Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Invest Ophthalmol Vis Sci ; 54(5): 3729-37, 2013 May 01.
Article in English | MEDLINE | ID: mdl-23611994

ABSTRACT

PURPOSE: Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. METHODS: Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 µL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. RESULTS: Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. CONCLUSIONS: The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.


Subject(s)
Capillary Action , Cytokines/metabolism , Dry Eye Syndromes/metabolism , Sodium Chloride/administration & dosage , Tears/metabolism , Adult , Aged , Biomarkers/metabolism , Eye Proteins/metabolism , Feasibility Studies , Female , Humans , Male , Middle Aged , Specimen Handling/methods , Young Adult
2.
Curr Eye Res ; 33(7): 525-44, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18600485

ABSTRACT

PURPOSE: To compare instruments and reagents used for cytometric bead-based assay (CBA) of cytokines in human tears. METHODS: Two CBA instruments and reagent kits from five vendors were compared in parallel. Vendor protocols were modified to accommodate tear volumes. Precision, recovery, dilution linearity, and stability were evaluated. RESULTS: Luminextrade mark and Bio-Radtrade mark proved optimal for tear CBA. Good correlation for dilution linearity was observed (r > 0.80, p < 0.05) for 1-4-mu l sample volumes. Samples were stable for 30 min at 25 degrees C. CONCLUSION: Many tear cytokines can be reliably measured by CBA using an optimized protocol. Concentrations remain stable during periods consistent with collection.


Subject(s)
Cytokines/analysis , Eye Proteins/analysis , Flow Cytometry/methods , Tears/chemistry , Adult , Humans , Middle Aged , Reagent Kits, Diagnostic , Reproducibility of Results , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL
...