma analysis, 3% dose-error (global (G) normalization, 2 mm distance to agreement, and 10% low dose cutoff). The γ (3%G/2 mm) average passing rate was 98.9 ± 2.1%. Measurement-guided three-dimensional dose reconstruction on the patient CT dataset (excluding the Lung) resulted in a similar average agreement rate with the Calculator: 98.2 ± 2.0%. The mean γ (3%G/2 mm) passing rate comparing the Calculator to the TPS (again excluding the Lung) was 99.0 ± 1.0%. Because of the significant inhomogeneity, the Lung case was investigated separately. The calculator has an alternate heterogeneity correction mode that can change the results in the thorax for higher-energy beams (15 MV). As this correction is nonphysical and was optimized for simple slab geometries, its application leads to mixed results when compared to the TPS and independent Monte Carlo calculations, depending on the CT dataset and the plan. The Calculator vs. TPS 15 MV Guideline 5a IMRT and VMAT plans demonstrate 96.3% and 93.4% γ (3%G/2 mm) passing rates respectively. For the lower energies, which should be predominantly used in the thoracic region, the passing rates for the same plans and criteria range from 98.6 to 100%. Overall, the Calculator accuracy is sufficient for the intended use.


Subject(s)
Algorithms , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Monte Carlo Method , Phantoms, Imaging
4.
Technol Cancer Res Treat ; 5(5): 465-79, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16981789

ABSTRACT

Image-guided IMRT is a revolutionary concept whose clinical implementation is rapidly evolving. Methods of executing beam intensity modulation have included individually designed compensators, static multi-leaf collimators (MLC), dynamic MLC, and sequential (serial) tomotherapy. We have developed helical tomotherapy as an innovative solution to overcome some of the limitations of other IMRT systems. The unique physical design of helical tomotherapy allows the realization of the concepts of adaptive radiotherapy and conformal avoidance. In principle, these advances should improve normal tissue sparing and permit dose reconstruction and verification, thereby allowing significant biologically effective dose escalation. Recent radiobiological findings can be translated into altered fractionation schemes that aim to improve the local control and long-term survival. This strategy is being tested at the University of Wisconsin using helical tomotherapy with its highly precise delivery and verification system along with meticulous and practical forms of immobilization. Innovative techniques such optical guidance, respiratory gating, and ultrasound assessments are being designed and tailored for helical tomotherapy use. The intrinsic capability of helical tomotherapy for megavoltage CT (MVCT) imaging for IMRT image-guidance is being optimized. The unique features of helical tomotherapy might allow implementation of image-guided IMRT that was previously impossible or impractical. Here we review the technological, physical, and radiobiological rationale for the ongoing and upcoming clinical trials that will use image-guided IMRT in the form of helical tomotherapy; and we describe our plans for testing our hypotheses in a rigorous prospective fashion.


Subject(s)
Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Tomography, Spiral Computed
5.
Med Phys ; 32(10): 3214-24, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16279075

ABSTRACT

Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy, (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (+/-10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (+/-7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In addition, conformal radiation to the bone marrow appears feasible in an external radiation treatment using image-guided helical tomotherapy.


Subject(s)
Bone Marrow Neoplasms/radiotherapy , Bone Marrow/radiation effects , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Whole-Body Counting/methods , Whole-Body Irradiation/methods , Feasibility Studies , Humans , Phantoms, Imaging , Radiotherapy Dosage
6.
Int J Radiat Oncol Biol Phys ; 60(5): 1639-44, 2004 Dec 01.
Article in English | MEDLINE | ID: mdl-15590196

ABSTRACT

PURPOSE: To evaluate the utility of relatively low-dose megavoltage computed tomography (MVCT) images from a clinical helical tomotherapy system for setup verification purposes. METHODS AND MATERIALS: Cross-sectional kilovolt computed tomography (kVCT) images were obtained for treatment planning purposes on a diagnostic third-generation CT scanner, followed by MVCT images from a helical tomotherapy system in 8 pet dogs with spontaneously occurring tumors. The kVCT and MVCT images were aligned for setup verification purposes, allowing repositioning before treatment delivery. RESULTS: Tumors are readily visualized on the MVCT images. At a dose of 2-3 cGy, the MVCT images are of sufficient quality for verification of treatment setup, but soft-tissue contrast is inferior to that with conventional kVCT. The MV and kVCT images were successfully aligned. When necessary, patients undergoing helical tomotherapy were repositioned before treatment. CONCLUSIONS: Megavoltage CT image quality is sufficient for tumor identification and three-dimensional setup verification in dogs with spontaneous tumors. The MVCT images can be aligned with the planning kVCT to ensure proper patient registration before treatment. Image alignment was successful in these canine patients, despite no skin markings defining patient positioning between the two scans. MVCT images facilitate setup verification, and their tomographic nature offers improvements over conventional portal imaging.


Subject(s)
Bone Neoplasms/radiotherapy , Nasopharyngeal Neoplasms/radiotherapy , Osteosarcoma/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Tomography, Spiral Computed/methods , Animals , Bone Neoplasms/veterinary , Calibration , Dog Diseases/radiotherapy , Dogs , Nasopharyngeal Neoplasms/veterinary , Osteosarcoma/veterinary , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Conformal/instrumentation , Tomography, Spiral Computed/instrumentation
7.
Technol Cancer Res Treat ; 3(6): 639-46, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15560722

ABSTRACT

A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during CT. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. "Hot spots" (> or =150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.


Subject(s)
Breast Neoplasms/radiotherapy , Brachytherapy , Breast Neoplasms/pathology , Humans , Therapy, Computer-Assisted
8.
Med Phys ; 31(2): 396-404, 2004 Feb.
Article in English | MEDLINE | ID: mdl-15000626

ABSTRACT

Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery.


Subject(s)
Radiotherapy, Conformal/methods , Tomography/methods , Electrons , Humans , Monte Carlo Method , Particle Accelerators , Photons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Sensitivity and Specificity , Software
9.
Int J Radiat Oncol Biol Phys ; 56(1): 89-105, 2003 May 01.
Article in English | MEDLINE | ID: mdl-12694827

ABSTRACT

PURPOSE: To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS: Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS: Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS: Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.


Subject(s)
Radiotherapy, Computer-Assisted , Radiotherapy, Conformal/methods , Radiotherapy, High-Energy/methods , Tomography, X-Ray Computed , Animals , Dogs , Equipment Design , Humans , Motion , Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Particle Accelerators/instrumentation , Radiation Injuries/prevention & control , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed/instrumentation , Ultrasonography
10.
Med Phys ; 30(12): 3097-106, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14713076

ABSTRACT

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.


Subject(s)
Equipment Failure Analysis/methods , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/methods , Tomography, Spiral Computed/methods , Equipment Failure Analysis/instrumentation , Film Dosimetry/methods , Radiometry/standards , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/standards , Reproducibility of Results , Sensitivity and Specificity , Tomography, Spiral Computed/instrumentation