Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Vascular ; 29(4): 624-629, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32998667

ABSTRACT

OBJECTIVES: To investigate the incidence and clinical significance of caval pseudoaneurysm and extravasation post-complex inferior vena cava filter retrieval. METHODS: A total of 83 patients (70% female, average age 56) underwent complex inferior vena cava filter retrieval between January 2015 and December 2019 utilizing either rigid endobronchial forceps (n = 69, 83%) and/or excimer laser (n = 20, 24%). Procedural variables were recorded. The incidence and size of caval pseudoaneurysms and extravasation along with treatment type and clinical outcomes were analyzed. RESULTS: Technical success in all cases was 96% (n = 80). Average fluoroscopy time was 23 min (median: 20.2, range: 0.9-129.5). Average filter dwell time was 85 months (range: 2-316 months). Caval pseudoaneurysm was detected on post-retrieval venography in 10 patients (12%) and frank extravasation occurred in 1 case (1%). Average pseudoaneurysm length and width was 20.4 mm (range: 5-45 mm) and 12.9 mm (range: 4-24 mm), respectively. Pseudoaneurysms occurred most frequently during the removal of Optease (n = 5) and Celect (n = 2) filters. The pseudoaneurysms completely resolved with prolonged (>5 min) balloon angioplasty in all but one instance where a small portion of the pseudoaneurysm persisted. This patient was admitted and observed overnight before being discharged without complication. The solitary case of significant extravasation was effectively managed with immediate stent placement and the patient remained hemodynamically stable. CONCLUSIONS: Radiographically detectable caval pseudoaneurysm and extravasation is not uncommon in complex inferior vena cava filter retrieval and, despite being considered a major complication by Society of Interventional Radiology guidelines, can often be managed without stenting or other invasive treatment.


Subject(s)
Aneurysm, False/etiology , Device Removal/adverse effects , Prosthesis Implantation/instrumentation , Vascular System Injuries/etiology , Vena Cava Filters , Vena Cava, Inferior/surgery , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Angioplasty, Balloon/instrumentation , Female , Humans , Middle Aged , Retrospective Studies , Stents , Time Factors , Treatment Outcome , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/therapy , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/injuries
2.
J Vasc Interv Radiol ; 29(2): 170-175, 2018 02.
Article in English | MEDLINE | ID: mdl-29203395

ABSTRACT

PURPOSE: To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. MATERIALS AND METHODS: Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. RESULTS: Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P < .01). Fluoroscopy time was similar for IR and OR filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). CONCLUSIONS: Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR.


Subject(s)
Device Removal/economics , Radiography, Interventional/economics , Vena Cava Filters/economics , Vena Cava, Inferior , Aged , Female , Fluoroscopy , Humans , Middle Aged , Retrospective Studies , Risk Factors , Tertiary Care Centers , Treatment Outcome
3.
J Vasc Interv Radiol ; 27(9): 1298-1304, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27499157

ABSTRACT

PURPOSE: To compare outcomes of conventional transarterial chemoembolization with drug-eluting bead (DEB) chemoembolization for treatment of neuroendocrine tumor liver metastases. MATERIALS AND METHODS: This single-center, retrospective study evaluated 177 transarterial chemoembolization treatments (78 conventional chemoembolization treatments using ethiodized oil-based cisplatin, mitomycin C, and doxorubicin and 99 DEB chemoembolization treatments using doxorubicin-loaded 100-300 µm DEBs) from 2012 to 2015. Hepatic disease distribution was 93% bilobar for both groups with largest lesion size 5.0 cm ± 2.7. No difference was noted in regard to lesion size or distribution, carcinoid syndrome, or pancreastatin production. Clinical outcomes including complications; liver function tests (LFTs); and radiologic (modified Response Evaluation Criteria in Solid Tumors), biochemical (pancreastatin levels), and symptomatic responses were evaluated at 1-month follow-up. RESULTS: Higher symptomatic response (complete and partial) was identified with conventional transarterial chemoembolization compared with DEB chemoembolization (47% vs 30%; P < .05). Patients receiving DEB transarterial chemoembolization experienced lower elevation of LFTs (aspartate aminotransferase, 39 U/L vs 122 U/L; alanine aminotransferase, 20 U/L vs 93 U/L; bilirubin, 0.001 mg/dL vs 0.123 mg/dL; P < .05) and less postembolization syndrome (50% vs 67%; P < .05). Patients undergoing first-time DEB transarterial chemoembolization had lower periprocedural octreotide maximum rate requirements (58 µg/h vs 66 µg/h; P < .05). No difference was observed in biochemical (P = .60) or radiologic (P < .20) responses. CONCLUSIONS: Conventional transarterial chemoembolization yields better symptomatic response and may be preferred for patients experiencing carcinoid symptoms. DEB transarterial chemoembolization, with lower LFT elevations and postembolization syndrome incidence, may be preferred for patients with poor liver function.


Subject(s)
Antineoplastic Agents/administration & dosage , Carcinoma, Neuroendocrine/secondary , Carcinoma, Neuroendocrine/therapy , Chemoembolization, Therapeutic/methods , Drug Carriers , Ethiodized Oil/administration & dosage , Liver Neoplasms/secondary , Liver Neoplasms/therapy , Aged , Antineoplastic Agents/adverse effects , Chemoembolization, Therapeutic/adverse effects , Cisplatin/administration & dosage , Doxorubicin/administration & dosage , Ethiodized Oil/adverse effects , Female , Humans , Liver Function Tests , Male , Middle Aged , Mitomycin/administration & dosage , Ohio , Patient Selection , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...