Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Struct Dyn ; 11(2): 024309, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38595978

ABSTRACT

For time-resolved diffraction studies of irreversible structural dynamics upon photoexcitation, there are constraints on the number of perturbation cycles due to thermal effects and accumulated strain, which impact the degree of crystal order and spatial resolution. This problem is exasperated for surface studies that are more prone to disordering and defect formation. Ultrafast electron diffraction studies of these systems, with the conventional stroboscopic pump-probe protocol, require repetitive measurements on well-prepared diffraction samples to acquire and average signals above background in the dynamic range of interest from few tens to hundreds of picoseconds. Here, we present ultrafast streaked low-energy electron diffraction (LEED) that demands, in principle, only a single excitation per nominal data acquisition timeframe. By exploiting the space-time correlation characteristics of the streaking method and high-charge 2 keV electron bunches in the transmission geometry, we demonstrate about one order of magnitude reduction in the accumulated number of the excitation cycles and total electron dose, and 48% decrease in the root mean square error of the model fit residual compared to the conventional time-scanning measurement. We believe that our results demonstrate a viable alternative method with higher sensitivity to that of nanotip-based ultrafast LEED studies relying on a few electrons per a single excitation, to access to all classes of structural dynamics to provide an atomic level view of surface processes.

2.
Ultramicroscopy ; 240: 113579, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35780682

ABSTRACT

The effect of window material on electron beam induced phenomena in liquid phase electron microscopy (LPEM) is an interesting yet under-explored subject. We have studied the differences of electron beam induced gold nanoparticle (AuNP) growth subject to three encapsulation materials: Silicon Nitride (Si3N4), carbon and formvar. We find Si3N4 liquid cells (LCs) to result in significantly higher AuNP growth yield as compared to LCs employing the other two materials. In all cases, an electrical bias of the entire LC structures significantly affected particle growth. We demonstrate an inverse correlation of the AuNP growth rate with secondary electron (SE) emission from the windows. We attribute these differences at least in part to variations in SE emission dynamics, which is seen as a combination of material and bias dependent SE escape flux (SEEF) and SE return flux (SERF). Furthermore, our model predictions qualitatively match electrochemistry expectations.

3.
Microsc Microanal ; 27(1): 44-53, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33280632

ABSTRACT

Liquid-phase transmission electron microscopy is a technique for simultaneous imaging of the structure and dynamics of specimens in a liquid environment. The conventional sample geometry consists of a liquid layer tightly sandwiched between two Si3N4 windows with a nominal spacing on the order of 0.5 µm. We describe a variation of the conventional approach, wherein the Si3N4 windows are separated by a 10-µm-thick spacer, thus providing room for gas flow inside the liquid specimen enclosure. Adjusting the pressure and flow speed of humid air inside this environmental liquid cell (ELC) creates a stable liquid layer of controllable thickness on the bottom window, thus facilitating high-resolution observations of low mass-thickness contrast objects at low electron doses. We demonstrate controllable liquid thicknesses in the range 160 ± 34 to 340 ± 71 nm resulting in corresponding edge resolutions of 0.8 ± 0.06 to 1.7 ± 0.8 nm as measured for immersed gold nanoparticles. Liquid layer thickness 40 ± 8 nm allowed imaging of low-contrast polystyrene particles. Hydration effects in the ELC have been studied using poly-N-isopropylacrylamide nanogels with a silica core. Therefore, ELC can be a suitable tool for in situ investigations of liquid specimens.

4.
Nat Commun ; 11(1): 996, 2020 02 21.
Article in English | MEDLINE | ID: mdl-32081905

ABSTRACT

Serial X-ray crystallography at free-electron lasers allows to solve biomolecular structures from sub-micron-sized crystals. However, beam time at these facilities is scarce, and involved sample delivery techniques are required. On the other hand, rotation electron diffraction (MicroED) has shown great potential as an alternative means for protein nano-crystallography. Here, we present a method for serial electron diffraction of protein nanocrystals combining the benefits of both approaches. In a scanning transmission electron microscope, crystals randomly dispersed on a sample grid are automatically mapped, and a diffraction pattern at fixed orientation is recorded from each at a high acquisition rate. Dose fractionation ensures minimal radiation damage effects. We demonstrate the method by solving the structure of granulovirus occlusion bodies and lysozyme to resolutions of 1.55 Å and 1.80 Å, respectively. Our method promises to provide rapid structure determination for many classes of materials with minimal sample consumption, using readily available instrumentation.


Subject(s)
Crystallography/methods , Proteins/chemistry , Microscopy, Electron, Scanning Transmission , Models, Molecular , Muramidase/chemistry , Muramidase/ultrastructure , Nanoparticles/chemistry , Nanoparticles/ultrastructure , Occlusion Body Matrix Proteins/chemistry , Occlusion Body Matrix Proteins/ultrastructure , Particle Size , Protein Conformation , Proteins/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL
...