Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
J Clin Med ; 13(5)2024 Feb 25.
Article in English | MEDLINE | ID: mdl-38592153

ABSTRACT

There is a debate about the best alignment strategies in total knee arthroplasty (TKA). Mechanical alignment (MA) targets in combination with necessary soft tissue releases are the gold standard for TKA in end-stage valgus osteoarthritis. Some authors propagate kinematic alignment (KA) with the aim of restoring the patient's native alignment and minimizing the need for soft tissue releases. Our previous studies showed that MA with standardized soft tissue release produces reproducible results, and that the preoperative phenotype does not influence the results of patients with valgus osteoarthritis. These data suggest that there is no functional advantage to preserving valgus alignment in patients with valgus osteoarthritis. Many patients with valgus osteoarthritis present with a compromised medial collateral ligament and leaving the knee in valgus could increase the risk of secondary instability. The current literature supports MA TKA with soft tissue release as the gold standard. While using more sophisticated enabling technologies like robotic surgery might allow for aiming for very slight (1-2°) valgus alignment on the femoral side, any valgus alignment outside this range should be avoided. This review paper summarizes our current knowledge on the surgical techniques of TKA in patients with valgus osteoarthritis.

2.
Medicina (Kaunas) ; 59(10)2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37893570

ABSTRACT

Background and Objectives: There is an ongoing discussion about the best alignment targets in total knee arthroplasty (TKA). Mechanical alignment has been the standard in TKA for years. Alongside the development of various classification systems to describe the native alignment of the knee (knee phenotype), kinematic alignment restoring the individual phenotype of the knee has been advocated more recently. Alignment in TKA becomes even more challenging in knees with preoperative deformities such as valgus osteoarthritis. Materials and Methods: The study retrospectively evaluated 158 knees in 135 patients who underwent TKA with a mechanical alignment target for valgus osteoarthritis. Pre- and postoperative hip knee angle, lateral distal femur angle, and medial proximal tibial angle/tibial plate angle (pre-/postoperative) were measured on standing hip-to-ankle radiographs. Knees were grouped according to the coronal plane alignment of the knee (CPAK) classification. Preoperative and postoperative range of motion and patient-related outcome measures (WOMAC, UCLA, SF-12, pain) were assessed. Results: There was no difference in outcome for mechanically aligned TKA between the different CPAK phenotypes, suggesting that mechanical alignment is an appropriate target for the different phenotypes analyzed in the study. Remaining valgus alignment was associated with decreased postoperative UCLA scores and decreased improvement in SF-12 scores (p = 0.011/p = 0.028). Within CPAK III, mechanical aligned TKA showed better postoperative UCLA Scores than TKA with valgus alignment (p = 0.015). The individual knee phenotype in patients with valgus osteoarthritis did not influence the outcome of mechanical aligned TKA operated with standardized soft-tissue release.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Osteoarthritis , Humans , Arthroplasty, Replacement, Knee/adverse effects , Retrospective Studies , Knee Joint/surgery , Tibia/surgery , Osteoarthritis, Knee/surgery
3.
Arch Orthop Trauma Surg ; 143(3): 1217-1221, 2023 Mar.
Article in English | MEDLINE | ID: mdl-34724103

ABSTRACT

INTRODUCTION: Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery. MATERIAL AND METHODS: Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years. RESULTS: Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 µg/l and 5.0 µg/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 µg/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period. CONCLUSION: The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Male , Humans , Female , Middle Aged , Cobalt , Chromium , Prosthesis Design , Metals , Ions , Reoperation , Follow-Up Studies
4.
Int Orthop ; 46(10): 2257-2264, 2022 10.
Article in English | MEDLINE | ID: mdl-35844015

ABSTRACT

PURPOSE: The proximal chevron osteotomy and the modified Lapidus arthrodesis are both procedures utilized for deformity correction in patients with severe symptomatic hallux valgus. The aim of the current study was to compare their biomechanical stability when using locking plate fixation. METHODS: Twelve matched pairs of human anatomical lower leg specimens underwent on one side a proximal chevron osteotomy with a medial locking plate and on the other side a modified Lapidus arthrodesis with a plantar locking plate utilizing an interfragmentary compression screw. All specimens underwent bone mineral density (BMD) assessment and were tested in a servohydraulic load frame which applied a load on the centre of the metatarsal head over 1000 loading cycles with subsequently ultimate load testing. Displacement of the proximal and distal bone segment, ultimate load, and bending stiffness were analyzed. RESULTS: Mean displacement of both procedures showed no statistically significant difference throughout all the loading cycles (0.213 ≤ p ≤ 0.834). The mean ultimate load of the proximal chevron osteotomy was 227.9 N (± 232.4) and of the modified Lapidus arthrodesis 162.9 N (± 74.6) (p = 0.754). The proximal chevron osteotomy (38.2 N/mm (± 24.9)) had a significantly higher bending stiffness compared to the modified Lapidus arthrodesis (17.3 N/mm (± 9.9)) (p = 0.009). There was no correlation between BMD and displacement in all loading cycles, ultimate load, and bending stiffness of either procedure (p > 0.05). CONCLUSION: Although the bending stiffness of the chevron osteotomy was higher, there was no statistically significant difference between the surgical techniques in mean displacement and ultimate load. The BMD did not influence the overall stability of either reconstruction. Locking plate fixation increases the clinical value of the modified Lapidus arthrodesis by outweighing most of the biomechanical disadvantages in comparison to the proximal chevron osteotomy.


Subject(s)
Hallux Valgus , Metatarsal Bones , Arthrodesis/adverse effects , Arthrodesis/methods , Bone Plates , Hallux Valgus/surgery , Humans , Metatarsal Bones/surgery , Osteotomy/adverse effects , Osteotomy/methods
5.
Arch Orthop Trauma Surg ; 141(8): 1385-1391, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33515324

ABSTRACT

INTRODUCTION: Advanced valgus osteoarthritis (OA) is one of the most challenging indications for total knee arthroplasty (TKA). There is no information in the literature about the optimal timing of surgery. The current study investigates the impact of the preoperative deformity and degree of arthritis on postoperative outcome after TKA. MATERIAL AND METHODS: The study evaluated 133 knees in 107 patients with valgus OA that failed nonoperative treatment with a minimum 2-year follow-up. Mechanical alignment, Kellgren and Lawrence (K/L) score, and minimal joint space width (minJSW) were measured on AP- and hip-to-ankle radiographs. All knees had advanced OA (i.e., K/L grades 3 or 4 and less than 50% minJSW). Pre- and postoperative WOMAC, VR-12, UCLA, VAS, ROM were recorded. RESULTS: There was no difference in clinical outcome (WOMAC, UCLA, VR-12, VAS or ROM) between patients with different degrees of valgus deformities (< 5.0 deg., 5.0-9.9 deg., 10.0-14.9 deg., ≥ 15.0 deg.). There was also no correlation between K/L score or minimal joint space width and any of the outcome parameters. CONCLUSIONS: The degree of valgus deformity and the grade of osteoarthritis do not predict the outcome of TKA in patients with valgus OA. Since the risk of complication and the need for implant constraint increases with increasing deformity and instability of the knee, surgery appears to be justified in patients with advanced OA that failed nonoperative treatment, regardless of the degree of deformity.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Ankle Joint , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Radiography
6.
Wien Klin Wochenschr ; 133(1-2): 14-20, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33296025

ABSTRACT

BACKGROUND: The aim of the study was to assess (1) sports activity, (2) sports involving the upper extremities, (3) functional outcome and (4) sports-related complications of long-term survivors of primary malignant bone tumors of the proximal humerus. METHODS: A total of 18 patients with an endoprosthetic reconstruction for primary malignant bone sarcoma of the proximal humerus (8 male, 10 female, mean age 19.9 ± 8.4 years, range 7.8-37.4 years) with an average follow-up of 18.1 ± 7.4 years (range 6.7-29.8 years) were included. The type of sport, frequency, duration of each sport session and the University of California, Los Angeles (UCLA) activity score were assessed before surgery, at 1 year, 3 years and at the latest follow-up. Functional outcome was assessed by the Toronto extremity salvage score (TESS). RESULTS: The mean UCLA activity score decreased from 8.0 (±1.3, range 5-9) preoperative to 4.2 (±1.7, range 3-8) at 1­year follow-up (p < 0.05). After 3 years it increased to 5.1 (±1.75, range 3-8) and further to 7 (±1.8, range 4-9) at the last follow-up. The mean postoperative TESS was 80.8 (±6.4, range 75.7-91.4) at the latest follow-up. Patients who were initially more active without reconstruction including a synthetic mesh were more likely to develop soft tissue complications accompanied by proximal endoprothesis migration. CONCLUSION: Patients with a modular endoprosthetic reconstruction of the humerus following primary bone sarcoma resume participation in sports. Regarding the low incidence of periprosthetic infections, utilization of a synthetic mesh for reconstruction to prevent soft tissue complications in active patients should be considered.


Subject(s)
Bone Neoplasms , Plastic Surgery Procedures , Sarcoma , Adolescent , Adult , Bone Neoplasms/surgery , Child , Female , Humans , Humerus/diagnostic imaging , Humerus/surgery , Limb Salvage , Male , Retrospective Studies , Sarcoma/surgery , Survivors , Treatment Outcome , Young Adult
7.
Bone Joint J ; 102-B(4): 426-433, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32228087

ABSTRACT

AIMS: To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. METHODS: In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used. RESULTS: Overall mean ROM in stiff knees increased preoperatively from 67° (0° to 80°) to 114° postoperatively (65° to 135°) (p < 0.001). Mean knee flexion improved from 82° (0° to 110°) to 115° (65° to 135°) and mean flexion contracture decreased from 14° (0° to 50°) to 1° (0° to 10°) (p < 0.001). The mean Knee Society Score (KSS) improved from 34 (0 to 71) to 88 (38 to 100) (p < 0.001) and the KSS Functional Score from 43 (0 to 70) to 86 (0 to 100). Seven knees (7%) required manipulations under anaesthesia (MUA) and none of the knees had flexion instability. The mean overall ROM in the control group improved from 117° (100° to 140°) to 123° (100° to 130°) (p < 0.001). Mean knee flexion improved from 119° (100° to 140°) to 123° (100° to 130°) (p < 0.001) and mean flexion contracture decreased from 2° (0° to 15°) to 0° (0° to 5°) (p < 0.001). None of the knees in the control group had flexion instability or required MUA. The mean KSS Knee Score improved from 48 (0 to 80) to 94 (79 to 100) (p < 0.001) and the KSS Functional Score from 52 (5 to 100) to 95 (60 to 100) (p < 0.001). Mean improvement in ROM (p < 0.001) and KSS Knee Score (p = 0.017) were greater in knees with preoperative stiffness compared with the control group, but the KSS Functional Score improvement was comparable (p = 0.885). CONCLUSION: TKA with a 2 mm increased flexion gap provided a significant improvement of ROM in knees with preoperative stiffness. While the improvement in ROM was greater, the absolute postoperative ROM was less than in matched non-stiff knees. PS TKA with patellar resurfacing and a 2 mm increased flexion gap, in combination with adequate soft tissue balancing, provides excellent ROM and knee function when stiffness of the knee had been present preoperatively. Cite this article: Bone Joint J 2020;102-B(4):426-433.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/physiopathology , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Adult , Aged , Aged, 80 and over , Arthritis, Rheumatoid/diagnostic imaging , Arthritis, Rheumatoid/physiopathology , Arthritis, Rheumatoid/surgery , Case-Control Studies , Female , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/physiopathology , Patella/surgery , Preoperative Period , Radiography , Retrospective Studies , Severity of Illness Index , Treatment Outcome
8.
J Orthop Res ; 38(4): 911-917, 2020 04.
Article in English | MEDLINE | ID: mdl-31743452

ABSTRACT

Implant choice is a matter of concern in athletes and active patients who sustain a Jones fracture because they are prone to failure including non-union, screw failure, and refracture. The aim of this study was to compare the biomechanical behavior of a Jones fracture-specific screw (JFXS) with a cannulated headless compression screw (HCS) in a simulated partial weight-bearing and ultimate load Jones fracture fixation model. Ten matched pairs of human anatomical specimens underwent Jones fracture creation and consecutive intramedullary stabilization with a solid JFXS or a cannulated HCS. The bone mineral density was assessed prior to testing. Cyclic plantar to dorsal loading was applied for 1000 cycles, followed by load to failure testing. Angulation was measured by an opto-electronic motion capture system and mode of failure classification was determined by video analysis. Paired analysis showed no statistically significant difference between both screw constructs. Ultimate load reached 236.9 ± 107.8 N in the JFXS group compared with 210.8 ± 150.7 N in the HCS group (p = 0.429). The bone mineral density correlated positive with the pooled ultimate load (R = 0.580, p = 0.007) for all constructs and negatively with angulation (R = -0.680, p = 0.002) throughout cyclic loading. Solid fracture-specific and cannulated headless compression screws provide equal ultimate loads and stiffness for Jones fracture fixation. A low bone mineral density significantly impairs the construct stability and the ultimate load of both intramedullary screw constructs. © 2019 The Authors. Journal of Orthopaedic Research ® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society J Orthop Res 38:911-917, 2020.


Subject(s)
Fracture Fixation, Intramedullary/instrumentation , Fractures, Bone/surgery , Metatarsal Bones/injuries , Aged , Aged, 80 and over , Bone Screws , Female , Humans , Male , Metatarsal Bones/surgery , Middle Aged , Weight-Bearing
9.
Arch Orthop Trauma Surg ; 139(11): 1511-1517, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30937525

ABSTRACT

INTRODUCTION: Malpositioning of the cup in total hip arthroplasty (THA) is associated with dislocation, early polyethylene wear, and impingement. The direct anterior approach (DAA) THA allows for intraoperative fluoroscopy imaging (IF). The current study investigates the following research hypotheses: (1) intraoperative measurements of radiographic cup inclination (RI) are reliable and reproducible. (2) A correction factor can compensate for the complex parallax effects when using IF. METHODS: In 2016, 100 consecutive hips underwent primary THA utilizing DAA and IF for cup placement. RI was measured on intraoperative fluoroscopy images and postoperative AP pelvis radiographs. RESULTS: Determination of RI on IF images is reliable and reproducible (ICC 0.851-0.950). RI measurement on IF images had a good correlation with the corresponding postoperative RI on AP pelvis radiographs (r = 0.538, p < 0.001). However, intraoperative RI measurements are on average 4.9° lower compared to postoperative measurements (SD 2.5°). CONCLUSION: Intraoperative fluoroscopy is a reliable tool to measure RI during DAA THA. The surgeon needs to apply a 5°. correction factor to the intraoperative measurements to adjust for parallax.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip/methods , Fluoroscopy/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Humans , Intraoperative Period
10.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Article in English | MEDLINE | ID: mdl-29881885

ABSTRACT

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Subject(s)
Arthroplasty, Replacement, Knee , Artifacts , Metals/chemistry , Radiographic Image Interpretation, Computer-Assisted , Titanium/chemistry , Ceramics/chemistry , Chromium Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Computer Simulation , Humans , Phantoms, Imaging , Prostheses and Implants , Reproducibility of Results , Tomography, X-Ray Computed
11.
Eur Spine J ; 27(10): 2449-2456, 2018 10.
Article in English | MEDLINE | ID: mdl-30056597

ABSTRACT

PURPOSE: The preoperative prediction of medical complications is essential to optimize perioperative management. SpineSage™ is a free of charge online calculator to predict medical complications in spine surgery. The current study utilizes it in patients undergoing spine surgery to assess whether the predicted risks would correlate with the actual complication rate in clinical practice. METHODS: A total of 273 consecutive patients who underwent spinal surgery were assessed. The risk of medical complications was predicted for each patient, and all medical complications were recorded within 30 days of surgery. Based on their predicted risk of complication, patients were divided into three risk groups (< 15, 15-30, > 30%). RESULTS: The predicted overall risk of medical complications was 14.7% and was comparable to the observed complication rate of 16.1%. The predicted risk for major medical complications (3.8%) was also similar to the observed complication rate (3.3%). Detailed analysis of the segmented risk groups suggests a close correlation between predicted and actual complication rates. Receiver operating characteristic analysis revealed an area under the curve of 0.71 (p < 0.001) for the prediction of overall medical complications and 0.85 (p < 0.001) for major complications. CONCLUSIONS: The online risk calculator predicted both overall and major medical complications. The tool can assist in preoperative planning and counseling of patients. These slides can be retrieved under Electronic Supplementary Material.


Subject(s)
Orthopedic Procedures/adverse effects , Postoperative Complications/etiology , Spine/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Comorbidity , Female , Humans , Male , Middle Aged , Online Systems , Prognosis , ROC Curve , Risk Assessment/methods , Risk Factors , Sensitivity and Specificity , Young Adult
12.
Open Orthop J ; 12: 17-23, 2018.
Article in English | MEDLINE | ID: mdl-29456776

ABSTRACT

BACKGROUND: Data on indication of Unicompartmental Knee Arthroplasty (UKA) in the Asian population are currently not available. The current paper evaluates patients undergoing knee replacement at a Chinese Orthopaedic Specialty Hospital to report the percentage of patients who meet radiographic and clinical indication criteria for UKA. METHODS: Over a one-year period 463 consecutive patients (515 knees) underwent primary knee replacement surgery. Clinical data were recorded and preoperative radiographs were assessed. Patients were classified as suitable candidates for UKA based on the degree of deformity, preoperative ROM and radiographic appearance of osteoarthritis. The different indication criteria for body weight and extend of patellofemoral osteoarthritis as reported by Kozinn and Scott as well as the Oxford Group were applied. RESULTS: 160 knees (31%) were excluded because of inflammatory and posttraumatic arthritis. 55 knees had to be excluded because of incomplete radiographs. Of the remaining 300 knees with osteoarthritis, 241 knees were excluded because of extend of deformity (n=156), decreased range of motion (n=119), advanced patellofemoral arthritis with bone loss (n=11) and AP instability (n=1). Of the remaining 63 knees, 54 knees (18%) met the modified Oxford criteria for mobile UKA and only 25 knees (8%) met the Scott and Kozinn criteria for fixed UKA. CONCLUSION: The current paper suggests that in comparison to Caucasian population, only a smaller percentage of patients at a Chinese Orthopaedic Specialty Hospital meet the indication criteria for UKA. Therefore, it might make sense to concentrate UKA surgeries in high volume centers.

13.
Int Orthop ; 42(5): 1035-1041, 2018 05.
Article in English | MEDLINE | ID: mdl-28929204

ABSTRACT

PURPOSE: Revision of failed modular metal-on-metal total hip replacement (MoM-THA) can be technically difficult. A dual mobility liner can help to salvage a well-fixed acetabular component. The present paper reports the clinical and radiographic outcome of revision of failed Birmingham modular MoM-THA using a dual mobility liner. METHODS: The present study reports on ten patients (3 female and 7 male) with 11 revision THAs. Patients underwent revision an average of 51 months (range 40-73 months) after index procedure. Mean follow-up after the revision was 31 months (range 24-37 months) and all patients underwent an MRI with metal artifact reduction software (MARS) at least two years after revision to assess for local polyethylene wear and osteolysis. RESULTS: The Harris Hip score improved from 92.2 (range 63.0-100.0) to 100.0 (p = 0.072). One patient had a one-time dislocation within seven days of surgery. No patient required additional surgeries. Radiographs showed no signs of component loosening and osteolysis and MRI imaging revealed no evidence of polyethylene wear or osteolysis. CONCLUSION: A dual mobility liner in an existing Birmingham cup can provide excellent clinical and radiological short-term results without MRI evidence of increased polyethylene wear. Post-operative hip precautions should be enforced.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Magnetic Resonance Imaging/methods , Metal-on-Metal Joint Prostheses/adverse effects , Reoperation/methods , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Female , Follow-Up Studies , Hip Joint/surgery , Humans , Male , Middle Aged , Prosthesis Design/adverse effects , Prosthesis Failure/adverse effects , Reoperation/adverse effects , Retrospective Studies , Salvage Therapy/adverse effects , Salvage Therapy/methods
14.
Arch Orthop Trauma Surg ; 138(2): 281-286, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29260384

ABSTRACT

INTRODUCTION: Although metal-on-metal (MoM) total hip arthroplasty (THA) and hip resurfacings (HR) have similar bearing surfaces and comparable wear rates, metal ion levels and risk of failure are higher for MoM-THA. The mechanism behind the increased metal ion levels in large head MoM-THA is not completely understood. The current study aims to identify predictive factors for increased metal ion levels in unilateral and bilateral large head MoM-THA. MATERIALS AND METHODS: 99 Birmingham modular MoM-THA in 87 patients with metal ion levels at least 36 months after index procedure were analyzed. Mean follow-up time was 61.3 months (range 37-108) and the relationship of the following variables (gender, age, BMI, follow-up time, UCLA Activity Score, cup inclination, femoral head size, bilateral surgery) on metal ion levels were analyzed with multivariate regression models. RESULTS: Multivariate regression analysis revealed that bilateral MoM-THA surgery (p < 0.001) had a positive predictive effect on cobalt serum levels, while BMI had a negative (p = 0.018). Female gender (p = 0.012), activity (p = 0.001) and bilateral MoM-THA (p = 0.004) were positively correlated with chromium levels. Positive independent predictors for the cobalt-chromium ratio in the multivariate analysis were overall follow-up time (p = 0.004), bilateral MoM-THA (p < 0.001) and femoral head size (p = 0.007). CONCLUSIONS: The data of the current study suggest that bilateral MoM-THA, increased patient activity levels and female gender are associated with increased chromium levels. Patients with larger component size, longer follow-up time and bilateral MoM-THAs have an increased cobalt-chromium ratio. These patients might be at increased risk for adverse local soft tissue reactions secondary to corrosion. Continuous close monitoring is recommended and bearing-surface change should be discussed if local tissue reactions occur.


Subject(s)
Arthroplasty, Replacement, Hip , Chromium/blood , Cobalt/blood , Metal-on-Metal Joint Prostheses/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/statistics & numerical data , Cohort Studies , Female , Humans , Male
15.
Sportverletz Sportschaden ; 31(4): 207-212, 2017 Dec.
Article in German | MEDLINE | ID: mdl-29228407

ABSTRACT

The introduction of new materials and better implant coatings seems to provide the prerequisites for more intense physical activities after total joint arthroplasties of the lower extremity. Despite recent advances in implant design and materials, recommendations for sport after total joint arthroplasty have not been updated over the past 20 years. The introduction of modern uncemented fixation as well as highly cross-linked polyethylene into total hip arthroplasty allow for a more active life-style without an increased risk of loosening or complications. This publication reviews the literature and presents the current knowledge to provide guidelines for orthopaedic surgeons treating patients after total joint replacement surgery.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Return to Sport , Humans , Prosthesis Design , Sports
16.
J Arthroplasty ; 32(4): 1176-1179, 2017 04.
Article in English | MEDLINE | ID: mdl-27913130

ABSTRACT

BACKGROUND: Topical tranexamic acid (TXA) was introduced to replace the previous targeted preoperative autologous blood donation (PABD) program. This study aims to analyze the efficacy of topical TXA compared with targeted PABD in anemic patients undergoing primary total hip arthroplasty (THA). METHODS: Two thousand two hundred fifty-one patients underwent primary THA between 2009 and 2013 using targeted autologous blood donation for 280 anemic patients (12%; Hb <12.5 g/dL). One thousand nine hundred seventy-one nonanemic patients (88%; ≥12.5 Hb/dL) received no blood management intervention. Starting in 2014, 505 consecutive patients were operated using 3 grams of topical TXA and abandoning PABD. Ninety-one patients (18%) were anemic and 414 (82%) nonanemic. RESULTS: The utilization of topical TXA in anemic patients resulted in higher hemoglobin levels on the first postoperative day (P = .014), but not on the second postoperative day (P = .198) compared with PABD. There was no difference in allogeneic transfusion rates between both groups: 12% vs 13% (P = .848). In the nonanemic group, TXA significantly increased hemoglobin levels on the first postoperative day (P = .001) as well as on the second postoperative day (P < .001), and resulted in a reduction in allogeneic transfusion rates from 8% to 1%. CONCLUSION: The present study suggests that topical TXA is equivalent to PABD in anemic patients and reduces transfusion rates and increases Hb-levels in nonanemic patients.


Subject(s)
Antifibrinolytic Agents/therapeutic use , Arthroplasty, Replacement, Hip , Blood Loss, Surgical/prevention & control , Blood Transfusion, Autologous/statistics & numerical data , Tranexamic Acid/therapeutic use , Administration, Topical , Adult , Aged , Aged, 80 and over , Anemia , Antifibrinolytic Agents/economics , Blood Donors , Blood Transfusion , Blood Transfusion, Autologous/economics , Female , Humans , Male , Middle Aged , Postoperative Period , Retrospective Studies , Tranexamic Acid/economics , Young Adult
17.
Clin Orthop Relat Res ; 475(5): 1386-1392, 2017 May.
Article in English | MEDLINE | ID: mdl-27830485

ABSTRACT

BACKGROUND: Progression of arthritis in the lateral compartment is one of the main failure modes of unicompartmental knee arthroplasty (UKA). The decision regarding whether to perform a medial UKA sometimes is made based on whether lateral-compartment osteophytes are visible on plain radiographs obtained before surgery, but it is not clear whether the presence of lateral-compartment osteophytes signifies that the cartilage in the lateral compartment is arthritic. QUESTIONS/PURPOSES: (1) Is the presence of lateral compartment osteophytes associated with biomechanical properties of lateral-compartment cartilage, and (2) are osteophytes in the lateral compartment associated with particular histologic features of cartilage in the lateral compartment? METHODS: Between May 2010 and January 2012, we performed 201 TKAs for varus osteoarthritis confirmed on standardized AP hip-to-ankle standing radiographs. All patients with a varus deformity were considered for this prospective study. During the enrollment period, 100 patients (101 knees) were not enrolled for this study because of declined consent or because they were unable to perform all required preoperative radiographic examinations. That left 84 patients (100 knees), of whom an additional 23 patients (27%) were excluded because either radiographic or biomechanical data were missing. For final analysis, 61 patients (71 knees) were available. There were 29 males (48%) and 32 females (52%) with a mean age of 65 years (range, 49-89 years). Their mean BMI was 26 kg/m2 (range, 17-47 kg/m2). Lateral-compartment osteophytes were graded by two observers on AP standing knee radiographs based on a template of the Osteoarthritis Research Society International (OARSI) radiographic atlas. During surgery, osteochondral plugs were harvested from the lateral tibial plateau and the distal lateral femur for biomechanical and histologic assessments. The intrinsic material coefficients aggregate modulus (Ha) and dynamic modulus (DM) were determined by applying a compressive load of 20 g for 1 hour. The histologic analysis was performed according to the qualitative osteoarthritis cartilage histopathology assessment system. The Mann-Whitney U test was performed to compare the distribution of variables. Power analysis was performed for the Mann-Whitney U test using an alpha of 0.05, a power of 80%, and a sample size of 71 resulting in a detectable effect size of 0.6. Owing to the limited sample size, only medium or large effects in changes of biomechanical properties can be excluded with adequate power. RESULTS: Ha and DM were not different with the numbers available when comparing knees with osteophyte Grades 0, 1, and 2 on the lateral tibia. For Grade 3 tibial osteophytes (n = 3), the lateral tibia cartilage showed low Ha (0.39 MPa; SD, 0.17 MPa) and low DM (2.85 MPa; SD, 2.12 MPa). On the lateral femur, no differences of Ha and DM were observed with the numbers available between Grades 0 to 3 osteophytes. No differences with the numbers available in the OARSI histologic grades on the lateral tibia plateau and the distal lateral femur were observed between the different osteophyte grades. CONCLUSIONS: Lateral-compartment osteophytes are not associated with biomechanically weaker cartilage or with more-advanced histologic signs of degeneration of lateral-compartment cartilage in knees with varus arthritis. Given the small sample size of 71, the study was underpowered to detect small-to-modest decreases in biomechanical properties. Future studies with larger sample sizes are needed to confirm the current findings. CLINICAL RELEVANCE: Factors other than the presence or absence of lateral-compartment osteophytes should be considered when evaluating patients with medial-compartment arthritis for medial UKA. Future studies are required to define the limitations of plain radiographs to rule out cartilage degeneration in the lateral compartment of varus knees.


Subject(s)
Cartilage, Articular/diagnostic imaging , Knee Joint/diagnostic imaging , Osteoarthritis, Knee/diagnostic imaging , Osteophyte/diagnostic imaging , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/adverse effects , Biomechanical Phenomena , Cartilage, Articular/pathology , Cartilage, Articular/physiopathology , Cartilage, Articular/surgery , Female , Humans , Knee Joint/pathology , Knee Joint/physiopathology , Knee Joint/surgery , Male , Middle Aged , Osteoarthritis, Knee/pathology , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Osteophyte/pathology , Patient Selection , Predictive Value of Tests , Retrospective Studies , Risk Assessment , Risk Factors , Treatment Outcome
18.
J Arthroplasty ; 32(4): 1180-1185, 2017 04.
Article in English | MEDLINE | ID: mdl-27839959

ABSTRACT

BACKGROUND: This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach. METHODS: Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset. RESULTS: The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259). CONCLUSION: Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Acetabulum/diagnostic imaging , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/statistics & numerical data , Female , Fluoroscopy/methods , Humans , Leg Length Inequality/surgery , Male , Middle Aged , Patient Positioning , Postoperative Period , Radiography , Retrospective Studies
19.
J Arthroplasty ; 32(3): 788-792, 2017 03.
Article in English | MEDLINE | ID: mdl-27836579

ABSTRACT

BACKGROUND: Intact cartilage in the lateral compartment is an important requirement for medial unicompartmental knee arthroplasty. This study sought to determine how measurements of joint space width in the lateral compartment on valgus stress radiographs compare to cartilage thickness as measured with a precise needle test, and whether cartilage thickness is a predictor of cartilage degeneration. METHODS: A consecutive series of 100 knees undergoing total knee arthroplasty for end-stage varus osteoarthritis was studied. Twenty-eight knees were retrospectively excluded because not all data were available, leaving 72 knees (61 patients; mean age, 67 years [49-87]). On calibrated valgus stress radiographs, lateral-compartment joint space width was measured. During surgery, osteochondral samples of the distal lateral femur and the lateral tibia plateau were harvested. Cartilage thickness and histology were assessed. Cartilage thickness of tibia and femur was defined as lateral-compartment cartilage thickness. RESULTS: Lateral-compartment joint space width on valgus stress radiographs and lateral-compartment cartilage thickness correlated well (rs = 0.671, P < .001). However, no correlation of cartilage histology according to the osteoarthritis cartilage histopathology assessment system, and cartilage thickness on the lateral tibia plateau (rs = -0.060, P = .614) and cartilage thickness on the distal lateral femur (rs = -0.128, P = .282) was observed. CONCLUSION: Valgus stress radiographs can assess combined cartilage thickness in the lateral compartment of the knee. Cartilage thickness, however, is a poor predictor of cartilage degeneration.


Subject(s)
Cartilage, Articular/diagnostic imaging , Knee Joint/diagnostic imaging , Osteoarthritis, Knee/diagnostic imaging , Radiography/methods , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee , Cartilage/pathology , Female , Femur/surgery , Humans , Knee Joint/surgery , Male , Middle Aged , Osteoarthritis, Knee/surgery , Prospective Studies , Tibia/surgery
20.
J Arthroplasty ; 31(12): 2871-2874, 2016 12.
Article in English | MEDLINE | ID: mdl-27329580

ABSTRACT

BACKGROUND: The present study investigates the novel Synovasure periprosthetic joint infection (PJI) lateral flow test device for detection of alpha-defensin and attempts to determine its diagnostic accuracy for the intraoperative diagnosis of PJI and compares it to frozen section. METHODS: Forty consecutive patients, who underwent revision surgery, between September 2014 and September 2015 were included. The patients underwent 29 revision total knee arthroplasties and 11 revision total hip arthroplasties. Twelve patients had a confirmed PJI based on Musculoskeletal Infection Society criteria, and 28 patients were considered aseptic. RESULTS: The overall accuracy to detect PJI using the lateral flow assay was 85% (95% CI 70%-93%). The device has a positive predictive value of 80% (95% CI 44%-96%) and a negative predictive value of 87% (95% CI 68%-96%) and showed a sensitivity of 67% (95% CI 35%-89%) and specificity of 93% (95% CI 75%-99%). Frozen section had a lower sensitivity (58% [95% CI 29%-84%]) but a higher specificity (96% [95% CI 80%-100%]). Receiver operator curve analysis demonstrates an area under the curve of the Synovasure PJI Lateral Flow Test Kit and frozen section of 0.80 and 0.77, respectively. CONCLUSION: The present study suggests that the intraoperative lateral flow test is at least equivalent to intraoperative frozen section and is a useful tool to confirm the absence of PJI. Although the clinical results are promising, they are not as good as previous studies using alpha-defensin levels measured in a laboratory.


Subject(s)
Arthritis, Infectious/surgery , Biomarkers/analysis , C-Reactive Protein/analysis , Prosthesis-Related Infections/surgery , Synovial Fluid/chemistry , alpha-Defensins/analysis , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Female , Frozen Sections , Humans , Intraoperative Period , Male , Middle Aged , Prospective Studies , ROC Curve , Reoperation , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...