Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
Add more filters










Publication year range
1.
Microsc Microanal ; 29(Supplement_1): 1064-1065, 2023 Jul 22.
Article in English | MEDLINE | ID: mdl-37613229
2.
Science ; 380(6651): 1270-1275, 2023 06 23.
Article in English | MEDLINE | ID: mdl-37347862

ABSTRACT

The development of voltage-sensitive fluorescent probes suggests fluorescence lifetime as a promising readout for electrical activity in biological systems. Existing approaches fail to achieve the speed and sensitivity required for voltage imaging in neuroscience applications. We demonstrated that wide-field electro-optic fluorescence lifetime imaging microscopy (EO-FLIM) allows lifetime imaging at kilohertz frame-acquisition rates, spatially resolving action potential propagation and subthreshold neural activity in live adult Drosophila. Lifetime resolutions of <5 picoseconds at 1 kilohertz were achieved for single-cell voltage recordings. Lifetime readout is limited by photon shot noise, and the method provides strong rejection of motion artifacts and technical noise sources. Recordings revealed local transmembrane depolarizations, two types of spikes with distinct fluorescence lifetimes, and phase locking of spikes to an external mechanical stimulus.


Subject(s)
Action Potentials , Neurons , Optical Imaging , Fluorescent Dyes , Microscopy, Fluorescence/methods , Neurons/physiology , Optical Imaging/methods , Animals , Drosophila melanogaster
3.
Nature ; 612(7941): 661-665, 2022 12.
Article in English | MEDLINE | ID: mdl-36418400

ABSTRACT

Quantum sensors are used for precision timekeeping, field sensing and quantum communication1-3. Comparisons among a distributed network of these sensors are capable of, for example, synchronizing clocks at different locations4-8. The performance of a sensor network is limited by technical challenges as well as the inherent noise associated with the quantum states used to realize the network9. For networks with only spatially localized entanglement at each node, the noise performance of the network improves at best with the square root of the number of nodes10. Here we demonstrate that spatially distributed entanglement between network nodes offers better scaling with network size. A shared quantum nondemolition measurement entangles a clock network with up to four nodes. This network provides up to 4.5 decibels better precision than one without spatially distributed entanglement, and 11.6 decibels improvement as compared to a network of sensors operating at the quantum projection noise limit. We demonstrate the generality of the approach with atomic clock and atomic interferometer protocols, in scientific and technologically relevant configurations optimized for intrinsically differential comparisons of sensor outputs.

4.
Science ; 375(6577): 226-229, 2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35025635

ABSTRACT

Gravity curves space and time. This can lead to proper time differences between freely falling, nonlocal trajectories. A spatial superposition of a massive particle is predicted to be sensitive to this effect. We measure the gravitational phase shift induced in a matter-wave interferometer by a kilogram-scale source mass close to one of the wave packets. Deflections of each interferometer arm due to the source mass are independently measured. The phase shift deviates from the deflection-induced phase contribution, as predicted by quantum mechanics. In addition, the observed scaling of the phase shift is consistent with Heisenberg's error-disturbance relation. These results show that gravity creates Aharonov-Bohm phase shifts analogous to those produced by electromagnetic interactions.

5.
ACS Nano ; 15(10): 16043-16054, 2021 10 26.
Article in English | MEDLINE | ID: mdl-34546704

ABSTRACT

We demonstrate an electro-optic wide-field method to enable fluorescence lifetime microscopy (FLIM) with high throughput and single-molecule sensitivity. Resonantly driven Pockels cells are used to efficiently gate images at 39 MHz, allowing fluorescence lifetime to be captured on standard camera sensors. Lifetime imaging of single molecules is enabled in wide field with exposure times of less than 100 ms. This capability allows combination of wide-field FLIM with single-molecule super-resolution localization microscopy. Fast single-molecule dynamics such as FRET and molecular binding events are captured from wide-field images without prior spatial knowledge. A lifetime sensitivity of 1.9 times the photon shot-noise limit is achieved, and high throughput is shown by acquiring wide-field FLIM images with millisecond exposure and >108 photons per frame. Resonant electro-optic FLIM allows lifetime contrast in any wide-field microscopy method.


Subject(s)
Photons , Single Molecule Imaging , Fluorescence Resonance Energy Transfer , Microscopy, Fluorescence
6.
Rev Sci Instrum ; 92(4): 043705, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243461

ABSTRACT

We present the design and prototype of a switchable electron mirror, along with a technique for driving it with an arbitrary pulse shape. We employ a general technique for electronic pulse-shaping, where high fidelity of the pulse shape is required, but the characteristics of the system, which are possibly nonlinear, are not known. This driving technique uses an arbitrary waveform generator to pre-compensate the pulse, with a simple iterative algorithm used to generate the input waveform. This is a broadly applicable, general method for arbitrary pulse shaping. Driving our switchable electron mirror with a flat-top pulse, we demonstrate an improvement in rms error of roughly two orders of magnitude compared to an uncompensated waveform. Our results demonstrate the feasibility of high fidelity waveform reproduction in the presence of nonidealities, with immediate applications in the realization of novel electron optical components.

7.
Opt Lett ; 45(23): 6555-6558, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-33258860

ABSTRACT

We demonstrate a narrow-linewidth 780 nm laser system with up to 40W power and a frequency modulation bandwidth of 230 MHz. Efficient overlap on nonlinear optical elements combines two pairs of phase-locked frequency components into a single beam. Serrodyne modulation with a high-quality sawtooth waveform is used to perform frequency shifts with >96.5% efficiency over tens of megahertz. This system enables next-generation atom interferometry by delivering simultaneous, Stark-shift-compensated dual beam splitters while minimizing spontaneous emission.

8.
Phys Rev Lett ; 125(19): 191101, 2020 Nov 06.
Article in English | MEDLINE | ID: mdl-33216577

ABSTRACT

We use a dual-species atom interferometer with 2 s of free-fall time to measure the relative acceleration between ^{85}Rb and ^{87}Rb wave packets in the Earth's gravitational field. Systematic errors arising from kinematic differences between the isotopes are suppressed by calibrating the angles and frequencies of the interferometry beams. We find an Eötvös parameter of η=[1.6±1.8(stat)±3.4(syst)]×10^{-12}, consistent with zero violation of the equivalence principle. With a resolution of up to 1.4×10^{-11} g per shot, we demonstrate a sensitivity to η of 5.4×10^{-11}/sqrt[Hz].

9.
Phys Rev Lett ; 125(4): 043202, 2020 Jul 24.
Article in English | MEDLINE | ID: mdl-32794788

ABSTRACT

We demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 ^{87}Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 µm radius and falls roughly 300 µm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2)×10^{-12}, 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.

10.
Nat Commun ; 10(1): 4561, 2019 10 08.
Article in English | MEDLINE | ID: mdl-31594938

ABSTRACT

Nanosecond temporal resolution enables new methods for wide-field imaging like time-of-flight, gated detection, and fluorescence lifetime. The optical efficiency of existing approaches, however, presents challenges for low-light applications common to fluorescence microscopy and single-molecule imaging. We demonstrate the use of Pockels cells for wide-field image gating with nanosecond temporal resolution and high photon collection efficiency. Two temporal frames are obtained by combining a Pockels cell with a pair of polarizing beam-splitters. We show multi-label fluorescence lifetime imaging microscopy (FLIM), single-molecule lifetime spectroscopy, and fast single-frame FLIM at the camera frame rate with 103-105 times higher throughput than single photon counting. Finally, we demonstrate a space-to-time image multiplexer using a re-imaging optical cavity with a tilted mirror to extend the Pockels cell technique to multiple temporal frames. These methods enable nanosecond imaging with standard optical systems and sensors, opening a new temporal dimension for wide-field low-light microscopy.

11.
Ultramicroscopy ; 207: 112834, 2019 12.
Article in English | MEDLINE | ID: mdl-31520925

ABSTRACT

Multi-pass transmission electron microscopy (MPTEM) has been proposed as a way to reduce damage to radiation-sensitive materials. For the field of cryo-electron microscopy (cryo-EM), this would significantly reduce the number of projections needed to create a 3D model and would allow the imaging of lower-contrast, more heterogeneous samples. We have designed a 10 keV proof-of-concept MPTEM. The column features fast-switching gated electron mirrors which cause each electron to interrogate the sample multiple times. A linear approximation for the multi-pass contrast transfer function (CTF) is developed to explain how the resolution depends on the number of passes through the sample.

12.
Phys Rev Lett ; 120(18): 183604, 2018 May 04.
Article in English | MEDLINE | ID: mdl-29775337

ABSTRACT

In an ideal test of the equivalence principle, the test masses fall in a common inertial frame. A real experiment is affected by gravity gradients, which introduce systematic errors by coupling to initial kinematic differences between the test masses. Here we demonstrate a method that reduces the sensitivity of a dual-species atom interferometer to initial kinematics by using a frequency shift of the mirror pulse to create an effective inertial frame for both atomic species. Using this method, we suppress the gravity-gradient-induced dependence of the differential phase on initial kinematic differences by 2 orders of magnitude and precisely measure these differences. We realize a relative precision of Δg/g≈6×10^{-11} per shot, which improves on the best previous result for a dual-species atom interferometer by more than 3 orders of magnitude. By reducing gravity gradient systematic errors to one part in 10^{13}, these results pave the way for an atomic test of the equivalence principle at an accuracy comparable with state-of-the-art classical tests.

13.
Sci Rep ; 7(1): 1699, 2017 05 10.
Article in English | MEDLINE | ID: mdl-28490730

ABSTRACT

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a multi-pass measurement protocol enables imaging of single proteins, without averaging structures over multiple images. While we demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free.

14.
Phys Rev Lett ; 118(18): 183602, 2017 May 05.
Article in English | MEDLINE | ID: mdl-28524681

ABSTRACT

Spacetime curvature induces tidal forces on the wave function of a single quantum system. Using a dual light-pulse atom interferometer, we measure a phase shift associated with such tidal forces. The macroscopic spatial superposition state in each interferometer (extending over 16 cm) acts as a nonlocal probe of the spacetime manifold. Additionally, we utilize the dual atom interferometer as a gradiometer for precise gravitational measurements.

15.
Phys Rev Lett ; 118(14): 140401, 2017 Apr 07.
Article in English | MEDLINE | ID: mdl-28430469

ABSTRACT

Bell correlations, indicating nonlocality in composite quantum systems, were until recently only seen in small systems. Here, we demonstrate Bell correlations in squeezed states of 5×10^{5} ^{87}Rb atoms. The correlations are inferred using collective measurements as witnesses and are statistically significant to 124 standard deviations. The states are both generated and characterized using optical-cavity aided measurements.

16.
Opt Lett ; 41(24): 5744-5747, 2016 Dec 15.
Article in English | MEDLINE | ID: mdl-27973521

ABSTRACT

The iterative interaction of a photon with a sample can lead to increased sensitivity in measuring the properties of the samples, such as its refractive index or birefringence. Here we show that this principle can also be used to generate and sense states of light. In particular, we demonstrate a technique to generate states with high orbital angular momentum using a single-vortex phase plate (VPP). This is accomplished by placing the phase plate in a self-imaging cavity such that light interacts with it multiple times; for an ideal phase plate, this is equivalent to iterative applications of the angular momentum operator. Using a discrete VPP, we show that our setup realizes a high-dimensional generalization of the Pauli matrix σx, and that the created states show sub-diffraction limited features that might find applications in structured illumination microscopy.

17.
Nat Commun ; 7: 12858, 2016 Sep 27.
Article in English | MEDLINE | ID: mdl-27670525

ABSTRACT

Microscopy of biological specimens often requires low light levels to avoid damage. This yields images impaired by shot noise. An improved measurement accuracy at the Heisenberg limit can be achieved exploiting quantum correlations. If sample damage is the limiting resource, an equivalent limit can be reached by passing photons through a specimen multiple times sequentially. Here we use self-imaging cavities and employ a temporal post-selection scheme to present full-field multi-pass polarization and transmission micrographs with variance reductions of 4.4±0.8 dB (11.6±0.8 dB in a lossless setup) and 4.8±0.8 dB, respectively, compared with the single-pass shot-noise limit. If the accuracy is limited by the number of detected probe particles, our measurements show a variance reduction of 25.9±0.9 dB. The contrast enhancement capabilities in imaging and in diffraction studies are demonstrated with nanostructured samples and with embryonic kidney 293T cells. This approach to Heisenberg-limited microscopy does not rely on quantum state engineering.

18.
Nature ; 529(7587): 505-8, 2016 Jan 28.
Article in English | MEDLINE | ID: mdl-26751056

ABSTRACT

Quantum metrology uses quantum entanglement--correlations in the properties of microscopic systems--to improve the statistical precision of physical measurements. When measuring a signal, such as the phase shift of a light beam or an atomic state, a prominent limitation to achievable precision arises from the noise associated with the counting of uncorrelated probe particles. This noise, commonly referred to as shot noise or projection noise, gives rise to the standard quantum limit (SQL) to phase resolution. However, it can be mitigated down to the fundamental Heisenberg limit by entangling the probe particles. Despite considerable experimental progress in a variety of physical systems, a question that persists is whether these methods can achieve performance levels that compare favourably with optimized conventional (non-entangled) systems. Here we demonstrate an approach that achieves unprecedented levels of metrological improvement using half a million (87)Rb atoms in their 'clock' states. The ensemble is 20.1 ± 0.3 decibels (100-fold) spin-squeezed via an optical-cavity-based measurement. We directly resolve small microwave-induced rotations 18.5 ± 0.3 decibels (70-fold) beyond the SQL. The single-shot phase resolution of 147 microradians achieved by the apparatus is better than that achieved by the best engineered cold atom sensors despite lower atom numbers. We infer entanglement of more than 680 ± 35 particles in the atomic ensemble. Applications include atomic clocks, inertial sensors, and fundamental physics experiments such as tests of general relativity or searches for electron electric dipole moment. To this end, we demonstrate an atomic clock measurement with a quantum enhancement of 10.5 ± 0.3 decibels (11-fold), limited by the phase noise of our microwave source.

19.
Phys Rev Lett ; 114(14): 143004, 2015 Apr 10.
Article in English | MEDLINE | ID: mdl-25910118

ABSTRACT

Using a matter wave lens and a long time of flight, we cool an ensemble of ^{87}Rb atoms in two dimensions to an effective temperature of less than 50_{-30}^{+50} pK. A short pulse of red-detuned light generates an optical dipole force that collimates the ensemble. We also report a three-dimensional magnetic lens that substantially reduces the chemical potential of evaporatively cooled ensembles with a high atom number. By observing such low temperatures, we set limits on proposed modifications to quantum mechanics in the macroscopic regime. These cooling techniques yield bright, collimated sources for precision atom interferometry.

20.
Opt Lett ; 40(2): 260-3, 2015 Jan 15.
Article in English | MEDLINE | ID: mdl-25679859

ABSTRACT

Laser-triggered electron emission from sharp metal tips has been demonstrated in recent years as a high brightness, ultrafast electron source. Its possible applications range from ultrafast electron microscopy to laser-based particle accelerators to electron interferometry. The ultrafast nature of the emission process allows for the sampling of an instantaneous radio frequency (RF) voltage that has been applied to a field emitter. For proof-of-concept, we use an RF signal derived from our laser's repetition rate, mapping a 9.28 GHz signal in 22.4 fs steps with 28 mv accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL
...