Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1258: 94-100, 2012 Oct 05.
Article in English | MEDLINE | ID: mdl-22939460

ABSTRACT

In this research seven ACE inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, benazepril) were studied to evaluate the correlation between their absorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS) and reversed-phase thin-layer chromatography (RP-TLC) hydrophobicity data (φ(0) or C(0) parameters, respectively). Their absorption values were in the range of 25-60%, while calculated KOWWIN logP values were from -0.94 to 6.61. Additionally, perindopril (absorption 70%, KOWWIN logP 2.59) and moexipril (absorption 22%, KOWWIN logP 3.36) were introduced for the theoretical considerations due to their high/low absorption values which were on the opposite sites in comparison with the majority of ACE inhibitors (25-60%). In the theoretical considerations it was shown that the solubility data (logS) must be considered, as independent variable, simultaneously with KOWWIN logP to obtain reliable correlation (r(2)=0.7208) between absorption and ACE inhibitors lipophilicity. As the main topic of this study, the relationships between literature available and absorption data predicted by multiple linear regression (MLR) using logS values besides chromatographically obtained hydrophobicity parameters C(0) (r(2)=0.6424) or φ(0) (r(2)=0.6762) were studied proving that these parameters could be used in ACE inhibitors absorption evaluation. The UHPLC-MS method provides the direct application of experimentally obtained φ(0) values that is the advantage of this method. For better MLR correlation of ACE inhibitors absorption with C(0) parameters (RP-TLC) and logS, mathematical conversion of C(0) parameters to logC(0) values was necessary based on requisite for probability value of regression analysis (P<0.05). The accordance and differences between hydrophobicity parameters obtained by UHPLC-MS and RP-TLC were defined.


Subject(s)
Angiotensin-Converting Enzyme Inhibitors/chemistry , Chromatography, High Pressure Liquid/methods , Chromatography, Reverse-Phase/methods , Tandem Mass Spectrometry/methods , Absorption , Angiotensin-Converting Enzyme Inhibitors/analysis , Angiotensin-Converting Enzyme Inhibitors/pharmacokinetics , Humans , Hydrophobic and Hydrophilic Interactions , Linear Models
2.
Molecules ; 17(1): 480-91, 2012 Jan 05.
Article in English | MEDLINE | ID: mdl-22222907

ABSTRACT

The permeation properties of twenty newly synthesized α-alkoxyalkanoyl and α-aryloxyalkanoyl C-21 esters of standard corticosteroids: Fluocinolone acetonide, dexamethasone, triamcinolone acetonide and hydrocortisone were established using a PAMPA assay (70% silicone oil and 30% isopropyl myristate). The data were compared with parent corticosteroids with addition of mometasone furoate and hydrocortisone acetate. All newly synthesized corticosteroid C-21 esters have effective permeability coefficients higher then -6, mostly followed with high values of retention factors and low permeation. The examined compounds were grouped through relationship between obtained retention factors and permeation parameters (groups I-III). The classification confirmed group I (membrane retentions as well as permeation lower then 30%) for all corticosteroid standards except mometasone furoate, a potent topical corticosteroid which, with high membrane retention (81%) and low permeation (7.7%) fits into group III. The largest number of new synthesized corticosteroids C-21 esters, among them all fluocinolone acetonide C-21 esters, have high membrane retentions (32.4%-86.5%) and low permeations (1.3%-27.1%), fitting in group III. The classification was related to previously obtained anti-inflammatory activity data for the fluocinolone acetonide C-21 esters series. According to the PAMPA results the new synthesized esters could be considered as potential new prodrugs with useful benefit/risk ratio.


Subject(s)
Esters/chemistry , Membranes, Artificial , Models, Biological , Pregnanes/chemistry , Prodrugs/chemistry , Esters/chemical synthesis , Esters/standards , Humans , Myristates/chemistry , Permeability , Pregnanes/chemical synthesis , Pregnanes/standards , Prodrugs/chemical synthesis , Prodrugs/standards , Reference Standards , Silicone Oils/chemistry , Skin Absorption
3.
Molecules ; 16(3): 2658-71, 2011 Mar 23.
Article in English | MEDLINE | ID: mdl-21441868

ABSTRACT

In this study the solvolysis of newly synthesized fluocinolone acetonide C-21 esters was analysed in comparison with fluocinonide during a 24-hour period of time. The solvolysis was performed in an ethanol-water (90:10 v/v) mixture using the excess of NaHCO3. The solvolytic mixtures of each investigated ester have been assayed by a RP-HPLC method using isocratic elution with methanol-water (75:25 v/v); flow rate 1 mL/min; detection at 238 nm; temperature 25 °C. Solvolytic rate constants were calculated from the obtained data. Geometry optimizations and charges calculations were carried out by Gaussian W03 software. A good correlation (R = 0.9924) was obtained between solvolytic rate constants and the polarity of the C-O2 bond of those esters. The established relation between solvolytic rate constant (K) and lipophilicity (cLogP) with experimental anti-inflammatory activity could be indicative for topical corticosteroid prodrug activation.


Subject(s)
Fluocinolone Acetonide/chemistry , Prodrugs/pharmacokinetics , Esters , Kinetics , Solvents
SELECTION OF CITATIONS
SEARCH DETAIL
...