Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Bioanalysis ; 16(6): 389-402, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38334082

ABSTRACT

Validation of biomarker assays is crucial for effective drug development and clinical applications. Interlaboratory reproducibility is vital for reliable comparison and combination of data from different centers. This review summarizes interlaboratory studies of quantitative LC-MS-based biomarker assays using reference standards for calibration curves. The following points are discussed: trends in reports, reference and internal standards, evaluation of analytical validation parameters, study sample analysis and normalization of biomarker assay data. Full evaluation of these parameters in interlaboratory studies is limited, necessitating further research. Some reports suggest methods to address variations in biomarker assay data among laboratories, facilitating organized studies and data combination. Method validation across laboratories is crucial for reducing interlaboratory differences and reflecting target biomarker responses.


Subject(s)
Liquid Chromatography-Mass Spectrometry , Tandem Mass Spectrometry , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Reproducibility of Results , Reference Standards
2.
Bioanalysis ; 14(18): 1213-1227, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36408704

ABSTRACT

Background: Many bioanalytical methods for antisense oligonucleotides (ASOs) using LC-MS have been reported. However, no data have been available on the reproducibility and robustness of a single bioanalytical method for ASOs. As such, in the current study, we evaluated the reproducibility and robustness of LC-MS-based bioanalytical methods for ASOs in multiple laboratories. Methods/Results: Seven independent laboratories were included in this study. Mipomersen was measured by ion-pairing LC-MS (IP-LC-MS) as a model ASO using different LC-MS. The validation results of calibration curve, accuracy, precision and selectivity met the criteria of conventional bioanalytical method validation guidelines using LC/GC-MS for drugs in all laboratories. Meanwhile, carryover (>20%) was detected in three laboratories. Conclusion: We first demonstrated the multicenter-validated IP-LC-MS bioanalytical method for ASOs. Our data showed that the method was sensitive, robust and reproducible. However, the occurrence of carryover should be carefully monitored in its future application.


Subject(s)
Biological Therapy , Tandem Mass Spectrometry , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Reproducibility of Results , Calibration
3.
Bioanalysis ; 13(20): 1533-1546, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34696608

ABSTRACT

Aim: Although the fit-for-purpose approach has been proposed for validation procedures and acceptance criteria for biomarker assays, practical biomarker assays to facilitate clinical application and regulatory documents on biomarker assays remain limited. Materials & methods: We assigned six independent laboratories and selected three lysophosphatidylcholines (LPCs): LPC(16:0), LPC(18:0) and LPC(18:1) as model biomarkers. Using LC-MS, the following key validation parameters were evaluated: calibration curve, carryover, parallelism, precision and relative accuracy and these values were similar among all laboratories. Further, we determined LPC levels in six lots of rat plasma at unknown concentrations and compared them among the laboratories. Conclusion: Our multilaboratory validation and reproducibility data are useful for the development of future biomarker assay validation procedures, as well as regulatory documents.


Subject(s)
Lysophosphatidylcholines
4.
Xenobiotica ; 51(5): 590-604, 2021 May.
Article in English | MEDLINE | ID: mdl-33685346

ABSTRACT

The pharmacokinetics of brexpiprazole were investigated in the in vitro and in vivo.The total body clearance of brexpiprazole in rat and monkey was 2.32 and 0.326 L/h/kg, respectively, after intravenous administration, and oral availability was 13.6% and 31.0%, respectively. Dose-dependent exposures were observed at dose ranges between 1-30 mg/kg in the rat and 0.1-3 mg/kg in the monkey.Brexpiprazole distributed widely to body tissues, and Vd,z were 2.81 and 1.82 L/kg in rat and monkey, respectively. The serum protein binding of brexpiprazole was 99% or more in animals and human. Uniform distribution character among the species was suggested by a traditional animal scale-up method.A common main metabolite, DM-3411 was found in animals and humans in the metabolic reactions with the liver S9 fraction. CYP3A4 and CYP2D6 were predominantly involved in the metabolism.The affinity of DM-3411 for D2 receptors was lower than that of brexpiprazole, and neither DM-3411 nor any metabolites with affinity other than M3 were detected in the brain, demonstrating that brexpiprazole is only involved in the pharmacological effects.Overall, brexpiprazole has a simple pharmacokinetic profile with good metabolic stability, linear kinetics, and no remarkable species differences with regard to metabolism and tissue distribution.


Subject(s)
Dopamine , Quinolones , Animals , Haplorhini , Humans , Rats , Serotonin , Thiophenes
5.
Bioanalysis ; 13(4): 265-276, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33543661

ABSTRACT

Aim: We aimed to develop an easy, low-cost and versatile mass spectrometric method for the bioanalysis of a therapeutic monoclonal antibody (mAb) in human serum that employs peptide adsorption-controlled (PAC)-LC/MS using selected reaction monitoring mode (LC-MS/MS-SRM). Materials & methods: Rituximab was used as a model mAb. To apply the method to human serum samples, a peptide of the complementarity-determining region was selected as the surrogate peptide. The usefulness of PAC-LC-MS/MS-SRM was evaluated by a collaborative study. Results: The calibration curve ranged from 0.5 (or 1.0) to 1000.0 µg/ml. The selectivity, linearity, accuracy and precision met the predefined acceptance criteria. Conclusion: Our method could be a useful bioanalytical method for the quantification of mAbs in clinical samples.


Subject(s)
Antibodies, Monoclonal/blood , Biological Assay/methods , Chromatography, Liquid/methods , Peptides/metabolism , Tandem Mass Spectrometry/methods , Humans
6.
Bioanalysis ; 12(24): 1739-1756, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33242248

ABSTRACT

Background: Ion-pairing reverse-phase LC coupled with high-resolution mass spectrometry (IP-LC/HRMS) has gained attention in oligonucleotide therapeutic bioanalyses owing to its high sensitivity and selectivity. However, optimization and validation of IP-LC/HRMS-based methods are rare. The objective of this study is the development of a sensitive and reproducible IP-LC/HRMS-based bioanalytical method using clinically approved mipomersen as a model for antisense oligonucleotides. Materials & methods/results: Mipomersen was extracted from rat plasma using Clarity OTX SPE and quantified by IP-LC/HRMS. The calibration range was 0.5-250.0 ng/ml. The developed method met the general regulatory criteria for accuracy, precision, carry-over, selectivity, matrix effect and dilution integrity. Conclusion: A highly sensitive and reliable method for mipomersen measurement with potential antisense oligonucleotide bioanalysis applications has been developed.


Subject(s)
Biological Therapy/methods , Chromatography, Liquid/methods , DNA, Antisense/metabolism , Mass Spectrometry/methods , Oligonucleotides/metabolism , Calibration , Humans
7.
Drug Chem Toxicol ; 32(3): 204-14, 2009.
Article in English | MEDLINE | ID: mdl-19538016

ABSTRACT

Previously, we showed that the toxic susceptibility of male rats to an ultraviolet absorber, 2-(2'-hydroxy- 3',5'-di-tert-butylphenyl)benzotriazole (HDBB), was nearly 25 times higher than that of females. The present study aimed to clarify the mechanism of gender-related differences in HDBB toxicity. Male and female rats were given HDBB by gavage at 0.5, 2.5, or 12.5 mg/kg/day for 28 days, and plasma HDBB levels were measured at various time points by using liquid chromatography-tandem mass spectrometry. HDBB was rapidly absorbed and eliminated from the plasma in both sexes, and no sexual variations were found in the plasma levels. In the plasma, HDBB metabolites were not detected at any dose by the liquid chromatography-photodiode array detector. In an in vitro metabolic study using hepatic microsomes from male and female rats, HDBB was slightly metabolized, but no sexual differences were found in the residual HDBB ratio after a 60-minute incubation with an NADPH-generation system. Following 28-day HDBB administration, sexually different changes were found in cytochrome P450-dependent microsomal mixed-function oxidase activities in the liver. In males, 7-ethoxyresorufin O-deethylase activity decreased and lauric acid 12-hydroxylase activity increased at all doses. Decreases in aminopyrine N-demethylase activity and testosterone 2alpha- and 16alpha-hydroxylase activity were also found at 2.5 mg/kg and above in males. In females, the only significant change was increased lauric acid 12-hydroxylase activity at 12.5 mg/kg. These findings indicate that HDBB would have hepatic peroxisome proliferative activity, and the difference in susceptibility of male and female rats to this effect might lead to marked gender-related differences in HDBB toxicity.


Subject(s)
Liver/drug effects , Microsomes, Liver/drug effects , NADPH-Ferrihemoprotein Reductase/drug effects , Ribosomal Proteins/drug effects , Triazoles/toxicity , Administration, Oral , Animals , Body Weight/drug effects , Chromatography, High Pressure Liquid , Female , In Vitro Techniques , Liver/enzymology , Liver/pathology , Male , Microsomes, Liver/enzymology , NADPH-Ferrihemoprotein Reductase/metabolism , Rats , Rats, Sprague-Dawley , Ribosomal Protein S9 , Ribosomal Proteins/metabolism , Sex Factors , Tandem Mass Spectrometry , Toxicity Tests , Triazoles/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...