Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38556747

ABSTRACT

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Subject(s)
Atrial Fibrillation , Cryosurgery , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cryosurgery/instrumentation , Female , Male , Middle Aged , Aged , Treatment Outcome , Heart Atria/surgery , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Action Potentials , Heart Rate , Time Factors , Retrospective Studies , Recurrence , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology
2.
Europace ; 25(4): 1400-1407, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36892146

ABSTRACT

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Kidney Failure, Chronic , Thromboembolism , Humans , Female , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Anticoagulants/adverse effects , Hemorrhage/chemically induced , Thromboembolism/etiology , Thromboembolism/prevention & control , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/therapy , Catheter Ablation/adverse effects , Registries
3.
Cardiovasc Revasc Med ; 53S: S207-S208, 2023 08.
Article in English | MEDLINE | ID: mdl-36137909

ABSTRACT

Balloon-Assisted Ultrasound-Guided Percutaneous Thrombin Injection (BATI) is useful for iatrogenic pseudoaneurysm. In previous reports, BATI for pseudoaneurysm of the femoral artery was performed by contralateral transfemoral approach. It has been reported that patients with obesity, hypertension, and diabetes have more hemorrhagic complications at the puncture site of the femoral artery. We report a case in which BATI by transradial artery approach was useful for patients with obesity, hypertension, and diabetes who were expected to be at high risk of hemorrhagic complications of transfemoral artery approach.


Subject(s)
Aneurysm, False , Diabetes Mellitus , Hypertension , Humans , Thrombin , Femoral Artery/diagnostic imaging , Aneurysm, False/diagnostic imaging , Aneurysm, False/drug therapy , Aneurysm, False/etiology , Hypertension/complications , Obesity/complications , Ultrasonography, Interventional
4.
Cardiol Ther ; 11(3): 433-444, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35729308

ABSTRACT

INTRODUCTION: Few researchers have investigated the optimal long-term antithrombotic therapy regimen, especially after first-generation drug-eluting stent (DES) use. This study aimed to evaluate the impact of mid-term antithrombotic therapy on long-term outcomes in patients treated with the first sirolimus-eluting coronary stent (Cypher™). METHODS: Between 2004 and 2009, 1021 patients underwent Cypher™ implantation at our institute; among them, 567 patients had available data on antithrombotic therapy at year 5. We assessed patients' antithrombotic therapy at year 5 post Cypher™ implantation and examined their association with adverse events from year 5 to year 10 post Cypher™ implantation. RESULTS: Patients with dual-antiplatelet therapy (DAPT) at year 5 had significantly lower risk of stent thrombosis (ST) than those with single-antiplatelet therapy (SAPT) (hazard ratio [HR] 0.24, p = 0.034). The HR of major bleeding in DAPT, compared to SAPT, was high, but the difference was not significant (HR 1.72, p = 0.26). Risk of major bleeding was significantly higher in patients on oral anticoagulants (OAC) than in those in other groups (OAC/SAPT; HR 5.31, p = 0.0048, OAC/DAPT; HR 3.08, p = 0.022), without significant reduction in the risk of cardiovascular events. CONCLUSIONS: The incidence of ST after Cypher™ implantation in patients with DAPT at year 5 was significantly lower than that in SAPT. However, the risk of bleeding was higher with DAPT than with SAPT. Moreover, the risk of major bleeding was significantly higher in patients on anticoagulant therapy than in other patients. New options for the use of antithrombotic drugs after percutaneous coronary intervention warrant further studies on the optimal antithrombotic therapy for first-generation DES.

SELECTION OF CITATIONS
SEARCH DETAIL
...