Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Publication year range
1.
Front Cardiovasc Med ; 11: 1342146, 2024.
Article in English | MEDLINE | ID: mdl-38464844

ABSTRACT

Missile embolization is rare in penetrating trauma, occurring in 0.3% of cases. Bullet embolism into the left ventricle is less frequent, with few instances described in the literature. This paper describes an instance of left ventricular bullet embolism from the pulmonary venous system following gunshot chest trauma. A 7-year-old boy sustained a gunshot wound to his chest during an assault accident. Despite thoracic pain, he remained conscious and exhibited vital signs. A CXR and CT scan revealed a bullet in the left mediastinum. A left thoracotomy was performed to remove blood and clots from the pericardium. The patient was sent to a tertiary referral hospital for further investigation. The patient underwent elective surgery to remove the foreign body from inside the heart. The procedure involved a partial thymectomy and pericardial opening, and the patient was released from medical care after 14 days. After 6 months, there were no signs or symptoms of cardiothoracic infection or evidence of mitral valve regurgitation in echocardiography.

2.
Cardiovasc Eng Technol ; 14(6): 786-800, 2023 12.
Article in English | MEDLINE | ID: mdl-37848737

ABSTRACT

PROPOSE: An electrocardiogram (ECG) has been extensively used to detect rhythm disturbances. We sought to determine the accuracy of different machine learning in distinguishing abnormal ECGs from normal ones in children who were examined using a resting 12-Lead ECG machine, and we also compared the manual and automated measurement using the modular ECG Analysis System (MEANS) algorithm of ECG features. METHODS: Altogether, 10745 ECGs were recorded for students aged 6 to 18. Manual and automatic ECG features were extracted for each participant. Features were normalized using Z-score normalization and went through the student's t-test and chi-squared test to measure their relevance. We applied the Boruta algorithm for feature selection and then implemented eight classifier algorithms. The dataset was split into training (80%) and test (20%) partitions. The performance of the classifiers was evaluated on the test data (unseen data) by 1000 bootstrap, and sensitivity (SEN), specificity (SPE), AUC, and accuracy (ACC) were reported. RESULTS: In univariate analysis, the highest performance was heart rate and RR interval in the manual dataset and heart rate in an automated dataset with AUC of 0.72 and 0.71, respectively. The best classifiers in the manual dataset were random forest (RF) and quadratic-discriminant-analysis (QDA) with AUC, ACC, SEN, and SPE equal to 0.93, 0.98, 0.69, 0.99, and 0.90, 0.95, 0.75, 0.96, respectively. In the automated dataset, QDA (AUC: 0.89, ACC:0.92, SEN:0.71, SPE:0.93) and stack learning (SL) (AUC:0.89, ACC:0.96, SEN:0.61, SPE:0.99) reached best performances. CONCLUSION: This study demonstrated that the manual measurement of 12-Lead ECG features had better performance than the automated measurement (MEANS algorithm), but some classifiers had promising results in discriminating between normal and abnormal cases. Further studies can help us evaluate the applicability and efficacy of machine-learning approaches for distinguishing abnormal ECGs in community-based investigations in both adults and children.


Subject(s)
Algorithms , Machine Learning , Adult , Child , Humans , Adolescent , Cohort Studies , Arrhythmias, Cardiac/diagnosis , Electrocardiography/methods
3.
Pacing Clin Electrophysiol ; 46(4): 273-278, 2023 04.
Article in English | MEDLINE | ID: mdl-36751953

ABSTRACT

BACKGROUND: The subcutaneous implantable-defibrillator (S-ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead-related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S-ICD registry. METHODS: Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post-implant complications and long-term follow-up results of the S-ICD system. RESULTS: The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S-ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow-up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure. CONCLUSION: S-ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.


Subject(s)
Defibrillators, Implantable , Humans , Male , Female , Adult , Middle Aged , Prospective Studies , Iran , Treatment Outcome , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Registries
4.
Ann Noninvasive Electrocardiol ; 28(2): e13047, 2023 03.
Article in English | MEDLINE | ID: mdl-36683354

ABSTRACT

BACKGROUND AND AIM: Prolonging the QT interval in the right bundle branch block (RBBB) can create challenges for electrophysiologists in estimating repolarization time and eliminating the effect of depolarization changes on QT interval. In this study, we aimed to develop a practice formula to eliminate the effect of depolarization changes on QT interval in patients with RBBB. METHODS: This prospective study evaluated accidentally induced RBBB in patients undergoing electrophysiological study. Two expert electrophysiologists recorded the ECG parameters, including QRS duration, QT interval, and cycle length, in the patients. The formula was developed based on QT interval differences (with and without RBBB) and its proportion to QRS. Additionally, the Bazzet, Rautaharju, and Hodge formulas were used to evaluate QTc. RESULTS: We evaluated 96 patients in this study. The mean QT interval without RBBB was 369.39 ± 37.38, reaching 404.22 ± 39.23 after inducing RBBB. ΔQT was calculated as 34.83 ± 17.61, and the ratio of ΔQT/QRS with RBBB was almost 23%. Our formula is: (QTwith RBBB  - 23% × QRS). Subtraction of 25% instead of 23% seems more straightforward and practical. Our formula could also predict the QTc interval in RBBB based on the Bazzet, Rautaharju, and Hodge formulas. CONCLUSION: Previous formulas for QT correction were hard to apply in the clinical setting or were not specified for RBBB. Our new formula allows a rapid and practical method for QT correction in RBBB in clinical practice.


Subject(s)
Bundle-Branch Block , Electrocardiography , Humans , Bundle-Branch Block/diagnosis , Prospective Studies , Electrocardiography/methods
5.
Rev Port Cardiol ; 41(1): 43-47, 2022 Jan.
Article in English, Portuguese | MEDLINE | ID: mdl-36062680

ABSTRACT

INTRODUCTION AND OBJECTIVES: Pregnancy can affect the cardiac conduction system, causing changes to the electrocardiographic indices that may mimic pathologic ones. The aim of this study was to discover these changes in normal pregnant women. METHODS: We included 103 healthy pregnant women, aged between 18-35 years. Standard 12-lead electrocardiogram was performed in the first and third trimester and electrocardiographic indices were calculated. The patients were classified in two age categories. RESULTS: The mean PR interval in trimester one (T1) was 133.36±20.9 ms and in third trimester (T3) was 125.03±22.6ms (p=0.046). The mean QT in T1 and T3 was 314.21±18.99 ms and 324.02±19.4 ms, respectively (p<0.001). QRS duration in T1 and T3 was 90.24±28.91 ms and 94.97±10.79 ms, respectively (p=0.027). Mean of QTc (corrected QT interval) was 384.03±23.2 in T1 and 393.20±42.48 ms in T3 (p 0.023). The difference in electrocardiogram indices between T1 and T3 was not significant within the two age groups. CONCLUSION: When comparing results between T1 and T3, mean parameters of electrocardiogram indices showed significant statistical differences. This will contribute insight on the approach to a number of pregnant women who complain of palpitations and visit a cardiologist. Although not statistically significant, the QT dispersion was 2% higher in participants over 30 years of age.

6.
J Cardiovasc Thorac Res ; 13(2): 156-161, 2021.
Article in English | MEDLINE | ID: mdl-34326970

ABSTRACT

Introduction: Pulmonary stenosis with an intact ventricular septum (PS-IVS) is one of the common causes of cyanotic heart disease in neonates with diverse morphologies as well as management and treatment protocols. The aim of this study was to evaluate short and midterm results of balloon pulmonary valvuloplasty (BPV) for this disorder. Methods: Between 2012 and 2016, Totally 45 neonates and infants under 6 months old were evaluated.The patients had a minimum right-to-left ventricular pressure ratio of 1, right-to-left shunting at the patent foramen ovale or atrial septal defect level, and tricuspid valve Z-scores higher than -4. Results: Immediately after the procedure, the right ventricular pressure dropped to the normal values in 8 (20%) patients. The immediate procedural success rate was seen in 42 (93.3%) cases: the right-to-left ventricular pressure ratio dropped to below 50% or the level of O2 saturation rose above 75%. Of three cases unresponsive to BPV, two of them underwent patent ductus arteriosus (PDA) stenting and one procedural death occurred. At 6 months' follow-up, of 42 patients, this pressure was still with in the normal range in 36 (80%) infants, while it had returned to high values in 9 (20%) patients and necessitated repeat valvuloplasty. After BPV, severe pulmonary valve regurgitation was observed in14.2% patients; the condition was more common when high-profile noncompliant balloons were used. Conclusion: Balloon pulmonary valvuloplasty in infants with PS-IVS confers acceptable results insofar as it improves echocardiographic parameters and hemodynamic changes at short- and midterm followups.Balloon selection with sizes more than 1.2 of the diameter of the pulmonary valve annulus and the use of noncompliant high-pressure balloons results in higher degrees of pulmonary regurgitation.

7.
Curr Cardiol Rev ; 16(2): 103-116, 2020.
Article in English | MEDLINE | ID: mdl-31593532

ABSTRACT

The association between thyroid disease and cardiovascular manifestations is significant and undeniable. Previous studies have explained several aspects of the effects of thyroid hormone on the heart and cardiovascular system. Accordingly, both hyper and hypothyroidism can cause important alterations in cardiac rhythm, output and contractility as well as vascular resistance and blood pressure. Since treating the thyroid abnormality, especially in its initial stages, could lead to a significant improvement in most of its resultant cardiovascular disturbances, early suspicion and recognition of thyroid dysfunction, is necessary in patients with cardiovascular manifestations. In this in-depth review, we discuss the physiological roles as well as the effects of abnormal levels of thyroid hormones on the cardiovascular system. We also review the effects of the medications used for the treatment of hyper and hypothyroidism on cardiac function. In the end, we discuss the association between thyroid function and amiodarone, an effective and frequently-used antiarrhythmic drug, because of its well-known effects on the thyroid.


Subject(s)
Cardiovascular Diseases/drug therapy , Thyroid Diseases/drug therapy , Cardiovascular Diseases/physiopathology , Cardiovascular System/physiopathology , Humans
8.
Case Rep Cardiol ; 2017: 1528416, 2017.
Article in English | MEDLINE | ID: mdl-28634553

ABSTRACT

Acute lymphoblastic leukemia (ALL) is a systemic disease that is presented with different symptoms and signs. Cardiac manifestation is rare in ALL, but it is very important and needs appropriate management. It usually presents as leukemic myocardial infiltration and in the presence of cardiac mass comprehensive evaluation for other etiologies is mandatory. We reported on a 6-year-old boy in remission phase of ALL and large cardiac mass in the right atrium with obscure early symptoms and signs, in whom infective endocarditis (IE) was diagnosed and appropriate medical treatment was performed. Because the mass was sustained, surgical resection was considered for the patient.

SELECTION OF CITATIONS
SEARCH DETAIL
...