Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
AJNR Am J Neuroradiol ; 19(8): 1489-93, 1998 Sep.
Article in English | MEDLINE | ID: mdl-9763383

ABSTRACT

BACKGROUND AND PURPOSE: Although MR spectroscopy and functional MR imaging of the brain have been successful at 4 T, conventional fast spin-echo imaging of the brain at 4 T has not been adequately evaluated. The purpose of this study was to compare the detection of white matter abnormalities in multiple sclerosis (MS) at 1.5 T and 4 T. METHODS: Fifteen patients with clinically definite MS were imaged at both 1.5 T and 4 T within a 1-week period. Comparison was made between fast spin-echo long-TR images at both field strengths. Pulse sequences were tailored to maximize resolution and signal-to-noise ratio in clinically relevant imaging times (< 7 min). Four interpreters independently reviewed the images obtained at both field strengths in separate sessions and evaluated them for lesion identification, size, characterization, and subjective resolution. Differences in interpretations at 1.5 T and 4 T were subsequently recorded. RESULTS: Images obtained at 4 T showed a mean of 88 more lesions as compared with images obtained at 1.5 T. All the lesions measured less than 5 mm and were typically aligned along perivascular spaces. Twenty-five consensually identified lesions on 4-T images were not seen at all on 1.5-T images. Moreover, 4-T images showed 56 additional consensually identified lesions, which were indistinct and seen only in retrospect on 1.5-T images. These lesions were frequently (n = 48) identified in large confluent areas of white matter signal intensity abnormality at 1.5 T. All observers also agreed that 4-T images subjectively enhanced the perception of normal perivascular spaces and small perivascular lesions. CONCLUSION: MR imaging at 4 T can depict white matter abnormalities in MS patients not detectable at 1.5 T through higher resolution with comparable signal-to-noise ratio and imaging times.


Subject(s)
Brain/pathology , Echo-Planar Imaging , Image Enhancement , Magnetic Resonance Imaging , Multiple Sclerosis/diagnosis , Nerve Fibers, Myelinated/pathology , Adult , Female , Humans , Male , Middle Aged , Reference Values , Sensitivity and Specificity
2.
J Comput Assist Tomogr ; 22(5): 771-6, 1998.
Article in English | MEDLINE | ID: mdl-9754115

ABSTRACT

PURPOSE: The purpose of this study was to compare contrast-enhanced GRE and conventional SE (CSE) fat-suppressed T1-weighted techniques in the evaluation of head and neck lesions. A hybrid, opposed phase, frequency-selective, fat-suppressed fast multiplanar spoiled GRE (FMPSPGR) sequence was compared with a fat-suppressed CSE sequence. METHOD: Thirty-two patients with head and neck pathology were evaluated with both fat-suppressed CSE and FMPSPGR sequences. Regions of interest obtained by two viewers in consensus were used to establish contrast-to-noise (CNR) and signal-to-noise ratios for both sequences. Three neuroradiologists also independently reviewed the images for quality of fat suppression, lesion conspicuity, and potential pitfalls. RESULTS: The CNR of the FMPSPGR sequence was superior to that of the fat-suppressed CSE sequence. Subjectively, all three reviewers rated the FMPSPGR sequence as having fat suppression equal to or better than that in the CSE sequence in 94% of cases. Imaging times for the FMPSPGR sequence were 60-75% faster than those for the CSE sequence. CONCLUSION: Enhanced imaging of the head and neck region using an opposed phase, fat-suppressed GRE sequence results in improved fat suppression compared with the CSE technique, with substantial savings in imaging time.


Subject(s)
Contrast Media , Gadolinium DTPA , Head/pathology , Magnetic Resonance Imaging/methods , Neck/pathology , Adult , Aged , Aged, 80 and over , Female , Head and Neck Neoplasms/diagnosis , Humans , Male , Middle Aged , Observer Variation , Prospective Studies , Time Factors
3.
Neuroradiology ; 40(6): 359-63, 1998 Jun.
Article in English | MEDLINE | ID: mdl-9689622

ABSTRACT

We carried out a retrospective analysis of imaging and clinical findings in 52 children with a history of cervical spinal trauma. No patient had evidence of a fracture on plain films or CT. All had MRI at 1.5 T because of persistent or delayed symptoms, unexplained findings of injury or instability, or as further assessment of the extent of soft-tissue injury. Clinical follow-up ranged from 6 months to 3.5 years. MRI was evaluated for its influence on therapy and outcome. MRI was positive in 16 (31%) of 52 patients. Posterior soft-tissue or ligamentous injury was the most common finding in the 10 patients with mild to moderate trauma, while acute disc bulges and longitudinal ligament disruption, each seen in one case, were uncommon. MRI was superior to CT for assessment of the extent of soft-tissue injury and for identification of spinal cord injuries and intracanalicular hemorrhage in the six patients with more severe trauma. MRI specifically influenced the management of all four patients requiring surgery by extending the level of posterior stabilization. No patients with normal MRI or any of the 10 with radiographically stable soft-tissue injury on MRI, developed delayed clinical or radiographic evidence of instability or deformity.


Subject(s)
Cervical Vertebrae/injuries , Magnetic Resonance Imaging , Neck Injuries/diagnosis , Soft Tissue Injuries/diagnosis , Spinal Injuries/diagnosis , Tomography, X-Ray Computed , Adolescent , Adult , Cervical Vertebrae/pathology , Cervical Vertebrae/surgery , Child , Child, Preschool , Diagnosis, Differential , Female , Follow-Up Studies , Humans , Infant , Intervertebral Disc Displacement/diagnosis , Intervertebral Disc Displacement/surgery , Ligaments, Articular/injuries , Ligaments, Articular/pathology , Ligaments, Articular/surgery , Male , Neck Injuries/surgery , Retrospective Studies , Sensitivity and Specificity , Soft Tissue Injuries/surgery , Spinal Injuries/surgery
4.
AJNR Am J Neuroradiol ; 18(6): 1035-9, 1997.
Article in English | MEDLINE | ID: mdl-9194430

ABSTRACT

PURPOSE: To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS: Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighted and fast spin-echo proton density- and T2-weighted images were followed by fast FLAIR images. FLAIR parameters were varied to optimize lesion conspicuity with optimal inversion times (TIs) ranging from 2400 to 2600. Lesion conspicuity and detection were compared between the fast spin-echo and FLAIR images by three radiologists who reached agreement by consensus. RESULTS: The FLAIR technique effectively suppressed cerebrospinal fluid (CSF) signal and reduced CSF pulsation and truncation artifacts in all cases. Shorter imaging parameters (repetition time of 4000 to 6000, TI of 1500 to 2000) uniformly decreased lesion conspicuity in all subjects. Of 11 cord lesions in five subjects imaged with the longer parameters (repetition time of 8000 to 11,000, TI of 2400 to 2600), three were not seen on FLAIR images, four were less conspicuous on FLAIR images, and four were seen equally or better on FLAIR images. CONCLUSION: Although successful in suppressing CSF signal and reducing imaging artifacts, fast FLAIR imaging appears unreliable in the detection of MS lesions in the spinal cord.


Subject(s)
Image Enhancement , Magnetic Resonance Imaging , Multiple Sclerosis/diagnosis , Spinal Cord/pathology , Adult , Artifacts , Brain/pathology , Cerebrospinal Fluid , Female , Humans , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity
5.
J Comput Assist Tomogr ; 19(4): 527-31, 1995.
Article in English | MEDLINE | ID: mdl-7622677

ABSTRACT

OBJECTIVE: Cerebral vein thrombosis (CVT) is a potentially life-threatening entity with a protean clinical presentation that can lead to delays in diagnosis and treatment. Computed tomography of the brain is often the initial imaging tool in evaluation of these patients, but is frequently nondiagnostic. This study identifies subcortical hemorrhage (SCH) as an indicator of radiographically occult CVT on CT. MATERIALS AND METHODS: A retrospective analysis of all subjects (n = 24) with CVT proven by MRI over a 4 year period was performed. The CT examinations of all subjects were evaluated for the presence of SCH and signs of CVT. An evaluation of the correlation between findings on CT and MRI as well as the delay in diagnosis and treatment secondary to unrecognized CVT on CT was also performed. RESULTS: Subcortical hemorrhage was noted in 9 of 24 (38%) subjects with CVT by MRI. The CT antedated MRI in eight of these subjects as the initial evaluation for presenting neurological symptoms. Subcortical hemorrhage was noted in six of eight of these subjects as the sole CT finding. Subcortical hemorrhage as well as CVT was seen in one subject, and no abnormality was seen in the final subject. Cerebral vein thrombosis was not suggested as a diagnosis in any of the six subjects with SCH as the sole radiographic finding. In all six of these cases, a delay in diagnosis occurred pending MRI obtained subsequently secondary to clinical deterioration. CONCLUSION: Subcortical hemorrhage can be seen in association with acute CVT and can be the sole abnormality on head CT. SCH as an isolated finding on CT suggests the possibility of unrecognized CVT, warranting further investigation by MRI.


Subject(s)
Cerebral Hemorrhage/diagnostic imaging , Intracranial Embolism and Thrombosis/diagnostic imaging , Adult , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/pathology , Cerebral Hemorrhage/diagnosis , Cerebral Hemorrhage/etiology , Cerebral Veins/diagnostic imaging , Cerebral Veins/pathology , Female , Humans , Intracranial Embolism and Thrombosis/complications , Intracranial Embolism and Thrombosis/diagnosis , Magnetic Resonance Imaging , Male , Retrospective Studies , Tomography, X-Ray Computed
6.
Chest ; 107(1): 74-80, 1995 Jan.
Article in English | MEDLINE | ID: mdl-7813316

ABSTRACT

BACKGROUND: Pulmonary infection and tumor in the AIDS population has a variable clinical and radiographic presentation. The association between the radiographic presentation of pulmonary tuberculosis and CD4 T lymphocyte count in the HIV-infected patient is investigated in order to provide an empirical approach for early diagnosis, treatment, and isolation of infected subjects. METHODS: A retrospective analysis of chest radiographs, CD4 T lymphocyte counts, and clinical history of 35 subjects from 3 urban hospitals was performed. All subjects were HIV-seropositive and had culture-proven pulmonary tuberculosis. Radiographs were evaluated for the presence of either a pattern characteristic of post-primary tuberculosis (typical pattern) or a pattern uncharacteristic of post-primary infection (atypical pattern). RESULTS: Twenty-one of 26 subjects with a CD4 T lymphocyte count less than 0.20 x 10(9) cells/L, whereas only 1 of 9 subjects with a CD4 T lymphocyte count of 0.20 x 10(9) cells/L or more presented with an atypical pattern of pulmonary tuberculosis (p < 0.001). The mean CD4 T lymphocyte counts of those subjects presenting with atypical versus typical radiographic pattern of post-primary pulmonary tuberculosis were 0.069 x 10(9) cells/L (n = 22) and 0.323 x 10(9) cells/L (n = 13), respectively (p < 0.01). Twenty-one of the 22 subjects with an atypical radiographic pattern of pulmonary tuberculosis were significantly immunosuppressed (CD4 < 0.20 x 10(9) cells/L). Atypical radiographic pattern included diffuse and lower lobar opacities, pleural effusion, mediastinal adenopathy, interstitial nodules, and a normal chest radiograph. CONCLUSION: AIDS patients presenting with CD4 count less than 0.20 x 10(9) cells/L and an atypical radiographic pattern for pulmonary tuberculosis are at risk for tuberculous infection requiring appropriate treatment and isolation until the diagnosis of pulmonary tuberculosis has been excluded.


Subject(s)
AIDS-Related Opportunistic Infections/diagnostic imaging , AIDS-Related Opportunistic Infections/immunology , CD4 Lymphocyte Count , Lung/diagnostic imaging , Tuberculosis, Pulmonary/diagnostic imaging , Tuberculosis, Pulmonary/immunology , Acquired Immunodeficiency Syndrome/immunology , Adult , Female , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Tuberculosis, Pulmonary/complications
7.
J Pediatr Orthop ; 9(6): 672-4, 1989.
Article in English | MEDLINE | ID: mdl-2600174

ABSTRACT

We analyzed the influence of posterior spinal fusion with Harrington rod instrumentation on spinal balance in 85 patients with primary thoracic curve patterns. Utilizing roentgenographic techniques of measurement, spinal decompensation was improved measurably in 64% of the patients, and lateral trunk shift improved in 82% of the patients with preoperative alterations of spinal balance.


Subject(s)
Scoliosis/surgery , Spinal Fusion , Adolescent , Adult , Anthropometry , Child , Female , Follow-Up Studies , Humans , Male , Radiography , Scoliosis/diagnostic imaging , Scoliosis/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...