1.
Phys Rev Lett ; 126(13): 131103, 2021 Apr 02.
Article in English | MEDLINE | ID: mdl-33861094

ABSTRACT

We report on the first subpicometer interferometer flown in space. It was part of ESA's Laser Interferometer Space Antenna (LISA) Pathfinder mission and performed the fundamental measurement of the positional and angular motion of two free-falling test masses. The interferometer worked immediately, stably, and reliably from switch on until the end of the mission with exceptionally low residual noise of 32.0_{-1.7}^{+2.4} fm/sqrt[Hz], significantly better than required. We present an upper limit for the sensor performance at millihertz frequencies and a model for the measured sensitivity above 200 mHz.

2.
Rev Sci Instrum ; 91(4): 045003, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32357757

ABSTRACT

The Laser Interferometer Space Antenna Pathfinder (LPF) main observable, labeled Δg, is the differential force per unit mass acting on the two test masses under free fall conditions after the contribution of all non-gravitational forces has been compensated. At low frequencies, the differential force is compensated by an applied electrostatic actuation force, which then must be subtracted from the measured acceleration to obtain Δg. Any inaccuracy in the actuation force contaminates the residual acceleration. This study investigates the accuracy of the electrostatic actuation system and its impact on the LPF main observable. It is shown that the inaccuracy is mainly caused by the rounding errors in the waveform processing and also by the random error caused by the analog to digital converter random noise in the control loop. Both errors are one order of magnitude smaller than the resolution of the commanded voltages. We developed a simulator based on the LPF design to compute the close-to-reality actuation voltages and, consequently, the resulting actuation forces. The simulator is applied during post-processing the LPF data.

3.
Phys Rev Lett ; 123(11): 111101, 2019 Sep 13.
Article in English | MEDLINE | ID: mdl-31573236

ABSTRACT

We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.

4.
Phys Rev Lett ; 120(6): 061101, 2018 Feb 09.
Article in English | MEDLINE | ID: mdl-29481269

ABSTRACT

In the months since the publication of the first results, the noise performance of LISA Pathfinder has improved because of reduced Brownian noise due to the continued decrease in pressure around the test masses, from a better correction of noninertial effects, and from a better calibration of the electrostatic force actuation. In addition, the availability of numerous long noise measurement runs, during which no perturbation is purposely applied to the test masses, has allowed the measurement of noise with good statistics down to 20 µHz. The Letter presents the measured differential acceleration noise figure, which is at (1.74±0.05) fm s^{-2}/sqrt[Hz] above 2 mHz and (6±1)×10 fm s^{-2}/sqrt[Hz] at 20 µHz, and discusses the physical sources for the measured noise. This performance provides an experimental benchmark demonstrating the ability to realize the low-frequency science potential of the LISA mission, recently selected by the European Space Agency.

5.
Phys Rev Lett ; 118(17): 171101, 2017 Apr 28.
Article in English | MEDLINE | ID: mdl-28498710

ABSTRACT

We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0 fm s^{-2} Hz^{-1/2} across the 0.1-100 mHz frequency band that is crucial to an observatory such as the Laser Interferometer Space Antenna (LISA). Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge buildup due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.

6.
Neurosurgery ; 28(6): 814-20, 1991 Jun.
Article in English | MEDLINE | ID: mdl-2067602

ABSTRACT

Thirty-six patients with acute spontaneous subarachnoid hemorrhage (26 caused by rupture of an aneurysm) were examined by transcranial color-coded real-time sonography by using a 2.25-MHz ultrasound transducer. In 20 of these 26 patients (76%), the aneurysm could be identified by a characteristic abnormal blood flow pattern within the aneurysm in coronal and axial scanning planes by transcranial color-coded real-time sonography. Blood within the basal cisterns, on top of the tentorium, and within the ventricles and parenchyma was sonographically detected by increased echodensity in 75%. In addition, cerebrospinal fluid circulation disturbances and cerebral vasospasm were detected in two-dimensional B-mode images in 85% and 100%, respectively. In Doppler mode, intravascular blood flow velocity could be quantified. We conclude that transcranial color-coded real-time sonography, a new, noninvasive method for diagnosis and follow-up of patients with subarachnoid hemorrhage, allows detection of the primary vascular lesion and monitoring of complications.


Subject(s)
Subarachnoid Hemorrhage/diagnostic imaging , Blood Flow Velocity , Brain Edema/diagnostic imaging , Brain Edema/etiology , Brain Ischemia/diagnostic imaging , Brain Ischemia/etiology , Cerebrovascular Circulation , Color , Female , Follow-Up Studies , Humans , Hydrocephalus/diagnostic imaging , Hydrocephalus/etiology , Intracranial Aneurysm/complications , Intracranial Aneurysm/diagnostic imaging , Ischemic Attack, Transient/diagnostic imaging , Ischemic Attack, Transient/etiology , Male , Middle Aged , Monitoring, Physiologic , Rupture, Spontaneous , Subarachnoid Hemorrhage/complications , Tomography, X-Ray Computed , Ultrasonography