Ann Acad Med Singap ; 32(4): 450-4, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12968548

ABSTRACT

INTRODUCTION: We compare the breath-hold fast recovery fast spin echo (BHFRFSE) T2-weighted and non-breath-hold fast spin echo (NBHFSE) T2-weighted sequences in image quality and lesion characterisation of focal liver lesions. MATERIALS AND METHODS: Fat-suppressed T2-weighted magnetic resonance (MR) images obtained with the 2 sequences (BHFRFSE and NBHFSE) in 79 patients with 113 liver lesions were analysed retrospectively. The image quality and nature of the lesions were evaluated by 2 experienced radiologists. RESULTS: Based on receiver operating characteristic curve analysis, lesion characterisation was comparable for both sequences. The image quality of BHFRFSE was significantly better than that of NBHFSE. The NBHFSE missed 4 malignant lesions while BHFRFSE missed 2 malignant lesions. CONCLUSION: BHFRFSE performs similarly to NBHFSE in image quality and liver lesion characterisation.


Subject(s)
Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Liver Neoplasms/diagnosis , Liver/pathology , Adult , Aged , Aged, 80 and over , Artifacts , Female , Humans , Liver Diseases/diagnosis , Male , Middle Aged , ROC Curve , Respiration , Risk Assessment , Sensitivity and Specificity , Statistics, Nonparametric