Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Eur J Orthop Surg Traumatol ; 34(2): 959-965, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37779131

ABSTRACT

PURPOSE: To analyze differences in union, complication rates and cost from surgical fixation of distal fibula fractures with fibular plating implants. METHODS: In total, 380 adult patients from 2012 to 2015 treated with 12 fibular plates from 4 different manufacturers utilized by 9 surgeons were retrospectively reviewed. They were stratified into a conventional one-third tubular fibular plate group, pre-contoured anatomic locking plate group, or a heterogeneous group including 3.5-mm reconstruction, one-third tubular locking, composite, and limited compression plates. The outcomes included failure of fixation, deep infection requiring debridement, time to union, anatomic reduction, superficial infection, hardware removal, and post-traumatic arthritis. Plate and screw costs were calculated from hospital billing records. RESULTS: Pre-contoured locking plates were used in older, female patients with a greater number of comorbidities. Open injuries and OTA 44B fractures were more likely to be an indication for pre-contoured plates. There was no difference noted in time to union between the different plating groups. Risk factors for deep infection requiring debridement included a history of tobacco use, open fractures, and pre-contoured locking plates relative to the conventional plating group. The pre-contoured plating group was on average $586 more expensive compared to the conventional group. CONCLUSION: Pre-contoured locking plates achieved similar radiographic outcomes compared to conventional plates with an increased risk of complications and higher cost. Surgeons should consider their choice of implant based on the patient's fracture pattern, underlying comorbidities, and risk for infection.


Subject(s)
Ankle Fractures , Adult , Humans , Female , Aged , Ankle Fractures/surgery , Ankle Fractures/etiology , Fibula/injuries , Retrospective Studies , Fracture Fixation, Internal/adverse effects , Costs and Cost Analysis , Bone Plates/adverse effects , Treatment Outcome
2.
South Med J ; 114(12): 789-796, 2021 12.
Article in English | MEDLINE | ID: mdl-34853856

ABSTRACT

OBJECTIVES: Reports of medical student mentorship prevalence range between 26% and 77%. This broad range likely reflects the tendencies of studies to focus on specific populations of medical students. There is little consensus about the characteristics of mentoring relationships among medical students. The primary goal of this study was to determine the reported prevalence of mentorship among medical students in the United States. The secondary goals were to assess the desired qualities of and barriers to successful mentoring from a medical student perspective. METHODS: A cross-sectional online survey was administered via Qualtrics to all medical students at participating accredited medical schools from July 2018 to March 2019. The questionnaire contained a subsection of questions that assessed the existence of mentoring, facilitators, and barriers in finding a mentor, and the desired qualities of a successful mentor. RESULTS: With a 94% completion rate, 369 (69%) of 532 medical students reported having a mentor. Adjusted analysis showed that fourth-year medical students were significantly more likely to have a mentor compared with first-year (odds ratio [OR] 2.65, 95% confidence interval [CI] 1.49-4.73, P = 0.001), second-year (OR 2.07, 95% CI 1.14-3.76, P = 0.016), and third-year medical students (OR 2.16, 95% CI 1.2-3.90, P = 0.011). Compassion (64%) was the most commonly reported quality in a successful mentoring relationship. Lack of time from mentor (75%) was the most commonly reported barrier. CONCLUSIONS: This study may serve as a guide to fostering more supportive mentoring relationships. Each mentoring relationship should be tailored to the needs of the mentee, however.


Subject(s)
Mentoring/standards , Students, Medical/psychology , Adult , Cross-Sectional Studies , Female , Humans , Male , Mentoring/ethics , Prevalence , Surveys and Questionnaires , United States
3.
J Orthop Trauma ; 33(11): 559-563, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31464856

ABSTRACT

OBJECTIVE: To determine whether intramedullary nail (IMN) diameter, antegrade versus retrograde insertion, or the difference between the canal and IMN diameter affect femoral shaft fracture healing. DESIGN: Retrospective analysis of a prospective database. SETTING: Level One Regional Trauma Center. PATIENTS/PARTICIPANTS: Seven hundred thirty-three femoral shaft fractures (OTA/AO 32) treated with an IMN between 1999 and 2017. After exclusion criteria, 484 fractures remained in the final analysis. INTERVENTION: Closed section, cannulated, interlocked, titanium alloy IMN using a reamed insertion technique. MAIN OUTCOME MEASUREMENTS: Nonunion, IMN size (10, 11.5, and 13 mm), antegrade versus retrograde insertion, Δ canal-nail diameter (ΔD) after reaming (<1, 1-2, or >2 mm). RESULTS: IMN diameters used were as follows: 314/10 mm (64%), 137/11.5 mm (28%), and 33/13 mm (8%). Forty-five percent were placed in antegrade versus 55% retrograde. Four hundred fifty-six fractures (94.2%) healed uneventfully. There were no IMN failures. 10/484 IMNs (2%) had broken interlocking screws; only 4 were associated with a NU. Average time to union was 23 weeks (12-119). Twenty-eight (5.8%) developed NU. There was no statistical correlation between (1) the NU rate and IMN diameter: 10 mm, 6.3%; 11.5 mm, 5.1%; 13 mm, 3% (P = 0.8, power = 0.85), (2) the NU rate and ΔD: 7.1% <1 mm, 5.6% 1-2 mm, 20% >2 mm (P = 0.36), (3) the NU rate and fracture location: Prox = 11%, Mid = 5%, Dist = 3% (P = 0.13), or (4) the NU rate and antegrade (7.2%) versus retrograde (4.2%) insertion (P = 0.24). CONCLUSION: Similar healing rates occurred regardless of IMN diameter, Δ canal-nail diameter after reaming, or insertion site. This indicates that a closed section, cannulated, interlocked, titanium alloy IMN with a diameter of 10 mm can be considered the standard diameter for the treatment of acute femoral shaft fractures, regardless of entry point. This should be associated with less reaming and therefore shorter operative times, and possibly less hospital implant inventories as well. Larger diameter IMN should be reserved for revision surgery. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Bone Nails , Femoral Fractures/surgery , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Fractures, Ununited/surgery , Adult , Aged , Aged, 80 and over , Databases, Factual , Equipment Design , Female , Femoral Fractures/diagnostic imaging , Florida , Follow-Up Studies , Fracture Healing/physiology , Fractures, Ununited/diagnostic imaging , Humans , Injury Severity Score , Male , Middle Aged , Prospective Studies , Reoperation/methods , Retrospective Studies , Risk Assessment , Statistics, Nonparametric , Trauma Centers
4.
Neuron ; 92(2): 493-504, 2016 Oct 19.
Article in English | MEDLINE | ID: mdl-27720487

ABSTRACT

Stress is a well-known risk factor for subsequent alcohol abuse, but the neural mechanisms underlying interactions between stress and alcohol remain largely unknown. Addictive drug reinforcement and stress signaling involve common neural circuitry, including the mesolimbic dopamine system. We demonstrate in rodents that pre-exposure to stress attenuates alcohol-induced dopamine responses and increases alcohol self-administration. The blunted dopamine signaling resulted from ethanol-induced excitation of GABA neurons in the ventral tegmental area. Excitation of GABA neurons was mediated by GABAA receptor activation and involved stress-induced functional downregulation of the K+, Cl- cotransporter, KCC2. Blocking stress hormone receptors, enhancing KCC2 function, or preventing excitatory GABA signaling by alternative methods all prevented the attenuated alcohol-induced dopamine response and prevented the increased alcohol self-administration. These results demonstrate that stress alters the neural and behavioral responses to alcohol through a neuroendocrine signal that shifts inhibitory GABA transmission toward excitation.


Subject(s)
Alcoholism/metabolism , Central Nervous System Depressants/administration & dosage , Dopamine/metabolism , Dopaminergic Neurons/metabolism , Ethanol/administration & dosage , Self Administration , Stress, Psychological/metabolism , Ventral Tegmental Area/metabolism , gamma-Aminobutyric Acid/metabolism , Acetazolamide/pharmacology , Alcoholism/psychology , Animals , Carbonic Anhydrase Inhibitors/pharmacology , Conditioning, Operant , Hormone Antagonists/pharmacology , Male , Microdialysis , Mifepristone/pharmacology , Patch-Clamp Techniques , Rats , Rats, Long-Evans , Receptors, GABA-A/metabolism , Symporters/drug effects , Symporters/metabolism , K Cl- Cotransporters
SELECTION OF CITATIONS