Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
Iowa Orthop J ; 43(1): 177-183, 2023.
Article in English | MEDLINE | ID: mdl-37383847

ABSTRACT

Treatment of distal femur fractures have reported high fracture healing complications in several studies. The development of far cortical locking (FCL) technology results in improved fracture healing outcomes. There are biomechanical and animal studies demonstrating that the locked plating incorporating FCL screws provides a more flexible form of fixation compared to traditional locking plates (LP). Clinical studies have shown that the commercially available Zimmer Motionloc system with FCL screws provide good results in distal femur fractures and periporsthetic distal femur fractures. FCL constructs may help resolve fracture healing problems in the future. However, there is not enough available clinical evidence to conclusively indicate whether clinical healing rates are improved with FCL screw constructs compared to traditional LP's. Therefore, further prospective study designs are needed to compare FCL to LP constructs and to investigate the role of interfragmentary motion on callus formation. Level of Evidence: V.


Subject(s)
Femoral Fractures, Distal , Fracture Fixation, Internal , Animals , Prospective Studies , Bone Screws , Fracture Healing
2.
Iowa Orthop J ; 43(1): 191-194, 2023.
Article in English | MEDLINE | ID: mdl-37383865

ABSTRACT

Background: Despite the increased frequency of cephalomedullary fixation for unstable intertrochanteric hip fractures, failure with screw cut-out and varus collapse remains a significant failure mode. Proper positioning of implants into the femoral neck and head directly influences the stability of fracture fixation. Visualization of the femoral neck and head can be challenging and failure to do so may lead to poor results; Obstacles include patient positioning, body habitus, and implant application tools. We present the "Winquist View," an oblique fluoroscopic projection that shows the femoral neck in profile, aligns the implant and cephalic component, and assists in implant placement. Methods: With the patient in the lateral position, the legs are scissored when possible. Following standard reduction techniques, the Winquist view is used to check reduction prior to surgical draping. Intraoperatively, we rely on a perfect image to place implants in the ideal portion of the femoral neck, with a trajectory that achieves the center-center or center-low position of the femoral neck. This is achieved by incorporating the anterior-posterior, lateral, and Winquist view. Results: We present 3 patients who underwent fixation with a cephalomedullary nail for intertrochanteric hip fractures. The Winquist view facilitated excellent visualization and positioning in all cases. All postoperative courses were uneventful, without failures or complications. Conclusion: While standard intraoperative imaging may be adequate in many cases, the Winquist view facilitates optimal implant positioning and fracture reduction. With lateral imaging, implant insertion guides may obscure visualization of the femoral neck during which Winquist view is the most helpful. Level of Evidence: V.


Subject(s)
Hip Fractures , Plastic Surgery Procedures , Humans , Femur Neck/diagnostic imaging , Femur Neck/surgery , Bone Screws , Fluoroscopy
3.
Clin Exp Med ; 23(7): 3509-3516, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37341931

ABSTRACT

BACKGROUND AND OBJECTIVE: NSAIDs inhibit cyclooxygenase, but their role in aging and other diseases is not well understood. Our group previously showed the potential benefit of NSAIDs in decreasing the risk of delirium and mortality. Concurrently, epigenetics signals have also been associated with delirium. Therefore, we sought to find differentially methylated genes and biological pathways related to exposure with NSAIDs by comparing the genome-wide DNA methylation profiles of patients with and without a history of NSAIDs use. METHODS: Whole blood samples were collected from 171 patients at the University of Iowa Hospital and Clinics from November 2017 to March 2020. History of NSAIDs use was assessed through a word-search function in the subjects' electronic medical records. DNA was extracted from the blood samples, processed with bisulfite conversion, and analyzed using Illumina's EPIC array. The analysis of top differentially methylated CpG sites and subsequent enrichment analysis were conducted using an established pipeline using R statistical software. RESULTS: Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genome (KEGG) showed several biological pathways relevant to NSAIDs' function. The identified GO terms included "arachidonic acid metabolic process," while KEGG results included "linoleic acid metabolism," "cellular senescence," and "circadian rhythm." Nonetheless, none of the top GO and KEGG pathways and the top differentially methylated CpG sites reached statistical significance. CONCLUSION: Our results suggest a potential role of epigenetics in the mechanisms of the action of NSAIDs. However, the results should be viewed with caution as exploratory and hypothesis-generating given the lack of statistically significant findings.


Subject(s)
DNA Methylation , Delirium , Humans , Epigenesis, Genetic , Aging , CpG Islands , Delirium/genetics
4.
J Psychosom Res ; 168: 111212, 2023 05.
Article in English | MEDLINE | ID: mdl-36963165

ABSTRACT

OBJECTIVE: To investigate the relationship between history of anti-inflammatory medication use and delirium risk, as well as long-term mortality. METHODS: In this retrospective cohort study, subjects recruited between January 2016 and March 2020 were analyzed. Information about anti-inflammatory medication use history including aspirin, NSAIDs, glucosamine, and other anti-inflammatory drugs, was collected. Logistic regression analysis investigated the relationship between anti-inflammatory medications and delirium. Log-rank analysis and cox proportional hazards model investigated the relationship between anti-inflammatory medications and one-year mortality. RESULTS: The data from 1274 subjects were analyzed. The prevalence of delirium was significantly lower in subjects with NSAIDs usage (23.0%) than in those without NSAIDs usage (35.0%) (p < 0.001). Logistic regression analysis controlling for age, sex, dementia status, and hospitalization department showed that the risk of delirium tended to be reduced by a history of NSAIDs use (OR, 0.76 [95% CI, 0.55 to 1.03]). The one-year mortality in the subjects with NSAIDs (survival rate, 0.879 [95% CI, 0.845 to 0.906]) was significantly lower than in the subjects without NSAIDs (survival rate, 0.776 [95% CI, 0.746 to 0.803]) (p < 0.001). A history of NSAIDs use associated with the decreased risk of one-year mortality even after adjustment for age, sex, Charlson Comorbidity Index, delirium status, and hospitalization department (HR, 0.70 [95% CI, 0.51 to 0.96]). CONCLUSION: This study suggested that NSAIDs usage was associated with decreased delirium prevalence and lower one-year mortality. The potential benefit of NSAIDs on delirium risk and mortality were shown.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal , Delirium , Humans , Retrospective Studies , Anti-Inflammatory Agents, Non-Steroidal/adverse effects , Aspirin/therapeutic use , Proportional Hazards Models , Delirium/epidemiology , Delirium/complications
5.
OTA Int ; 5(3): e200, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36425090

ABSTRACT

Background: The classification of fractures is necessary to ensure a reliable means of communication for clinical interaction, education and research. The Neer classification is the most commonly used classification for proximal humerus fractures. In 2018 the Orthopedic Trauma Association (OTA) and the AO Foundation provided an update to the OTA/AO Fracture Classification Scheme addressing many of the concerns about the previous versions of the classification. The objective of the present study was to evaluate the rater reliability of the 2 classifications and if the classifications subjectively better characterized the fracture patterns. Methods: X-rays and CT scans of 24 proximal humerus fractures were given to 7 independent raters for classification according to the Neer and 2018 OTA/AO classification. Both full-forms and short-forms of the classifications were tested. The Fleiss Kappa statistic was used to assess inter-rater agreement and intra-rater consistency for the 2 classifications. For each case the raters subjectively commented on how well each classification was able to characterize the fracture pattern. Results: All raters graded the 2018 OTA/AO classification as good as or better than the Neer classification for an adequate description of the fracture patterns. The short-form 2018 OTA/AO classification had the most 4 rater and 5 rater agreement cases and the second most 6 rater agreement cases. The short-form Neer classification had the second most 4 rater and 5 rater agreement cases and the most 6 rater agreement cases. The full 2018 OTA/AO had the least 4, 5, or 6 rater agreement cases of all the classification systems. Inter-rater agreement was fair for the full and short form of both the Neer and 2018 OTA/AO classification. The full and short Neer classifications together with the short 2018 OTA/AO classification had moderate intra-rater consistency, while the full 2018 OTA/AO classification only had slight intra-rater consistency. Conclusions: The 2018 OTA/AO classification is equivalent in its short-form to the Neer classification in inter-rater reliability and intra-rater consistency; and is superior in its full form for characterizing specific fracture types. The low inter-rater reliability of the full 2018 OTA/AO classification is a concern that may need to be addressed in the future.

6.
J Bone Joint Surg Am ; 104(9): 759-766, 2022 05 04.
Article in English | MEDLINE | ID: mdl-35286282

ABSTRACT

BACKGROUND: Postoperative complications and substantial loss of physical function are common after musculoskeletal trauma. We conducted a prospective randomized controlled trial to assess the impact of conditionally essential amino acid (CEAA) supplementation on complications and skeletal muscle mass in adults after operative fixation of acute fractures. METHODS: Adults who sustained pelvic and extremity fractures that were indicated for operative fixation at a level-I trauma center were enrolled. The subjects were stratified based on injury characteristics (open fractures and/or polytrauma, fragility fractures, isolated injuries) and randomized to standard nutrition (control group) or oral CEAA supplementation twice daily for 2 weeks. Body composition (fat-free mass [FFM]) was measured at baseline and at 6 and 12 weeks postoperatively. Complications were prospectively collected. An intention-to-treat analysis was performed. The relative risk (RR) of complications for the control group relative to the CEAA group was determined, and linear mixed-effects models were used to model the relationship between CEAA supplementation and changes in FFM. RESULTS: Four hundred subjects (control group: 200; CEAA group: 200) were enrolled. The CEAA group had significantly lower overall complications than the control group (30.5% vs. 43.8%; adjusted RR = 0.71; 95% confidence interval [CI] = 0.55 to 0.92; p = 0.008). The FFM decreased significantly at 6 weeks in the control subjects (-0.9 kg, p = 0.0205), whereas the FFM was maintained at 6 weeks in the CEAA subjects (-0.33 kg, p = 0.3606). This difference in FFM was not seen at subsequent time points. CONCLUSIONS: Our results indicate that CEAA supplementation has a protective effect against common complications and early skeletal muscle wasting after operative fixation of extremity and pelvic fractures. Given the potential benefits of this inexpensive, low-risk intervention, multicenter prospective studies in focused trauma populations are warranted. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Fracture Fixation , Fractures, Bone , Adult , Amino Acids, Essential , Dietary Supplements , Fracture Fixation/methods , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Humans , Muscles , Postoperative Complications/prevention & control , Prospective Studies
7.
J Surg Educ ; 79(1): 266-273, 2022.
Article in English | MEDLINE | ID: mdl-34509414

ABSTRACT

OBJECTIVE: This study examines the role of electronic learning platforms for medical knowledge acquisition in orthopedic surgery residency training. This study hypothesizes that all methods of medical knowledge acquisition will achieve similar levels of improvement in medical knowledge as measured by change in orthopedic in-training examination (OITE) percentile scores. Our secondary hypothesis is that residents will equally value all study resources for usefulness in acquisition of medical knowledge, preparation for the OITE, and preparation for surgical practice. DESIGN: 9 ACGME accredited orthopedic surgery programs participated with 95% survey completion rate. Survey ranked sources of medical knowledge acquisition and study habits for OITE preparation. Survey results were compared to OITE percentile rank scores. PARTICIPANTS: 386 orthopedic surgery residents SETTING: 9 ACGME accredited orthopaedic surgery residency programs RESULTS: 82% of participants were utilizing online learning resources (Orthobullets, ResStudy, or JBJS Clinical Classroom) as primary sources of learning. All primary resources showed a primary positive change in OITE score from 2018 to 2019. No specific primary source improved performance more than any other sources. JBJS clinical classroom rated highest for improved medical knowledge and becoming a better surgeon while journal reading was rated highest for OITE preparation. Orthopedic surgery residents' expectation for OITE performance on the 2019 examination was a statistically significant predictor of their change (decrease, stay the same, improve) in OITE percentile scores (p<0.001). CONCLUSIONS: Our results showed that no specific preferred study source outperformed other sources. Significantly 82% of residents listed an online learning platform as their primary source which is a significant shift over the last decade. Further investigation into effectiveness of methodologies for electronic learning platforms in medical knowledge acquisition and in improving surgical competency is warranted.


Subject(s)
Internship and Residency , Orthopedics , Clinical Competence , Education, Medical, Graduate/methods , Educational Measurement/methods , Humans , Orthopedics/education
8.
J Am Acad Orthop Surg ; 30(4): 161-167, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-34910714

ABSTRACT

INTRODUCTION: Arthroscopy simulation is increasingly used in orthopaedic residency training. The implementation of a curriculum to accommodate these new training tools is a point of interest. We assessed the use of a high-fidelity arthroscopy simulator in a strictly voluntary curriculum to gauge resident interest and educational return. METHODS: Fifty-eight months of simulator use data were collected from a single institution to analyze trends in resident use. Comparable data from two additional residency programs were analyzed as well, for comparison. Orthopaedic residents were surveyed to gauge interest in continued simulation training. RESULTS: Average annual simulator use at the study institution was 27.7 hours (standard deviation = 26.8 hours). Orthopaedic residents spent an average of 1.7 hours practicing on the simulation trainer during the observation period. A total of 21% of residents met or exceeded a minimum of 3 hours of simulation time required for skill improvement defined by literature. Most (86%) of the residents agreed that the simulator in use should become a mandated component of a junior resident training. CONCLUSION: Although surgical simulation has a role in orthopaedic training, voluntary simulator use is sporadic, resulting in many residents not receiving the full educational benefits of such training. Implementation of a mandated simulation training curriculum is desired by residents and could improve the educational return of surgical simulators in residency training.


Subject(s)
Internship and Residency , Orthopedics , Simulation Training , Clinical Competence , Computer Simulation , Curriculum , Humans , Laboratories , Orthopedics/education
9.
Iowa Orthop J ; 42(2): 8-21, 2022.
Article in English | MEDLINE | ID: mdl-36601231

ABSTRACT

Background: Mentorship and research have been shown to be important decision factors influencing medical students to pursue a particular specialty. The cost of applying to orthopedic surgery residency is at an all-time high. The purpose of this study is to identify the factors which increase the likelihood of medical students matching into orthopedic surgery, identify the timing and strength of impact these factors have on medical students' career choices, determine how many students have chosen orthopedic surgery prior to beginning medical school, and compare the financial impact of applying to orthopedics. Methods: 608 medical students were surveyed 5 times during medical school (at the start of M1, M2, M3, M4 year and after the match process) to identify ongoing factors that influence their career choice and ultimately matching in orthopedic surgery. Unadjusted odds ratios and cost analysis were used to determine the factors influencing specialty choice. Level of evidence: III. Results: Students who matched into orthopedic surgery were more likely to be mentored by an orthopedic surgeon at all 5 survey points (M1 OR=30.93, M2 OR=12.38, M3 OR=17.96, M4 OR=65.2, Match OR=215.45) and involved in orthopedic surgery research at the last 4 survey points (M2 OR=20.05, M3 OR=14.00, M4 OR=12.00, Match OR=1566.60) compared to students who did not match into orthopedic surgery. 10 out of 19 students (52.6%) who matched into orthopedic surgery listed the specialty as their preference in the M1 survey. Students who matched into orthopedic surgery spent $8,838.80 on applications and interviews, while students applied to and matched into other specialties spent an average of $6,173.4 (p-value=0.007). Conclusion: Many students have a predetermined plan to enter orthopedic surgery prior to medical school. Mentorship and research are important factors increasing students' interest in orthopedic surgery and ultimately leading to a successful match process. Going through the orthopedic surgery match process is significantly more expensive than other specialties. Level of Evidence: IV.


Subject(s)
Internship and Residency , Orthopedic Procedures , Orthopedics , Students, Medical , Humans , Orthopedics/education , Education, Medical, Graduate , Surveys and Questionnaires
10.
Bone Jt Open ; 2(10): 796-805, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34587782

ABSTRACT

AIMS: The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing. METHODS: A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point. RESULTS: The mean mRUST score of ten at 24 weeks revealed a 91.9% sensitivity, 100% specificity, and 92.6% accuracy of predicting ultimate fracture healing. A cut-off point of 13 points revealed 41.9% sensitivity, 100% specificity, and 46.9% accuracy at the same time point. CONCLUSION: The mRUST score of ten points at 24 weeks can be used as a viable screening method with the highest sensitivity, specificity, and accuracy for healing of metadiaphyseal femur fractures. However, the cut-off point of 13 increases the specificity to 100%, but decreases sensitivity. Furthermore, the mRUST score should not be used at six weeks, as results show an inability to accurately predict eventual fracture healing at this time point. Cite this article: Bone Jt Open 2021;2(10):796-805.

11.
Sci Rep ; 11(1): 14211, 2021 07 09.
Article in English | MEDLINE | ID: mdl-34244577

ABSTRACT

We have previously developed a bispectral electroencephalography (BSEEG) device, which was shown to be effective in detecting delirium and predicting patient outcomes. In this study we aimed to apply the BSEEG approach for a sepsis. This was a retrospective cohort study conducted at a single center. Sepsis-positive cases were identified based on retrospective chart review. EEG raw data and calculated BSEEG scores were obtained in the previous studies. The relationship between BSEEG scores and sepsis was analyzed, as well as the relationship among sepsis, BSEEG score, and mortality. Data were analyzed from 628 patients. The BSEEG score from the first encounter (1st BSEEG) showed a significant difference between patients with and without sepsis (p = 0.0062), although AUC was very small indicating that it is not suitable for detection purpose. Sepsis patients with high BSEEG scores showed the highest mortality, and non-sepsis patients with low BSEEG scores showed the lowest mortality. Mortality of non-sepsis patients with high BSEEG scores was as bad as that of sepsis patients with low BSEEG scores. Even adjusting for age, gender, comorbidity, and sepsis status, BSEEG remained a significant predictor of mortality (p = 0.008). These data are demonstrating its usefulness as a potential tool for identification of patients at high risk and management of sepsis.


Subject(s)
Delirium/mortality , Delirium/pathology , Electroencephalography/methods , Sepsis/mortality , Sepsis/pathology , Aged , Female , Humans , Intensive Care Units , Male , Middle Aged , Retrospective Studies
12.
Clin Orthop Relat Res ; 479(6): 1386-1394, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33399401

ABSTRACT

BACKGROUND: To advance orthopaedic surgical skills training and assessment, more rigorous and objective performance measures are needed. In hip fracture repair, the tip-apex distance is a commonly used summative performance metric with clear clinical relevance, but it does not capture the skill exercised during the process of achieving the final implant position. This study introduces and evaluates a novel Image-based Decision Error Analysis (IDEA) score that better captures performance during fluoroscopically-assisted wire navigation. QUESTIONS/PURPOSES: (1) Can wire navigation skill be objectively measured from a sequence of fluoroscopic images? (2) Are skill behaviors observed in a simulated environment also exhibited in the operating room? Additionally, we sought to define an objective skill metric that demonstrates improvement associated with accumulated surgical experience. METHODS: Performance was evaluated both on a hip fracture wire navigation simulator and in the operating room during actual fracture surgery. After examining fluoroscopic image sequences from 176 consecutive simulator trials (performed by 58 first-year orthopaedic residents) and 21 consecutive surgical procedures (performed by 19 different orthopaedic residents and one attending orthopaedic surgeon), three main categories of erroneous skill behavior were identified: off-target wire adjustments, out-of-plane wire adjustments, and off-target drilling. Skill behaviors were measured by comparing wire adjustments made between consecutive images against the goal of targeting the apex of the femoral head as part of our new IDEA scoring methodology. Decision error metrics (frequency, magnitude) were correlated with other measures (image count and tip-apex distance) to characterize factors related to surgical performance on both the simulator and in the operating room. An IDEA composite score integrating decision errors (off-target wire adjustments, out-of-plane wire adjustments, and off-target drilling) and the final tip-apex distance to produce a single metric of overall performance was created and compared with the number of hip wire navigation cases previously completed (such as surgeon experience levels). RESULTS: The IDEA methodology objectively analyzed 37,000 images from the simulator and 688 images from the operating room. The number of decision errors (7 ± 5 in the operating room and 4 ± 3 on the simulator) correlated with fluoroscopic image count (33 ± 14 in the operating room and 20 ± 11 on the simulator) in both the simulator and operating room environments (R2 = 0.76; p < 0.001 and R2 = 0.71; p < 0.001, respectively). Decision error counts did not correlate with the tip-apex distance (16 ± 4 mm in the operating room and 12 ± 5 mm on the simulator) for either the simulator or the operating room (R2 = 0.08; p = 0.15 and R2 = 0.03; p = 0.47, respectively), indicating that the tip-apex distance is independent of decision errors. The IDEA composite score correlated with surgical experience (R2 = 0.66; p < 0.001). CONCLUSION: The fluoroscopic images obtained in the course of placing a guide wire contain a rich amount of information related to surgical skill. This points the way to an objective measure of skill that also has potential as an educational tool for residents. Future studies should expand this analysis to the wide variety of procedures that rely on fluoroscopic images. CLINICAL RELEVANCE: This study has shown how resident skill development can be objectively assessed from fluoroscopic image sequences. The IDEA scoring provides a basis for evaluating the competence of a resident. The score can be used to assess skill at key timepoints throughout residency, such as when rotating onto/off of a new surgical service and before performing certain procedures in the operating room, or as a tool for debriefing/providing feedback after a procedure is completed.


Subject(s)
Clinical Competence/statistics & numerical data , Fluoroscopy , Hip Fractures/surgery , Medical Errors/statistics & numerical data , Orthopedic Procedures/education , Adult , Bone Wires , Decision Support Techniques , Female , Femur Head/surgery , Humans , Internship and Residency , Male , Middle Aged , Operating Rooms , Orthopedic Procedures/methods , Simulation Training
13.
Br J Psychiatry ; : 1-8, 2021 Aug 02.
Article in English | MEDLINE | ID: mdl-35049468

ABSTRACT

BACKGROUND: We have developed the bispectral electroencephalography (BSEEG) method for detection of delirium and prediction of poor outcomes. AIMS: To improve the BSEEG method by introducing a new EEG device. METHOD: In a prospective cohort study, EEG data were obtained and BSEEG scores were calculated. BSEEG scores were filtered on the basis of standard deviation (s.d.) values to exclude signals with high noise. Both non-filtered and s.d.-filtered BSEEG scores were analysed. BSEEG scores were compared with the results of three delirium screening scales: the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU), the Delirium Rating Scale-Revised-98 (DRS) and the Delirium Observation Screening Scale (DOSS). Additionally, the 365-day mortalities and the length of stay (LOS) in the hospital were analysed. RESULTS: We enrolled 279 elderly participants and obtained 620 BSEEG recordings; 142 participants were categorised as BSEEG-positive, reflecting slower EEG activity. BSEEG scores were higher in the CAM-ICU-positive group than in the CAM-ICU-negative group. There were significant correlations between BSEEG scores and scores on the DRS and the DOSS. The mortality rate of the BSEEG-positive group was significantly higher than that of the BSEEG-negative group. The LOS of the BSEEG-positive group was longer compared with that of the BSEEG-negative group. BSEEG scores after s.d. filtering showed stronger correlations with delirium screening scores and more significant prediction of mortality. CONCLUSIONS: We confirmed the usefulness of the BSEEG method for detection of delirium and of delirium severity, and prediction of patient outcomes with a new EEG device.

14.
Arthrosc Sports Med Rehabil ; 2(5): e569-e574, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33134996

ABSTRACT

PURPOSE: To determine trends in arthroscopic-assisted tibial plateau fracture fixation (AATPFF), to evaluate trends in the overall rate of tibial plateau fracture fixation, and to compare postoperative complications between AATPFF and traditional tibial plateau fixation. METHODS: A retrospective review of patients undergoing AATPFF and traditional tibial plateau fixation was conducted using the Humana Inc. administrative database from 2007 to 2016. A 1:1 propensity match was utilized to match patients in the 2 study groups based on age, sex, obesity, diabetes, hypertension, chronic obstructive pulmonary disease, depression or anxiety, and smoking history. Postoperative complications were grouped as minor medical complications, major medical complications, surgical complications, emergency department visits, and reoperation. Linear regression analysis was used to assess trends and Pearson's χ2 test was used to compare postoperative complications with statistical significance defined as P < .05. RESULTS: In total, 522 patients underwent AATPFF and 3920 patients underwent traditional tibial plateau fracture fixation. There was a 4-fold increase in the use of AATPFF over the study period (P = .0173). Similarly, there was an increase in the utilization of traditional tibial plateau fracture fixation, although to a lesser extent (1.33-fold). After propensity matching, the traditional fixation group demonstrated significantly higher rates of minor medical complications (8.2% vs 2.7%, P = .0002), major medical complications (9.9% vs 4.6%, P = .0018), surgical complications (13.2% vs 2.7%, P < .0001), and emergency department visits (21.4% vs 13.5%, P < .0001) within 90 days of surgery compared with the AATPFF group. There was no difference in reoperation rates within 90 days between the 2 groups (2.9% vs 3.6%, P = .85). CONCLUSIONS: The incidence of tibial plateau fracture fixation is increasing, however, use of AATPFF is increasing at a faster rate compared to traditional techniques. Furthermore, the addition of knee arthroscopy to fracture fixation does not increase the risk of complication, reoperation, or emergency department visit within 90 days. LEVEL OF EVIDENCE: III, retrospective matched cohort.

15.
Iowa Orthop J ; 40(1): 25-34, 2020.
Article in English | MEDLINE | ID: mdl-32742205

ABSTRACT

Background: Many orthopedic surgeries involve the challenging integration of fluoroscopic image interpretation with skillful tool manipulation to enable procedures to be performed through less invasive approaches. Simulation has proved beneficial for teaching and improving these skills for residents, but similar benefits have not yet been realized for practicing orthopedic surgeons. A vision is presented to elevate community orthopedic practice and improve patient safety by advancing the use of simulators for training and assessing surgical skills. Methods: Key elements of this vision that are established include 1) methods for the objective and rigorous assessment of the performance of practicing surgeons now exist, 2) simulators are sufficiently mature and sophisticated that practicing surgeons will use them, and 3) practicing surgeons can improve their performance with appropriate feedback and coaching. Results: Data presented indicate that surgical performance can be adequately and comparably measured using structured observations made by experts or non-expert crowds, with the crowdsourcing approach being more expedient and less expensive. Rigorous measures of the surgical result and intermediate objectives obtained semi-automatically from intra-operative fluoroscopic image sequences can distinguish performances of experts from novices. Experience suggests that practicing orthopedic surgeons are open to and can be constructively engaged by a family of mature simulators as a means to evaluate and improve their surgical skills. Conclusions: The results presented support our contention that new objective assessment measures are sufficient for evaluating the performance of working surgeons. The novel class of orthopedic surgical simulators available were tested and approved by practicing physicians. There exists a clear opportunity to combine purpose-designed simulator exercises with virtual coaching to help practicing physicians retain, retrain, and improve their technical skills. This will ultimately reduce cost, increase the quality of care, and decrease complication rates. Clinical Relevance: This vision articulates a means to boost the confidence of practitioners and ease their anxiety so that they perform impactful procedures more often in community hospitals, which promises to improve treatment and reduce the cost of care while keeping patients closer to their homes and families.


Subject(s)
Clinical Competence , Fluoroscopy , Mentoring/methods , Orthopedic Procedures/education , Simulation Training/methods , Bone Wires , Humans
16.
J Clin Psychiatry ; 80(5)2019 09 03.
Article in English | MEDLINE | ID: mdl-31483958

ABSTRACT

BACKGROUND: Delirium is common and dangerous, yet underdetected and undertreated. Current screening questionnaires are subjective and ineffectively implemented in busy hospital workflows. Electroencephalography (EEG) can objectively detect the diffuse slowing characteristic of delirium, but it is not suitable for high-throughput screening due to size, cost, and the expertise required for lead placement and interpretation. This study hypothesized that an efficient and reliable point-of-care EEG device for high-throughput screening could be developed. METHODS: This prospective study, which measured bispectral EEG (BSEEG) from elderly inpatients to assess their outcomes, was conducted at the University of Iowa Hospitals and Clinics from January 2016 to October 2017. A BSEEG score was defined based on the distribution of 2,938 EEG recordings from the 428 subjects who were assessed for delirium; primary outcomes measured were hospital length of stay, discharge disposition, and mortality. RESULTS: A total of 274 patients had BSEEG score data available for analysis. Delirium and BSEEG score had a significant association (P < .001). Higher BSEEG scores were significantly correlated with length of stay (P < .001 unadjusted, P = .001 adjusted for age, sex, and Charlson Comorbidity Index [CCI] score) as well as with discharge not to home (P < .01). Hazard ratio for survival controlling for age, sex, CCI score, and delirium status was 1.35 (95% CI,1.04 to 1.76; P = .025). CONCLUSIONS: In BSEEG, an efficient and reliable device that provides an objective measurement of delirium status was developed. The BSEEG score is significantly associated with pertinent clinical outcomes of mortality, hospital length of stay, and discharge disposition. The BSEEG score better predicts mortality than does clinical delirium status. This study identified a previously unrecognized subpopulation of patients without clinical features of delirium who are at increased mortality risk.


Subject(s)
Consciousness Monitors , Delirium/diagnosis , Delirium/mortality , Electroencephalography/instrumentation , Aged , Female , Humans , Length of Stay/statistics & numerical data , Male , Patient Discharge/statistics & numerical data , Prognosis , Prospective Studies
17.
Iowa Orthop J ; 39(1): 15-20, 2019.
Article in English | MEDLINE | ID: mdl-31413669

ABSTRACT

Background: There is a wide array of indications for lower extremity amputation (LEA) and inherent variability in operative experiences between surgical residents. Significant variation in resident surgical experience performing LEAs is possible. Objective: To identify inter- and intra-specialty trends and variability in LEA experience in graduating orthopedic surgery, general surgery, and vascular surgery residents from 2007-2017. Methods: Publicly available ACGME case log data for above knee amputation, below knee amputation, and transmetatarsal/ digital amputation procedures from accredited orthopaedic surgery, general surgery, traditional (5+2) vascular surgery and integrated (0+5) vascular surgery residencies was reviewed from 2007-2017. Linear regression analysis was used to identify temporal trends, with statistical significance set at p<0.05. Results: From 2007-2017, the mean number of total LEA, AKA, and BKA performed by graduating orthopaedic surgery residents did not change significantly. The mean number of total LEAs logged by graduating general surgery and integrated (0+5) vascular surgery residents did not change significantly over time (p=0.98, p=0.23, respectively). The mean number of total LEAs logged by traditional (5+2) vascular surgery residents increased from 16.0 to 32.6 (p<0.01). As study year increased, graduating integrated (0+5) and traditional (5+2) vascular surgery residents logged more LEAs relative to graduating orthopaedic surgery and general surgery residents (p<0.01). Conclusions: There is significant variation in resident experience in LEAs between surgical specialties. Integrated vascular surgery residents logged the most LEAs, followed by traditional vascular surgery residents, orthopaedic surgery residents, and general surgery residents. Experience of orthopaedic surgery residents in LEAs has been relatively stable over time.Level of Evidence: IV.


Subject(s)
Amputation, Surgical/education , Clinical Competence , Education, Medical, Graduate/methods , Internship and Residency/methods , Lower Extremity/surgery , Amputation, Surgical/methods , Databases, Factual , Female , General Surgery/education , Humans , Linear Models , Male , Orthopedic Procedures/education , Retrospective Studies , Task Performance and Analysis , United States , Vascular Surgical Procedures/education
18.
J Surg Educ ; 76(6): 1663-1668, 2019.
Article in English | MEDLINE | ID: mdl-31221605

ABSTRACT

OBJECTIVE: The purpose of this study was to (1) examine the feasibility of intraoperative point of view video while performing open and endoscopic carpal tunnel release (CTR), (2) define surgical segments of CTR, and (3) describe the duration of various surgical steps of open versus endoscopic CTR in a teaching setting. DESIGN: Fellowship trained hand surgeons reached consensus on surgical segments for CTR. Adult patients 18 and older previously indicated for CTR in clinic were eligible. Head-mounted point-of-view cameras were worn during endoscopic and open CTR by resident surgeons. Video was reviewed to determine segment duration. Independent sample t tests were used for comparison of duration by technique with statistical significance set as p < 0.05. SETTING: University of Iowa Hospitals and Clinics; 200 Hawkins Dr, Iowa City, IA 52242; Tertiary Academic Medical Center. PARTICIPANTS: Orthopedic Surgery Residents and Orthopedic Surgery Faculty. RESULTS: Surgical segments were defined as incision, dissection of superficial soft tissue structures, transection of the carpal ligament, and surgical incision closure. Twelve of 14 video capture events yielded data. In the teaching setting, the average duration of endoscopic CTR was 609.5 seconds (±111.07) versus 547.75 seconds (±82.06) for open with p value = 0.406. No surgical segments were significantly different. Transition time from dissection to ligament transection differed significantly (p = 0.004) between endoscopic (46.88 seconds ± 19.19) and open (9.0 seconds ± 7.90) CTR. Transition time between ligament transection and closure was significantly different (p = 0.029) among endoscopic (50.5 seconds ± 15.0) and open (26.25 seconds ± 2.99) CTR. CONCLUSIONS: Point-of-view video capture is feasible for the capture of video during a common hand surgery procedure. A method for managing device battery power is necessary for future applications. CTR can be defined as, and described in, individual procedure segments potentially useful for surgical education as well as efficiency improvements. Identification of surgical segments may aid the development of better objective tools for the assessment of surgeon skill and competency for common orthopedic procedures.


Subject(s)
Carpal Tunnel Syndrome/surgery , Endoscopy/education , Internship and Residency/methods , Orthopedic Procedures/education , Video Recording , Feasibility Studies , Humans , Intraoperative Period , Operative Time
19.
Clin Orthop Relat Res ; 477(10): 2189-2198, 2019 10.
Article in English | MEDLINE | ID: mdl-31135546

ABSTRACT

BACKGROUND: Skills training and simulation play an increasingly important role in orthopaedic surgical education. The intent of simulation is to improve performance in the operating room (OR), a trait known as transfer validity. No prior studies have explored how simulator-based wire navigation training can transfer to higher-level tasks. Additionally, there is a lack of knowledge on the format in which wire navigation training should be deployed. QUESTIONS/PURPOSES: (1) Which training methods (didactic content, deliberate practice, or proficiency-based practice) lead to the greatest improvement in performing a wire navigation task? (2) Does a resident's performance using a wire navigation simulator correlate with his or her performance on a higher-level simulation task in a mock OR involving a C-arm, a radiopaque femur model, and a large soft tissue surrogate surrounding the femur? METHODS: Fifty-five residents from four different medical centers participated in this study over the course of 2 years. The residents were divided into three groups: traditional training (included first-year residents from the University of Iowa, University of Minnesota, and the Mayo Clinic), deliberate practice (included first-year residents from the University of Nebraska and the University of Minnesota), and proficiency training (included first-year residents from the University of Minnesota and the Mayo Clinic). Residents in each group received a didactic introduction covering the task of placing a wire to treat an intertrochanteric fracture, and this was considered traditional training. Deliberate practice involved training on a radiation-free simulator that provided specific feedback throughout the practice sessions. Proficiency training used the same simulator to train on specific components of wire navigation, like finding the correct starting point, to proficiency before moving to assessment. The wire navigation simulator uses a camera system to track the wire and provide computer-generated fluoroscopy. After training, task performance was assessed in a mock OR. Residents from each group were assessed in the mock OR based on their use of fluoroscopy, total time, and tip-apex distance. Correlation analysis was performed to examine the relationship between resident performance on the simulator and in the mock OR. RESULTS: Residents in the two simulation-based training groups had a lower tip-apex distance than those in the traditional training group (didactic training tip-apex distance: 24 ± 7 mm, 95% CI, 20-27; deliberate practice tip-apex distance: 16 ± 5 mm, 95% CI, 13-19, p = 0.001; proficiency training tip-apex distance: 15 ± 4 mm, 95% CI, 13-18, p < 0.001). Residents in the proficiency training group used more images than those in the other groups (didactic training: 22 ± 12 images, p = 0.041; deliberate practice: 19 ± 8 images; p = 0.012, proficiency training: 31 ± 14 images). In the two simulation-based training groups, resident performance on the simulator, that is, tip-apex distance, image use, and overall time, was correlated with performance in the mock OR (r-square = 0.15 [p = 0.030], 0.61 [p < 0.001], and 0.43 [p < 0.001], respectively). CONCLUSIONS: As residency programs are designing their curriculum to train wire navigation skills, emphasis should be placed on providing an environment that allows for deliberate practice with immediate feedback about their performance. Simulators such as the one presented in this study offer a safe environment for residents to learn this key skill. LEVEL OF EVIDENCE: Level II, therapeutic study.


Subject(s)
Clinical Competence , Computer Simulation , Orthopedic Procedures/education , Simulation Training , Humans , Operating Rooms , Prospective Studies
20.
J Orthop Trauma ; 33(6): 277-283, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30908342

ABSTRACT

OBJECTIVES: To investigate the radiographic healing of far cortical locking (FCL) construct fixation in distal femur fractures compared with traditional locking plate (LP) constructs. DESIGN: A retrospective cohort of 143 consecutive patients with 146 distal femur fractures. SETTING: Level I trauma center. PATIENTS/PARTICIPANTS: After excluding patients with OTA/AO type B fractures, referred nonunion cases, patients younger than 16 years, and patients with less than 24 weeks of follow-up, 69 patients with 70 total fractures were included for analysis. INTERVENTION: AP and lateral knee radiographs were blinded to type of screws and individually reviewed by 3 orthopaedic trauma surgeons. OUTCOME MEASUREMENTS: The modified RUST (mRUST) score was our primary outcome measure. mRUST scores were assigned at 6, 12, and 24 weeks and final follow-up based on AP and lateral radiographs and compared between FCL and LP groups as a tool for evaluating fracture healing. Secondary outcomes compared between FCL and LP included union rate and postoperative complications. RESULTS: Statistically significant differences in mRUST scores were noted between FCL and LP groups at 6 weeks (P = 0.040), 12 weeks (P = 0.034), 24 weeks (0.044), and final follow-up (P = 0.048). There was no significant difference in union or specific complication rates between the 2 groups. The union rate was 90.5% and 82.1% for the FCL and LP groups, respectively, at final follow-up. CONCLUSIONS: To our knowledge, this is the first comparative study between FCL and LP constructs. The FCL group was noted to have significantly higher mRUST scores at all periods indicating increased callus formation, but the differences seen were small and there were no differences in healing rates or complications between the 2 groups, thus bringing the clinical benefit of FCL into question. Further prospective study designs are needed to compare FCL with LP constructs and to investigate the role of interfragmentary motion on callus formation in distal femur fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Bone Plates , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Fracture Fixation, Internal , Fracture Healing , Adult , Cohort Studies , Fracture Fixation, Internal/instrumentation , Humans , Prosthesis Design , Radiography , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...