Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Open Access Emerg Med ; 10: 37-45, 2018.
Article in English | MEDLINE | ID: mdl-29719423

ABSTRACT

OBJECTIVE: Laboratory tests are an important contributor to treatment decisions in the emergency department (ED). Rapid turnaround of laboratory tests can optimize ED throughout by reducing the length of stay (LOS) and improving patient outcomes. Despite evidence supporting the effect of shorter turnaround time (TAT) on LOS and outcomes, there is still a lack of large retrospective studies examining these associations. Here, we evaluated the effect of a reduction in laboratory TAT on ED LOS using retrospective analysis of Electronic Health Records (EHR). MATERIALS AND METHODS: Retrospective analysis of ED encounters from a large, US-based, de-identified EHR database and a separate analysis of ED encounters from the EHR of an ED at a top-tier tertiary care center were performed. Additionally, an efficiency model calculating the cumulative potential LOS time savings and resulting financial opportunity due to laboratory TAT reduction was created, assuming other factors affecting LOS are constant. RESULTS: Multivariate regression analysis of patients from the multisite study showed that a 1-minute decrease in laboratory TAT was associated with 0.50 minutes of decrease in LOS. The single-site analysis confirmed our findings from the multisite analysis that a positive correlation between laboratory TAT and ED LOS exists in the ED population as a whole, as well as across different patient acuity levels. In addition, based on the calculations from the efficiency model, for a 5-, 10- and 15-minute TAT reduction, the single-site ED can potentially admit a total of 127, 256 and 386 additional patients, respectively, annually. CONCLUSION: A positive correlation between laboratory TAT and ED LOS was observed in a broad patient population and across distinct acuity levels.

2.
Pharmacoecon Open ; 2(3): 325-335, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29623629

ABSTRACT

BACKGROUND: There is growing evidence of the benefits of intravenous fluid therapy with balanced crystalloids over 0.9% 'normal' saline. This analysis evaluated the economic impact of increasing usage of a calcium-free balanced crystalloid solution (BAL) in patients with systemic inflammatory response syndrome (SIRS) on an annual hospital budget. METHODS: An Excel®-based economic model was developed to estimate costs associated with increased BAL usage (i.e., use in a greater proportion of patients), from the US hospital perspective, over a 5-year time horizon. Clinical inputs were based on the results of a retrospective Electronic Health Record (EHR) database analysis identifying significantly fewer complications among SIRS patients receiving predominantly BAL versus saline. Complication-associated costs, adjusted to 2015, were obtained from published reports. Scenario analyses examined cost impacts for hospitals of various sizes, with different BAL adoption levels and rates. RESULTS: Base-case scenario analysis (300-bed hospital, 80% occupancy, current and year 5 BAL usage in 5 and 75% of SIRS patients, respectively, exponential year-over-year adoption) showed year 1 hospital savings of US$29,232 and cumulative 5-year savings of US$1.16M. Cumulative 5-year pharmacy savings were US$172,641. Scenario analyses demonstrated increasing cumulative 5-year savings with increasing hospital size, year 5 BAL usage in greater proportions of patients, and rapid/early BAL adoption. CONCLUSIONS: Increased BAL usage represents an opportunity for hospitals and pharmacy departments to reduce complication-related costs associated with managing SIRS patients. The model suggests that savings could be expected across a range of scenarios, likely benefiting hospitals of various sizes and with different adoption capabilities.

3.
Ann Clin Biochem ; 54(2): 230-239, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27166314

ABSTRACT

Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.


Subject(s)
Blood Specimen Collection/standards , Chemistry, Clinical/economics , Clinical Laboratory Services/economics , Blood Specimen Collection/economics , Chemistry, Clinical/methods , Europe , Fibrin/chemistry , Fibrin/isolation & purification , Gels , Humans , Laboratories , North America , Oceania , Quality Control , Surveys and Questionnaires
4.
Structure ; 20(6): 1071-85, 2012 Jun 06.
Article in English | MEDLINE | ID: mdl-22632835

ABSTRACT

Structural consequences of ionization of residues buried in the hydrophobic interior of proteins were examined systematically in 25 proteins with internal Lys residues. Crystal structures showed that the ionizable groups are buried. NMR spectroscopy showed that in 2 of 25 cases studied, the ionization of an internal Lys unfolded the protein globally. In five cases, the internal charge triggered localized changes in structure and dynamics, and in three cases, it promoted partial or local unfolding. Remarkably, in 15 proteins, the ionization of the internal Lys had no detectable structural consequences. Highly stable proteins appear to be inherently capable of withstanding the presence of charge in their hydrophobic interior, without the need for specialized structural adaptations. The extent of structural reorganization paralleled loosely with global thermodynamic stability, suggesting that structure-based pK(a) calculations for buried residues could be improved by calculation of thermodynamic stability and by enhanced conformational sampling.


Subject(s)
Bacterial Proteins/chemistry , Micrococcal Nuclease/chemistry , Amino Acid Motifs , Amino Acid Substitution , Bacterial Proteins/genetics , Crystallography, X-Ray , Enzyme Stability , Hydrogen Bonding , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Micrococcal Nuclease/genetics , Models, Molecular , Mutagenesis, Site-Directed , Nuclear Magnetic Resonance, Biomolecular , Protein Structure, Tertiary , Protein Unfolding , Staphylococcus aureus/enzymology , Thermodynamics