Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Minim Invasive Gynecol ; 25(3): 447-454, 2018.
Article in English | MEDLINE | ID: mdl-29030291

ABSTRACT

STUDY OBJECTIVE: To establish a porcine uterine horn adhesion model that mimicked laparoscopic procedures and use it to investigate the effect of a spray-type, novel dextrin hydrogel adhesion barrier (AdSpray; Terumo Corporation, Tokyo, Japan) on postsurgical adhesions. DESIGN: A single-blind randomized controlled trial (Canadian Task Force Classification I). SETTING: A Certified animal research facility. SUBJECTS: Sixteen female pigs. INTERVENTIONS: All animals underwent laparoscopically assisted adhesion-inducing surgery. The uterine horns and the peritoneum of the pelvic sidewall were injured. In the experimental group, AdSpray was applied to the injured site, and the handling of the sprayer was assessed. At 28 ± 1 days after surgery, animals were sacrificed, and adhesions at the injured site were evaluated. Uterine horn suture sites were examined under a light microscope to assess healing of the incised wound, the inflammatory reaction, abscess, and the foreign body reaction to the surgical suture. MEASUREMENTS AND MAIN RESULTS: The control group showed severe adhesions over the entire surface interface at the uterine horn suture sites and peritoneal resection site. Compared with the control treatment, AdSpray exhibited a higher percentage of adhesion-free sites (p < .001) and reduced the total adhesion score (p < .001). In the AdSpray group, no inflammation or abscess formation was observed on histopathological examination, and ideal healing of the suture sites was confirmed in all cases. CONCLUSION: Based on the results of the present study, the novel dextrin hydrogel shows excellent adhesion prevention and can be easily applied during laparoscopy using a dedicated sprayer.


Subject(s)
Dextrins/pharmacology , Laparoscopy/methods , Tissue Adhesions/surgery , Uterus/surgery , Animals , Dextrins/administration & dosage , Female , Foreign-Body Reaction/pathology , Hydrogels/administration & dosage , Japan , Occlusive Dressings , Peritoneum/pathology , Postoperative Complications/surgery , Random Allocation , Single-Blind Method , Sutures , Swine
2.
Proc Natl Acad Sci U S A ; 108(33): 13399-403, 2011 Aug 16.
Article in English | MEDLINE | ID: mdl-21808049

ABSTRACT

The use of fluorescence-based sensors holds great promise for continuous glucose monitoring (CGM) in vivo, allowing wireless transdermal transmission and long-lasting functionality in vivo. The ability to monitor glucose concentrations in vivo over the long term enables the sensors to be implanted and replaced less often, thereby bringing CGM closer to practical implementation. However, the full potential of long-term in vivo glucose monitoring has yet to be realized because current fluorescence-based sensors cannot remain at an implantation site and respond to blood glucose concentrations over an extended period. Here, we present a long-term in vivo glucose monitoring method using glucose-responsive fluorescent hydrogel fibers. We fabricated glucose-responsive fluorescent hydrogels in a fibrous structure because this structure enables the sensors to remain at the implantation site for a long period. Moreover, these fibers allow easy control of the amount of fluorescent sensors implanted, simply by cutting the fibers to the desired length, and facilitate sensor removal from the implantation site after use. We found that the polyethylene glycol (PEG)-bonded polyacrylamide (PAM) hydrogel fibers reduced inflammation compared with PAM hydrogel fibers, transdermally glowed, and continuously responded to blood glucose concentration changes for up to 140 days, showing their potential application for long-term in vivo continuous glucose monitoring.


Subject(s)
Blood Glucose/analysis , Fluorescence , Hydrogels , Monitoring, Physiologic/methods , Acrylic Resins , Animals , Hydrogels/chemistry , Inflammation/prevention & control , Male , Mice , Polyethylene Glycols , Prostheses and Implants
3.
Proc Natl Acad Sci U S A ; 107(42): 17894-8, 2010 Oct 19.
Article in English | MEDLINE | ID: mdl-20921374

ABSTRACT

Fluorescent microbeads hold great promise for in vivo continuous glucose monitoring with wireless transdermal transmission and long-lasting activity. The full potential of fluorescent microbeads has yet to be realized due to insufficient intensity for transdermal transmission and material toxicity. This paper illustrates the highly-sensitive, biostable, long-lasting, and injectable fluorescent microbeads for in vivo continuous glucose monitoring. We synthesized a fluorescent monomer composed of glucose-recognition sites, a fluorogenic site, spacers, and polymerization sites. The spacers are designed to be long and hydrophilic for increasing opportunities to bind glucose molecules; consequently, the fluorescent monomers enable high-intensive responsiveness to glucose. We then fabricated injectable-sized fluorescent polyacrylamide hydrogel beads with high uniformity and high throughput. We found that our fluorescent beads provide sufficient intensity to transdermally monitor glucose concentrations in vivo. The fluorescence intensity successfully traced the blood glucose concentration fluctuation, indicating our method has potential uses in highly-sensitive and minimally invasive continuous blood glucose monitoring.


Subject(s)
Blood Glucose/analysis , Hydrogels , Fluorescence , Humans , Microspheres
SELECTION OF CITATIONS
SEARCH DETAIL
...