Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Injury ; 55(2): 111185, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38070327

ABSTRACT

INTRODUCTION: Hip fractures have become a major public health priority due to their increasing incidence. Intramedullary (IM) nailing has gained popularity as a surgical technique for managing these fractures. However, comparative studies with extramedullary devices indicate potentially increased mechanical complications associated with IM nailing. Specifically, there have been recent reports of early implant fracture associated with the TFNA system. This study compares the rate of mechanical complications between 3 implants. Secondarily, we analysed the factors associated with implant fracture and all other mechanical complications. METHODS: This retrospective study included 803 IM nails performed between 2008-2021 for the fixation of proximal femur fractures at a level 1 trauma centre. We recorded patient demographics, AO fracture classification, implant specification and intra-operative parameters such as tip-apex distance, Cleveland index, reduction quality, presence of medial calcar integrity, neck-shaft angle. The outcomes analysed included implant fracture, lag screw cut-out, >10 mm backing out, autodynamisation, periprosthetic fracture, non-union at 6 months and time to revision surgery. RESULTS: The overall implant fracture rate was 3.1 % (25/803), with no statistically significant difference between the three devices (p = 0.51). The TFNA group included 183 patients with a median follow-up of 1.6 years. The TFNA fracture rate was 2.2 % (4/183) which occurred at 207 +/- 16.66 days post-operatively. The rate of all mechanical complications was 4.9 % in the TFNA group, 12.9 % in the InterTAN group and 17 % in the IMHS group. Non-union (p < 0.001) and increasing lag screw length (p < 0.02) were identified as risk factors for implant fracture and other mechanical complications. The reverse oblique fracture pattern (AO 31 A3.1) was associated with mechanical complications only (p < 0.01). The cumulative survival rates without revision for the TFNA, InterTAN, IMHS groups were 97.8 %, 95.5 % and 87.9 % respectively at 2.5 years. DISCUSSION: The rates of implant fracture were comparable between the three nailing systems. The TFNA provides effective fixation for proximal femur fractures using a traditional screw without cement augmentation. The TFNA was associated with an overall reduction in mechanical complications compared to the InterTAN and IMHS. Previously reported mechanical complications associated with IM Nails may relate to older device designs.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Proximal Femoral Fractures , Humans , Fracture Fixation, Intramedullary/methods , Bone Nails/adverse effects , Retrospective Studies , Bone Screws
2.
J Pediatr Orthop ; 44(1): 43-48, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37779282

ABSTRACT

BACKGROUND: Magnetically controlled growing rods (MCGR) aim to control curve progression while limiting surgical burden in children with early-onset scoliosis. Systemic and local distribution of metal debris has been documented in children with spinal implants. The aim of the study was to assess serum metal ion levels and local metal debris-related changes at the conclusion of MCGR treatment. METHODS: Between February 2019 and September 2022, all patients who had a conversion to definitive fusion at the completion of MCGR treatment in our institution were invited to participate in this study. Consenting patients had serum metal ion levels drawn (titanium, cobalt, and chromium) and histologic analyses of peri-implant tissue samples. RESULTS: We enrolled 24 children who underwent definitive fusion post-MCGR treatment for early-onset scoliosis. The average age at definitive fusion was 13.3 years (range: 11 to 17 y). The average length of MCGR treatment was 4.8 years (range: 1.5 to 6.8 y). At the end of the MCGR treatment, 23 (96%) patients had elevated serum metal ion levels. Mean serum titanium levels were 165.4 nmol/L (range: 30 to 390 nmol/L), mean serum cobalt levels were 4.6 nmol/L (range: 1.2 to 14 nmol/L), and mean serum chromium levels were 14 nmol/L (range: 2.4 to 30 nmol/L). Peri-implant soft tissue histologic analysis demonstrated local metal debris and foreign body reactions in all patients. CONCLUSIONS: At the completion of MCGR treatment, the majority of patients demonstrate elevated serum metal ion levels and local metal debris-related peri-implant soft tissue changes. Although there is no current literature to suggest these findings are harmful, further research as to the clinical significance is required. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Scoliosis , Child , Humans , Adolescent , Scoliosis/surgery , Titanium , Spine/surgery , Cobalt , Chromium , Retrospective Studies
3.
Arthroplast Today ; 8: 283-288.e1, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34095405

ABSTRACT

We report a case of a fracture through the polyethylene (PE) insert cone in a rotating-platform (RP) primary total knee arthroplasty (TKA) implant. This is the first reported case of cone fracture with this particular implant. This case highlights a 65-year-old female presenting with a 4-month history of knee pain and symptoms of instability 10 years after primary RP TKA. At the time of revision surgery, the PE insert cone was found to be fractured 10 mm from the inferior surface of the PE liner. Analysis suggests that the cone fracture occurred by fatigue failure which caused loosening of the tibial tray. Clinicians should be aware that this is a potential cause of failure with an RP TKA in the setting of symptoms including instability and pain.

4.
Knee Surg Relat Res ; 32(1): 36, 2020 Jul 22.
Article in English | MEDLINE | ID: mdl-32698908

ABSTRACT

INTRODUCTION: Polyethylene (PE) spinout is a known but uncommon complication when using a mobile-bearing (MB) total knee arthroplasty (TKA) design. Sacrificing the posterior cruciate ligament (PCL) is within the manufacturer's recommendations for the Attune® Cruciate-Retaining Rotating-Platform (CR RP) knee design. AIM: To discuss the potential aetiology and prevention of spinout in the Attune® CR RP knee. METHODS: We used a retrospective radiological review from two centres reporting a higher rate of spinout in the Attune® CR RP knee using a cruciate-sacrificing and measured-resection technique when compared to a gap-balancing technique. Three hundred and thirty-two patients were evaluated over a 3-year period. RESULTS: There were 8 out of 279 (2.86%) cases of spinout in our first cohort of patients using a measured-resection technique. There were 0 out of 53 cases of spinout in our second cohort of patients where a gap-balancing technique was used. One spinout was reduced closed, the other seven were initially revised to a thicker RP insert of the same design. Of these seven, three underwent a further revision TKA and one patient required a knee fusion/arthrodesis. CONCLUSIONS: This study reports a higher incidence of PE spinout in the Attune® CR RP TKA when a measured-resection technique in combination with PCL resection is performed. We recommend a gap-balancing technique with conservative soft-tissue release if the surgeon is planning to sacrifice the PCL in the Attune® CR RP.

5.
Ir J Med Sci ; 187(4): 959-963, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29541934

ABSTRACT

INTRODUCTION: General practitioners (GPs) require the necessary skills to identify potentially malignant skin lesions and refer patients in an appropriate and timely manner. We examined the impact of a single consultant delivered education session to GP trainees on their diagnosis of common skin lesions. METHODS: A prospective analysis of baseline knowledge was assessed using a photographic questionnaire. A dedicated education session was delivered by a consultant plastic surgeon. Their knowledge was re-assessed after 3 months. RESULTS: There were 23 participants. Baseline ability to correctly diagnose skin lesions improved significantly at 3 months following dedicated teaching (baseline mean 30.2%, 3-month mean 65.9%, p = 0.001). All trainees recommended that dedicated skin education should be incorporated into GP training curricula. CONCLUSION: Dedicated education sessions on skin lesions can improve the diagnostic accuracy of GP trainees, and we suggest that they are incorporated into the GP training curriculum.


Subject(s)
General Practitioners/trends , Referral and Consultation/trends , Skin Diseases/therapy , Adult , Female , Humans , Male , Prospective Studies , Young Adult
6.
Hip Int ; 27(5): 500-504, 2017 Sep 19.
Article in English | MEDLINE | ID: mdl-28708201

ABSTRACT

INTRODUCTION: Total hip arthroplasty (THA) is a very successful procedure. Revision THA is becoming increasingly common. Recent developments to improve outcomes include the development of large trabecular metal (TM) acetabular cups and augments. There is a paucity of data on the benefit of these new techniques. METHODS: A single-centre retrospective review consisting of a radiological review of post-op revision THA anteroposterior pelvis. Data collection was performed using the Irish National Orthopaedic Register (INOR) and from a previous project. We used a technique developed by Fessy et al in 1999 to measure the centre of rotation (COR) of the hip. We then compared our study to that of a study measuring the COR of healthy native hips. RESULTS: 127 revision THA analysed. Native COR calculated by Fessy et al showed a mean horizontal (x) axis 33.6 mm (standard deviation [SD] 5.74) and a vertical (y) axis 16.4 mm (SD 4.67). Non-TM revisions showed a mean x axis of 29 mm (SD 3.9) and y axis 17.9 (SD 5.9). TM Augments had a mean x axis 29.2 mm (SD 7.9) and y axis of 21.5 (SD 8.4). TM Cups alone had a mean x axis 27 mm (SD 6.9) and y axis 22 mm (SD 10.18). CONCLUSIONS: COR of TM implants showed considerable deviation from the norm. Non-TM implants showed a COR within acceptable physiological range. TM components consistently failed to restore a natural COR in our cohort. The implications of this remain uncertain but must be considered in any decision to use TM.


Subject(s)
Acetabulum/diagnostic imaging , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Metals , Radiography/methods , Acetabulum/surgery , Aged , Cohort Studies , Female , Humans , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies
7.
Clin Invest Med ; 38(3): E110-8, 2015 May 31.
Article in English | MEDLINE | ID: mdl-26026638

ABSTRACT

PURPOSE: Remote ischemic conditioning has been shown to protect against kidney injury in animal and human studies of ischemia-reperfusion. Recent evidence suggests that conditioning may also provide protection against kidney injury caused by contrast medium. The purpose of this study was to determine if conditioning protected against increases in serum creatinine (SCr) after contrast-enhanced computed tomography (CECT). METHODS: A randomised controlled trial (NCT 01741896) was performed with institutional review board approval and informed patient consent. Adult in-patients undergoing abdomino-pelvic CECT were allocated to conditioned or control groups. Conditioning consisted of four cycles of five minutes of cuff-induced arm ischemia with three minutes of reperfusion applied ~40 minutes before CECT. The primary outcome was SCr change after CECT. RESULTS: Baseline characteristics were similar in both groups. For all patients, conditioning reduced the risk ratio (RR) of increased SCr; RR 0.65 (95% confidence intervals 0.41 to 1.04). The protective effect was greater and the evidence for protection stronger when analysis was restricted to patients with pre-scan reduced renal function (eGFR.


Subject(s)
Acute Kidney Injury/prevention & control , Contrast Media/adverse effects , Ischemic Preconditioning/methods , Tomography, X-Ray Computed/adverse effects , Aged , Arm/blood supply , Creatinine/blood , Female , Glomerular Filtration Rate , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...