Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Am Heart Assoc ; : e030147, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38842331

ABSTRACT

BACKGROUND: In nonvalvular atrial fibrillation (NVAF), the left atrial appendage (LAA) is the source of thrombus in up to 90% of patients. LAA pseudothrombus (LAAPT), defined as a filling defect on the initial but not the 60-second delayed acquisition on cardiovascular computed tomography scan (CCT), is a recognized phenomenon in NVAF, with unknown clinical relevance. We aimed to determine the relationship between LAAPT and history of stroke in patients with NVAF. METHODS AND RESULTS: The study included 213 consecutive patients with NVAF undergoing CCT who were assessed for LAAPT. LA and LAA dimensions and LAA morphology correlated with clinical demographics including cardiovascular risk factors, history of stroke, thromboembolic stroke, and transient ischemic attack. Mean age (±SD) was 65.1±10.5 years (range 31-89) and 150 of 213 (70.4%) were men. LAAPT was present in 59 of 213 (27.7%) patients. Greater mean LAA ostium area (5.7 versus 4.5, P<0.001), greater mean LAA ostium area:curved length (0.11 versus 0.08, P<0.001), increased LAA volume (14.0 versus 10.2, P<0.001), and lower mean LAA tortuosity index (1.17 versus 1.38, P<0.001) were all associated with the presence of LAAPT. On multivariable analysis, LAAPT on CCT (odds ratio [OR], 3.20 [95% CI, 1.40-7.20]; P<0.006) and higher CHA2DS2-VASc score (OR, 1.65 [95% CI, 1.16-2.35]; P=0.01) were associated with all strokes, with LAAPT remaining a statistically significant risk factor even after adjustment for CHA2DS2-VASc score. CONCLUSIONS: LAAPT on CCT is common in patients with NVAF. It has a strong positive association with stroke prevalence, even after adjustment for CHA2DS2-VASc score. LAAPT on CCT may potentially allow further stratification for stroke risk, additive to the CHA2DS2-VASc score.

2.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38030358

ABSTRACT

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Thrombosis , Humans , Female , Incidence , Atrial Appendage/diagnostic imaging , Treatment Outcome , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Thromboembolism/diagnostic imaging , Thromboembolism/epidemiology , Thromboembolism/etiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/etiology
3.
Pacing Clin Electrophysiol ; 45(4): 481-490, 2022 04.
Article in English | MEDLINE | ID: mdl-35043404

ABSTRACT

BACKGROUND: Conventional superior access for cardiac implantable electronic devices (CIEDs) is not always possible and femoral CIEDs (F-CIED) are an alternative option when leadless systems are not suitable. The long-term outcomes and extraction experiences with F-CIEDs, in particular complex F-CIED (ICD/CRT devices), remain poorly understood. METHODS: Patients referred for F-CIEDs implantation between 2002 and 2019 at two tertiary centers were included. Early complications were defined as ≤30 days following implant and late complications >30 days. RESULTS: Thirty-one patients (66% male; age 56 ± 20 years; 35% [11] patients with congenital heart disease) were implanted with F-CIEDs (10 ICD/CRT and 21 pacemakers). Early complications were observed in 6.5% of patients: two lead displacements. Late complications at 6.8 ± 4.4 years occurred in 29.0% of patients. This was higher with complex F-CIED compared to simple F-CIED (60.0% vs. 14.3%, p = .02). Late complications were predominantly generator site related (n = 8, 25.8%) including seven infections/erosions and one generator migration. Eight femoral generators and 14 leads (median duration in situ seven [range 6-11] years) were extracted without complication. CONCLUSIONS: Procedural success with F-CIEDs is high with clinically acceptable early complication rates. There is a notable risk of late complications, particularly involving the generator site of complex devices following repeat femoral procedures. Extraction of chronic F-CIED in experienced centers is feasible and safe.


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Pacemaker, Artificial , Adult , Aged , Electronics , Female , Humans , Male , Middle Aged , Retrospective Studies
4.
J Interv Card Electrophysiol ; 63(2): 259-266, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33638777

ABSTRACT

PURPOSE: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. METHODS: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. RESULTS: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). CONCLUSION: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheters , Electrophysiologic Techniques, Cardiac , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
5.
Heart Rhythm ; 19(1): 61-69, 2022 01.
Article in English | MEDLINE | ID: mdl-34583060

ABSTRACT

BACKGROUND: A novel aggregated multiposition noncontact mapping (AMP-NCM) algorithm is proposed to diagnose cardiac arrhythmias. OBJECTIVE: The purpose of this study was to computationally determine an accuracy threshold and to compare the accuracy and clinical utility of AMP-NCM to gold standard contact mapping. METHODS: In a cellular automata model, the number of catheter positions and chamber coverage were varied to establish accuracy requirements for clinically relevant AMP-NCM. This guided the clinical study protocol. In a prospective cohort of patients with atrial tachycardia (AT), noncontact mapping (NCM) recordings from a single position (SP) and multiple positions were compared to contact mapping with a high-density multipolar catheter using morphology and timing differences of reconstructed signals. Identification of AT mechanisms and ablation targets using both AMP-NCM and contact mapping were randomly evaluated by 5 blinded reviewers. RESULTS: AMP-NCM accuracy was asymptotic at 60 catheter positions in computational modeling. Twenty patients (age 65 ± 12 years; 19 male) with 26 ATs (5 focal, 21 reentrant) were studied. Morphologic correlation of signals derived from AMP-NCM was significantly better than those from SP-NCM compared to contact signals (median 0.93 vs 0.76; P <.001). AMP-NCM generated maps more rapidly than contact mapping (3 ± 1 minutes vs 13 ± 6 minutes; P <.001) and correctly diagnosed AT mechanisms in 25 of 26 maps (96%). Overall, 80% of arrhythmia mechanisms were correctly identified using AMP-NCM by blinded reviewers. CONCLUSION: Once 60 catheter positions were achieved, AMP-NCM successfully diagnosed mechanisms of AT and identified treatment sites equal to gold standard contact mapping in 3 minutes of procedural time.


Subject(s)
Computer Simulation , Epicardial Mapping , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Aged , Algorithms , Female , Humans , Male , Prospective Studies
6.
J Am Coll Cardiol ; 78(4): 297-313, 2021 07 27.
Article in English | MEDLINE | ID: mdl-34294267

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) has been considered an Achilles' heel of left atrial appendage occlusion (LAAO). However, data on DRT prediction remain limited. OBJECTIVES: This study constructed a DRT registry via a multicenter collaboration aimed to assess outcomes and predictors of DRT. METHODS: Thirty-seven international centers contributed LAAO cases with and without DRT (device-matched and temporally related to the DRT cases). This study described the management patterns and mid-term outcomes of DRT and assessed patient and procedural predictors of DRT. RESULTS: A total of 711 patients (237 with and 474 without DRT) were included. Follow-up duration was similar in the DRT and no-DRT groups, median 1.8 years (interquartile range: 0.9-3.0 years) versus 1.6 years (interquartile range: 1.0-2.9 years), respectively (P = 0.76). DRTs were detected between days 0 to 45, 45 to 180, 180 to 365, and >365 in 24.9%, 38.8%, 16.0%, and 20.3% of patients. DRT presence was associated with a higher risk of the composite endpoint of death, ischemic stroke, or systemic embolization (HR: 2.37; 95% CI, 1.58-3.56; P < 0.001) driven by ischemic stroke (HR: 3.49; 95% CI: 1.35-9.00; P = 0.01). At last known follow-up, 25.3% of patients had DRT. Discharge medications after LAAO did not have an impact on DRT. Multivariable analysis identified 5 DRT risk factors: hypercoagulability disorder (odds ratio [OR]: 17.50; 95% CI: 3.39-90.45), pericardial effusion (OR: 13.45; 95% CI: 1.46-123.52), renal insufficiency (OR: 4.02; 95% CI: 1.22-13.25), implantation depth >10 mm from the pulmonary vein limbus (OR: 2.41; 95% CI: 1.57-3.69), and non-paroxysmal atrial fibrillation (OR: 1.90; 95% CI: 1.22-2.97). Following conversion to risk factor points, patients with ≥2 risk points for DRT had a 2.1-fold increased risk of DRT compared with those without any risk factors. CONCLUSIONS: DRT after LAAO is associated with ischemic events. Patient- and procedure-specific factors are associated with the risk of DRT and may aid in risk stratification of patients referred for LAAO.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Postoperative Complications/etiology , Registries , Septal Occluder Device/adverse effects , Thrombosis/etiology , Aged , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal , Europe/epidemiology , Female , Follow-Up Studies , Heart Diseases/diagnosis , Heart Diseases/epidemiology , Heart Diseases/etiology , Humans , Incidence , Male , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Risk Factors , Survival Rate/trends , Thrombosis/diagnosis , Thrombosis/epidemiology , Time Factors , Treatment Outcome
7.
Heart Rhythm ; 18(6): 862-870, 2021 06.
Article in English | MEDLINE | ID: mdl-33610744

ABSTRACT

BACKGROUND: Noncontact charge-density mapping allows rapid real-time global mapping of atrial fibrillation (AF), offering the opportunity for a personalized ablation strategy. OBJECTIVE: The purpose of this study was to compare the 2-year outcome of an individualized strategy consisting of pulmonary vein isolation (PVI) plus core-to-boundary ablation (targeting the conduction pattern core with an extension to the nearest nonconducting boundary) guided by charge-density mapping, with an empirical PVI plus posterior wall electrical isolation (PWI) strategy. METHODS: Forty patients (age 62 ± 12 years; 29 male) with persistent AF (10 ± 5 months) prospectively underwent charge-density mapping-guided PVI, followed by core-to-boundary stepwise ablation until termination of AF or depletion of identified cores. Freedom from AF/atrial tachycardia (AT) at 24 months was compared with a propensity score-matched control group of 80 patients with empirical PVI + PWI guided by conventional contact mapping. RESULTS: Acute AF termination occurred in 8 of 40 patients after charge-density mapping-guided PVI alone and in 21 of the remaining 32 patients after core-to-boundary ablation in the study cohort, compared with 8 of 80 (10%) in the control cohort (P <.001). On average, 2.2 ± 0.6 cores were ablated post-PVI before acute AF termination. At 24 months, freedom from AF/AT after a single procedure was 68% in the study group vs 46% in the control group (P = .043). CONCLUSION: An individualized ablation strategy consisting of PVI plus core-to-boundary ablation guided by noncontact charge-density mapping is a feasible and effective strategy for treating persistent AF, with a favorable 24-month outcome.


Subject(s)
Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Catheter Ablation/standards , Heart Conduction System/physiopathology , Heart Rate/physiology , Pulmonary Veins/surgery , Surgery, Computer-Assisted/standards , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Propensity Score , Prospective Studies , Recurrence , Time Factors , Treatment Outcome
8.
Pacing Clin Electrophysiol ; 44(2): 318-326, 2021 02.
Article in English | MEDLINE | ID: mdl-33377500

ABSTRACT

OBJECTIVES: To study how left atrial appendage electrical isolation (LAAEI) impacts atrial dominant frequency (DF) in patients with long-standing persistent atrial fibrillation (LSPAF). BACKGROUND: LAAEI is associated with a high probability of freedom from atrial fibrillation (AF) and spectral analysis may identify high-frequency sources. How LAAEI impacts the AF dynamics and the subgroup of LSPAF patients in whom LAAEI would be most beneficial, is unclear. METHODS: Twenty patients with LSPAF were included in the study. Fast Fourier transforms (FFT) were performed on atrial electrograms recorded from 13 sites in the LA and RA. The highest peak frequency was defined as DF. RESULTS: There was no significant difference in DF between atrial sites except for at the superior vena cava which had the lowest DF at baseline. Stepwise ablation consisting of circumferential pulmonary vein isolation and a linear ablation set of mitral isthmus and roof significantly reduced the DF within the coronary sinus (CS) (5.93 ± 0.98 Hz vs. 5.09 ± 0.72 Hz, p < .05) and the LA posterior wall (LApos) (6.26 ± 0.92 Hz vs. 5.43 ± 0.98 Hz, p < .01). LAAEI preferentially further decreased the DF at the LApos (p < .01), but not at the CS. In cases where there was < 13.6% reduction in the DF of the LApos following the stepwise ablation, the addition of LAAEI was associated with an increased restoration of sinus rhythm (55%, p < .05). CONCLUSION: LAAEI in addition to stepwise ablation results in further reduction of the DF in the LApos, which is associated with acute termination of AF and favorable ablation outcome.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation/methods , Aged , Atrial Fibrillation/physiopathology , Cardiac Surgical Procedures/methods , Clinical Protocols , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged
9.
Europace ; 22(1): 5-18, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31578542

ABSTRACT

For many years, the left atrial appendage (LAA) was considered a dormant embryological remnant; however, it is a structurally complex and functional organ that contributes to cardiac haemodynamic changes and volume homeostasis through both its contractile properties and neurohormonal peptide secretion. When dysfunctional, the LAA contributes to thrombogenesis and subsequent increased predisposition to cardioembolic events. Consequently, the LAA has gained much attention as a therapeutic target to lower this risk. In addition, attention has focused on the LAA in its role as an electrical trigger for atrial tachycardia and atrial fibrillation with ablation of the LAA to achieve electrical isolation showing promising results in the maintenance of sinus rhythm. This in-depth review explores the structure, physiology and pathophysiology of the LAA, as well as LAA intervention and their sequelae.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Causality , Humans
10.
Heart ; 104(6): 502-508, 2018 03.
Article in English | MEDLINE | ID: mdl-28954836

ABSTRACT

OBJECTIVE: To assess the prevalence of short corrected QT (QTc) intervals and its impact on short QT syndrome (SQTS) diagnosis using different QT correction formulae. METHODS: Observational study. The prevalence of short QTc intervals was estimated using four different QT correction formulae in 14 662 young adults from the 'Sudden Cardiac Death Screening of Risk FactOrS' (SCD-SOS) cohort. Then, using data from this cohort and the pooled-cohort analysed by Gollob et al, comprising 61 patients with SQTS, we assessed the impact of the different QTc correction formulae on SQTS probability and diagnosis based on the Expert Consensus recommendations (QTc ≤330 ms or QTc 330-360 ms+1 additional risk feature). RESULTS: The prevalence of individuals with a QTc ≤330 and ≤320 ms in the SCD-SOS cohort was extremely low (≤0.07% and≤0.02%, respectively), and these were more frequently identified by the Framingham correction. The different QTc correction formulae led to a shift in SQTS probability in 5%-10% of individuals in both the SCD-SOS and Gollob cohort). Intermediate probability individuals were rare (<0.1%), and no high-SQTS probability individuals were identified in the SCD-SOS cohort. Based on Consensus criteria, instead of 12 (0.08%) individuals being diagnosed with SQTS using the Bazett equation, a different number of individuals would meet diagnostic criteria with the other formulae: 11 (0.08%) using Fridericia, 9 (0.06%) with Hodges and 16 (0.11%) using the Framingham equation. CONCLUSION: Prevalence of SQTS in the apparently healthy adult population is low. Applying different QTc correction formulae leads to significant reclassification of SQTS probability and their impact on predicting outcomes should be assessed.


Subject(s)
Arrhythmias, Cardiac , Death, Sudden, Cardiac , Electrocardiography/methods , Adult , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Female , Heart Rate , Humans , Male , Prevalence , Probability , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...