Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Nat Commun ; 10(1): 2664, 2019 06 13.
Article in English | MEDLINE | ID: mdl-31197143

ABSTRACT

Quantum information processing requires quantum registers based on coherently interacting quantum bits. The dipolar couplings between nitrogen vacancy (NV) centres with nanometre separation makes them a potential platform for room-temperature quantum registers. The fabrication of quantum registers that consist of NV centre arrays has not advanced beyond NV pairs for several years. Further scaling up of coupled NV centres by using nitrogen implantation through nanoholes has been hampered because the shortening of the separation distance is limited by the nanohole size and ion straggling. Here, we demonstrate the implantation of C5N4Hn from an adenine ion source to achieve further scaling. Because the C5N4Hn ion may be regarded as an ideal point source, the separation distance is solely determined by straggling. We successfully demonstrate the fabrication of strongly coupled triple NV centres. Our method may be extended to fabricate small quantum registers that can perform quantum information processing at room temperature.

2.
Sensors (Basel) ; 18(7)2018 Jul 06.
Article in English | MEDLINE | ID: mdl-29986461

ABSTRACT

In this paper, we report on the effect of carboxyl- and amine terminations on a boron-doped diamond surface (BDD) in relation to pH sensitivity. Carboxyl termination was achieved by anodization oxidation in Carmody buffer solution (pH 7). The carboxyl-terminated diamond surface was exposed to nitrogen radicals to generate an amine-terminated surface. The pH sensitivity of the carboxyl- and amine-terminated surfaces was measured from pH 2 to pH 12. The pH sensitivities of the carboxyl-terminated surface at low and high pH are 45 and 3 mV/pH, respectively. The pH sensitivity after amine termination is significantly higher—the pH sensitivities at low and high pH are 65 and 24 mV/pH, respectively. We find that the negatively-charged surface properties of the carboxyl-terminated surface due to ionization of ⁻COOH causes very low pH detection in the high pH region (pH 7⁻12). In the case of the amine-terminated surface, the surface properties are interchangeable in both acidic and basic solutions; therefore, we observed pH detection at both low and high pH regions. The results presented here may provide molecular-level understanding of surface properties with charged ions in pH solutions. The understanding of these surface terminations on BDD substrate may be useful to design diamond-based biosensors.

SELECTION OF CITATIONS
SEARCH DETAIL