Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Assoc Physicians India ; 71(7): 11-12, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37449686

ABSTRACT

Intracranial pressure (ICP) needs to be monitored in neurocritical patients. There is a need for portable bedside optic nerve ultrasound (ONUS) for early diagnosis to initiate the measures to reduce ICP Objective: To find the utility of bedside ONUS to diagnose raised ICP in neurocritical care. Materials and methods: After approval from the ethical committee, a prospective observational study was conducted. Optic nerve sheath diameter (ONSD) was measured in two groups: control group patients with neurological symptoms but computed tomography (CT)/magnetic resonance imaging (MRI) not suggestive of raised ICP, and second was study group patients with neurological symptoms and CT/MRI suggestive of elevated ICP Result: In patients with normal ICP, the mean ONSD in females was 4.47mm, and in males was 4.66mm. In patients with raised ICP, the mean ONSD in females was 6.45 ± 0.78 mm, and in males was 6.33 ± 0.70 mm. Regarding the correlation between Glasgow coma scale (GCS) and mean ONSD parameters, the coefficient of correlation (R) is 0.14; thus, there is a weak negative correlation. In our study, no difference was observed in raised mean ONSD in patients with different diagnoses. At a cut-off value of >4.8 mm, the sensitivity and specificity are 100% to diagnose raised ICP. Conclusion: Optic nerve sheath diameter (ONSD) is a reliable, rapid bedside screening tool in the Emergency Department/Critical Care/Operation Theatre to diagnose raised ICP. In order to keep a record of trends in ICP, we need to measure ONSD frequently. There was no correlation between GCS and ONSD measurement.


Subject(s)
Intracranial Hypertension , Intracranial Pressure , Male , Female , Humans , Intracranial Pressure/physiology , Ultrasonography/methods , Intracranial Hypertension/diagnostic imaging , Prospective Studies , Optic Nerve/diagnostic imaging
2.
Anesth Essays Res ; 10(1): 17-22, 2016.
Article in English | MEDLINE | ID: mdl-26957684

ABSTRACT

BACKGROUND: Pressor response is a part of stress response caused by reflex sympathetic discharge due to direct laryngoscopy and tracheal intubation resulting in tachycardia, hypertension and arrhythmias. Both clonidine, and gabapentin administered orally can effectively blunt this detrimental hemodynamic response. AIM: To study the effect of oral clonidine to blunt the pressor response to direct laryngoscopy and to compare it with oral gabapentin. To observe for postoperative sedation and side effects if any. SETTINGS AND DESIGN: Sixty patients of American Society of Anaesthesiologist Grade I and II scheduled for surgery under general anesthesia were considered in this prospective randomized double-blind study. They were randomly allocated into two groups of 30 each using computerized randomization. MATERIALS AND METHODS: Group A was given oral clonidine 5 µg/kg and Group B was given oral gabapentin 800 mg. Both the drugs were given 90 min prior to surgery. Heart rate (HR) and blood pressure were monitored at baseline, 0, 1, 3, 5, 10, 15, and 30(th) min of laryngoscopy. Sedation was monitored by Ramsay Sedation Scale score and side effects were noted. RESULTS: HR decreased in both groups at 0 and 1 min, increased at 3(rd) min and gradually decreased by 30(th) min. Statistically, significant difference was found between two groups at 1, 3, 5, 10, and 15(th) min (P < 0.05). Though there was no significant difference in systolic blood pressure, diastolic blood pressure and mean arterial pressure between the two groups, there was no rise in these parameters. Gabapentin produced more sedation than clonidine postoperatively, and few side effects were noted. CONCLUSION: Both oral clonidine and gabapentin are effective in obtunding pressor response to direct laryngoscopy, clonidine being better in terms of controlling HR. Gabapentin produces more postoperative sedation than clonidine.

SELECTION OF CITATIONS
SEARCH DETAIL
...