Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Environ Microbiome ; 18(1): 34, 2023 Apr 18.
Article in English | MEDLINE | ID: mdl-37072776

ABSTRACT

BACKGROUND: We aimed to identify bacteria able to grow in the presence of several antibiotics including the ultra-broad-spectrum antibiotic meropenem in a British agricultural soil by combining DNA stable isotope probing (SIP) with high throughput sequencing. Soil was incubated with cefotaxime, meropenem, ciprofloxacin and trimethoprim in 18O-water. Metagenomes and the V4 region of the 16S rRNA gene from the labelled "heavy" and the unlabelled "light" SIP fractions were sequenced. RESULTS: An increase of the 16S rRNA copy numbers in the "heavy" fractions of the treatments with 18O-water compared with their controls was detected. The treatments resulted in differences in the community composition of bacteria. Members of the phyla Acidobacteriota (formally Acidobacteria) were highly abundant after two days of incubation with antibiotics. Pseudomonadota (formally Proteobacteria) including Stenotrophomonas were prominent after four days of incubation. Furthermore, a metagenome-assembled genome (MAG-1) from the genus Stenotrophomonas (90.7% complete) was retrieved from the heavy fraction. Finally, 11 antimicrobial resistance genes (ARGs) were identified in the unbinned-assembled heavy fractions, and 10 ARGs were identified in MAG-1. In comparison, only two ARGs from the unbinned-assembled light fractions were identified. CONCLUSIONS: The results indicate that both non-pathogenic soil-dwelling bacteria as well as potential clinical pathogens are present in this agricultural soil and several ARGs were identified from the labelled communities, but it is still unclear if horizontal gene transfer between these groups can occur.

2.
Microbiol Spectr ; 10(2): e0213721, 2022 04 27.
Article in English | MEDLINE | ID: mdl-35357242

ABSTRACT

The emergence of biofilms on dry hospital surfaces has led to the development of numerous models designed to challenge the efficacious properties of common antimicrobial agents used in cleaning. This is in spite of limited research defining how dry surfaces are able to facilitate biofilm growth and formation in such desiccating and nutrient-deprived environments. While it is well established that the phenotypical response of biofilms is dependent on the conditions in which they are formed, most models incorporate a nutrient-enriched, hydrated environment dissimilar to the clinical setting. In this study, we piloted a novel culture medium, artificial human sweat (AHS), which is perceived to be more indicative of the nutrient sources available on hospital surfaces, particularly those in close proximity to patients. AHS was capable of sustaining the proliferation of four clinically relevant multidrug-resistant pathogens (Acinetobacter baumannii, Staphylococcus aureus, Enterococcus faecalis, and Pseudomonas aeruginosa) and achieved biofilm formation at concentration levels equivalent to those found in situ (average, 6.00 log10 CFU/cm2) with similar visual characteristics upon microscopy. The AHS model presented here could be used for downstream applications, including efficacy testing of hospital cleaning products, due to its resemblance to clinical biofilms on dry surfaces. This may contribute to a better understanding of the true impact these products have on surface hygiene. IMPORTANCE Precise modeling of dry surface biofilms in hospitals is critical for understanding their role in hospital-acquired infection transmission and surface contamination. Using a representative culture condition which includes a nutrient source is key to developing a phenotypically accurate biofilm community. This will enable accurate laboratory testing of cleaning products and their efficacy against dry surface biofilms.


Subject(s)
Acinetobacter baumannii , Sweat , Biofilms , Hospitals , Humans , Staphylococcus aureus/physiology
3.
mBio ; 12(5): e0228121, 2021 10 26.
Article in English | MEDLINE | ID: mdl-34544274

ABSTRACT

Many of the most common disinfectant and sanitizer products are formulations of multiple antimicrobial compounds. Products claiming to contain synergistic formulations are common, although there is often little supporting evidence. The antimicrobial interactions of all pairwise combinations of common disinfectants (benzalkonium chloride, didecyldimethylammonium chloride, polyhexamethylene biguanide, chlorocresol, and bronopol) were classified via checkerboard assay and validated by time-kill analyses. Combinations were tested against Acinetobacter baumannii NCTC 12156, Enterococcus faecalis NCTC 13379, Klebsiella pneumoniae NCTC 13443, and Staphylococcus aureus NCTC 13143. Synergistic interactions were identified only for the combinations of chlorocresol with benzalkonium chloride and chlorocresol with polyhexamethylene biguanide. Synergism was not ubiquitously demonstrated against all species tested and was on the borderline of the synergism threshold. These data demonstrate that synergism between disinfectants is uncommon and circumstantial. Most of the antimicrobial interactions tested were characterized as additive. We suggest that this is due to the broad, nonspecific mechanisms associated with disinfectants not providing an opportunity for the combined activities of these compounds to exceed the sum of their parts. IMPORTANCE The scarcity of observed synergistic interactions suggests that in the case of many disinfectant-based products, combined mechanisms of interaction may be being misinterpreted. We emphasize the need to correctly differentiate between additivity and synergism in antimicrobial formulations, as inappropriate classification may lead to unnecessary issues in the event of regulatory changes. Furthermore, we question the need to focus on synergism and disregard additivity when considering combinations of disinfectants, as the benefits that synergistic interactions provide are not necessarily relevant to the application of the final product.


Subject(s)
Benzalkonium Compounds/pharmacology , Biguanides/pharmacology , Cresols/pharmacology , Disinfectants/pharmacology , Propylene Glycols/pharmacology , Quaternary Ammonium Compounds/pharmacokinetics , Acinetobacter baumannii/drug effects , Acinetobacter baumannii/growth & development , Drug Synergism , Enterococcus faecalis/drug effects , Enterococcus faecalis/growth & development , Klebsiella pneumoniae/drug effects , Klebsiella pneumoniae/growth & development , Microbial Sensitivity Tests , Quaternary Ammonium Compounds/pharmacology , Staphylococcus aureus/drug effects , Staphylococcus aureus/growth & development
4.
mBio ; 12(2)2021 03 23.
Article in English | MEDLINE | ID: mdl-33758085

ABSTRACT

Catheter-associated urinary tract infections have serious consequences, for both patients and health care resources. Much work has been carried out to develop an antimicrobial catheter. Although such developments have shown promise under laboratory conditions, none have demonstrated a clear advantage in clinical trials. Using a range of microbiological and advanced microscopy techniques, a detailed laboratory study comparing biofilm development on silicone, hydrogel latex, and silver alloy-coated hydrogel latex catheters was carried out. Biofilm development by Escherichia coli, Pseudomonas aeruginosa, and Proteus mirabilis on three commercially available catheters was tracked over time. Samples were examined with episcopic differential interference contrast (EDIC) microscopy, culture analysis, and staining techniques to quantify viable but nonculturable (VBNC) bacteria. Both qualitative and quantitative assessments found biofilms to develop rapidly on all three materials. EDIC microscopy revealed the rough surface topography of the materials. Differences between culture counts and quantification of total and dead cells demonstrated the presence of VBNC populations, where bacteria retain viability but are not metabolically active. The use of nonculture-based techniques showed the development of widespread VBNC populations. These VBNC populations were more evident on silver alloy-coated hydrogel latex catheters, indicating a bacteriostatic effect at best. The laboratory tests reported here, which detect VBNC bacteria, allow more rigorous assessment of antimicrobial catheters, explaining why there is often minimal benefit to patients.IMPORTANCE Several antimicrobial urinary catheter materials have been developed, but, although laboratory studies may show a benefit, none have significantly improved clinical outcomes. The use of poorly designed laboratory testing and lack of consideration of the impact of VBNC populations may be responsible. While the presence of VBNC populations is becoming more widely reported, there remains a lack of understanding of the clinical impact or influence of exposure to antimicrobial products. This is the first study to investigate the impact of antimicrobial surface materials and the appearance of VBNC populations. This demonstrates how improved testing is needed before clinical trials are initiated.


Subject(s)
Bacteria/growth & development , Biofilms/growth & development , Microbial Viability , Urinary Catheters/microbiology , Anti-Bacterial Agents/pharmacology , Bacteria/classification , Bacteria/isolation & purification , Colony Count, Microbial , Escherichia coli/growth & development , Hydrogels , Latex , Proteus mirabilis/growth & development , Pseudomonas aeruginosa/growth & development , Silicones , Surface Properties/drug effects
5.
Neurourol Urodyn ; 39(3): 907-915, 2020 03.
Article in English | MEDLINE | ID: mdl-32207551

ABSTRACT

AIMS: To determine a safe bactericidal cleaning method that does not damage urethral catheters used for intermittent catheterization. In some countries, single-use catheters are the norm; in others, the reuse of catheters is common depending on health insurance, personal preference, or individual concerns about the environment. However, no recent study of cleaning methods has been published to provide evidence for the safe reuse of catheters. METHODS: Using advanced microbiological methods, a laboratory study of eight cleaning methods was conducted. Sections of uncoated polyvinylchloride (PVC) catheters were exposed to bacterial uropathogens in physiologically correct artificial urine media then tested with a range of heat, chemical, and mechanical cleaning methods. Analysis of culturable and viable but nonculturable (VBNC) bacteria was done and direct microscopy was used. Descriptive statistics were used to compare values. RESULTS: Heat treatments, although effective, resulted in catheter surface breakdown and damage. Ultrasonic cleaning and vinegar showed evidence of VBNC populations indicating the methods were bacteriostatic. Detergent and water wash followed by immersion in a commercially available 0.6% sodium hypochlorite solution and 16.5% sodium chloride (diluted Milton) gave consistent bactericidal results and no visible catheter damage. CONCLUSIONS: Combined mechanical and chemical treatment of a detergent and water wash followed by immersion in diluted Milton (the "Milton Method") provided consistent and effective cleaning of uncoated PVC catheters, showing bactericidal action for all uropathogens tested after repeated exposure. If found safe in clinical testing, this method could increase the reuse of catheters, reduce plastic waste in the environment, reduce cost, and increase patient choice.


Subject(s)
Anti-Bacterial Agents , Detergents , Disinfectants , Disinfection/methods , Equipment Reuse , Hot Temperature , Intermittent Urethral Catheterization/instrumentation , Polyvinyl Chloride , Urinary Catheters/microbiology , Acetic Acid , Evidence-Based Practice , Humans , In Vitro Techniques , Materials Testing , Microbial Viability , Microwaves , Sodium Chloride , Sodium Hypochlorite , Steam , Ultrasonic Waves
6.
Sci Rep ; 8(1): 8172, 2018 05 25.
Article in English | MEDLINE | ID: mdl-29802355

ABSTRACT

Release of metal ions from metal-based surfaces has been considered one of the main drivers of their antimicrobial activity. Here we describe a method that enables parallel assessment of metal ion release from solid metallic surfaces and antimicrobial efficacy of these surfaces in a short time period. The protocol involves placement of a small volume of bioluminescent bacteria onto the tested surface and direct measurement of bioluminescence at various time points. In this study, two recombinant Escherichia coli strains, one expressing bioluminescence constitutively and applicable for general antimicrobial testing, and the other induced by Cu ions, were selected. Decrease in bioluminescence of constitutive E. coli on the surfaces showed a good correlation with the decrease in bacterial viability. Response of Cu-inducible E. coli showed a correlation with Cu content in the tested surfaces but not with Cu dissolution suggesting the role of direct bacteria-surface contact in Cu ion-driven antibacterial effects. In summary, the presented protocol enables the analysis of microbial toxicity and bioavailability of surface-released metal ions directly on solid surfaces within 30-60 min. Although optimized for copper and copper alloy surfaces and E. coli, the method can be extended to other types of metallic surfaces and bacterial strains.


Subject(s)
Anti-Bacterial Agents/pharmacology , Biosensing Techniques/methods , Copper/pharmacology , Escherichia coli/drug effects , Escherichia coli/physiology , Luminescent Measurements , Microbial Viability/drug effects , Surface Properties , Time Factors
7.
mBio ; 9(2)2018 04 17.
Article in English | MEDLINE | ID: mdl-29666286

ABSTRACT

The microbiological safety of fresh produce is monitored almost exclusively by culture-based detection methods. However, bacterial food-borne pathogens are known to enter a viable-but-nonculturable (VBNC) state in response to environmental stresses such as chlorine, which is commonly used for fresh produce decontamination. Here, complete VBNC induction of green fluorescent protein-tagged Listeria monocytogenes and Salmonella enterica serovar Thompson was achieved by exposure to 12 and 3 ppm chlorine, respectively. The pathogens were subjected to chlorine washing following incubation on spinach leaves. Culture data revealed that total viable L. monocytogenes and Salmonella Thompson populations became VBNC by 50 and 100 ppm chlorine, respectively, while enumeration by direct viable counting found that chlorine caused a <1-log reduction in viability. The pathogenicity of chlorine-induced VBNC L. monocytogenes and Salmonella Thompson was assessed by using Caenorhabditis elegans Ingestion of VBNC pathogens by C. elegans resulted in a significant life span reduction (P = 0.0064 and P < 0.0001), and no significant difference between the life span reductions caused by the VBNC and culturable L. monocytogenes treatments was observed. L. monocytogenes was visualized beyond the nematode intestinal lumen, indicating resuscitation and cell invasion. These data emphasize the risk that VBNC food-borne pathogens could pose to public health should they continue to go undetected.IMPORTANCE Many bacteria are known to enter a viable-but-nonculturable (VBNC) state in response to environmental stresses. VBNC cells cannot be detected by standard laboratory culture techniques, presenting a problem for the food industry, which uses these techniques to detect pathogen contaminants. This study found that chlorine, a sanitizer commonly used for fresh produce, induces a VBNC state in the food-borne pathogens Listeria monocytogenes and Salmonella enterica It was also found that chlorine is ineffective at killing total populations of the pathogens. A life span reduction was observed in Caenorhabditis elegans that ingested these VBNC pathogens, with VBNC L. monocytogenes as infectious as its culturable counterpart. These data show that VBNC food-borne pathogens can both be generated and avoid detection by industrial practices while potentially retaining the ability to cause disease.


Subject(s)
Anti-Infective Agents/metabolism , Chlorine/metabolism , Listeria monocytogenes/drug effects , Listeriosis/microbiology , Microbial Viability/drug effects , Salmonella Infections/microbiology , Salmonella enterica/drug effects , Animals , Caenorhabditis elegans , Disease Models, Animal , Listeria monocytogenes/growth & development , Listeria monocytogenes/pathogenicity , Salmonella enterica/growth & development , Salmonella enterica/pathogenicity , Spinacia oleracea/microbiology , Survival Analysis , Virulence
8.
Appl Environ Microbiol ; 82(7): 2132-2136, 2016 Jan 29.
Article in English | MEDLINE | ID: mdl-26826226

ABSTRACT

The pandemic of hospital-acquired infections caused by methicillin-resistant Staphylococcus aureus (MRSA) has declined, but the evolution of strains with enhanced virulence and toxins and the increase of community-associated infections are still a threat. In previous studies, 10(7) MRSA bacteria applied as simulated droplet contamination were killed on copper and brass surfaces within 90 min. However, contamination of surfaces is often via finger tips and dries rapidly, and it may be overlooked by cleaning regimes (unlike visible droplets). In this new study, a 5-log reduction of a hardy epidemic strain of MRSA (epidemic methicillin-resistant S. aureus 16 [EMRSA-16]) was observed following 10 min of contact with copper, and a 4-log reduction was observed on copper nickel and cartridge brass alloys in 15 min. A methicillin-sensitive S. aureus (MSSA) strain from an osteomyelitis patient was killed on copper surfaces in 15 min, and 4-log and 3-log reductions occurred within 20 min of contact with copper nickel and cartridge brass, respectively. Bacterial respiration was compromised on copper surfaces, and superoxide was generated as part of the killing mechanism. In addition, destruction of genomic DNA occurs on copper and brass surfaces, allaying concerns about horizontal gene transfer and copper resistance. Incorporation of copper alloy biocidal surfaces may help to reduce the spread of this dangerous pathogen.


Subject(s)
Alloys/pharmacology , Anti-Bacterial Agents/pharmacology , Copper/pharmacology , Genome, Bacterial/drug effects , Methicillin-Resistant Staphylococcus aureus/drug effects , Staphylococcus aureus/drug effects , Humans , Methicillin/pharmacology , Methicillin Resistance , Methicillin-Resistant Staphylococcus aureus/genetics , Methicillin-Resistant Staphylococcus aureus/growth & development , Nickel/pharmacology , Staphylococcal Infections/microbiology , Staphylococcus aureus/genetics , Staphylococcus aureus/growth & development , Zinc/pharmacology
9.
mBio ; 6(6): e01697-15, 2015 Nov 10.
Article in English | MEDLINE | ID: mdl-26556276

ABSTRACT

UNLABELLED: The evolution of new and reemerging historic virulent strains of respiratory viruses from animal reservoirs is a significant threat to human health. Inefficient human-to-human transmission of zoonotic strains may initially limit the spread of transmission, but an infection may be contracted by touching contaminated surfaces. Enveloped viruses are often susceptible to environmental stresses, but the human coronaviruses responsible for severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS) have recently caused increasing concern of contact transmission during outbreaks. We report here that pathogenic human coronavirus 229E remained infectious in a human lung cell culture model following at least 5 days of persistence on a range of common nonbiocidal surface materials, including polytetrafluoroethylene (Teflon; PTFE), polyvinyl chloride (PVC), ceramic tiles, glass, silicone rubber, and stainless steel. We have shown previously that noroviruses are destroyed on copper alloy surfaces. In this new study, human coronavirus 229E was rapidly inactivated on a range of copper alloys (within a few minutes for simulated fingertip contamination) and Cu/Zn brasses were very effective at lower copper concentration. Exposure to copper destroyed the viral genomes and irreversibly affected virus morphology, including disintegration of envelope and dispersal of surface spikes. Cu(I) and Cu(II) moieties were responsible for the inactivation, which was enhanced by reactive oxygen species generation on alloy surfaces, resulting in even faster inactivation than was seen with nonenveloped viruses on copper. Consequently, copper alloy surfaces could be employed in communal areas and at any mass gatherings to help reduce transmission of respiratory viruses from contaminated surfaces and protect the public health. IMPORTANCE: Respiratory viruses are responsible for more deaths globally than any other infectious agent. Animal coronaviruses that "host jump" to humans result in severe infections with high mortality, such as severe acute respiratory syndrome (SARS) and, more recently, Middle East respiratory syndrome (MERS). We show here that a closely related human coronavirus, 229E, which causes upper respiratory tract infection in healthy individuals and serious disease in patients with comorbidities, remained infectious on surface materials common to public and domestic areas for several days. The low infectious dose means that this is a significant infection risk to anyone touching a contaminated surface. However, rapid inactivation, irreversible destruction of viral RNA, and massive structural damage were observed in coronavirus exposed to copper and copper alloy surfaces. Incorporation of copper alloy surfaces in conjunction with effective cleaning regimens and good clinical practice could help to control transmission of respiratory coronaviruses, including MERS and SARS.


Subject(s)
Coronavirus 229E, Human/isolation & purification , Coronavirus 229E, Human/physiology , Environmental Microbiology , Microbial Viability , Alloys/pharmacology , Cell Line , Copper/pharmacology , Disinfectants/pharmacology , Humans , Time Factors , Virus Cultivation , Zinc/pharmacology
10.
PLoS One ; 10(10): e0141711, 2015.
Article in English | MEDLINE | ID: mdl-26516766

ABSTRACT

The long-term use of indwelling catheters results in a high risk from urinary tract infections (UTI) and blockage. Blockages often occur from crystalline deposits, formed as the pH rises due to the action of urease-producing bacteria; the most commonly found species being Proteus mirabilis. These crystalline biofilms have been found to develop on all catheter materials with P. mirabilis attaching to all surfaces and forming encrustations. Previous studies have mainly relied on electron microscopy to describe this process but there remains a lack of understanding into the stages of biofilm formation. Using an advanced light microscopy technique, episcopic differential interference contrast (EDIC) microscopy combined with epifluorescence (EF), we describe a non-destructive, non-contact, real-time imaging method used to track all stages of biofilm development from initial single cell attachment to complex crystalline biofilm formation. Using a simple six-well plate system, attachment of P. mirabilis (in artificial urine) to sections of silicone and hydrogel latex catheters was tracked over time (up to 24 days). Using EDIC and EF we show how initial attachment occurred in less than 1 h following exposure to P. mirabilis. This was rapidly followed by an accumulation of an additional material (indicated to be carbohydrate based using lectin staining) and the presence of highly elongated, motile cells. After 24 h exposure, a layer developed above this conditioning film and within 4 days the entire surface (of both catheter materials) was covered with diffuse crystalline deposits with defined crystals embedded. Using three-dimensional image reconstruction software, cells of P. mirabilis were seen covering the crystal surfaces. EDIC microscopy could resolve these four components of the complex crystalline biofilm and the close relationship between P. mirabilis and the crystals. This real-time imaging technique permits study of this complex biofilm development with no risk of artefacts due to sample manipulation. A full understanding of the stages and components involved in crystalline encrustation formation will aid in the development of new protocols to manage and ultimately prevent catheter blockage.


Subject(s)
Biofilms/growth & development , Proteus mirabilis/physiology , Time-Lapse Imaging/methods , Calcium Compounds/metabolism , Catheters, Indwelling/microbiology , Imaging, Three-Dimensional/methods , Software
11.
HERD ; 9(1): 64-79, 2015.
Article in English | MEDLINE | ID: mdl-26163568

ABSTRACT

OBJECTIVE: This is a translational science article that discusses copper alloys as antimicrobial environmental surfaces. Bacteria die when they come in contact with copper alloys in laboratory tests. Components made of copper alloys were also found to be efficacious in a clinical trial. BACKGROUND: There are indications that bacteria found on frequently touched environmental surfaces play a role in infection transmission. METHODS: In laboratory testing, copper alloy samples were inoculated with bacteria. In clinical trials, the amount of live bacteria on the surfaces of hospital components made of copper alloys, as well as those made from standard materials, was measured. Finally, infection rates were tracked in the hospital rooms with the copper components and compared to those found in the rooms containing the standard components. RESULTS: Greater than a 99.9% reduction in live bacteria was realized in laboratory tests. In the clinical trials, an 83% reduction in bacteria was seen on the copper alloy components, when compared to the surfaces made from standard materials in the control rooms. Finally, the infection rates were found to be reduced by 58% in patient rooms with components made of copper, when compared to patients' rooms with components made of standard materials. CONCLUSIONS: Bacteria die on copper alloy surfaces in both the laboratory and the hospital rooms. Infection rates were lowered in those hospital rooms containing copper components. Thus, based on the presented information, the placement of copper alloy components, in the built environment, may have the potential to reduce not only hospital-acquired infections but also patient treatment costs.


Subject(s)
Bacteria/isolation & purification , Copper/pharmacology , Cross Infection/prevention & control , Disinfection/methods , Environment Design , Infection Control/methods , Patients' Rooms/standards , Alloys/pharmacology , Anti-Infective Agents/pharmacology , Bacteria/drug effects , Cross Infection/microbiology , Cross Infection/transmission , Disinfection/standards , Humans , Intention to Treat Analysis , Microbial Sensitivity Tests/methods , Translational Research, Biomedical/methods
12.
Appl Environ Microbiol ; 81(3): 1085-91, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25452290

ABSTRACT

Norovirus is one of the most common causes of acute viral gastroenteritis. The virus is spread via the fecal-oral route, most commonly from infected food and water, but several outbreaks have originated from contamination of surfaces with infectious virus. In this study, a close surrogate of human norovirus causing gastrointestinal disease in mice, murine norovirus type 1 (MNV-1), retained infectivity for more than 2 weeks following contact with a range of surface materials, including Teflon (polytetrafluoroethylene [PTFE]), polyvinyl chloride (PVC), ceramic tiles, glass, silicone rubber, and stainless steel. Persistence was slightly prolonged on ceramic surfaces. A previous study in our laboratory observed that dry copper and copper alloy surfaces rapidly inactivated MNV-1 and destroyed the viral genome. In this new study, we have observed that a relatively small change in the percentage of copper, between 70 and 80% in copper nickels and 60 and 70% in brasses, had a significant influence on the ability of the alloy to inactivate norovirus. Nickel alone did not affect virus, but zinc did have some antiviral effect, which was synergistic with copper and resulted in an increased efficacy of brasses with lower percentages of copper. Electron microscopy of purified MNV-1 that had been exposed to copper and stainless steel surfaces suggested that a massive breakdown of the viral capsid had occurred on copper. In addition, MNV-1 that had been exposed to copper and treated with RNase demonstrated a reduction in viral gene copy number. This suggests that capsid integrity is compromised upon contact with copper, allowing copper ion access to the viral genome.


Subject(s)
Capsid/drug effects , Copper/toxicity , Disinfectants/toxicity , Microbial Viability/drug effects , Norovirus/drug effects , Virus Inactivation , Alloys/toxicity , Animals , Capsid/ultrastructure , Cell Line , Mice , Microscopy, Electron , Norovirus/physiology , Norovirus/ultrastructure , Viral Plaque Assay
13.
PLoS One ; 8(9): e75017, 2013.
Article in English | MEDLINE | ID: mdl-24040380

ABSTRACT

Noroviruses (family Caliciviridae) are the primary cause of viral gastroenteritis worldwide. The virus is highly infectious and touching contaminated surfaces can contribute to infection spread. Although the virus was identified over 40 years ago the lack of methods to assess infectivity has hampered the study of the human pathogen. Recently the murine virus, MNV-1, has successfully been used as a close surrogate. Copper alloys have previously been shown to be effective antimicrobial surfaces against a range of bacteria and fungi. We now report rapid inactivation of murine norovirus on alloys, containing over 60% copper, at room temperature but no reduction of infectivity on stainless steel dry surfaces in simulated wet fomite and dry touch contamination. The rate of inactivation was initially very rapid and proportional to copper content of alloy tested. Viral inactivation was not as rapid on brass as previously observed for bacteria but copper-nickel alloy was very effective. The use of chelators and quenchers of reactive oxygen species (ROS) determined that Cu(II) and especially Cu(I) ions are still the primary effectors of toxicity but quenching superoxide and hydroxyl radicals did not confer protection. This suggests Fenton generation of ROS is not important for the inactivation mechanism. One of the targets of copper toxicity was the viral genome and a reduced copy number of the gene for a viral encoded protein, VPg (viral-protein-genome-linked), which is essential for infectivity, was observed following contact with copper and brass dry surfaces. The use of antimicrobial surfaces containing copper in high risk closed environments such as cruise ships and care facilities could help to reduce the spread of this highly infectious and costly pathogen.


Subject(s)
Alloys/chemistry , Antiviral Agents/chemistry , Copper/chemistry , Nickel/chemistry , Norovirus/physiology , Virus Inactivation , Animals , Cell Line , Chelating Agents/chemistry , Decontamination , Disinfectants , Fomites/virology , Food Contamination/prevention & control , Food Microbiology , Linear Models , Macrophages/cytology , Mice , Monocytes/cytology , Reactive Oxygen Species , Stainless Steel , Surface Properties , Temperature , Zinc/chemistry
14.
Biofouling ; 29(9): 1029-42, 2013.
Article in English | MEDLINE | ID: mdl-23964799

ABSTRACT

Biofouling is a major problem for long-term deployment of sensors in the marine environment. This study showed that significant biofilm formation occurred on a variety of artificial materials (glass, copper, Delrin(™) and poly-methyl methacrylate [PMMA]) deployed for 10 days at a depth of 4700 m in the Cayman Trough. Biofilm surface coverage was used as an indicator of biomass. The lowest biofilm coverage was on copper and PMMA. Molecular analyses indicated that bacteria dominated the biofilms found on copper, Delrin(™) and PMMA with 75, 55 and 73% coverage, respectively. Archea (66%) were dominant on the glass surface simulating interior sensor conditions, whereas Eukarya comprised the highest percentage of microflora (75%) on the glass simulating the exterior of sensors. Analysis of Denaturing Gradient Gel Electrophoresis profiles indicated that copper and Delrin(™) shared the same community diversity, which was not the case for glass and PMMA, or between PMMA and copper/Delrin(™). Sequence alignment matches belonged exclusively to uncultivable microorganisms, most of which were not further classified. One extracted sequence found on glass was associated with Cowellia sp., while another extracted from the PMMA surface was associated with a bacterium in the Alterominidaceae, both γ-proteobacteria. The results demonstrate the necessity of understanding biofilm formation in the deep sea and the potential need for mitigation strategies for any kind of long-term deployment of remote sensors in the marine environment.


Subject(s)
Archaea/physiology , Bacteria/genetics , Bacterial Physiological Phenomena , Biofilms/growth & development , Eukaryota/physiology , Hydrothermal Vents/microbiology , Caribbean Region , DNA, Archaeal/genetics , DNA, Archaeal/metabolism , DNA, Bacterial/genetics , DNA, Bacterial/metabolism , Denaturing Gradient Gel Electrophoresis , Eukaryota/genetics , Microscopy, Confocal , Microscopy, Electron, Scanning , Microscopy, Fluorescence , Microscopy, Interference , RNA, Ribosomal, 16S/genetics , RNA, Ribosomal, 16S/metabolism , RNA, Ribosomal, 18S/genetics , RNA, Ribosomal, 18S/metabolism , Time Factors
15.
mBio ; 3(6)2012 Nov 27.
Article in English | MEDLINE | ID: mdl-23188508

ABSTRACT

UNLABELLED: Horizontal gene transfer (HGT) is largely responsible for increasing the incidence of antibiotic-resistant infections worldwide. While studies have focused on HGT in vivo, this work investigates whether the ability of pathogens to persist in the environment, particularly on touch surfaces, may also play an important role. Escherichia coli, virulent clone ST131, and Klebsiella pneumoniae harboring extended-spectrum-ß-lactamase (ESBL) bla(CTX-M-15) and metallo-ß-lactamase bla(NDM-1), respectively, exhibited prolonged survival on stainless steel, with approximately 10(4) viable cells remaining from an inoculum of 10(7) CFU per cm(2) after 1 month at 21°C. HGT of bla to an antibiotic-sensitive but azide-resistant recipient E. coli strain occurred on stainless steel dry touch surfaces and in suspension but not on dry copper. The conjugation frequency was approximately 10 to 50 times greater and occurred immediately, and resulting transconjugants were more stable with ESBL E. coli as the donor cell than with K. pneumoniae, but bla(NDM-1) transfer increased with time. Transconjugants also exhibited the same resistance profile as the donor, suggesting multiple gene transfer. Rapid death, inhibition of respiration, and destruction of genomic and plasmid DNA of both pathogens occurred on copper alloys accompanied by a reduction in bla copy number. Naked E. coli DNA degraded on copper at 21°C and 37°C but slowly at 4°C, suggesting a direct role for the metal. Persistence of viable pathogenic bacteria on touch surfaces may not only increase the risk of infection transmission but may also contribute to the spread of antibiotic resistance by HGT. The use of copper alloys as antimicrobial touch surfaces may help reduce infection and HGT. IMPORTANCE: Horizontal gene transfer (HGT) conferring resistance to many classes of antimicrobials has resulted in a worldwide epidemic of nosocomial and community infections caused by multidrug-resistant microorganisms, leading to suggestions that we are in effect returning to the preantibiotic era. While studies have focused on HGT in vivo, this work investigates whether the ability of pathogens to persist in the environment, particularly on touch surfaces, may also play an important role. Here we show prolonged (several-week) survival of multidrug-resistant Escherichia coli and Klebsiella pneumoniae on stainless steel surfaces. Plasmid-mediated HGT of ß-lactamase genes to an azide-resistant recipient E. coli strain occurred when the donor and recipient cells were mixed together on stainless steel and in suspension but not on copper surfaces. In addition, rapid death of both antibiotic-resistant strains and destruction of plasmid and genomic DNA were observed on copper and copper alloy surfaces, which could be useful in the prevention of infection spread and gene transfer.


Subject(s)
Bacterial Adhesion/genetics , Drug Resistance, Bacterial/genetics , Escherichia coli/genetics , Gene Transfer, Horizontal , Klebsiella pneumoniae/genetics , beta-Lactamases/genetics , Copper , Escherichia coli/drug effects , Escherichia coli/metabolism , Gene Dosage , Klebsiella pneumoniae/drug effects , Klebsiella pneumoniae/metabolism , Plasmids/genetics , Plasmids/metabolism , Stainless Steel , Surface Properties , Temperature , beta-Lactamases/metabolism
16.
Bioorg Med Chem Lett ; 18(2): 518-22, 2008 Jan 15.
Article in English | MEDLINE | ID: mdl-18068365

ABSTRACT

Eleven flavonoid derivatives were synthesised using a modified Baker-Venkataraman rearrangement, and subsequent microwave-assisted closure of the heterocyclic ring. All of the synthetic compounds displayed antifungal activity against Aspergillus niger and Fusarium oxysporium, and two of the synthetic flavonoid analogues exhibited significant activity against methicillin-resistant Staphylococcus aureus.


Subject(s)
Anti-Infective Agents/chemical synthesis , Anti-Infective Agents/pharmacology , Flavonoids/chemical synthesis , Flavonoids/pharmacology , Microwaves , Aspergillus niger/drug effects , Fusarium/drug effects , Methicillin Resistance , Microbial Sensitivity Tests , Staphylococcus aureus/drug effects
17.
J Exp Bot ; 58(6): 1433-49, 2007.
Article in English | MEDLINE | ID: mdl-17347132

ABSTRACT

Developmental and biophysical leaf characteristics that influence post-harvest shelf life in lettuce, an important leafy crop, have been examined. The traits were studied using 60 informative F9 recombinant inbed lines (RILs) derived from a cross between cultivated lettuce (Lactuca sativa cv. Salinas) and wild lettuce (L. serriola acc. UC96US23). Quantitative trait loci (QTLs) for shelf life co-located most closely with those for leaf biophysical properties such as plasticity, elasticity, and breakstrength, suggesting that these are appropriate targets for molecular breeding for improved shelf life. Significant correlations were found between shelf life and leaf size, leaf weight, leaf chlorophyll content, leaf stomatal index, and epidermal cell number per leaf, indicating that these pre-harvest leaf development traits confer post-harvest properties. By studying the population in two contrasting environments in northern and southern Europe, the genotype by environment interaction effects of the QTLs relevant to leaf development and shelf life were assessed. In total, 107 QTLs, distributed on all nine linkage groups, were detected from the 29 traits. Only five QTLs were common in both environments. Several areas where many QTLs co-located (hotspots) on the genome were identified, with relatively little overlap between developmental hotspots and those relating to shelf life. However, QTLs for leaf biophysical properties (breakstrength, plasticity, and elasticity) and cell area correlated well with shelf life, confirming that the ideal ideotype lettuce should have small cells with strong cell walls. The identification of QTLs for leaf development, strength, and longevity will lead to a better understanding of processability at a genetic and cellular level, and allow the improvement of salad leaf quality through marker-assisted breeding.


Subject(s)
Lactuca/genetics , Plant Leaves/genetics , Quantitative Trait Loci , Chlorophyll/metabolism , Crosses, Genetic , England , Plant Leaves/anatomy & histology , Plant Leaves/growth & development , Portugal
18.
Appl Environ Microbiol ; 73(9): 2854-9, 2007 May.
Article in English | MEDLINE | ID: mdl-17337541

ABSTRACT

Most of the bacteria in drinking water distribution systems are associated with biofilms. In biofilms, their nutrient supply is better than in water, and biofilms can provide shelter against disinfection. We used a Propella biofilm reactor for studying the survival of Mycobacterium avium, Legionella pneumophila, Escherichia coli, and canine calicivirus (CaCV) (as a surrogate for human norovirus) in drinking water biofilms grown under high-shear turbulent-flow conditions. The numbers of M. avium and L. pneumophila were analyzed with both culture methods and with peptide nucleic acid fluorescence in situ hybridization (FISH) methods. Even though the numbers of pathogens in biofilms decreased during the experiments, M. avium and L. pneumophila survived in biofilms for more than 2 to 4 weeks in culturable forms. CaCV was detectable with a reverse transcription-PCR method in biofilms for more than 3 weeks. E. coli was detectable by culture for only 4 days in biofilms and 8 days in water, suggesting that it is a poor indicator of the presence of certain waterborne pathogens. With L. pneumophila and M. avium, culture methods underestimated the numbers of bacteria present compared to the FISH results. This study clearly proved that pathogenic bacteria entering water distribution systems can survive in biofilms for at least several weeks, even under conditions of high-shear turbulent flow, and may be a risk to water consumers. Also, considering the low number of virus particles needed to result in an infection, their extended survival in biofilms must be taken into account as a risk for the consumer.


Subject(s)
Biofilms/growth & development , Caliciviridae/growth & development , Escherichia coli/growth & development , Legionella pneumophila/growth & development , Mycobacterium avium/growth & development , Water Microbiology , Water Movements , Water Supply , DNA Primers , In Situ Hybridization, Fluorescence
19.
Int J Food Microbiol ; 111(2): 93-8, 2006 Sep 01.
Article in English | MEDLINE | ID: mdl-16876278

ABSTRACT

Listeria monocytogenes is an important re-emerging pathogen which is commonly found in the environment. Many outbreaks have been associated with the contamination of food produce, often linked to cross-contamination from surfaces or equipment to prepared foodstuffs. In the present study a number of copper-base metal alloys have been used to assess the survival times of L. monocytogenes on different materials, in comparison with stainless steel. High concentrations (10(7)) of bacteria were placed on metal coupons cut from each alloy. After defined incubation times, coupons were placed in tubes containing phosphate buffered saline and vortexed to remove the cells. Aliquots were then plated onto tryptone blood agar plates and the number of colony forming units counted. The high concentration of bacteria was used to represent a "worst-case" scenario. The results indicate that survival is greatly reduced on a copper-base alloy compared to stainless steel. Viable cells could be detected on stainless steel after 24 h incubation at room temperature. On copper, brass, aluminium bronze and silicon bronze, no viable bacteria could be detected after 60 min incubation, indicating a 5 log reduction (the detection limit of the procedure was 100 bacteria). No cells could be detected from copper nickel and copper nickel zinc alloys, after 90 min incubation. The viability stain, 5-cyano-2,3-ditolyl tetrazolium chloride (CTC), confirmed these results, with actively respiring bacteria being clearly labelled on stainless steel after 24 h. The results suggest that careful choice of surface material could reduce the potential risk of cross-contamination in industrial, commercial and domestic environments.


Subject(s)
Alloys , Equipment Contamination/prevention & control , Food Contamination/prevention & control , Listeria monocytogenes/growth & development , Metals , Colony Count, Microbial , Copper , Environmental Microbiology , Food Microbiology , Humans , Stainless Steel , Time Factors
20.
Appl Environ Microbiol ; 72(8): 5453-62, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16885298

ABSTRACT

Using fluorescence in situ hybridization to detect bacterial groups has several inherent limitations. DNA probes are generally used, targeting sites on the 16S rRNA. However, much of the 16S rRNA is highly conserved, with variable regions often located in inaccessible areas where secondary structures can restrict probe access. Here, we describe the use of peptide nucleic acid (PNA) probes as a superior alternative to DNA probes, especially when used for environmental samples. A complex bacterial genus (Legionella) was studied, and two probes were designed, one to detect all species and one targeted to Legionella pneumophila. These probes were developed from existing sequences and are targeted to low-binding-affinity sites on the 16S rRNA. In total, 47 strains of Legionella were tested. In all cases, the Legionella spp. PNA probe labeled cells strongly but did not bind to any non-Legionella species. Likewise, the specific L. pneumophila PNA probe labeled only strains of L. pneumophila. By contrast, the equivalent DNA probes performed poorly. To assess the applicability of this method for use on environmental samples, drinking-water biofilms were spiked with a known concentration of L. pneumophila bacteria. Quantifications of the L. pneumophila bacteria were compared using PNA hybridization and standard culture methods. The culture method quantified only 10% of the number of L. pneumophila bacteria found by PNA hybridization. This illustrates the value of this method for use on complex environmental samples, especially where cells may be in a viable but noncultivable state.


Subject(s)
Biofilms/growth & development , Legionella/classification , Legionella/isolation & purification , Peptide Nucleic Acids/metabolism , RNA, Ribosomal, 16S/metabolism , Binding Sites , DNA Probes , Environmental Monitoring , Legionella/genetics , Legionella/growth & development , Nucleic Acid Hybridization/methods , Species Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...