Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 132(8): 083402, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38457696

ABSTRACT

We report on laser cooling of a large fraction of positronium (Ps) in free flight by strongly saturating the 1^{3}S-2^{3}P transition with a broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is produced in a magnetic and electric field-free environment. We observe two different laser-induced effects. The first effect is an increase in the number of atoms in the ground state after the time Ps has spent in the long-lived 2^{3}P states. The second effect is one-dimensional Doppler cooling of Ps, reducing the cloud's temperature from 380(20) to 170(20) K. We demonstrate a 58(9)% increase in the fraction of Ps atoms with v_{1D}<3.7×10^{4} ms^{-1}.

2.
Rev Sci Instrum ; 92(5): 054704, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34243289

ABSTRACT

The work describes a novel approach to the design of a fast, multichannel measurement system for plasma diagnostics [A. Wojenski et al., Fusion Eng. Des. 123, 727 (2016)]. Its main scope is to provide measurements of soft X-ray (SXR) emission during plasma phenomena at the W-Environment in Steady-state Tokamak (WEST), especially for monitoring and tracing tungsten impurities. This paper describes the vertical Gas Electron Multiplier (GEM) camera installed at the WEST [M. Chernyshova et al., J. Instrument. 10, P10022 (2015)]. The designed GEM detector readout board has more than 100 channels, resulting in high-performance requirements for the data acquisition and processing system. The novel system construction approach is that the unit works on the raw signals providing a high quality of the data, especially in the scope of pileup effect analysis. In the case of doubtful results, the source data can be easily reviewed offline. The data selection and transmission are done in Field-Programmable Gate Arrays (FPGAs) on the custom boards with the custom Peripheral Component Interconnect (PCI)-Express Gen2 switch that allows us to register signals from multiple FPGAs and then process the data by complex algorithms [G. Kasprowicz et al., J. Fusion Energy 38, 480 (2019)]. The firmware is replaceable and different working modes can be applied (some under verification): global trigger mode, high-speed data serialization, and extended signal registration. Low level optimized central processing unit software for data readout was also designed [P. Linczuk et al., J. Instrum. 14, C05001 (2019)]. The installation of the system is described due to complex system components' distribution. The first results of the successful acquisition of the plasma at the WEST are discussed. The corresponding SXR energy and topology spectra were computed. Those are the first technical measurements of the system to ensure verification of data quality.

3.
Rev Sci Instrum ; 89(10): 10G106, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399675

ABSTRACT

A detecting system based on the Gas Electron Multiplier (GEM) technology is considered for tokamak plasma radiation monitoring. In order to estimate its capabilities in processing and recording intense photon flux (up to ∼0.1 MHz/mm2), the imaging effectiveness of GEM detectors was tested with different patterned anode planes (i.e., different signal readouts): a simple hexagonal readout structure and three structures with interconnected electrodes (XY square, XY rectangular, and UXV). It was found that under intense photon flux, all the readouts fail to account for a considerable amount of the incoming signals due to mostly photon position determination ambiguity and overlapped signals. Analysis of the signals that can be used to determine photon position and energy unambiguously showed that the UXV readout structure is more effective among the readouts with interconnected electrodes. Along with similar spatial resolution and accuracy, the UXV based layout could be considered as a quite promising base of the interconnected anode electrodes configuration, keeping in mind that the photon rate capability has to be improved for the final application.

5.
Rev Sci Instrum ; 87(11): 11E336, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910377

ABSTRACT

The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

6.
Rev Sci Instrum ; 87(11): 11E325, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910468

ABSTRACT

A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

7.
Rev Sci Instrum ; 85(11): 11E425, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430332

ABSTRACT

The high resolution X-Ray crystal spectrometer at the JET tokamak has been upgraded with the main goal of measuring the tungsten impurity concentration. This is important for understanding impurity accumulation in the plasma after installation of the JET ITER-like wall (main chamber: Be, divertor: W). This contribution provides details of the upgraded spectrometer with a focus on the aspects important for spectral analysis and plasma parameter calculation. In particular, we describe the determination of the spectrometer sensitivity: important for impurity concentration determination.

SELECTION OF CITATIONS
SEARCH DETAIL
...