Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomed Opt ; 14(3): 030501, 2009.
Article in English | MEDLINE | ID: mdl-19566285

ABSTRACT

Tomographic imaging of a glioma tumor with endogenous fluorescence is demonstrated using a noncontact single-photon counting fan-beam acquisition system interfaced with microCT imaging. The fluorescence from protoporphyrin IX (PpIX) was found to be detectable, and allowed imaging of the tumor from within the cranium, even though the tumor presence was not visible in the microCT image. The combination of single-photon counting detection and normalized fluorescence to transmission detection at each channel allowed robust imaging of the signal. This demonstrated use of endogenous fluorescence stimulation from aminolevulinic acid (ALA) and provides the first in vivo demonstration of deep tissue tomographic imaging with protoporphyrin IX.


Subject(s)
Brain Neoplasms/diagnostic imaging , Fluorescence , Glioma/diagnostic imaging , X-Ray Microtomography/methods , Aminolevulinic Acid , Animals , Humans , Photosensitizing Agents , Protoporphyrins , Rats , Transplantation, Heterologous
2.
Appl Opt ; 46(10): 1669-78, 2007 Apr 01.
Article in English | MEDLINE | ID: mdl-17356609

ABSTRACT

Subsurface tomography with diffuse light has been investigated with a noncontact approach to characterize the performance of absorption and fluorescence imaging. Using both simulations and experiments, the reconstruction of local subsurface heterogeneity is demonstrated, but the recovery of target size and fluorophore concentration is not linear when changes in depth occur, whereas the mean position of the object for experimental fluorescent and absorber targets is accurate to within 0.5 and 1.45 mm when located within the first 10 mm below the surface. Improvements in the linearity of the response with depth appear to remain challenging and may ultimately limit the approach to detection rather than characterization applications. However, increases in tissue curvature and/or the addition of prior information are expected to improve the linearity of the response. The potential for this type of imaging technique to serve as a surgical guide is highlighted.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Microscopy, Fluorescence/methods , Tomography, Optical/methods , Computer Simulation , Microscopy, Fluorescence/instrumentation , Models, Biological , Nonlinear Dynamics , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Tomography, Optical/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...