Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 13(6)2023 Mar 11.
Article in English | MEDLINE | ID: mdl-36980373

ABSTRACT

(1) Objective: To evaluate the diagnostic performance of prototype handheld ultrasound compared to automated breast ultrasound, according to the fifth edition of BI-RADS categorization, among females with positive lumps. (2) Methods: A total of 1004 lesions in 162 participants who underwent both prototype handheld ultrasound and automated breast ultrasound were included. Two radiologists and a sonographer independently evaluated the sonographic features of each lesion according to the fifth BI-RADS edition. The kappa coefficient (κ) was calculated for each BI-RADS descriptor and final assessment category. The cross-tabulation was performed to see whether there were differences between the ABUS and prototype HHUS results. Specificity and sensitivity were evaluated and compared using the McNamar test. (3) Results: ABUS and prototype HHUS observers found the same number of breast lesions in the 324 breasts of the 162 respondents. There was no significant difference in the mean lesion size, with a maximum mean length dimension of 0.48 ± 0.33 cm. The assessment of the lesion's shape, orientation, margin, echo pattern, posterior acoustic features, and calcification was obtained with good to excellent agreements between ABUS and prototype HHUS observers (κ = 0.70-1.0). There was absolutely no significant difference between ABUS and prototype HHUS in assessment of lesion except for lesion orientation p = 0.00. Diagnostic accuracy (99.8% and 97.7-98.9%), sensitivity (99.5% and 98.0-99.0%), specificity (99.8% and 99.6-99.8%), positive predictive value (98.1% and 90.3-96.2%), negative predictive value (90.0% and 84.4-88.7%), and areas under the curve (0.98 and 0.83-0.92; p < 0.05) were not significantly different between ABUS and prototype HHUS observers. (4) Conclusion: According to the fifth BI-RADS edition, automated breast ultrasound is not statistically significantly different from prototype handheld ultrasound with regard to interobserver variability and diagnostic performance.

2.
Diagnostics (Basel) ; 12(2)2022 Feb 19.
Article in English | MEDLINE | ID: mdl-35204629

ABSTRACT

OBJECTIVE: To compare the diagnostic performance of the automatic breast volume scanner (ABVS) against the handheld ultrasound (HHUS) in the differential diagnosis of benign and malignant breast lesions. METHODS: A systematic search and review of studies involving ABVS and HHUS for breast cancer screening were performed. The search involved the data taken from Scopus, PubMed, and science direct databases and was conducted between the year 2011 to 2020. The prospective method was used in determining the inclusion and exclusion criteria while the evidence level was determined using the BI-RADS categories for diagnostic studies. In addition, the parameters of specificity, mean age, sensitivity, tumor number, and diagnostic accuracy of the ABVS and HHUS were summarized. RESULTS: No systematic review or randomized controlled trial were identified in the systematic search while one cross-sectional study, eight retrospective studies, and 10 prospective studies were found. Sufficient follow-up of the subjects with benign and malignant findings were made only in 10 studies, in which only two had used ABVS and HHUS after performing mammographic screening and MRI. Analysis was made of 21 studies, which included 5448 lesions (4074 benign and 1374 malignant) taken from 6009 patients. The range of sensitivity was (0.72-1.0) for ABVS and (0.62-1.0) for HHUS; the specificity range was (0.52-0.98)% for ABVS and (0.49-0.99)% for HHUS. The accuracy range among the 11 studies was (80-99)% and (59-98)% for the HHUS and ABVS, respectively. The identified tumors had a mean size of 2.1 cm, and the detected cancers had a mean percentage of 94% (81-100)% in comparison to the non-cancer in all studies. CONCLUSIONS: The evidence available in the literature points to the fact that the diagnostic performance of both ABVS and HHUS are similar with reference to the differentiation of malignant and benign breast lesions.

3.
PLoS One ; 10(5): e0125511, 2015.
Article in English | MEDLINE | ID: mdl-25993127

ABSTRACT

MWCNTs/TiO2 nanocomposite was prepared by oxidising MWCNT in H2SO4/HNO3 then decorating it with TiO2-p25 nanopowder. The composites were characterised using XRD, TEM, FT-IR PL and UV-vis spectroscopy. The TEM images have shown TiO2 nanoparticles immobilised onto the sidewalls of the MWCNTs. The UV-vis spectrum confirms that the nanocomposites can significantly absorb more light in the visible regions compared with the commercial TiO2 (P25). The catalytic activity of these nanocomposites was determined by photooxidation of MB aqueous solution in the presence of visible light. The MWCNTs/TiO2 (1:3) mass ratio showed maximum degradation efficiency. However, its activity was more favourable in alkaline and a neutral pH than an acidic medium.


Subject(s)
Methylene Blue/radiation effects , Nanocomposites/chemistry , Nanotubes, Carbon/chemistry , Titanium/chemistry , Titanium/radiation effects , Hydrogen-Ion Concentration , Methylene Blue/chemistry , Microscopy, Electron, Transmission , Nanocomposites/ultrastructure , Nanotubes, Carbon/ultrastructure , Photochemical Processes , Photolysis , Spectrophotometry , Spectroscopy, Fourier Transform Infrared , X-Ray Diffraction
SELECTION OF CITATIONS