1.
Med Phys ; 2018 Jun 14.
Article in English | MEDLINE | ID: mdl-29901835

ABSTRACT

This Special Report presents a description of Geant4-DNA user applications dedicated to the simulation of track structures (TS) in liquid water and associated physical quantities (e.g., range, stopping power, mean free path…). These example applications are included in the Geant4 Monte Carlo toolkit and are available in open access. Each application is described and comparisons to recent international recommendations are shown (e.g., ICRU, MIRD), when available. The influence of physics models available in Geant4-DNA for the simulation of electron interactions in liquid water is discussed. Thanks to these applications, the authors show that the most recent sets of physics models available in Geant4-DNA (the so-called "option4" and "option 6" sets) enable more accurate simulation of stopping powers, dose point kernels, and W-values in liquid water, than the default set of models ("option 2") initially provided in Geant4-DNA. They also serve as reference applications for Geant4-DNA users interested in TS simulations.

2.
Phys Med ; 31(8): 861-874, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26653251

ABSTRACT

Understanding the fundamental mechanisms involved in the induction of biological damage by ionizing radiation remains a major challenge of today's radiobiology research. The Monte Carlo simulation of physical, physicochemical and chemical processes involved may provide a powerful tool for the simulation of early damage induction. The Geant4-DNA extension of the general purpose Monte Carlo Geant4 simulation toolkit aims to provide the scientific community with an open source access platform for the mechanistic simulation of such early damage. This paper presents the most recent review of the Geant4-DNA extension, as available to Geant4 users since June 2015 (release 10.2 Beta). In particular, the review includes the description of new physical models for the description of electron elastic and inelastic interactions in liquid water, as well as new examples dedicated to the simulation of physicochemical and chemical stages of water radiolysis. Several implementations of geometrical models of biological targets are presented as well, and the list of Geant4-DNA examples is described.


Subject(s)
DNA/chemistry , Models, Molecular , Monte Carlo Method , Water/chemistry , Chemical Phenomena , Humans
3.
Radiat Prot Dosimetry ; 166(1-4): 44-8, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25897140

ABSTRACT

Protons are the dominant particles both in galactic cosmic rays and in solar particle events and, furthermore, proton irradiation becomes increasingly used in tumour treatment. It is believed that complex DNA damage is the determining factor for the consequent cellular response to radiation. DNA plasmid pBR322 was irradiated at U120-M cyclotron with 30 MeV protons and treated with two Escherichia coli base excision repair enzymes. The yields of SSBs and DSBs were analysed using agarose gel electrophoresis. DNA has been irradiated in the presence of hydroxyl radical scavenger (coumarin-3-carboxylic acid) in order to distinguish between direct and indirect damage of the biological target. Pure scavenger solution was used as a probe for measurement of induced OH· radical yields. Experimental OH· radical yield kinetics was compared with predictions computed by two theoretical models-RADAMOL and Geant4-DNA. Both approaches use Geant4-DNA for description of physical stages of radiation action, and then each of them applies a distinct model for description of the pre-chemical and chemical stage.


Subject(s)
DNA Damage/radiation effects , DNA/chemistry , DNA/radiation effects , Plasmids/genetics , Protons , Coumarins/chemistry , DNA Repair/genetics , Dose-Response Relationship, Radiation , Escherichia coli Proteins/metabolism , Hydroxyl Radical/chemistry , Kinetics , Plasmids/chemistry
4.
Phys Med Biol ; 59(24): 7691-702, 2014 Dec 21.
Article in English | MEDLINE | ID: mdl-25415376

ABSTRACT

In this study, fragmentation yields of carbon therapy beams are estimated using the Geant4 simulation toolkit version 9.5. Simulations are carried out in a step-by-step mode using the Geant4-DNA processes for each of the major contributing fragments. The energy of the initial beam is taken 400 MeV amu(-1) as this is the highest energy, which is used for medical accelerators and this would show the integral role of secondary contributions in radiotherapy irradiations. The obtained results showed that 64% of the global dose deposition is initiated by carbon ions, while up to 36% is initiated by the produced fragments including all their isotopes. The energy deposition clustering yields of each of the simulated fragments are then estimated using the DBSCAN clustering algorithm and they are compared to the yields of the incident primary beam.


Subject(s)
Carbon/therapeutic use , Heavy Ion Radiotherapy , Nanotechnology/methods , Phantoms, Imaging , Algorithms , Computer Simulation , Humans , Linear Energy Transfer , Radiation Dosage , Radiometry/methods , Relative Biological Effectiveness
5.
Phys Med Biol ; 57(8): 2189-207, 2012 Apr 21.
Article in English | MEDLINE | ID: mdl-22456322

ABSTRACT

The energy and specific energy absorbed in the main cell compartments (nucleus and cytoplasm) in typical radiobiology experiments are usually estimated by calculations as they are not accessible for a direct measurement. In most of the work, the cell geometry is modelled using the combination of simple mathematical volumes. We propose a method based on high resolution confocal imaging and ion beam analysis (IBA) in order to import realistic cell nuclei geometries in Monte-Carlo simulations and thus take into account the variety of different geometries encountered in a typical cell population. Seventy-six cell nuclei have been imaged using confocal microscopy and their chemical composition has been measured using IBA. A cellular phantom was created from these data using the ImageJ image analysis software and imported in the Geant4 Monte-Carlo simulation toolkit. Total energy and specific energy distributions in the 76 cell nuclei have been calculated for two types of irradiation protocols: a 3 MeV alpha particle microbeam used for targeted irradiation and a ²³9Pu alpha source used for large angle random irradiation. Qualitative images of the energy deposited along the particle tracks have been produced and show good agreement with images of DNA double strand break signalling proteins obtained experimentally. The methodology presented in this paper provides microdosimetric quantities calculated from realistic cellular volumes. It is based on open-source oriented software that is publicly available.


Subject(s)
Alpha Particles , Keratinocytes/cytology , Keratinocytes/radiation effects , Monte Carlo Method , Absorption , Cell Line , Cell Nucleus/radiation effects , Humans , Phantoms, Imaging
6.
Phys Med Biol ; 57(1): 209-24, 2012 Jan 07.
Article in English | MEDLINE | ID: mdl-22156022

ABSTRACT

This work presents a Monte Carlo study of energy depositions due to protons, alpha particles and carbon ions of the same linear-energy-transfer (LET) in liquid water. The corresponding track structures were generated using the Geant4-DNA toolkit, and the energy deposition spatial distributions were analyzed using an adapted version of the DBSCAN clustering algorithm. Combining the Geant4 simulations and the clustering algorithm it was possible to compare the quality of the different radiation types. The ratios of clustered and single energy depositions are shown versus particle LET and frequency-mean lineal energies. The estimated effect of these types of radiation on biological tissues is then discussed by comparing the results obtained for different particles with the same LET.


Subject(s)
Linear Energy Transfer , Monte Carlo Method , Water/chemistry , Algorithms , Alpha Particles , Carbon , Protons
7.
Med Phys ; 37(9): 4692-708, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20964188

ABSTRACT

PURPOSE: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H0, H+) and (He0, He+, He2+), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called "GEANT4-DNA" physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. METHODS: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. RESULTS: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. CONCLUSIONS: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.


Subject(s)
Models, Theoretical , Water , DNA Damage , Elasticity , Electrons , Helium , Monte Carlo Method , Protons , Radiometry , Scattering, Radiation , Software