Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Eur Radiol ; 27(6): 2532-2537, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27678131

ABSTRACT

OBJECTIVES: To evaluate the potential role of dual energy CT (DECT) to visualize antiangiogenic treatment effects in patients with metastatic renal cell cancer (mRCC) while treated with tyrosine-kinase inhibitors (TKI). METHODS: 26 patients with mRCC underwent baseline and follow-up single-phase abdominal contrast enhanced DECT scans. Scans were performed immediately before and 10 weeks after start of treatment with TKI. Virtual non-enhanced (VNE) and colour coded iodine images were generated. 44 metastases were measured at the two time points. Hounsfield unit (HU) values for VNE and iodine density (ID) as well as iodine content (IC) in mg/ml of tissue were derived. These values were compared to the venous phase DECT density (CTD) of the lesions. Values before and after treatment were compared using a paired Student's t test. RESULTS: Between baseline and follow up, mean CTD and DECT-derived ID both showed a significant reduction (p < 0.005). The relative reduction measured in percent was significantly greater for ID than for CTD (49.8 ± 36,3 % vs. 29.5 ± 20.8 %, p < 0.005). IC was also significantly reduced under antiangiogenic treatment (p < 0.0001). CONCLUSIONS: Dual energy CT-based quantification of iodine content of mRCC metastases allows for significantly more sensitive and reproducible detection of antiangiogenic treatment effects. KEY POINTS: • A sign of tumour response to antiangiogenic treatment is reduced tumour perfusion. • DECT allows visualizing iodine uptake, which serves as a marker for vascularization. • More sensitive detection of antiangiogenic treatment effects in mRCC is possible.


Subject(s)
Angiogenesis Inhibitors/therapeutic use , Carcinoma, Renal Cell/drug therapy , Indoles/therapeutic use , Kidney Neoplasms/drug therapy , Pyrroles/therapeutic use , Aged , Carcinoma, Renal Cell/diagnostic imaging , Contrast Media/metabolism , Female , Humans , Iodine/metabolism , Kidney Neoplasms/diagnostic imaging , Male , Middle Aged , Neoplasm Metastasis , Prospective Studies , Protein-Tyrosine Kinases/antagonists & inhibitors , Sunitinib , Tomography, X-Ray Computed/methods , Treatment Outcome
2.
Eur Radiol ; 24(11): 2709-18, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25192795

ABSTRACT

OBJECTIVES: Multicentre evaluation of the precision of semi-automatic 2D/3D measurements in comparison to manual, linear measurements of lymph nodes regarding their inter-observer variability in multi-slice CT (MSCT) of patients with lymphoma. METHODS: MSCT data of 63 patients were interpreted before and after chemotherapy by one/two radiologists in five university hospitals. In 307 lymph nodes, short (SAD)/long (LAD) axis diameter and WHO area were determined manually and semi-automatically. Volume was solely calculated semi-automatically. To determine the precision of the individual parameters, a mean was calculated for every lymph node/parameter. Deviation of the measured parameters from this mean was evaluated separately. Statistical analysis entailed intraclass correlation coefficients (ICC) and Kruskal-Wallis tests. RESULTS: Median relative deviations of semi-automatic parameters were smaller than deviations of manually assessed parameters, e.g. semi-automatic SAD 5.3 vs. manual 6.5 %. Median variations among different study sites were smaller if the measurement was conducted semi-automatically, e. g. manual LAD 5.7/4.2 % vs. semi-automatic 3.4/3.4 %. Semi-automatic volumetry was superior to the other parameters (2.8 %). CONCLUSIONS: Semi-automatic determination of different lymph node parameters is (compared to manually assessed parameters) associated with a slightly greater precision and a marginally lower inter-observer variability. These results are with regard to the increasing mobility of patients among different medical centres and in relation to the quality management of multicentre trials of importance. KEY POINTS: • In a multicentre setting, semi-automatic measurements are more accurate than manual assessments. • Lymph node volumetry outperforms all other semi-automatically and manually performed measurements. • Use of semi-automatic lymph node analyses can reduce the inter-observer variability.


Subject(s)
Lymph Nodes/diagnostic imaging , Lymphoma/diagnostic imaging , Multidetector Computed Tomography/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , ROC Curve , Reproducibility of Results , Young Adult
3.
Rofo ; 186(8): 768-79, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24497088

ABSTRACT

PURPOSE: Comparison of manual one-/bi-dimensional measurements versus semi-automatically derived one-/bi-dimensional and volumetric measurements for therapy response evaluation of malignant lymphoma during CT follow-up examinations in a multicenter setting. MATERIALS AND METHODS: MSCT data sets of patients with malignant lymphoma were evaluated before (baseline) and after two cycles of chemotherapy (follow-up) at radiological centers of five university hospitals. The long axis diameter (LAD), the short axis diameter (SAD) and the bi-dimensional WHO of 307 target lymph nodes were measured manually and semi-automatically using dedicated software. Lymph node volumetry was performed semi-automatically only. The therapeutic response was evaluated according to lymphoma-adapted RECIST. RESULTS: Based on a single lymph node, semi-automatically derived multidimensional parameters allowed for significantly more accurate therapy response classification than the manual or the semi-automatic unidimensional parameters. Incorrect classifications were reduced by up to 9.6%. Compared to the manual approach, the influence of the study center on correct therapy classification is significantly less relevant when using semi-automatic measurements. CONCLUSION: Semi-automatic volumetry and bi-dimensional WHO significantly reduce the number of incorrectly classified lymphoma patients by approximately 9.6% in the multicenter setting in comparison to linear parameters. Semi-automatic quantitative software tools may help to significantly reduce wrong classifications that are associated with the manual assessment approach. KEY POINTS: ► Semi-automatic volumetry and bi-dimensional WHO significantly reduce the number of incorrectly classified lymphoma patients ► Manual lymph node evaluation with uni-dimensional parameters is inferior to semi-automatic analysis in a multicenter setting ► Semi-automatic quantitative software tools should be introduced in clinical study evaluation.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Hodgkin Disease/diagnostic imaging , Hodgkin Disease/drug therapy , Image Interpretation, Computer-Assisted/methods , Lymphoma, Non-Hodgkin/diagnostic imaging , Lymphoma, Non-Hodgkin/drug therapy , Multidetector Computed Tomography/methods , Adult , Aged , Aged, 80 and over , Female , Hodgkin Disease/pathology , Humans , Lymphoma, Non-Hodgkin/pathology , Male , Middle Aged , Neoplasm Staging , Radiation Dosage , Retrospective Studies , Treatment Outcome , Young Adult
4.
Br J Radiol ; 86(1021): 20120224, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23255541

ABSTRACT

OBJECTIVE: To compare radiation exposure and image quality of oncological staging multidetector CT (MDCT) examinations of the chest, abdomen and pelvis with and without iterative reconstruction (IR). METHODS: 40 patients with known malignancy underwent staging CT examinations at two time points. Both CT scans were performed on the same scanner (SOMATOM® Definition Flash, Siemens Healthcare, Forchheim, Germany). For the baseline scan, the tube current-time product was set to 250 mAs [image reconstruction: filtered back projection (FBP)] and for the follow-up scan to 150 mAs [reconstruction: iterative reconstruction (IR)]. Effective radiation doses were estimated based on dose-length products for both baseline and follow-up. Noise measurements in defined regions were compared for FBP and IR. Images were also subjectively evaluated for image quality by three radiologists with different levels of experience. RESULTS: Dose reduction was 44.4±8.2% for reduced-dose CT scans with IR compared with baseline with FBP. Image noise was not significantly different between images reconstructed with FBP and IR. The subjective quality of standard-dose FBP images and reduced-dose iteratively reconstructed CT images were identical. CONCLUSION: Our results show the dose-reducing potential of IR of CT image data in oncological patients. ADVANCES IN KNOWLEDGE: The algorithm tested in the present scientific study allows a >45% dose reduction at maintained image quality.


Subject(s)
Algorithms , Neoplasm Staging/methods , Neoplasms/pathology , Radiation Dosage , Radiation Protection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Humans , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Young Adult
5.
Radiologe ; 52(6): 519-28, 2012 Jun.
Article in German | MEDLINE | ID: mdl-22618624

ABSTRACT

CLINICAL/METHODICAL ISSUE: Rectal cancer restaging after neoadjuvant therapy is based on two principles: an anatomic definition of the tumor allowing surgical planning and prognostic stage grouping. STANDARD RADIOLOGICAL METHODS: Emerging data suggest that reassessment using a combination of different imaging modalities may help to provide valuable prognostic information before definitive surgery. METHODICAL INNOVATIONS: Perfusion computed tomography (CT) may provide special information regarding tumor vascularity. PERFORMANCE: Evaluation of therapy response, especially of the circumferential resection margin (CRM) is necessary for surgical planning. ACHIEVEMENTS: For local staging high-resolution and diffusion-weighted magnetic resonance imaging has proven to be of high diagnostic accuracy. PRACTICAL RECOMMENDATIONS: The M status should be assessed using multidetector computed tomography (MDCT) according to response evaluation criteria in solid tumors (RECIST) while lymph node evaluation requires either magnetic resonance imaging or positron emission tomography/computed tomography scanning.


Subject(s)
Magnetic Resonance Imaging/methods , Rectal Neoplasms/pathology , Rectal Neoplasms/therapy , Tomography, X-Ray Computed/methods , Humans , Neoadjuvant Therapy , Neoplasm Staging , Prognosis , Treatment Outcome
6.
Radiologe ; 51(5): 352-65, 2011 May.
Article in German | MEDLINE | ID: mdl-21512763

ABSTRACT

Obesity is an increasing problem faced by the healthcare system. In managing obesity, bariatric surgery is becoming more important with evidence showing a reduction in long-term morbidity and mortality. There are special challenges faced by the radiology department in providing an imaging service for this population of patients, from technical requirements through to the interpretation of post-surgical images. This article provides an overview of the most frequently performed procedures, normal postoperative imaging findings and the appearance of common complications.


Subject(s)
Bariatric Surgery/adverse effects , Bariatric Surgery/methods , Diagnostic Imaging/methods , Gastrointestinal Diseases/diagnosis , Gastrointestinal Diseases/etiology , Obesity/diagnosis , Obesity/surgery , Humans , Obesity/complications , Postoperative Care/methods
7.
J Gastrointest Surg ; 13(3): 423-31, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19130152

ABSTRACT

INTRODUCTION: Neuronal reflex inhibition of gastrointestinal motility is a key mechanism in the development of postoperative ileus (POI). The aim of our study was to determine whether intestinal afferent nerve fibers are sensitized during the first hours after surgery contributing to this mechanism. METHODS: Under enflurane anesthesia, C57BL/6 mice underwent laparotomy followed by sham treatment or standardized small bowel manipulation to induce POI. After 1, 3, or 9 h, extracellular multi-unit mesenteric afferent nerve recordings were performed in vitro from 2 cm segments of jejunum (subgroups n = 6) superfused with Kreb's buffer (32 degrees C, gassed with O(2)/CO(2) mixture). Segments were cannulated to monitor luminal pressure and intestinal motility. Afferent impulses as response to bradykinin (0.5 microM) and to mechanical ramp distension of the intestinal lumen from 0 to 80 cmH(2)O were recorded. RESULTS: At 1 h, amplitudes of intestinal contractions were 0.8 +/- 0.2 cmH(2)O after induction of POI and 5.0 +/- 0.8 cmH(2)O in sham controls (mean +/- SEM; p < 0.01). A similar difference was observed for segments harvested at 3 and 9 h. Afferent firing to serosal bradykinin was increased at 1, 3, and 9 h in POI segments compared to sham controls (p < 0.05 at 1 h, p < 0.01 at 3 and 9 h). During distension with high pressures, afferent firing rate was increased at 1 and 3 h in segments after induction of POI compared to sham controls. Nine hours postoperatively, contracted and dilated segments were observed during POI that were investigated separately. While afferent firing in dilated segments was increased to 176 +/- 16 imp s(-1) at 80 cmH(2)O luminal distension (p < 0.01), it was 46 +/- 5 imp s(-1) in contracted segments (p < 0.001) compared to 77 +/- 4 imp s(-1) in sham controls. CONCLUSIONS: Afferent firing to bradykinin and high threshold distension is augmented in the early phase of POI. As these stimuli are known to sensitize predominantly spinal afferents, this mechanism may contribute to reflex inhibition of intestinal motility during POI.


Subject(s)
Gastrointestinal Motility/physiology , Ileus/etiology , Ileus/physiopathology , Jejunal Diseases/physiopathology , Neurons, Afferent/physiology , Postoperative Complications , Afferent Pathways/physiopathology , Animals , Bradykinin , Jejunal Diseases/etiology , Male , Mice , Mice, Inbred C57BL , Time Factors
8.
Neurogastroenterol Motil ; 21(3): 322-34, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19077108

ABSTRACT

Evidence exists that visceral afferent sensitivity is subject to regulatory mechanisms. We hypothesized that afferent sensitivity is decreased in the small intestine during intestinal inflammation by an inducible nitric oxide synthase (iNOS)-dependent mechanism. C57BL/6 mice were injected twice with vehicle or 60 mg kg(-1) indomethacin subcutaneously to induce intestinal inflammation. Afferent sensitivity was recorded on day 3 from a 2-cm segment of jejunum in vitro by extracellular multi-unit afferent recordings from the mesenteric nerve bundle. In subgroups (n = 6), iNOS was inhibited selectively by L-N6-(1-iminoethyl)-lysine (L-NIL) given either chronically from day 1-3 (3 mg kg(-1) twice daily i.p.) or acutely into the organ bath (30 micromol L(-1)). The indomethacin-induced increase of macroscopic and microscopic scores of intestinal inflammation (both P < 0.05) were unchanged after pretreatment with L-NIL. Peak afferent firing following bradykinin (0.5 micromol L(-1)) was 55 +/- 8 impulse s(-1) during inflammation vs 97 +/- 7 impulse s(-1) in controls (P < 0.05). Normal firing rate was preserved following L-NIL pretreatment (112 +/- 16 impulse s(-1)) or acute administration of L-NIL (108 +/- 14 impulse s(-1)). A similar L-NIL dependent reduction was observed for 5-HT (250 micromol L(-1)) and mechanical ramp distension from 20 to 60 cmH(2)O (both P < 0.05). Intraluminal pressure peaks were decreased to 0.66 +/- 0.1 cmH(2)O during inflammation compared to 2.51 +/- 0.3 in controls (P < 0.01). Afferent sensitivity is decreased by an iNOS-dependent mechanism during intestinal inflammation which appears to be independent of the inflammatory response. This suggests that iNOS-dependent nitric oxide production alters afferent sensitivity during inflammation by interfering with signal transduction to afferent nerves rather than by attenuating intestinal inflammation.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/pharmacology , Indomethacin/pharmacology , Inflammation/chemically induced , Jejunum , Neurons, Afferent/physiology , Nitric Oxide Synthase Type II/metabolism , Animals , Bradykinin/pharmacology , Electrophysiology , Humans , Inflammation/pathology , Jejunum/drug effects , Jejunum/innervation , Jejunum/pathology , Lysine/analogs & derivatives , Lysine/pharmacology , Male , Mice , Mice, Inbred C57BL , Neurons, Afferent/drug effects , Nitric Oxide Synthase Type II/antagonists & inhibitors , Serotonin/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...