Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Mass Spectrom (Chichester) ; 24(1): 96-107, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29160094

ABSTRACT

The main advantages of laser sampling are associated with following features: sample preparations as well as consumables are not needed, low risk of sample contamination, good spatial resolution. In mass spectrometry, high laser irradiance can be used for both ablation and ionization processes. The method is especially profitable in time-of-flight mass spectrometry. A new principle of constructing laser ionization time-of-flight mass spectrometer based on wedge-shaped ion mirrors and the absence of electrostatic ion acceleration before mass analysis is discussed. Among advantages of the analyzer there are ability to provide temporal focusing of ions in a wide energy range (±20%), compactness of the analyzer, and minimization of the requirements for power supplies. The approach is expected to be profitable for standardless elemental analysis of solid samples, which should be possible at laser irradiation power density more than 3 × 109 W/cm2 that ensures complete ionization of all elements in a laser plasma. The analytical signal of each element is formed as the sum of the signals for all charge states and the energy scan of the mass spectra is provided.

2.
Eur J Mass Spectrom (Chichester) ; 23(4): 230-236, 2017 08.
Article in English | MEDLINE | ID: mdl-29028398

ABSTRACT

This article offers a new approach to computer modeling of time-of-flight analyzers of mass spectrometers. The main feature of the model is comprehensive tracking of the processes from the laser plasma generation until the final stage, on which the isotopic or elemental composition is determined for the analyzed solid sample. Apart from usual models based on SIMION-8 3D or similar software, this article proposes fundamentally new modeling stages. These stages are (1) generation and spread of laser plasma, (2) formation of the ion packages, (3) ion detection, and (4) formation and processing of the analytical signals. In order to provide consistent modeling of all the stages, special software units were developed. Program control of the analyzer ion optics (electrodes voltages) allows scan of mass spectra by ion energy. Additional complex of the programs provides simulation of mass spectra digitization, summation of digitized mass spectra for a wide range of variable parameters, and consideration of the discriminatory effects. According to the data, the software calculates ion-optical characteristics of the analyzer and the analytical parameters of measurement results.

3.
Article in English | MEDLINE | ID: mdl-26764311

ABSTRACT

Aspects of a new type of laser time-of-flight mass spectrometer are described in this letter. It is based on a wedge-shaped reflecting mirror and is used as an ion analyzer. The analyzer provides time focusing by both energy and a divergence angle of ions. Time focusing of good quality is acquired in the energy range of ±20% of the average ion energy, which is, at least, two times wider than the energy range of the known ion optical systems for similar applications. The mass resolution of the analyzer is ~600, while overall dimensions are very small (10 × 10 × 5 cm).

4.
Eur J Mass Spectrom (Chichester) ; 20(2): 185-92, 2014.
Article in English | MEDLINE | ID: mdl-24895779

ABSTRACT

Characteristic ion mobility mass spectrometry data, reduced mobility, and limits of detection (signal-to-noise ratio = 3) were determined for six synthetic drugs and cocaine by ion mobility time-of-flight mass spectrometry (IM-TOF-MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). The studied synthetic illicit drugs recently appeared on the recreational drug market as designer drugs and were methylone, 4-MEC (4'-methylethcathinone), 3,4-MDPV (3,4-methylenedioxypyrovalerone), JWH-210 [4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone], JWH-250 [2-(2-methoxyphenyl)-1-(1-pentyl-1H-indol-3-yl)ethanone], and JWH-203 [1-pentyl-3-(2'-chlorophenylacetyl) indole]. Absolute reduced mobilities in nitrogen were 1.35, 1.28, 1.41, 1.30, 1.18, 0.98, 1.09, and 1.07 cm2V(-1)s(-1), for methylone [M-H]+, methylone [M+H]+, 4-MEC [M-H]+, 4-MEC [M+H]+, 3,4-MDPV [M+H]+, JWH-210 [M+H]+, JWH-250 [M+H]+, and JWH-203 [M+H]+, respectively. Selected illicit drugs are easily identified by IM-TOF-MS during a 100s analysis. Relative Limits of detection ranged from 4 to 400 nM are demonstrated for these compounds. Such relative limits of detection correspond to 14 pg to 2 ng absolute limits of detection. Better detection limits are obtained in APCI mode for all the illicit drugs except cocaine. ESI mode was found to be preferable for the IM-TOF-MS detection of cocaine at trace levels. A single sample analysis is completed in an order of magnitude less time than that for conventional liquid chromatography/mass spectrometry approach. The application allows one to consider IM-TOF-MS as a good candidate for a method to determine quickly the recently surfaced designer drugs marketed on the internet as "bath salts," "spice," and "herbal blends".


Subject(s)
Designer Drugs/analysis , Designer Drugs/chemistry , Illicit Drugs/analysis , Illicit Drugs/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Substance Abuse Detection/methods
5.
Anal Chem ; 85(19): 9003-12, 2013 Oct 01.
Article in English | MEDLINE | ID: mdl-23968331

ABSTRACT

Recently developed ion mobility mass spectrometer is described. The instrument is based on a drift tube ion mobility spectrometer and an orthogonal acceleration electrostatic sector time-of-flight mass analyzer. Data collection is performed using a specially developed fast ADC-based recorder that allows real-time data integration in an interval between 3 and 100 s. Primary tests were done with positive ion electrospray. The tests have shown obtaining 100 ion mobility resolving power and 2000 mass resolving power. Obtained for 2,6-di-tert-butylpyridine in electrosprayed liquid samples during 100 s analysis and full IMS/MS data collection mode were 4 nM relative limits of detection and a 1 pg absolute limit of detection (S/N=3). Characteristic ion mobility/mass distributions were recorded for selected antibiotics, including amoxicillin, ampicillin, lomefloxacin, and ofloxacin. At studied conditions, lomefloxacin forms only a protonated molecule-producing reduced ion mobility peak at 1.082 cm(2)/(V s). Both amoxicillin and ampicillin produce [M + H](+), [M + CH3OH + H](+), and [M + CH3CN + H](+). Amoxicillin shows two peaks at 0.909 cm(2)/(V s) and 0.905 cm(2)/(V s). Ampicillin shows one peak at 0.945 cm(2)/(V s). Intensity of protonated methanol containing cluster for both ampicillin and amoxicillin has a clear tendency to rise with sample keeping time. Ofloxacin produces two peaks in the ion mobility distribution. A lower ion mobility peak at 1.051 cm(2)/(V s) is shown to be formed by [M + H](+) ions. A higher ion mobility peak appearing for samples kept more than 48 h is shown to be formed by both [M + H](+) ion and a component identified as the [M + 2H + M](+2) cluster. The cluster probably partly dissociates in the interface producing the [M + H](+) ion.

6.
Int J Syst Evol Microbiol ; 52(Pt 6): 1917-1923, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12508848

ABSTRACT

Two novel species, Rathayibacter caricis sp. nov. (type strain VKM Ac-1799T = UCM Ac-618T) and Rathayibacter festucae sp. nov. (type strain VKM Ac-1390T UCM Ac-619T), are proposed for two coryneform actinomycetes found in the phyllosphere of Carex sp. and in the leaf gall induced by the plant-parasitic nematode Anguina graminis on Festuca rubra L., respectively. The strains of the novel species are typical of the genus Rathayibacter in their chemotaxonomic characteristics and fall into the Rathayibacter 16S rDNA phylogenetic cluster. They belong to two separate genomic species and differ markedly from current validly described species of Rathayibacter at the phenotypic level. The most striking feature differentiating Rathayibacter caricis sp. nov. from other species of the genus is the presence of fucose in its cell wall and Rathayibacter festucae sp. nov. can be easily recognized among other yellow-pigmented rathayibacters because of its rose-orange-coloured colonies.


Subject(s)
Actinomycetales/classification , Actinomycetales/isolation & purification , Carex Plant/microbiology , Festuca/microbiology , Actinomycetales/genetics , Actinomycetales/pathogenicity , Animals , Base Composition , DNA, Bacterial/chemistry , DNA, Bacterial/genetics , DNA, Ribosomal/genetics , Festuca/parasitology , Genes, Bacterial , Molecular Sequence Data , Phenotype , Phylogeny , Pigmentation , RNA, Bacterial/genetics , RNA, Ribosomal, 16S/genetics , Tylenchoidea/pathogenicity
SELECTION OF CITATIONS