Phys Med Biol ; 62(22): 8634-8654, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28858855

ABSTRACT

In order to describe the volume recombination in a pulsed radiation field of high dose-per-pulse this study presents a numerical solution of a 1D transport model of the liberated charges in a plane-parallel ionization chamber. In addition, measurements were performed on an Advanced Markus ionization chamber in a pulsed electron beam to obtain suitable data to test the calculation. The experiment used radiation pulses of 4 µs duration and variable dose-per-pulse values up to about 1 Gy, as well as pulses of variable duration up to 308 [Formula: see text] at constant dose-per-pulse values between 85 mGy and 400 mGy. Those experimental data were compared to the developed numerical model and existing descriptions of volume recombination. At low collection voltages the observed dose-per-pulse dependence of volume recombination can be approximated by the existing theory using effective parameters. However, at high collection voltages large discrepancies are observed. The developed numerical model shows much better agreement with the observations and is able to replicate the observed behavior over the entire range of dose-per-pulse values and collection voltages. Using the developed numerical model, the differences between observation and existing theory are shown to be the result of a large fraction of the charge being collected as free electrons and the resultant distortion of the electric field inside the chamber. Furthermore, the numerical solution is able to calculate recombination losses for arbitrary pulse durations in good agreement with the experimental data, an aspect not covered by current theory. Overall, the presented numerical solution of the charge transport model should provide a more flexible tool to describe volume recombination for high dose-per-pulse values as well as for arbitrary pulse durations and repetition rates.


Subject(s)
Electrons , Models, Theoretical , Radiometry/instrumentation , Radiometry/methods , Radiation Dosage
2.
Phys Med Biol ; 62(13): 5531-5555, 2017 Jul 07.
Article in English | MEDLINE | ID: mdl-28609301

ABSTRACT

Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.


Subject(s)
Lasers , Particle Accelerators , Proton Therapy/instrumentation , Humans , Models, Theoretical , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
3.
Rev Sci Instrum ; 87(8): 083310, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27587116

ABSTRACT

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

4.
J Radiol Prot ; 35(2): 415-28, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25978117

ABSTRACT

Pulsed radiation fields, characterized by microsecond pulse duration and correspondingly high pulse dose rates, are increasingly used in therapeutic, diagnostic and research applications. Yet, dose rate meters which are used to monitor radiation protection areas or to inspect radiation shielding are mostly designed, characterized and tested for continuous fields and show severe deficiencies in highly pulsed fields. Despite general awareness of the problem, knowledge of the specific limitations of individual instruments is very limited, complicating reliable measurements. We present here the results of testing three commercial dose rate meters, the RamION ionization chamber, the LB 1236-H proportional counter and the 6150AD-b scintillation counter, for their response in pulsed radiation fields of varied pulse dose and duration. Of these three the RamION proved reliable, operating in a pulsed radiation field within its specifications, while the other two instruments were only able to measure very limited pulse doses and pulse dose rates reliably.


Subject(s)
Particle Accelerators/instrumentation , Radiation Protection/instrumentation , Radiometry/instrumentation , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Radiation Dosage
5.
Med Phys ; 39(5): 2447-55, 2012 May.
Article in English | MEDLINE | ID: mdl-22559615

ABSTRACT

PURPOSE: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10(11) Gy∕s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. METHODS: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. RESULTS: The dosimeters are dose rate independent up to 4●10(9) Gy∕s within 2% (OSL and TLD) and up to 15●10(9) Gy∕s within 5% (EBT films). The diamond detectors show strong dose rate dependence. CONCLUSIONS: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.


Subject(s)
Diamond , Film Dosimetry/methods , Thermoluminescent Dosimetry/methods
6.
Rev Sci Instrum ; 83(12): 123301, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23277976

ABSTRACT

In recent years, a new generation of high repetition rate (~10 Hz), high power (~100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ~1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

7.
Phys Med Biol ; 56(6): 1529-43, 2011 Mar 21.
Article in English | MEDLINE | ID: mdl-21325708

ABSTRACT

An integrated dosimetry and cell irradiation system (IDOCIS) with laser-accelerated proton beams was developed, characterized, calibrated and successfully used for systematic in vitro experiments. Due to the broad exponentially shaped energy spectrum, the low-energy range of the protons (<20 MeV) and the high pulse dose, the absolute dosimetry for this beam quality is challenging. Therefore, a dedicated Faraday cup is used as an energy and dose rate independent absolute dosimeter that has been calibrated consistently with three independent methods. A transmission ionization chamber providing online relative dose information is cross-calibrated against the Faraday cup. Providing both online and absolute dose information, the IDOCIS allows for quantitative dosimetric and radiobiological studies at current low-energy laser-accelerated proton beams. Finally, first dosimetric characterizations of a laser-accelerated proton beam with the IDOCIS are presented.


Subject(s)
Cells/radiation effects , Lasers , Radiometry/instrumentation , Radiotherapy, High-Energy/instrumentation , Calibration , Humans , Protons , Radiometry/methods , Radiotherapy Dosage , Radiotherapy, High-Energy/methods
8.
Med Phys ; 37(4): 1392-400, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20443460

ABSTRACT

PURPOSE: In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intensities and a controlled delivery of prescribed doses at the treatment site. Although conventional and laser-based particle accelerators will administer the same dose to the patient, their different time structures could result in different radiobiological properties. Therefore, the biological response to the ultrashort pulse durations and the resulting high peak dose rates of these particle beams have to be investigated. The technical prerequisites, i.e., a suitable cell irradiation setup and the precise dosimetric characterization of a laser-based particle accelerator, have to be realized in order to prepare systematic cell irradiation experiments. METHODS: The Jena titanium:sapphire laser system (JETI) was customized in preparation for cell irradiation experiments with laser-accelerated electrons. The delivered electron beam was optimized with regard to its spectrum, diameter, dose rate, and dose homogeneity. A custom-designed beam and dose monitoring system, consisting of a Roos ionization chamber, a Faraday cup, and EBT-1 dosimetry films, enables real-time monitoring of irradiation experiments and precise determination of the dose delivered to the cells. Finally, as proof-of-principle experiment cell samples were irradiated using this setup. RESULTS: Laser-accelerated electron beams, appropriate for in vitro radiobiological experiments, were generated with a laser shot frequency of 2.5 Hz and a pulse length of 80 fs. After laser acceleration in the helium gas jet, the electrons were filtered by a magnet, released from the vacuum target chamber, and propagated in air for a distance of 220 mm. Within this distance a lead collimator (aperture of 35 mm) was introduced, leading, along with the optimized setup, to a beam diameter of 35 mm, sufficient for the irradiation of common cell culture vessels. The corresponding maximum dose inhomogeneity over the beam spot was less than 10% for all irradiated samples. At cell position, the electrons posses a mean kinetic energy of 13.6 MeV, a bunch length of about 5 ps (FWHM), and a mean pulse dose of 1.6 mGy/bunch. Cross correlations show clear linear dependencies for the online recorded accumulated bunch charges, pulse doses, and pulse numbers on absolute doses determined with EBT-1 films. Hence, the established monitoring system is suitable for beam control and a dedicated dose delivery. Additionally, reasonable day-to-day stable and reproducible properties of the electron beam were achieved. CONCLUSIONS: Basic technical prerequisites for future cell irradiation experiments with ultrashort pulsed laser-accelerated electrons were established at the JETI laser system. The implemented online control system is suitable to compensate beam intensity fluctuations and the achieved accuracy of dose delivery to the cells is sufficient for radiobiological cell experiments. Hence, systematic in vitro cell irradiation experiments can be performed, being the first step toward clinical application of laser-accelerated particles. Further steps, including the transfer of the established methods to experiments on higher biological systems or to other laser-based particle accelerators, will be prepared.


Subject(s)
Radiometry/methods , Radiotherapy/standards , Aluminum Oxide/chemistry , Animals , Electrons , Equipment Design , Humans , Lasers , Particle Accelerators , Radiotherapy/methods , Radiotherapy Dosage , Reproducibility of Results , Titanium/chemistry
9.
Rev Sci Instrum ; 81(1): 013307, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20113093

ABSTRACT

The characterization of the absolute number of electrons generated by laser wakefield acceleration often relies on absolutely calibrated FUJI imaging plates (IP), although their validity in the regime of extreme peak currents is untested. Here, we present an extensive study on the dependence of the sensitivity of BAS-SR and BAS-MS IP to picosecond electron bunches of varying charge of up to 60 pC, performed at the electron accelerator ELBE, making use of about three orders of magnitude of higher peak intensity than in prior studies. We demonstrate that the response of the IPs shows no saturation effect and that the BAS-SR IP sensitivity of 0.0081 photostimulated luminescence per electron number confirms surprisingly well data from previous works. However, the use of the identical readout system and handling procedures turned out to be crucial and, if unnoticed, may be an important error source.


Subject(s)
Electrons , X-Ray Film , Calibration , Linear Models , Luminescence , Particle Accelerators , Time Factors , X-Rays