Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Nanomaterials (Basel) ; 13(16)2023 Aug 18.
Article in English | MEDLINE | ID: mdl-37630958

ABSTRACT

Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO2/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 µg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 µg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics.

2.
Sensors (Basel) ; 23(3)2023 Jan 28.
Article in English | MEDLINE | ID: mdl-36772475

ABSTRACT

A measurement system based on the colossal magnetoresistance CMR-B-scalar sensor was developed for the measurement of short-duration high-amplitude magnetic fields. The system consists of a magnetic field sensor made from thin nanostructured manganite film with minimized memory effect, and a magnetic field recording module. The memory effect of the La1-xSrx(Mn1-yCoy)zO3 manganite films doped with different amounts of Co and Mn was investigated by measuring the magnetoresistance (MR) and resistance relaxation in pulsed magnetic fields up to 20 T in the temperature range of 80-365 K. It was found that for low-temperature applications, films doped with Co (LSMCO) are preferable due to the minimized magnetic memory effect at these temperatures, compared with LSMO films without Co. For applications at temperatures higher than room temperature, nanostructured manganite LSMO films with increased Mn content above the stoichiometric level have to be used. These films do not exhibit magnetic memory effects and have higher MR values. To avoid parasitic signal due to electromotive forces appearing in the transmission line of the sensor during measurement of short-pulsed magnetic fields, a bipolar-pulsed voltage supply for the sensor was used. For signal recording, a measurement module consisting of a pulsed voltage generator with a frequency up to 12.5 MHz, a 16-bit ADC with a sampling rate of 25 MHz, and a microprocessor was proposed. The circuit of the measurement module was shielded against low- and high-frequency electromagnetic noise, and the recorded signal was transmitted to a personal computer using a fiber optic link. The system was tested using magnetic field generators, generating magnetic fields with pulse durations ranging from 3 to 20 µs. The developed magnetic field measurement system can be used for the measurement of high-pulsed magnetic fields with pulse durations in the order of microseconds in different fields of science and industry.

3.
Sensors (Basel) ; 22(11)2022 May 25.
Article in English | MEDLINE | ID: mdl-35684630

ABSTRACT

The results of colossal magnetoresistance (CMR) properties of La1-xSrxMnyO3 (LSMO) films grown by the pulsed injection MOCVD technique onto an Al2O3 substrate are presented. The grown films with different Sr (0.05 ≤ x ≤ 0.3) and Mn excess (y > 1) concentrations were nanostructured with vertically aligned column-shaped crystallites spread perpendicular to the film plane. It was found that microstructure, resistivity, and magnetoresistive properties of the films strongly depend on the strontium and manganese concentration. All films (including low Sr content) exhibit a metal−insulator transition typical for manganites at a certain temperature, Tm. The Tm vs. Sr content dependence for films with a constant Mn amount has maxima that shift to lower Sr values with the increase in Mn excess in the films. Moreover, the higher the Mn excess concentration in the films, the higher the Tm value obtained. The highest Tm values (270 K) were observed for nanostructured LSMO films with x = 0.17−0.18 and y = 1.15, while the highest low-field magnetoresistance (0.8% at 50 mT) at room temperature (290 K) was achieved for x = 0.3 and y = 1.15. The obtained low-field MR values were relatively high in comparison to those published in the literature results for lanthanum manganite films prepared without additional insulating oxide phases. It can be caused by high Curie temperature (383 K), high saturation magnetization at room temperature (870 emu/cm3), and relatively thin grain boundaries. The obtained results allow to fabricate CMR sensors for low magnetic field measurement at room temperature.

4.
Sensors (Basel) ; 22(2)2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35062569

ABSTRACT

The results of colossal magnetoresistance (CMR) properties of La0.83Sr0.17Mn1.21O3 (LSMO) films grown by pulsed injection MOCVD technique onto various substrates are presented. The films with thicknesses of 360 nm and 60 nm grown on AT-cut single crystal quartz, polycrystalline Al2O3, and amorphous Si/SiO2 substrates were nanostructured with column-shaped crystallites spread perpendicular to the film plane. It was found that morphology, microstructure, and magnetoresistive properties of the films strongly depend on the substrate used. The low-field MR at low temperatures (25 K) showed twice higher values (-31% at 0.7 T) for LSMO/quartz in comparison to films grown on the other substrates (-15%). This value is high in comparison to results published in literature for manganite films prepared without additional insulating oxides. The high-field MR measured up to 20 T at 80 K was also the highest for LSMO/quartz films (-56%) and demonstrated the highest sensitivity S = 0.28 V/T at B = 0.25 T (voltage supply 2.5 V), which is promising for magnetic sensor applications. It was demonstrated that Mn excess Mn/(La + Sr) = 1.21 increases the metal-insulator transition temperature of the films up to 285 K, allowing the increase in the operation temperature of magnetic sensors up to 363 K. These results allow us to fabricate CMR sensors with predetermined parameters in a wide range of magnetic fields and temperatures.

5.
Sensors (Basel) ; 20(20)2020 Oct 20.
Article in English | MEDLINE | ID: mdl-33092215

ABSTRACT

The possibility of applying CMR-B-scalar sensors made from thin manganite films exhibiting the colossal magnetoresistance effect as a fast-nondestructive method for the evaluation of the quality of the magnetic pulse welding (MPW) process is investigated in this paper. This method based on magnetic field magnitude measurements in the vicinity of the tools and joining parts was tested during the electromagnetic compression and MPW of an aluminum flyer tube with a steel parent. The testing setup used for the investigation allowed the simultaneous measurement of the flyer displacement, its velocity, and the magnitude of the magnetic field close to the flyer. The experimental results and simulations showed that, during the welding of the aluminum tube with the steel parent, the maximum magnetic field in the gap between the field shaper and the flyer is achieved much earlier than the maximum of the current pulse of the coil and that the first half-wave pulse of the magnetic field has two peaks. It was also found that the time instant of the minimum between these peaks depends on the charging energy of the capacitors and is associated with the collision of the flyer with the parent. Together with the first peak maximum and its time-position, this characteristic could be an indication of the welding quality. These results were confirmed by simultaneous measurements of the flyer displacement and velocity, as well as a numerical simulation of the magnetic field dynamics. The relationship between the peculiarities of the magnetic field pulse and the quality of the welding process is discussed. It was demonstrated that the proposed method of magnetic field measurement during magnetic pulse welding in combination with subsequent peel testing could be used as a nondestructive method for the monitoring of the quality of the welding process.

6.
Sci Rep ; 9(1): 9497, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31263164

ABSTRACT

The demand to increase the sensitivity to magnetic field in a broad magnetic field ranges has led to the research of novel materials for sensor applications. Therefore, the hybrid system consisting of two different magnetoresistive materials - nanostructured Co-doped manganite La1-xSrx(Mn1-yCoy)zO3 and single- and few-layer graphene - were combined and investigated as potential system for magnetic field sensing. The negative colossal magnetoresistance (CMR) of manganite-cobaltite and positive one of graphene gives the possibility to increase the sensitivity to magnetic field of the hybrid sensor. The performed magnetoresistance (MR) measurements of individual few layer (n = 1-5) graphene structures revealed the highest MR values for three-layer graphene (3LG), whereas additional Co-doping increased the MR values of nanostructured manganite films. The connection of 3LG graphene and Co-doped magnanite film in a voltage divider configuration significantly increased the sensitivity of the hybrid sensor at low and intermediate magnetic fields (1-2 T): 70 mV/VT of hybrid sensor in comparison with 56 mV/VT for 3LG and 12 mV/VT for Co-doped magnanite film, respectively, and broadened the magnetic field operation range (0.1-20) T of the produced sensor prototype.

7.
Nanotechnology ; 30(35): 355503, 2019 Aug 30.
Article in English | MEDLINE | ID: mdl-31067515

ABSTRACT

An increasing demand of magnetic field sensors with high sensitivity at room temperatures and spatial resolution at micro-nanoscales has resulted in numerous investigations of physical phenomena in advanced materials, and fabrication of novel magnetoresistive devices. In this study the novel magnetic field sensor based on combination of a single layer graphene (SLG) and thin nanostructured manganite La0.8Sr0.2MnO3 (LSMO) film-hybrid graphene-manganite (GM) structure, is proposed and fabricated. The hybrid GM structure employs the properties of two materials-SLG and LSMO-on the nanoscale level and results in the enhanced sensitivity to magnetic field of the hybrid sensor on the macroscopic level. Such result is achieved by designing the hybrid GM sensor in a Wheatstone half-bridge which enables to employ in the device operation two effects of nanomaterials-large Lorentz force induced positive magnetoresistance of graphene and colossal negative magnetoresistance of nanostructured manganite film, and significantly increase the sensitivity S of the hybrid GM sensor in comparison with the individual SLG and LSMO sensors: S = 5.5 mV T-1 for SLG, 14.5 mV T-1 for LSMO and 20 mV T-1 for hybrid GM at 0.5 T, when supply voltage was 1.249 V. The hybrid GM sensor operates in the range of (0.1-2.3) T and has lower sensitivity to temperature variations in comparison to the manganite sensor. Moreover, it can be applied for position sensing. The ability to control sensor's characteristics by changing technological conditions of the fabrication of hybrid structure and tuning the nanostructure properties of manganite film is discussed.

8.
Beilstein J Nanotechnol ; 10: 256-261, 2019.
Article in English | MEDLINE | ID: mdl-30746319

ABSTRACT

In the present study the advantageous pulsed-injection metal organic chemical vapour deposition (PI-MOCVD) technique was used for the growth of nanostructured La1- x Sr x Mn y O3±Î´ (LSMO) films on ceramic Al2O3 substrates. The compositional, structural and magnetoresistive properties of the nanostructured manganite were changed by variation of the processing conditions: precursor solution concentration, supply frequency and number of supply sources during the PI-MOCVD growth process. The results showed that the thick (≈400 nm) nanostructured LSMO films, grown using an additional supply source of precursor solution in an exponentially decreasing manner, exhibit the highest magnetoresistance and the lowest magnetoresistance anisotropy. The possibility to use these films for the development of magnetic field sensors operating at room temperature is discussed.

9.
Int J Food Microbiol ; 291: 128-134, 2019 Feb 16.
Article in English | MEDLINE | ID: mdl-30496942

ABSTRACT

Prospects of pulsed electric field technology application on acid whey concentrate pretreatment were analyzed. Stationary and flow pre-treatment systems were combined with different treatment parameters: electric field strength (E = 39 kV/cm, 95 kV/cm, 92 kV/cm), pulse duration (τ = 60 ns, 90 ns, 1000 ns) and pulse number (pn = up to 100 pulses). Isolates of Saccharomyces sp. and Lactobacillus sp. were predominant in concentrate. Significant non-thermal inactivation effect was achieved after PEF treatment. Exposure to short pulses selectively inactivated yeast cells, as a result PEF technology can be applied for low-energy acid whey processing.


Subject(s)
Electricity , Food Contamination/prevention & control , Food Microbiology , Lactobacillus , Saccharomyces/physiology , Whey/microbiology , Electroporation , Food Preservation , Microbial Viability
10.
Bioelectrochemistry ; 115: 19-25, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28236755

ABSTRACT

Saccharomyces cerevisiae yeast cells were used as a model organism to investigate the effects of various pulsed electric fields on the programed death of such cells. These were exposed to electric field pulses with field strengths (E) of up to 220kV/cm. The effects of square shaped pulses having different durations (τ=10-90ns) and different pulse numbers (pn=1-5) were then analysed. The obtained results show that nanosecond pulses can induce the death of such cells, which in turn is dependent on the electric field pulse parameters and increase with the rise in E, τ and pn. The decrease of the cells' viability was accompanied by an increase in the active form of intracellular yeast metacaspases. It was thus shown that nanosecond electric field pulses induced the caspase-dependent yeast cell death.


Subject(s)
Caspases/metabolism , Electroporation/methods , Saccharomyces cerevisiae/cytology , Apoptosis , Biomarkers/analysis , DNA Fragmentation , Electromagnetic Fields , Electroporation/instrumentation , Equipment Design , Phosphatidylserines/metabolism , Saccharomyces cerevisiae/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...