Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Mol Imaging Radionucl Ther ; 33(2): 106-108, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38949459

ABSTRACT

Tc-99m methylene diphosphonate (MDP) is a bone imaging agent used for skeletal staging, but it can also be localized in extraosseous calcifying lesions. We report a case of an 84-year-old woman with breast carcinoma who underwent surgery followed by radiotherapy 10 years ago and now presented with a right axillary mass referred for Tc-99m MDP to exclude bone metastasis. Tc-99m MDP shows intense tracer uptake in the right thoracic region corresponding to the site of calcified soft tissue mass in the right lateral chest wall. Subsequent ultrasonography revealed an ill-defined lesion containing coarse calcifications. Biopsy showed radiation-induced sarcoma. Extra osseous Tc-99m MDP uptake may provide important diagnostic information that may alter patient management.

2.
Indian J Nucl Med ; 36(2): 120-124, 2021.
Article in English | MEDLINE | ID: mdl-34385781

ABSTRACT

INTRODUCTION: [18F]-Fluorodeoxyglucose ([18F]-FDG) is the most widely used positron-emission tomography tracer used for imaging in clinical studies such as early detection of cancer or its malignancies, quantifications, staging, and restaging of several malignancies. For clinical application, routine production of this tracer is mandatory in compliance to regulatory guidelines. Several dedicated commercial synthesizers are currently used for producing[18F]-FDG for clinical usage. Being at hospital radiopharmacy, it is our responsibility and duty to support the clinical service with uninterrupted production and supply of [18F]-FDG. This document describes the production of [18F]-FDG using two different automated synthesizers in terms of its production yield, time of synthesis, and analyze the quality control (QC) of the produced [18F]-FDG. MATERIALS AND METHODS: The precursor, mannose triflate ultra-pure, authentic nonradioactive standard FDG and [18O]-water were obtained from ABX, Germany. Solvents and reagents were purchased from Sigma Aldrich India Ltd. and Fisher Scientific India Ltd., (Mumbai, Maharashtra, India). RESULTS: The protocol developed for the synthesis with MPS-100 synthesizer yield of [18F]-FDG is approximate about 45% End of Bombardment (EOB) with synthesis time of around 35 min, whereas with F300E synthesizer it is around 60% with synthesis time of 25 min. The quality of the tracer produced by both synthesizers is at par with the QC parameter for clinical applications. CONCLUSIONS: Finally, we have developed the production using two automated synthesis modules which have the capability to produce [18F]-FDG, to do the patient studies in good yield and purity. Our protocol is simple, reproducible, and robust.

3.
Indian J Nucl Med ; 36(2): 148-152, 2021.
Article in English | MEDLINE | ID: mdl-34385785

ABSTRACT

AIM: Radionuclide therapy may produce a significant radiation exposure risk to the patient's caregivers. The study aims to assess the radiation exposure rate to caregivers after the patient's discharge from the isolation ward. MATERIALS AND METHODS: Patients of the well-Differentiated thyroid cancer (DTC)were given high-dose radioiodine therapy as an inpatient. Their radiation exposure was measured daily, and they were discharged once the exposure rate falls as per standard guidelines. Detail counseling of the patient and caregiver about radiation safety was done before admission and at the time of discharge. Caregivers were given thermoluminescence dosimeter (TLD) to wear as a locket for 7 days. Radiation exposure received by the caregiver was measure after that. RESULTS: A total of 22 patients (8 male and 14 female) of DTC were recruited in the study. The mean age was 39.0 ± 14.5 years. Patients were treated with 3.79 ± 1.07 (102.4 ± 28.9 mCi) (1.85-5.55 (50-150 mCi) GBq of radioiodine. They were discharged from the isolation ward at a radiation level of 0.028 ± 0.015 mSv/h (3.193 ± 1.71 mR). The mean effective dose received by the caregiver was 14.60 ± 3.43 mSv (1460 ± 343 mR) (9.73-24.25 (973-2765 mR) mSv. CONCLUSION: Our study denotes that the caregivers of DTC patients receive a significant radiation dose. It was well above the caregiver's annual dose-limit constraints regarding the rationales well as international guidelines of 5 mSv/yr. These could be related to the long travel in public transport and housing conditions. There is a need for patient-specific discharge criteria rather than following standard guidelines to minimize radiation exposure to caregivers.

4.
Indian J Nucl Med ; 35(2): 130-135, 2020.
Article in English | MEDLINE | ID: mdl-32351267

ABSTRACT

BACKGROUND/AIMS: Esophageal transit scintigraphy (ETS) is a useful tool for evaluating esophageal motility disorders, although conflicting results are seen due to lack of ideal bolus. Semisolid/solid boluses have shown superiority over liquid boluses, and the present study aims to establish the utility of in-house-prepared bolus in normal volunteers and its comparison with liquid bolus. MATERIALS AND METHODS: Thirty-three healthy volunteers were selected for ETS with in-house-prepared semisolid bolus jelly containing 99mTc-sulfur colloid. Dynamic studies were acquired in anterior projection with single swallow for both supine and sitting positions. T90% esophageal emptying time (EET) was calculated for whole and three equally divided segments of esophagus and also done with liquid bolus on different day. RESULTS: The median value of EET for semisolid bolus for whole esophagus in sitting and supine positions was 11.7 s (interquartile range [IQR]: 8.0-16.7) and 17.7 s (IQR: 12.0-33.0). EET of liquid bolus for whole esophagus in sitting and supine positions was 9.3 s (IQR: 8.0-13.3) and 13.0 s (IQR: 9.7-25.0), respectively. Significantly different EET for whole esophagus and lower one-third esophagus between sitting and supine positions was seen for semisolid (whole esophagus;P = 0.003, lower one-third esophagus; P = 0.025) and liquid boluses (whole esophagus; P = 0.032, lower one-third esophagus; P = 0.016). Comparing EET using semisolid and liquid boluses, only lower one-third esophagus in supine position showed significant difference (P = 0.033). CONCLUSIONS: In-house-prepared semisolid radiolabeled jelly is inexpensive, easy to prepare with good radiolabeling. Condensed dynamic images from semisolid bolus were better, sharper, and reproducible in comparison to liquid bolus without fragmentation. This study standardized semisolid bolus and verified its suitability for clinical use.

5.
Indian J Nucl Med ; 35(4): 310-314, 2020.
Article in English | MEDLINE | ID: mdl-33642755

ABSTRACT

AIM: Liver volume measurement is a mandatory test before measure liver surgeries and transplantation. We aimed a study on the difference in volume measurement and radiation dose to an anthropomorphic liver phantom using high-dose and low-dose diagnostic computed tomography (CT). MATERIALS AND METHODS: Several measurements of the manual total volume measurement done on an anthropomorphic liver phantom mounted with thermoluminescent dosimeter. We exposed the phantom with diagnostic CT, low-dose CT, and a low-dose CT with copper filter. RESULTS: Phantom underwent ten scanning for each exposure. There was no significant difference in the total volume measurement in comparison to the phantom volume. The volume of phantom measured by low-dose CT, low-dose CT with copper phantom, and high-dose CT were 1869 ± 18 cm3, 1852 ± 24 cm3, and 1908 ± 12 cm3, (P = 0.3), respectively. However, the radiation dose delivered was significantly different (1.54 mGy, 0.77 mGy, and 5.84 mGy [P = 0.001], respectively). CONCLUSION: Total liver volume measurement provides essential clinical information in several clinical conditions. We recommended that the volume measured by a low-dose CT has an excellent correlation with the diagnostic quality CT and should be a routine in the routine clinical practice. CT volumetry achieves the same result while using very less radiation exposure. It may also be used with functional imaging to give complete information.

6.
Indian J Nucl Med ; 35(4): 321-325, 2020.
Article in English | MEDLINE | ID: mdl-33642757

ABSTRACT

AIM: Radionuclide imaging and therapies produce radioactive liquid waste that may lead to significant radiation exposure to the general public. The study aims to assess the radiation exposure rate to public sewerage from a modified delay tank facility. We shall also evaluate the exposure rates and overall radioactivity at several points. MATERIALS AND METHODS: After having appropriate permission from the AERB, we measured the radiation exposure from the radionuclide therapy ward. Ward has three isolation beds and a single delay and decay tank of a capacity of 7500 liters. Effluents from the delay tank are processed at the filtration plant of the institute and subsequently released in the public sewerage. We obtained samples from several sites to determine discharged radioactivity. RESULTS: A total of 38 patients received 129.4 ± 42 mCi (Range 40- 200) radioiodine therapy during the study. Discharge of the tanks was done two times during the study. The radioactivity discharges into aeration plant were 89.2 and 71.2 mCi that correspond to 440.05 and 351 MBq/m3, respectively. This was diluted by the aeration tank (6 million liters). Finally, at the discharge time, the radioactivity in the discharge was 1.6 and 1.5 MBq/m3, respectively. The highest exposure rates were 14 µSv/h near the delay tank, which rapidly decreased on moving to the surrounding. CONCLUSION: Our study indicates that the addition of the dilution method and close monitoring may significantly reduce the radiation exposure and overall radioactivity release from the facility. Old facilities that do not have space to add up the tank capacity may get a benefit from it. A small change in the practice, such as admitting patients alternate months or providing extra decay time for radioactive waste, may lead to a cost-effective alternative.

7.
Indian J Nucl Med ; 34(3): 194-200, 2019.
Article in English | MEDLINE | ID: mdl-31293297

ABSTRACT

AIM: Gastric emptying (GE) scintigraphy is commonly used as a standard diagnostic procedure for the assessment of functional dyspepsia (FD). Results of the study are often reported as either normal or delayed GE times. The aim of this study was to recognize various patterns of scintigraphy among both normal and abnormal emptying times. MATERIALS AND METHODS: Fifty patients with suspected FD were included in the study. GE study was performed with a standardized vegetarian solid meal. RESULTS: Out of 50 patients, 33 patients had deranged GE. Thirty patients had delayed GE. Three patients demonstrated gastric hurrying. Five different patterns were demonstrated in patients having similar emptying and retention times such as reduced fundus compliance, decreased fundic accommodation, antral dysmotility, gastric hurrying, and gastroesophageal reflux. CONCLUSION: According to our findings, it may be suggested that visual assessment of GE and identification of various pattern is a very important aspect of the GE study. It not only subcategorized patients but also decreases the number of "normal" studies. This finding may have an impact on patient management in the era of personalized medicine.

8.
Bioorg Chem ; 82: 211-223, 2019 02.
Article in English | MEDLINE | ID: mdl-30326403

ABSTRACT

Based on the quantitative structure-activity relationship (QSAR), some novel p-aminobenzoic acid derivatives as promising cholinesterase enzyme inhibitors were designed, synthesized, characterized and evaluated to enhance learning and memory. The in vitro enzyme kinetic study of the synthesized compounds revealed the type of inhibition on the respective acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) enzymes. The in vivo studies of the synthesized compounds exhibited significant reversal of cognitive deficits in the animal models of amnesia as compared to standard drug donepezil. Further, the ex vivo studies in the specific brain regions like the hippocampus, hypothalamus, and prefrontal cortex regions also exhibited AChE inhibition comparable to standard donepezil. The in silico molecular docking and dynamics simulations studies of the most potent compound 22 revealed the consensual interactions at the active site pocket of the AChE.


Subject(s)
Alzheimer Disease/drug therapy , Cholinesterase Inhibitors/therapeutic use , Nootropic Agents/therapeutic use , para-Aminobenzoates/therapeutic use , Acetylcholinesterase/chemistry , Acetylcholinesterase/metabolism , Animals , Brain/metabolism , Butyrylcholinesterase/chemistry , Butyrylcholinesterase/metabolism , Catalytic Domain , Cholinesterase Inhibitors/chemical synthesis , Cholinesterase Inhibitors/chemistry , Cholinesterase Inhibitors/toxicity , Drug Design , Female , Kinetics , Male , Memory/drug effects , Molecular Docking Simulation , Molecular Dynamics Simulation , Molecular Structure , Nootropic Agents/chemical synthesis , Nootropic Agents/chemistry , Nootropic Agents/toxicity , Quantitative Structure-Activity Relationship , Rats , Semicarbazones/chemical synthesis , Semicarbazones/chemistry , Semicarbazones/therapeutic use , Semicarbazones/toxicity , para-Aminobenzoates/chemical synthesis , para-Aminobenzoates/chemistry , para-Aminobenzoates/toxicity
9.
Indian J Nucl Med ; 32(3): 233-234, 2017.
Article in English | MEDLINE | ID: mdl-28680213

ABSTRACT

Tc-99m labeled red blood cell (RBC) scintigraphy is one of the most sensitive tests to diagnose occult gastrointestinal (GI) bleed. Visualization of gallbladder is a rare finding in this study. Most of the previously reported cases with similar false-positive finding were associated chronic renal failure, anemia, and received multiple blood transfusions. Thus, while interpreting GI bleed scan, a thorough clinical history is of utmost importance to avoid any false-positive findings. Here, we report a case of gallbladder visualization in 99mTc-RBC scintigraphy confirmed by single-photon emission computed tomography/computed tomography in a patient with chronic renal failure and anemia with failed renal transplant within 3 months.

10.
J Nucl Med Technol ; 45(3): 241-242, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28408700

ABSTRACT

We present a case study in which artifacts from collimator contamination and patient motion were seen on a bone scan. Any identified artifact must be further investigated and documented so as to detect its source and thus prevent its future occurrence.


Subject(s)
Artifacts , Equipment Contamination/prevention & control , Equipment Failure Analysis/methods , Radiation Protection/methods , Radiopharmaceuticals/analysis , Technetium Tc 99m Medronate/analysis , Tomography, Emission-Computed, Single-Photon/instrumentation , Aged , Humans , Male
11.
Indian J Nucl Med ; 32(1): 25-29, 2017.
Article in English | MEDLINE | ID: mdl-28242980

ABSTRACT

The McCune-Albright syndrome (MAS) is a triad of café-au-lait skin pigmentation, precocious puberty (PP), and polyostotic fibrous dysplasia of bone (FD). In general, FD seems to be the most common component of MAS but very rarely precocious puberty can be found in association with café-au-lait skin pigmentation in the absence of FD (about 1% of the cases). Therefore, a more clinically relevant definition of MAS is fibrous dysplasia of bone (FD) and at least one of the typical hyperfunctioning endocrinopathy and/or café-au-lait spots, with almost any combination possible. Bone scan can be the modality of choice to look for bone disease burden of fibrous dysplasia in most patients of MAS and may change the management accordingly. Most of the cases of MAS reported worldwide are associated with hyperthyroidism, up to best of our knowledge on the basis of literature search in pubmed and Google; no case was reported with hypothyroidism. Herein, we report a 12-year-old girl diagnosed with MAS and associated hypothyroidism. We have also reviewed the MAS related literature.

12.
Indian J Nucl Med ; 31(4): 280-282, 2016.
Article in English | MEDLINE | ID: mdl-27833313

ABSTRACT

In nuclear medicine, 99mTc-methylene diphosphonate. (MDP) bone scan is one of the most commonly performed procedures. MDP uptake in nonosseous tissues is occasionally found in bone scan, and the knowledge of these kinds of extraosseous uptakes is of much clinical relevance. We report here two cases where bone scan showed extraosseous MDP uptake either hepatic or splenic apart from the physiological skeletal uptake.

13.
Indian J Nucl Med ; 31(2): 114-8, 2016.
Article in English | MEDLINE | ID: mdl-27095859

ABSTRACT

BACKGROUND: Measurement of accurate attenuation of photon flux in tissue is important to obtain reconstructed images using single-photon emission computed tomography (SPECT). Computed tomography (CT) scanner provides attenuation correction data for SPECT as well as anatomic information for diagnostic purposes. Segmentation is a process of dividing an image into regions having similar properties such as gray level, color, texture, brightness, and contrast. Image segmentation is an important tool for evaluation of medical images. X-ray beam used in CT scan is poly-energetic; therefore, we have used a copper filter to remove the low energy X-rays for obtaining correct attenuation factor. Images obtained with and without filters were quantitatively evaluated by segmentation method to avoid human error. MATERIALS AND METHODS: Axial images of AAPM CT phantom were acquired with 3 mm copper filter (low intensity) and without copper filter (high intensity) using low-dose CT (140 kvp and 2.5 mA) of SPECT/CT system (Hawkeye, GE Healthcare). For segmentation Simulated Annealing Based Fuzzy c-means, algorithm is applied. Quantitative measurement of quality is done based on universal image quality index. Further, for the validation of attenuation correction map of filtered CT images, Jaszczak SPECT phantom was filled with 500 MBq of (99m)Tc and SPECT study was acquired. Low dose CT images were acquired for attenuation correction to be used for reconstruction of SPECT images. Another set of CT images were acquired after applying additional 3 mm copper filter. Two sets of axial SPECT images were reconstructed using attenuation map from both the CT images obtained without and with a filter. RESULTS AND CONCLUSIONS: When we applied Simulated Annealing Based Fuzzy c-means segmentation on both the CT images, the CT images with filter shows remarkable improvement and all the six section of the spheres in the Jaszczak SPECT phantom were clearly visualized.

14.
Indian J Nucl Med ; 31(1): 27-30, 2016.
Article in English | MEDLINE | ID: mdl-26917890

ABSTRACT

INTRODUCTION: Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. MATERIALS AND METHODS: An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. RESULTS AND DISCUSSION: The radiation level at working distance while administering the radioactivity was found to be 106-170 µSv/h with a mean value of 126.5 ± 14.88 µSv/h which was reduced to 4.2-14.2 µSv/h with a mean value of 7.16 ± 2.29 µSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25-70 µSv/h with a mean value of 37.4 ± 13.16 µSv/h which was reduced to 1.0-5.0 µSv/h with a mean value of 2.77 ± 1.3 µSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. CONCLUSION: This study shows that good radiation practices are very helpful in reducing the personnel radiation doses. Use of radiation protection devices such as L-bench reduces exposure significantly. PET/CT staff members must use their personnel monitors diligently and should do so in a consistent manner so that comparisons of their doses are meaningful from one monitoring period to the next.

15.
World J Surg ; 40(7): 1583-9, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26324160

ABSTRACT

INTRODUCTION: Sentinel lymph node biopsy (SLNB) is the standard of care for staging N0 primary early breast cancers (EBC). Patients in developing countries mostly present with large (LOBC) or locally advanced cancers (LABC) and are treated with neo-adjuvant chemotherapy (NACT). Accuracy of SLNB in staging stage III N0 and post-NACT N0 patients is uncertain. This prospective validation study on LOBC/LABC patients compared the accuracy of SLNB between primary versus post-NACT surgery. MATERIALS AND METHODS: Fifty T3/T4, N0 patients undergoing primary surgery (Group I) and 70 LOBC/LABC (index stage) treated with NACT and N0 at the time of surgery (Group II) were inducted. Validation SLNB was performed using low-cost methylene-blue and (99m)Tc-Antimony colloid. SLN identification (IR) and false-negative (FNR) rates were compared between the groups. Sub-group analysis was done in Group II per index tumor and nodal stage to identify factors predicting SLN IR and FNR in post-NACT patients. SLN IR and FNR in both groups were compared with those in previously published SLN validation study and meta-analysis in EBC. RESULTS: Using combination of blue-dye and radio-colloid, post-NACT SLN IR and FNR (82.9, 13.5 %) were far inferior to T3/T4 primary surgery group (94, 7.7 %; p values 0.034, 0.041) and in EBC. SLN IR using blue-dye alone was dismally low in post-NACT LABCs. Factors predicting unidentified post-NACT SLN and false-negative SLNB included young age, LVI, skin infiltration, extra-nodal spread or N2a stage, and UOQ tumors. CONCLUSIONS: Accuracy of SLNB in T3, N0 tumors undergoing primary surgery is comparable to that of SLNB for N0 EBC. In post-NACT patients, SLNB IR are lower and FNR are higher. Factors predictive of non-identification and false-negative SLNB include pre-NACT skin involvement (T4b), N2a stage or extra-nodal invasion and LVI, and to a lesser extent, young age and UOQ location of the tumor.


Subject(s)
Breast Neoplasms/pathology , Sentinel Lymph Node Biopsy , Adult , Aged , Breast Neoplasms/diagnosis , Breast Neoplasms/therapy , Chemotherapy, Adjuvant , False Negative Reactions , Female , Humans , Middle Aged , Neoadjuvant Therapy , Neoplasm Staging , Prospective Studies
16.
Stem Cell Rev Rep ; 11(2): 309-21, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25433862

ABSTRACT

We investigated deleterious changes that take place in mesenchymal stem cells (MSC) and its fracture healing competence in ovariectomy (Ovx)-induced osteopenia. MSC from bone marrow (BM) of ovary intact (control) and Ovx rats was isolated. (99m)Tc-HMPAO (Technitium hexamethylpropylene amine oxime) labeled MSC was systemically transplanted to rats and fracture tropism assessed by SPECT/CT. PKH26 labeled MSC (PKH26-MSC) was bound in scaffold and applied to fracture site (drill-hole in femur metaphysis). Osteoinduction was quantified by calcein binding and microcomputed tomography. Estrogen receptor (ER) antagonist, fulvestrant was used to determine ER dependence of osteo-induction by MSC. BM-MSC number was strikingly reduced and doubling time increased in Ovx rats compared to control. SPECT/CT showed reduced localization of (99m)Tc-HMPAO labeled MSC to the fracture site, 3 h post-transplantation in Ovx rats as compared with controls. Post-transplantation, Ovx MSC labeled with PKH26 (Ovx PKH26-MSC) localized less to fracture site than control PKH26-MSC. Transplantation of either control or Ovx MSC enhanced calcein binding and bone volume at the callus of control rats over placebo group however Ovx MSC had lower efficacy than control MSC. Fulvestrant blocked osteoinduction by control MSC. When scaffold bound MSC was applied to fracture, osteoinduction by Ovx PKH26-MSC was less than control PKH26-MSC. In Ovx rats, control MSC/E2 treatment but not Ovx MSC showed osteoinduction. Regenerated bone was irregularly deposited in Ovx MSC group. In conclusion, Ovx is associated with diminished BM-MSC number and its growth, and Ovx MSC displays impaired engraftment to fracture and osteoinduction besides disordered bone regeneration.


Subject(s)
Bone Marrow/metabolism , Bone Regeneration , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/metabolism , Animals , Bone Diseases, Metabolic/metabolism , Bone Diseases, Metabolic/pathology , Female , Humans , Mesenchymal Stem Cells/pathology , Ovariectomy , Rats
17.
Ther Deliv ; 5(12): 1247-59, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25531927

ABSTRACT

BACKGROUND: The present study was designed to prepare and characterize poly lactide-co-glycolide nanoparticles of antitubercular drugs (ATDs) for delivery through oral route to alveolar macrophages. METHODS: Nanoparticles were prepared by double emulsification solvent evaporation method. Ex vivo and in vivo drug accumulation studies were performed in alveolar macrophages, harvested by broncheoalveolar lavaging. Internalization of nanoparticles was studied by confocal laser scanning microscopy. γ-scintigraphy imaging using technetium-99m was done to study the biodistribution pattern of nanoparticles. RESULTS: High intracellular concentrations of ATDs were observed in macrophages within 30 min of administration of nanoparticles. Intense radioactivity recorded in liver, spleen and lungs revealed uptake of nanoparticles in macrophages, abundantly present in mononuclear phagocyte system present in these organs. CONCLUSION: Targeted delivery of ATDs will help reduce dose and associated side effects including hepatotoxicity of ATDs. Further studies are required to assess the potential therapeutic advantages for treatment of TB.


Subject(s)
Antitubercular Agents/administration & dosage , Antitubercular Agents/pharmacokinetics , Drug Carriers/chemistry , Nanoparticles/chemistry , Polyglactin 910/chemistry , Administration, Oral , Animals , Chemistry, Pharmaceutical , Chromatography, High Pressure Liquid , Humans , Macrophages, Alveolar/metabolism , Male , Microscopy, Confocal , Particle Size , Radionuclide Imaging , Rats , Technology, Pharmaceutical , Tissue Distribution
18.
J Med Phys ; 37(1): 46-53, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22363112

ABSTRACT

Reconstruction of the tomographic images without attenuation correction can cause erroneously high count densities and reduced image contrast in low attenuation regions. In order to solve the problem of photon attenuation, one needs to know the attenuation coefficient for the individual patient being studied. Therefore, we made an attempt to correct the attenuation map in simultaneous transmission/emission tomography with (153)Gd/(67)Ga using maximum likelihood method using the expectation maximization (ML-EM) algorithm to correct the transmission window for both the spillover and downscatter. Spillover fraction, scatter fraction and parameters for the scatter function (A, b and c) were determined experimentally and optimized using the optimization program written in IDL based on simplex theory. All measurements were performed on a Vertex gamma camera using the anthropomorphic thorax phantom for validation of data obtained by the proposed method. It was observed that without spillover and downscatter correction, the mean counts were 19.29 in liver and 26.90 in lung, whereas after after applying the corrections, the mean counts were reduced to 3.80 and 15.10 in liver and lung, respectively, which were close to true mean counts (liver 2.15 and lung 14.89). In this proposed method, we introduced the set of F(t)(spillover) and K(t)(downscatter) to account for the variations in projection pixels (f(t) and k(t)) with the density and thickness. The F(t) and K(t) were determined using the transmission data by an iterative process. The quantitative error was reduced by 98.0% for lung and 90.0% for liver when the corrected transmission images were obtained after the subtraction of spillover and downscatter fraction.

19.
J Nucl Med Technol ; 40(1): 25-8, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22279237

ABSTRACT

UNLABELLED: Our purpose was to find out the cause of an unusual distinct break seen on a patient's sinogram despite within-tolerance results on all quality assurance tests during myocardial perfusion imaging (MPI) and corrective measures. METHODS: SPECT quality control is a prerequisite to obtaining high-quality diagnostic images. Daily uniformity and energy-peaking tests and weekly center-of-rotation (COR) tests are run to check the performance of the SPECT system. A distinct break in the sinogram of an MPI study was noticed for 1 patient, despite routine quality control tests that showed the system to be well within tolerance limits. Critical inspection of the γ-camera revealed that the 2 detector heads did not make complete contact with each other at a 90° position and that a gap of as much as 10.0 mm was left between the 2 edges of the detectors even though COR testing showed the system to be within tolerance limits. After this gap had been minimized (-10-mm position), the MPI study of this patient was repeated. RESULTS: Reduction of the gap between detectors corrected the sinogram discontinuity. On the MPI study, the break in the sinogram existed because the 2 detectors were not acquiring the data at the same position in their useful fields of view. When one of the detectors was tilted to exactly 45°, the gap was reduced and the data were acquired at the same useful field of view for both detectors. CONCLUSION: The sinogram artifact may arise even after perfect COR calibration, and in the reported case, the discontinuity in the sinogram was rectified by correcting the angle of the detectors. Meticulous investigation for artifacts must be performed to minimize the probability of false results.


Subject(s)
Artifacts , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon/methods , Humans , Movement , Myocardial Perfusion Imaging/standards , Quality Control
20.
Indian J Nucl Med ; 27(1): 10-5, 2012 Jan.
Article in English | MEDLINE | ID: mdl-23599591

ABSTRACT

PURPOSE: Lung perfusion scan provides a map of the spatial distribution of lung perfusion. This can be used to design radiation portals to spare functional lung (FL), potentially reducing lung toxicity. The purpose of this study was to assess the utility of lung perfusion single photon emission computed tomography (SPECT) in treatment planning for lung cancer patients. MATERIALS AND METHODS: Radiotherapy treatment planning computed tomography (CT) scans and SPECT scans of 11 patients of lung cancer suitable for external radiotherapy were co-registered. Conventional treatment plans (anatomic plan) and plans with FL information (functional plan) was generated. The difference in dose volume parameters (V20, V30 and mean lung doses) due to these two plans were compared using Bland-Altman plots. RESULTS: Functional plans produced a more favorable plan compared with anatomic plan in all except three cases. FL V20 values and FL mean lung dose were reduced for all patients by an average of 5.45 Gy and 7.72 Gy respectively which were statistically significant. CONCLUSIONS: Lung perfusion scans provide functional information which is not provided by CT scans. SPECT-guidance aids in reducing the dose delivered to highly perfused regions which could reduce the incidence of pneumonitis.

SELECTION OF CITATIONS
SEARCH DETAIL
...