Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
Thorac Cardiovasc Surg ; 58(4): 246-8, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20514587

ABSTRACT

Traditionally, reoperations for mitral valve replacement are carried out under cardioplegic arrest with cross-clamping of the ascending aorta via a median sternotomy. In this case, the mitral valve replacement operation was performed with an on-pump beating heart technique without cross-clamping the aorta and via a right thoracotomy because of diffuse adhesions around the ascending aortic tube graft. A 44-year-old male patient had undergone a Bentall operation via a median sternotomy for annulo-aortic ectasia 3 years ago. He was admitted to the hospital complaining of palpitation and dyspnea. Transthoracic echocardiography revealed 4th degree mitral insufficiency. Mitral valve replacement was carried out through a right thoracotomy using an on-pump beating heart technique without cross clamping the aorta. In conclusion, mitral valve replacement with an on-pump beating heart technique via a right thoracotomy offers a safe approach when excessive dissection is required to place a cross-clamp to the ascending aorta.


Subject(s)
Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation , Cardiopulmonary Bypass , Heart Valve Prosthesis Implantation/methods , Marfan Syndrome/surgery , Mitral Valve Insufficiency/surgery , Thoracotomy , Adult , Aortic Diseases/pathology , Dilatation, Pathologic , Humans , Male , Sternotomy , Tissue Adhesions
2.
J Cardiovasc Surg (Torino) ; 48(4): 513-8, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17653014

ABSTRACT

AIM: Reoperations have become of increasing frequency in the last four decades. Redo surgery is more complex than primary surgery and is associated with higher mortality and morbidity. We present our immediate and mid-term results of mitral and aortic prosthetic valve replacement undertaken with beating heart technique. METHODS: The prospective study included 26 consecutive redo valve surgery patients who underwent valve re-replacement. The operation was carried out on a beating heart using normothermic bypass without cross-clamping the aorta for mitral valve surgery and retrograde coronary sinus normothermic noncardioplegic blood perfusion during cross-clamping the aorta for aortic valve procedures. RESULTS: Twenty-six patients (mean age 50+/-15 years) underwent reoperation with beating heart technique. Twenty (76.9%) mitral prosthetic replacements, 4 (15.4%) aortic prosthetic replacements, and 2 (7.7%) double valve replacements were achieved. Fourteen patients (53.8%) were operated for prosthetic valve dysfunction. Eighteen patients (69.2%) were in NYHA class III or IV preoperatively. Mean bypass time was 85+/-30 min. Mean duration of ventilation was 13.6+/-6 h, mean intensive unit stay was 2.8+/-6.4 days, and mean hospital stay was 8.3+/-7.2 days. Two (7.7%) patients required high dose inotropic support and in one patient (3.8%) intra-aortic balloon support was required. Pulmonary complication occurred in 1 patient (3.8%), low cardiac output in 1 patient (3.8%), and re-exploration for bleeding in 2 patients (7.7%). Operative mortality was not observed. CONCLUSION: Normothermic on-pump beating heart valve replacement offers a safe alternative to cardioplegic arrest in high-risk group. Complication rates are low and perioperative mortality is lower than with conventional surgery. Beating heart technique has the advantage of maintaining physiologic condition of the heart throughout the procedure.


Subject(s)
Aortic Valve , Cardiopulmonary Bypass/methods , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Mitral Valve , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Heart Valve Diseases/diagnosis , Heart Valve Diseases/etiology , Humans , Male , Middle Aged , Prospective Studies , Reoperation/methods , Treatment Outcome
3.
Thorac Cardiovasc Surg ; 55(4): 259-61, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17546559

ABSTRACT

Aortic root surgery has traditionally been performed with an arrested and cooled heart using cardioplegia. A new technique of myocardial protection was utilized in the treatment of ascending aortic aneurysm with severe aortic valve regurgitation requiring aortic root replacement with the Cabrol technique. Retrograde and antegrade perfusion of the heart with blood allowed the surgical operation to be performed safely while the heart was beating and eliminated the ischemic reperfusion injury which occurs during cardioplegic arrest and reinstitution of blood perfusion after removal of the aortic cross-clamping required in traditional techniques.


Subject(s)
Aortic Aneurysm/surgery , Cardiopulmonary Bypass/methods , Heart Valve Prosthesis Implantation , Perfusion/methods , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Blood Vessel Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Myocardial Reperfusion Injury/prevention & control
4.
Thorac Cardiovasc Surg ; 53(5): 285-90, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16208614

ABSTRACT

BACKGROUND: There are few reports on postoperative late cardiac tamponade with surgical therapy in the literature. METHODS: Hospital records of 87 patients with postoperative late cardiac tamponade who had undergone cardiac surgery between January 1999 and December 2003 were evaluated retrospectively. RESULTS: Out of 8400 patients who had undergone cardiac surgery, 87 patients (1 %) had postoperative late cardiac tamponade. The incidence was 0.1 % for patients with coronary artery bypass grafting and 3.4 % for those with heart valve replacement ( p < 0.01). Subxiphoid midline incision was carried out in 67 patients (77 %). Conversion to re-sternotomy was required in 8 patients due to either ineffective drainage (5 patients, 7.5 %) or laceration and bleeding (3 patients, 4.5 %). Re-sternotomy was undertaken in 20 patients with no complication. Early death occurred in 3 patients with subxiphoid drainage (3.5 %), two of which were related to bleeding. Out of 84 patients who survived, 10 patients had recurrent cardiac tamponade, 5 of which required surgical drainage (6 %). CONCLUSIONS: Bleeding due to dense adhesions between the epicardium and the sternum may be encountered during subxiphoid drainage for postoperative late cardiac tamponade and lead to a 3 % mortality rate.


Subject(s)
Cardiac Surgical Procedures , Cardiac Tamponade/etiology , Drainage/methods , Postoperative Complications/etiology , Adolescent , Adult , Aged , Aortic Valve/pathology , Aortic Valve/surgery , Cardiac Tamponade/mortality , Cardiac Tamponade/surgery , Coronary Artery Bypass , Coronary Disease/surgery , Drainage/statistics & numerical data , Dyspnea/etiology , Dyspnea/surgery , Echocardiography , Female , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/surgery , Reoperation , Retrospective Studies , Sternum/surgery , Survival Rate , Time Factors , Treatment Outcome , Tricuspid Valve/pathology , Tricuspid Valve/surgery
5.
Eur Surg Res ; 36(4): 241-8, 2004.
Article in English | MEDLINE | ID: mdl-15263830

ABSTRACT

OBJECTIVES: The performance of small-diameter (3-5-mm) vascular grafts still poses a challenge in the field of vascular surgery. We present here our preliminary experience with implanting unique small-sized polycarbonate urethane vascular grafts in 7 dogs. MATERIAL AND METHODS: Each animal was implanted with 4 interposition grafts, 2 femoral and 2 carotid. No anti-thrombotic medication was administered. Doppler sonography was performed at 3-month intervals to examine for patency and flow characteristics. Animals were sacrificed electively at 3, 6 and 12 months. RESULTS: At 3 months, all grafts were patent. After 6 months, 3 grafts occluded and at 1 year a further 6 grafts occluded. Hence 9 of 28 grafts occluded (67.9% patency). During the study, no correlation could be established between flow velocity or resistance index and occlusion. Histopathology showed intimal hyperplasia to be the cause of occlusion. CONCLUSIONS: Compared to literature data on small-diameter grafts in the same position, ADIAM's Biomechanical grafts performed clearly better. Compliance data suggest a correlation between elastic compliance and patency.


Subject(s)
Blood Vessel Prosthesis , Carotid Arteries/surgery , Femoral Artery/surgery , Polyurethanes , Animals , Dogs , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/prevention & control , Graft Survival , Male , Prosthesis Implantation , Ultrasonography, Doppler
6.
Ann N Y Acad Sci ; 1031: 352-6, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15753168

ABSTRACT

We studied whether cardiopulmonary bypass (CPB) has any immediate impact on the initiation of antioxidative defenses in the body by measuring F(2)-isoprostanes and alpha- and gamma-tocopherol, respectively. 8-iso-PGF(2alpha) levels increased significantly within 3 minutes and until the end of CPB. alpha-Tocopherol levels increased gradually at 20 min during CPB and continued until 6 hours after CPB. gamma-Tocopherol levels followed a similar fashion at the end of CPB. 8-iso-PGF(2alpha) and tocopherol levels kept at basal level 12 and 24 hours post CPB. These findings suggest that an increased free radical-induced oxidative stress together with a gradual appearance of antioxidative defense system during and after CPB.


Subject(s)
Coronary Artery Bypass , Oxidative Stress , alpha-Tocopherol/blood , gamma-Tocopherol/blood , Adult , Aged , Antioxidants/analysis , Female , Humans , Male , Middle Aged
7.
Free Radic Biol Med ; 34(7): 911-7, 2003 Apr 01.
Article in English | MEDLINE | ID: mdl-12654480

ABSTRACT

Free radicals are believed to be involved in postsurgery-related complications. We studied whether cardiopulmonary bypass (CPB) operation has any immediate impact on the initiation of oxidative stress and inflammatory response by measuring isoprostanes and prostaglandin F2alpha during and 24 h following CPB. The levels of 8-iso-PGF2alpha (a major F2-isoprostane and biomarker of oxidative stress) and 15-keto-dihydro-PGF2alpha (a major metabolite of PGF2alpha and biomarker of inflammatory response) were measured in frequently collected plasma samples before, during, and up to 24 h postsurgery in 21 patients. 8-Iso-PGF2alpha levels significantly increased within 3 min (p <.0001) and continued until 50 min (p <.0001) during CPB. On the contrary, no significant increase of inflammatory response indicator, 15-keto-dihydro-PGF2alpha was found during and up to 24 h postoperatively. These findings establish an increased free radical-induced oxidative stress activity rather than inflammatory response after CPB.


Subject(s)
Cardiopulmonary Bypass/adverse effects , Dinoprost/analogs & derivatives , Free Radicals , Isoprostanes/blood , Oxidative Stress , Adult , Aged , Dinoprost/chemistry , Female , Humans , Inflammation , Ischemia , Male , Middle Aged , Models, Chemical , Oxygen/metabolism , Prostaglandins/metabolism , Radioimmunoassay , Time Factors
8.
Panminerva Med ; 44(4): 359-63, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12434119

ABSTRACT

BACKGROUND: Mechanical prosthetic heart valve thrombosis is a serious complication with an incidence of 1-6%. The reduction in active vitamin-K dependent protein C and S levels caused by warfarin treatment also results in a prothrombotic state. This study was conducted to investigate the connection between protein C (PC), protein S (PS), antithrombin III (ATIII) deficiency and prosthetic mechanical valve thrombosis. METHODS: Twenty-nine of the 283 patients who underwent valve replacement with St. Jude medical prosthesis had mechanical valve thrombosis (group 2). The rest were considered as group 1. Twelve of the 29 patients (41.4%) had isolated aortic valve replacement, 12 had isolated mitral valve replacement (41.4%) and 5 patients had double valve replacement (17.2%). Most of the patients had rheumatic valve disease at their 1st operation. The mean time of occurrence for mechanical valve occlusion was 4.1+/-1.0 years following surgery. RESULTS: The values of PC, PS and ATIII were obtained when the mechanical valves stuck or at routine follow-up. PC, PS and ATIII levels were significantly lower in the mechanical valve thrombosis group. PC levels were 75.4+/-37.6% and 49.9+/-32.2% in group 1 and 2, respectively (p=0.001). PC, PS and ATIII values were mostly lower in the 2nd group but this difference only became significant after at least 2 years of warfarin usage. CONCLUSIONS: Natural anticoagulant levels can be low during the use of warfarin. In which case the dose can be increased in order to hold the international normalized ratio (INR) at 3-3.5. However, more frequent follow-up is required and patients should be investigated for hypercoagulation states or deficiency in anticoagulant proteins. Patients referred to hospital with any mechanical valve thrombosis or recurrent thromboembolism should be evaluated for hypercoagulant proteins.


Subject(s)
Antithrombin III/metabolism , Heart Valve Prosthesis/adverse effects , Protein C/metabolism , Protein S/metabolism , Thrombosis/etiology , Adult , Aortic Valve Insufficiency/surgery , Female , Humans , Male , Middle Aged , Mitral Valve Insufficiency/surgery
9.
Panminerva Med ; 44(2): 129-33, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12032431

ABSTRACT

BACKGROUND: The effect of Mg++SO4 on myocardial hemodynamics was investigated in this study. METHODS: Twelve dogs were entered in this research. Six dogs received Mg++SO4 and the remaining dogs were considered as controls. The amount of Mg++SO4 that was administered to the animals was 0.15 mmol/kg/hr each. The left anterior descending artery was occluded for a period of 1 hour and the drug was administered during reperfusion. RESULTS: Two hours after reperfusion, cardiac output was 1275+/-50 ml/min in the control group and 1475+/-25 ml/min in the Mg++SO4 group (p<0.05), pulmonary capillary wedge pressure was 18+/-3 mmHg in the control group and 12+/-2 mmHg in the Mg++SO4 group. CONCLUSIONS: In this study it was shown that Mg++SO4 usage after 1 hour arterial occlusion and 2 hours reperfusion protects the heart from the adverse effects of ischemia/reperfusion and had a better central hemodynamics.


Subject(s)
Magnesium Sulfate/therapeutic use , Myocardial Ischemia/drug therapy , Myocardial Reperfusion Injury/drug therapy , Animals , Cardiac Output/drug effects , Dogs , Hemodynamics/drug effects , Myocardial Ischemia/physiopathology , Myocardial Reperfusion Injury/physiopathology
10.
Panminerva Med ; 42(1): 11-5, 2000 Mar.
Article in English | MEDLINE | ID: mdl-11019598

ABSTRACT

BACKGROUND: The effect of ATP-MgCl2 on myocardial metabolism and hemodynamics was investigated in this study. METHODS: Twelve dogs were entered in this research. Six dogs received ATP-MgCl2 and the remaining dogs were considered as controls. The amount of ATP and MgCl2 concentration of this solution is 100 mumol/ml each. The volume administered to the animals during the aortic occlusion is 0.25 ml/kg/hour; in the solution are 100 mumol/ml dose each. The volume administered to the animals during reperfusion is 0.25 ml/kg/hour. The left anterior descending artery was occluded for a period of one hour and the drug was administered during reperfusion. RESULTS: Three hours after reperfusion, cardiac output was 1524 +/- 26 ml/min in the control group and 1638 +/- 47 ml/min in the ATP-MgCl2 group (p < 0.05), pulmonary capillary wedge pressure was 14 +/- 3 in the control group and 8 +/- 2 in the ATP-MgCl2 group. At the same time interval tissue ATP and lactate level was 7 +/- 3, 1.3 +/- 0.4 in the control group and 14 +/- 2, 0.0 +/- 0.2 in the ATP-MgCl2 group respectively (p < 0.05). CONCLUSIONS: In this study we demonstrated that ATP-MgCl2 usage after one hour of arterial occlusion protects the heart from the adverse effects of ischemia/reperfusion.


Subject(s)
Adenosine Triphosphate/therapeutic use , Myocardial Ischemia/drug therapy , Myocardial Reperfusion Injury/drug therapy , Animals , Coronary Circulation/drug effects , Dogs , Heart/drug effects , Hemodynamics/drug effects , Myocardium/metabolism
11.
Panminerva Med ; 42(2): 109-17, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10965772

ABSTRACT

BACKGROUND: The aim of the study was to evaluate the efficacy of iloprost on myocardial insufficiency associated with hypovolemic shock in dogs. We designed the study as a controlled randomized study. METHODS: Sixteen mixed-breed dogs were included into the study and divided into two equal groups as the control and iloprost groups. Mean arterial pressure was reduced to 45 mmHg by withdrawing the arterial blood into citrated bags. The control group did not receive any drug but the other group received iloprost at a rate of 20 ng/kg/min by an infusion pump. Iloprost infusion was started 30 min after the blood pressure was reduced to 45 mmHg. All measurements were made before removal of blood, 45 min after exsanguination and at 1 hour intervals for 3 hours. Left ventricular stroke work index was measured 72 hours after the study. The hemodynamic and biochemical parameters and blood gas analysis were obtained. RESULTS: After hemorrhage, cardiac index (CI) decreased significantly from 132 +/- 14 to 51 +/- 8 ml/kg/min in the control group and from 128 +/- 11 ml/kg/min to 47 +/- 13 ml/kg/min in the iloprost group, respectively but at the end of the third hour it was 81 +/- 8 ml/kg/min in the control group and 105 +/- 6 ml/kg/min in the iloprost group (p < 0.05). Tumor necrosis factor-alpha (TNF alpha) was 41 +/- 8 pg/ml in the control group and 18 +/- 6 in the iloprost group 3 hours after bleeding (p < 0.05). Tumor necrosis factor-alpha concentration was significantly higher in the control group than in the iloprost group. There was no significant difference in pH between the groups but actual bicarbonate concentrations were different between the groups (p < 0.05). At the end of the third hour total body oxygen consumption was 105 +/- 11 ml/min in the control group and 132 +/- 12 ml/min in the iloprost group (p < 0.05). Oxygen delivery 3 hours after hemorrhage was 201 +/- 19 ml/min in the control group and 252 +/- 24 ml/min in the iloprost group (p > 0.05). Left ventricular stroke work index was higher in the iloprost group (p < 0.05). CONCLUSIONS: Hemorrhagic shock causes tumor necrosis factor-alpha release which may lead to multiple organ failure. Organ dysfunction still persists even after the appropriate treatment. Iloprost attenuates the release of tumor necrosis factor-alpha which may improve the adverse effects of hemorrhagic shock.


Subject(s)
Iloprost/therapeutic use , Platelet Aggregation Inhibitors/therapeutic use , Shock, Hemorrhagic/drug therapy , Vasodilator Agents/therapeutic use , Animals , Dogs , Shock, Hemorrhagic/physiopathology
12.
J Cardiovasc Surg (Torino) ; 41(1): 31-6, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10836218

ABSTRACT

BACKGROUND: Between 1986 and 1996, 194 patients underwent isolated aortic valve replacement with 21-23 no. St. Jude Medical mechanical heart valves (small sized group) and 163 patients with 27-29 no. (large sized group). METHODS: The mean age at operation was 45.04+/-15.90 years (range: 12-76 years) for the small sized group and 38.05+/-13.41 years (range: 16-68 years) for the large sized group. Preoperatively, 39.7% of the patients from the small sized group and 42.9% from the large sized group had pure aortic stenosis, 31.9% and 27.6% had pure aortic insufficiency. Most of the patients had rheumatic valve disease. RESULTS: The overall hospital mortality rate was 12.4% and 3.07% respectively in the small sized and large sized groups (p<0.001). The overall actuarial survival rate for 10 years was 95.33+/-2.73% and 93.06+/-3.98% respectively in the small sized group and large sized group (p>0.05). In the small sized group male sex and all complications, in large sized group age and all complications were the statistically important hospital mortality predictors (p<0.05). CONCLUSIONS: Although, operative mortality and long term morbidity were higher in the small sized group, these changes did not reflect the actuarial survivals between the groups. Small sized valves carry some risk, but these risks do not affect long-term survival.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis , Adolescent , Adult , Aged , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Child , Female , Hospital Mortality , Humans , Male , Middle Aged , Postoperative Complications/mortality , Prosthesis Design , Reoperation , Rheumatic Heart Disease/mortality , Rheumatic Heart Disease/surgery , Survival Rate
13.
J Cardiovasc Surg (Torino) ; 41(1): 45-50, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10836220

ABSTRACT

BACKGROUND: Effectiveness of retrograde coronary sinus perfusion with the use of carnitine supplementation over the severity of ischemia/reperfusion injury, in acute coronary occlusion. METHODS: Eighteen mongrel dogs, divided equally into control, retrograde perfusion (retroperfusion) and carnitine retroperfusion (retrocarnitine) groups. After taking the basal values, the left anterior descending artery was occluded. At the fifteenth minute, without ending the occlusion, retrograde coronary sinus cardioplegia in the retroinfusion group and in the carnitine group, 0.15 mmol/kg of L-carnitine retroperfusion was performed. Then, hemodynamic and biochemical measurements were taken till the end of 120 minutes. The control group had no retroperfusion or medical therapy. RESULTS: Between the three groups, there was a statistically significant difference in cardiac index, mean arterial pressure, mean pulmonary artery pressure, pulmonary capillary wedge pressure, right atrial pressure as hemodynamic parameters and myocardial oxygen extraction, myocardial Lactate extraction, protein thiols and Malonyl dialdehyde (MBA) as biochemical parameters, at different time intervals (p<0.05). CONCLUSION: Coronary sinus retroperfusion with carnitine is found to be very effective in reducing oxygen free radical release and however this advantage did not switch to the hemodynamic function between the retrograde coronary sinus infusion group and retroinfusion carnitine group. In our opinion retrograde coronary sinus perfusion with the use of carnitine supplementation reduces the severity of ischemia/reperfusion injury.


Subject(s)
Carnitine/administration & dosage , Myocardial Infarction/physiopathology , Myocardial Reperfusion Injury/prevention & control , Animals , Dogs , Energy Metabolism/drug effects , Energy Metabolism/physiology , Hemodynamics/drug effects , Hemodynamics/physiology , Myocardial Reperfusion Injury/physiopathology , Myocardium/metabolism , Perfusion/methods , Stroke Volume/drug effects , Stroke Volume/physiology
14.
J Cardiovasc Surg (Torino) ; 41(1): 89-93, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10836230

ABSTRACT

BACKGROUND: Surgical procedures on the thoracoabdominal part of the aorta make the spinal cord vulnerable to ischemia. Paraplegia is the most severe complication following thoracoabdominal operations. In this study, iloprost was used as an agent to decrease the severity of ischemia and reperfusion injury to the spinal cord during aortic occlusion and declamping. METHODS: Twelve adult mongrel dogs weighing 17+/-2 kg were used in this study. The animals were randomly assigned to either group I, which received saline solution (6 dogs), or group II, which received prostacyclin. Group I was referred to as the control group and group II as the iloprost group. After baseline measurements were completed, the aorta was cross-clamped for sixty minutes distal to the left subclavian artery. No pharmacologic agents were used to control blood pressure in group I. Proximal and distal mean arterial pressures (DMAP) were monitored continuously. DMAP were considered as diastolic pressure in preocclusion and reperfusion periods. Iloprost administration was started at a rate of 5 ng/kg/minute five minutes before the aortic occlusion. This dosage was increased to 25 ng/kg/minute during aortic occlusion. RESULTS: Mean proximal arterial pressure was 147+/-12 mmHg in the control group and 116+/-13 mmHg in the iloprost group at occlusion (p<0.01). Mean distal arterial pressure was 19+/-7 in the control group and 37+/-5 in the iloprost group during clamping (p<0.05). Functional outcome was evaluated according to Tarlov scores 24 hours after the study. Although none of the animals recovered completely from the control group, 4 animals from the iloprost group recovered (p<0.05). Following the neurologic assessment, animals were sacrificed and specimens were taken for the electron microscopic study. Electron microscopic changes documented that severe mitochondrial damage and vacuolisation occurred in the control group. However these changes were more subtle in the iloprost group. CONCLUSIONS: As a result of this study we concluded that iloprost infused before and during clamping of the thoracic aorta mitigates the spinal cord injury due to ischemia and reperfusion following unclamping.


Subject(s)
Aorta, Abdominal/surgery , Iloprost/pharmacology , Ischemia/prevention & control , Spinal Cord/blood supply , Vasodilator Agents/pharmacology , Animals , Blood Pressure/physiology , Dogs , Dose-Response Relationship, Drug , Ischemia/pathology , Ischemia/physiopathology , Microscopy, Electron , Myelin Sheath/pathology , Reperfusion Injury/pathology , Reperfusion Injury/physiopathology , Reperfusion Injury/prevention & control , Spinal Cord/pathology
15.
Eur J Vasc Endovasc Surg ; 19(5): 456-60, 2000 May.
Article in English | MEDLINE | ID: mdl-10828224

ABSTRACT

OBJECTIVES: to evaluate the efficacy of single-dose pre-insertion gamma radiation of vein grafts in the prevention of intimal hyperplasia. METHODS: femoral artery interposition grafts with internal jugular vein were inserted in 12 mongrel dogs. The animals were randomly divided into two groups. Immediately before graft replacement, jugular veins were treated with a single dose of cobalt-60 radiation at 14 Gy or received no radiation (control group). Six weeks after graft insertion, the vein grafts were pressure-perfusion fixed and harvested for the histomorphometric analysis. Quantitative data on anastomotic stenosis were calculated from Gilman parameters after cross-sectional image analysis. RESULTS: vein grafts treated with radiation demonstrated significantly decreased neointima formation compared with grafts in the control group. The mean Gilman parameter for the control group was 1.09 S.E.M. 0.34 mm and for the radiotherapy group was 0.65 S.E. M. 0.23 mm (p<0.05). All vein grafts in the radiotherapy group had a decreased amount of intimal and cellular infiltration. CONCLUSION: single-dose external pre-insertion gamma radiation of vein grafts reduced the amount of intimal hyperplasia in this animal model.


Subject(s)
Graft Occlusion, Vascular/prevention & control , Jugular Veins/transplantation , Preoperative Care , Saphenous Vein/radiation effects , Tunica Intima/pathology , Animals , Arterial Occlusive Diseases/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Disease Models, Animal , Dogs , Endothelium, Vascular/pathology , Endothelium, Vascular/radiation effects , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/pathology , Hyperplasia/prevention & control , Jugular Veins/pathology , Male , Photomicrography , Preoperative Care/methods , Random Allocation , Saphenous Vein/pathology , Saphenous Vein/transplantation , Transplantation, Homologous , Treatment Outcome , Tunica Intima/radiation effects
16.
Int J Cardiol ; 73(2): 115-21, 2000 Apr 28.
Article in English | MEDLINE | ID: mdl-10817848

ABSTRACT

This study examined if the use of simplified coronary sinus retroperfusion would lead to any reduction in the infarcted area associated with improved right and left ventricular function. Twelve mongrel dogs were entered in this study. Following anesthesia, a fast response thermistor was placed on the pulmonary artery via the jugular vein and aorta via the left ventricular apex. The left anterior descending artery (LAD) was separated from the vein. A retrograde cardioplegia catheter was inserted into the coronary sinus. Following these procedures, LAD was occluded for a period of 3.5 h. After 30 min ischemia, the aorta-coronary sinus connection was established. The animals were divided into two equal groups. One group was not treated and was considered the control group (six animals). In the remaining group (six animals), retroperfusion was used and was considered the retroperfusion group. At the end of the study, the left ventricular ejection fraction was 65+/-15% in the retroperfusion group and 48+/-5% in the control group (P<0.05). The left ventricular stroke work index was 0.44+/-0.04 (g m/kg) in the retroperfusion group and 0.31+/-0.05 (g m/kg) in the control group (P<0.05). Cardiac output was 1650+/-75 ml/min in the retroperfusion group and 1250+/-125 ml/min in the control group. The ratio of the infarct size to the area at risk was 49+/-5% in the control group and 7+/-3% in the retroperfusion group. In light of these studies, we conclude that simplified coronary sinus retroperfusion appears to be an effective method that must be taken into consideration.


Subject(s)
Coronary Disease/therapy , Myocardial Infarction/therapy , Myocardial Reperfusion/methods , Animals , Cardiac Catheterization , Coronary Disease/complications , Coronary Disease/physiopathology , Coronary Vessels/surgery , Disease Models, Animal , Dogs , Electrocardiography , Hemodynamics , Myocardial Infarction/etiology , Myocardial Infarction/physiopathology , Myocardium/pathology
17.
Panminerva Med ; 42(4): 253-6, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11294087

ABSTRACT

BACKGROUND: The aim of the presented study was to evaluate the preservation effect of the pentoxyphylline-blood cardioplegia on myocardial functions during and after the cardiopulmonary bypass in an experimental dog model. METHODS: Central hemodynamics and metabolic variables such as creatine phosphokinase, myocardial oxygen extraction and myocardial lactate extraction were obtained during and following 4 hours after the cardiopulmonary bypass after the baseline scores were recorded. Twelve mongrel dogs were divided into two equal groups. The first group of animals served as controls. The second group of animals was treated with pentoxyphylline cardioplegia that was added to each blood cardioplegia as 15 mg/100 ml. RESULTS: After bypass, the hemodynamic parameters were better in the pentoxyphylline group. Cardiac index fell in all animals, but it was significantly less in the control group. Pulmonary capillary wedge pressure was lower in the pentoxyphylline group as an index of better preservation of ventricular filling pressure. CPK-MB was significantly higher in the control group both at 2 and 4 hours after the bypass. It was 79 +/- 13 iu/L in the control group and 41 +/- 9 iu/L in the pentoxyphylline group 4 hours after cardiopulmonary bypass. MLE was also higher both on bypass and following bypass in the control group. CONCLUSIONS: In conclusion, pentoxyphylline usage may reduce the risks of ischemic-reperfusion injury during and following cardiopulmonary bypass and aortic cross-clamping. It can be an administered drug during cardioplegia.


Subject(s)
Cardiopulmonary Bypass , Heart Arrest, Induced , Heart/drug effects , Pentoxifylline/pharmacology , Animals , Dogs , Heart/physiopathology , Hemodynamics/drug effects , Myocardial Reperfusion Injury/prevention & control
18.
Angiology ; 50(11): 929-35, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10580358

ABSTRACT

Twelve animals (26+/-5 kg) were subjected to the study. In this experimental study, the authors used prostacyclin to inhibit the toxic metabolite release during protamine administration. Animals were divided into two equal groups. Six animals received prostacyclin (the prostacyclin group), and the other six animals did not receive any additional treatment (the control group). All cardiac output and biochemical measurements were evaluated at baseline; before cardiopulmonary bypass; and at 5, 30, and 60 minutes after protamine administration. The measured cardiac index showed that the hearts treated with prostacyclin had satisfactory preservation of left ventricular function. Metabolic and biochemical data showed that the tumor necrosis factor level was raised significantly in the control group (20.75+/-2.2 in the control group and 13.75+/-2.5 pg/mL in the prostacyclin group). Also, E and P selectin levels were elevated in the control group, but this change was less marked in the prostacyclin group. In addition, the intracellular adhesion molecule-1 (ICAM-1) level was significantly higher in the control group than in the prostacyclin group (9.26+/-2.13 in the control group and 5.13+/-1.66 ng/mL in the prostacyclin group). The authors observed that prostacyclin inhibited the toxic mediator release during heparin reversal with protamine. This inhibition is one way of protecting the myocardium reserves from protamine cardiotoxicity.


Subject(s)
Epoprostenol/pharmacology , Heart/drug effects , Heparin Antagonists/toxicity , Platelet Aggregation Inhibitors/pharmacology , Protamines/antagonists & inhibitors , Animals , Dogs , E-Selectin/metabolism , Enzyme-Linked Immunosorbent Assay , Intercellular Adhesion Molecule-1/metabolism , P-Selectin/metabolism , Protamines/toxicity , Tumor Necrosis Factor-alpha/metabolism
19.
J Cardiovasc Surg (Torino) ; 40(4): 495-9, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10532205

ABSTRACT

BACKGROUND: In this experimental study we investigate the effect of intravenous ATP-MgCl**2 administration for prevention of spinal cord injury occurring due to ischemia induced by aortic cross clamping. METHODS: Ten rabbits were studied. The abdominal aorta is ligated below the left renal artery. Five rabbits served as a control group and received no medication during 30 minutes of ischemic period. The other 5 rabbits received during 30 minutes of aortic occlusion ATP-MgCl2 solution (100 micromol/ml for each). Distal and proximal aortic pressures are measured during the procedure and incisions are closed. Rabbits are observed for 24 hours for their neurological status and scored accordingly. Specimens from the spinal cord are taken for electron microscopic investigations. RESULTS: All of the control group rabbits were paraplegic. One of the ATP-MgCl2 group rabbits was paraparesic and the others were normal Distal aortic pressure was 9+/-3 mmHg for the control group and was 17+/-4 mmHg for the ATP-MgCl2 group (p<0.05). Electron microscopic studies showed the preserved ultrastructure for ATP-MgCl2 group. CONCLUSIONS: ATP-MgCl2 administration during spinal cord ischemia reduces spinal cord injury. This may be an alternative modality for the protection of the spinal cord during aortic surgery.


Subject(s)
Adenosine Triphosphate/pharmacology , Aorta, Thoracic/surgery , Ischemia/prevention & control , Spinal Cord/blood supply , Animals , Infusions, Intravenous , Ischemia/pathology , Ligation , Microscopy, Electron , Neurologic Examination/drug effects , Rabbits , Spinal Cord/pathology
20.
J Cardiovasc Surg (Torino) ; 40(4): 573-5, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10532222

ABSTRACT

BACKGROUND: Protection of the brain is of vital importance during aortic arch aneurysms. In this study efficiency of retrograde cerebral perfusion was evaluated with the use of single photon emission computed tomography technique (SPECT) by using 99mTc hexamethylpropylene amine oxime (HMPAO). METHODS: Four animals were used. The internal maxillary vein was the site of retrograde cerebral perfusion. The animals were studied after the heart rate and respiration were stopped with the use of the high dose drug administration and the brain was perfused with cold Ringer's lactated solution. After this procedure, 99mTc HMPAO-SPECT study was performed. RESULTS: In one animal we did not get any cerebral image because of the competent venous valve in the internal maxillary vein. In the remaining animals, normal brain perfusion was achieved. CONCLUSIONS: 99mTc HMPAO-SPECT study documented that blood flow via the retrograde way meets the metabolic demand of the brain. Retrograde delivery of 99mTc HMPAO did not conclude any poorly perfused area in the brain when in given both sides and all parts of the brain can be effectively perfused by cerebral venous system in hypothermic conditions.


Subject(s)
Brain/blood supply , Heart Arrest, Induced , Tomography, Emission-Computed, Single-Photon , Animals , Aortic Aneurysm, Thoracic/surgery , Cerebral Veins/diagnostic imaging , Dogs , Regional Blood Flow/physiology , Technetium Tc 99m Exametazime
SELECTION OF CITATIONS
SEARCH DETAIL
...