Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
World J Biol Psychiatry ; 10(4 Pt 2): 552-9, 2009.
Article in English | MEDLINE | ID: mdl-18609429

ABSTRACT

Hwa-Byung (HB) is a Korean culture-bound psychiatric syndrome caused by the suppression of anger. HB patients have various psychological and somatic symptoms, such as chest discomfort, a sensation of heat, and the sensation of having an epigastric mass. In this study, we measured brain activity in HB patients and healthy individuals in response to affective facial stimuli. Using functional magnetic resonance imaging (fMRI), the current study measured neural responses to neutral, sad, and angry facial stimuli in 12 healthy individuals and 12 patients with HB. In response to all types of facial stimuli, HB patients showed increased activations in the lingual gyrus and fusiform gyrus compared with healthy persons, but they showed relatively lower activation in the thalamus. We also found that patients with HB showed lower activity in response to the neutral condition in the right ACC than healthy controls. The current study indicates that the suppression of affect results in aberrant function of the brain regions of the visual pathway, and functional impairment in the ACC may contribute to the pathophysiology of HB.


Subject(s)
Affect/physiology , Brain/physiopathology , Cross-Cultural Comparison , Facial Expression , Magnetic Resonance Imaging , Pattern Recognition, Visual/physiology , Recognition, Psychology/physiology , Somatoform Disorders/physiopathology , Adult , Anger/physiology , Brain Mapping , Cerebral Cortex/physiopathology , Female , Gyrus Cinguli/physiopathology , Humans , Middle Aged , Reference Values , Republic of Korea , Somatoform Disorders/psychology , Syndrome , Thalamus/physiopathology , Visual Pathways/physiopathology
2.
Inhal Toxicol ; 20(12): 1075-83, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18728992

ABSTRACT

The shortening of the MRI T1 relaxation time, indicative of a high signal intensity in a T1-weighted MRI, is known as a useful biomarker for Mn exposure after short-term welding-fume exposure. A previous monkey experimental study found that the T1 relaxation times decreased time-dependently after exposure, and a visually detectable high signal intensity appeared after 150 days of exposure. The nadir for the shortening of the T1 relaxation time was also previously found to correspond well with the blood Mn concentration in welders, suggesting a correlation between a prolonged high blood Mn concentration and shortened T1 relaxation time. Accordingly, to clarify the clearance of the brain Mn concentration after the cessation of welding-fume exposure, cynomolgus monkeys were assigned to 3 groups-unexposed, low dose (31 mg/m(3) total suspended particulate (TSP), 0.9 mg Mn/m(3)), and high dose (62 mg/m(3) TSP, 1.95 mg Mn/m(3))-and exposed to manual metal-arc stainless steel (MMA-SS) welding fumes for 2 h per day for 8 mo in an inhalation chamber system equipped with an automatic fume generator. After reaching the peak MRI T1 signal intensity (shortest T1 relaxation time), the monkeys were allowed to recover by ceasing the welding-fume exposure. Within 2 mo, the MRI T1 signal intensities for the exposed monkeys returned to nearly the same level as those for the unexposed monkeys, indicating the potential for recovery from a high MRI T1 signal intensity induced by welding-fume exposure, even after prolonged exposure. Clearance of the Mn tissue concentration was also demonstrated in the globus pallidus, plus other tissues from the brain, liver, spleen, and blood. In contrast, there was no clearance of the lung concentrations of Mn, indicating that a soluble form of Mn was transported to the blood and brain. Therefore, the solubility of Mn in welding fumes would appear to be an important determinant as regards the retention of blood Mn levels and brain tissue Mn concentrations in welders.


Subject(s)
Air Pollutants, Occupational/toxicity , Brain/metabolism , Inhalation Exposure/adverse effects , Magnetic Resonance Imaging/methods , Welding/methods , Air Pollutants, Occupational/blood , Animals , Brain/drug effects , Macaca fascicularis , Male , Manganese/blood , Manganese/toxicity , Time Factors
3.
Neuroreport ; 19(10): 1021-5, 2008 Jul 02.
Article in English | MEDLINE | ID: mdl-18580572

ABSTRACT

We investigated the neural basis underlying the effect of race on incidental facial emotional processing using functional MRI. Thirteen healthy Korean men underwent functional MRI while viewing photographs of Korean (own-race) and Caucasian (other-race) emotional faces while performing a sex discrimination task. Responses to other-race relative to own-race neutral faces replicated previous studies: activations were obtained in dorsolateral prefrontal cortex/medial frontal cortex. Direct contrasts between-race emotional faces (happy and sad) also showed differential effects: the contrast of own-race relative to other-race had more activations in limbic areas (amygdala and hippocampus), whereas the contrast of other-race relative to own-race had more activations in frontal, occipital, and parietal lobes. Our findings provide evidence for differential processing of emotional faces as a function of race.


Subject(s)
Brain Mapping , Emotions/physiology , Face , Facial Expression , Pattern Recognition, Visual/physiology , Adult , Brain/blood supply , Brain/physiology , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/methods , Male , Oxygen/blood , Photic Stimulation
4.
Inhal Toxicol ; 19(11): 965-71, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17849280

ABSTRACT

Several pharmacokinetic studies on inhalation exposure to manganese (Mn) have already demonstrated that Mn readily accumulates in the olfactory and brain regions. However, a shortening of the magnetic resonance imaging (MRI) T1 relaxation time or high T1 signal intensity in specific sites of the brain, including the globus pallidus and subcortical frontal white matter, as indicative of tissue manganese accumulation has not yet been clearly established for certain durations of known doses of welding-fume exposure in experimental animals. Accordingly, to investigate the movement of manganese after welding-fume exposure, six cynomolgus monkeys were acclimated and assigned to three dose groups: unexposed, low dose (31 mg/m(3) total suspended particulate [TSP], 0.9 mg/m(3) of Mn), and high dose (62 mg/m(3) TSP, 1.95 mg/m(3) of Mn) of total suspended particulate. The primates were exposed to manual metal arc stainless steel (MMA-SS) welding fumes for 2 h per day in an inhalation chamber system equipped with an automatic fume generator. Magnetic resonance imaging (MRI) studies were conducted before the initiation of exposure and thereafter every month. The tissue Mn concentrations were then measured after a plateau was reached regarding the shortening of the MRI T1 relaxation time. A dose-dependent increase in the Mn concentration was found in the lungs, while noticeable increases in the Mn concentrations were found in certain tissues, such as the liver, kidneys, and testes. Slight increases in the Mn concentrations were found in the caudate, putamen, frontal lobe, and substantia nigra, while a dose-dependent noticeable increase was only found in the globus pallidus. Therefore, the present results indicated that a shortening of the MRI T1 relaxation time corresponded well with the Mn concentration in the globus pallidus after prolonged welding-fume exposure.


Subject(s)
Air Pollutants, Occupational/pharmacokinetics , Brain/metabolism , Magnetic Resonance Imaging/methods , Manganese/metabolism , Stainless Steel/pharmacokinetics , Welding , Air Pollutants, Occupational/adverse effects , Animals , Atmosphere Exposure Chambers/adverse effects , Globus Pallidus/metabolism , Macaca fascicularis , Male , Manganese/administration & dosage , Stainless Steel/adverse effects , Time
5.
Neurotoxicology ; 28(2): 284-9, 2007 Mar.
Article in English | MEDLINE | ID: mdl-16828869

ABSTRACT

Magnetic resonance (MR) imaging has become a useful tool for the estimation of occupational exposure to manganese (Mn). However, validity of signal indices on T1-weighted imaging, a proxy measurement of T1 relaxation time shortening due to Mn deposition, needs to be evaluated in an occupationally exposed population. We performed MR imaging on 20 male welders and 10 age- and gender-matched, non-office workers in a shipyard. We measured the relative signal intensity ratio of the globus pallidus (GP) to the frontal white matter on T1-weighted MR images (pallidal index, PI). We also assessed the visual scale for the relative signal intensity of the GP, which was graded as 0-2 by a radiologist. We evaluated both signal index and visual scale in relation to the T1 relaxation time measured at the GP. Both PI and T1 relaxation time were significantly increased in the welders compared to the non-welders. T1 relaxation time began to decrease from visual scale 2, while PI began to increase from visual scale 1. Environmental Mn exposure indices correlated well with both T1 relaxation time and PI. However, blood Mn level correlated only with T1 relaxation time, and not with PI. T1 relaxation time correlated with PI only at the higher level of PI. These results indicate the possible inaccuracy of visual scoring and the discrepancy between T1 relaxation time and PI, especially at the lower level of signal intensity. Although both T1 and PI are good biomarkers for the environmental Mn exposure, non-linearity of the relationship between T1 and PI must be considered in the assessment of Mn exposure using MRI.


Subject(s)
Air Pollutants/adverse effects , Environmental Monitoring/methods , Globus Pallidus/drug effects , Magnetic Resonance Imaging , Manganese Compounds/adverse effects , Occupational Exposure , Welding , Adult , Case-Control Studies , Dose-Response Relationship, Drug , Globus Pallidus/pathology , Humans , Korea , Male , Manganese/blood , Middle Aged , Protons , Reproducibility of Results , Signal Processing, Computer-Assisted , Time Factors
6.
Inhal Toxicol ; 19(1): 47-55, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17127642

ABSTRACT

Welders are at risk of being exposed to high concentrations of welding fumes and developing pneumoconiosis or other welding-fume exposure-related diseases. Among such diseases, manganism resulting from welding-fume exposure remains a controversial issue, as although the movement of manganese into specific brain regions has been established, the similar movement of manganese presented with other metals, such as welding fumes, has not been clearly demonstrated as being similar to that of manganese alone. Meanwhile, the competition between Mn and iron for iron transporters, such as transferrin and DMT-1, to the brain has also been implicated in the welding-fume exposure. Thus, the increased signal intensities in the basal ganglia, including the globus pallidus and subcortical frontal white matter, based on T1-weighted magnetic resonances in welders, require further examination as regards the correspondence with an increased manganese concentration. Accordingly, to investigate the movement of manganese after welding-fume exposure, 6 cynomolgus monkeys were acclimated for 1 mo and assigned to 3 dose groups: unexposed, low dose of (total suspended particulate [TSP] 31 mg/m3, 0.9 mg/m3 of Mn), and high dose of total suspended particulate (62 mg/m3 TSP, 1.95 mg/m3 of Mn). The primates were exposed to manual metal-arc stainless steel (MMA-SS) welding fumes for 2 h/day in an inhalation chamber system equipped with an automatic fume generator for 6 mo. Magnetic resonance imaging (MRI) studies of the basal ganglia were conducted before the initiation of exposure and thereafter every month. During the exposure, the blood chemistry was monitored every 2 wk and the concentrations of metal components in the blood were measured every 2 wk and compared with ambient manganese concentrations. The manganese concentrations in the blood did not show any significant increase until after 2 mo of exposure, and then reached a plateau after 90 days of exposure, showing that an exposure period of at least 60 days was required to build up the blood Mn concentration. Furthermore, as the blood Mn concentration continued to build, a continued decrease in the MRI T1 relaxation time in the basal ganglia was also detected. These data suggested that prolonged inhalation of welding fumes induces a high MRI T1 signal intensity with an elevation of the blood manganese level. The presence of a certain amount of iron or other metals, such as Cr and Ni, in the inhaled welding fumes via inhalation was not found to have a significant effect on the uptake of Mn into the brain or the induction of a high MRI T1 signal intensity.


Subject(s)
Basal Ganglia/drug effects , Inhalation Exposure , Magnetic Resonance Imaging , Manganese , Particulate Matter/toxicity , Stainless Steel , Welding , Air Pollutants, Occupational/chemistry , Air Pollutants, Occupational/toxicity , Animals , Atmosphere Exposure Chambers , Basal Ganglia/metabolism , Chromium/analysis , Chromium/blood , Dose-Response Relationship, Drug , Iron/analysis , Iron/blood , Macaca fascicularis , Male , Manganese/analysis , Manganese/blood , Manganese/metabolism , Nickel/analysis , Particulate Matter/chemistry , Time Factors
7.
IEEE Trans Med Imaging ; 21(6): 695-702, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12166867

ABSTRACT

Recently, a new static resistivity image reconstruction algorithm is proposed utilizing internal current density data obtained by magnetic resonance current density imaging technique. This new imaging method is called magnetic resonance electrical impedance tomography (MREIT). The derivation and performance of J-substitution algorithm in MREIT have been reported as a new accurate and high-resolution static impedance imaging technique via computer simulation methods. In this paper, we present experimental procedures, denoising techniques, and image reconstructions using a 0.3-tesla (T) experimental MREIT system and saline phantoms. MREIT using J-substitution algorithm effectively utilizes the internal current density information resolving the problem inherent in a conventional EIT, that is, the low sensitivity of boundary measurements to any changes of internal tissue resistivity values. Resistivity images of saline phantoms show an accuracy of 6.8%-47.2% and spatial resolution of 64 x 64. Both of them can be significantly improved by using an MRI system with a better signal-to-noise ratio.


Subject(s)
Algorithms , Electric Impedance , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Tomography/methods , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Tomography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...