1.
Micromachines (Basel) ; 14(5)2023 Apr 30.
Article in English | MEDLINE | ID: mdl-37241614

ABSTRACT

To form a diffraction-free beam with a complex structure, we propose to use a set of primitives calculated iteratively for the ring spatial spectrum. We also optimized the complex transmission function of the diffractive optical elements (DOEs), which form some primitive diffraction-free distributions (for example, a square or/and a triangle). The superposition of such DOEs supplemented with deflecting phases (a multi-order optical element) provides to generate a diffraction-free beam with a more complex transverse intensity distribution corresponding to the composition of these primitives. The proposed approach has two advantages. The first is the rapid (for the first few iterations) achievements of an acceptable error in the calculation of an optical element that forms a primitive distribution compared to a complex one. The second advantage is the convenience of reconfiguration. Since a complex distribution is assembled from primitive parts, it can be reconfigured quickly or dynamically by using a spatial light modulator (SLM) by moving and rotating these components. Numerical results were confirmed experimentally.

2.
Vision (Basel) ; 7(1)2023 Mar 12.
Article in English | MEDLINE | ID: mdl-36977301

ABSTRACT

Various diffractive, refractive and holographic optical elements, such as diffraction gratings; microlens raster; phase plates; multi-order diffractive optical elements; adaptive mirrors; diffractive and refractive axicons; holographic multiplexes and many others are used to analyze wavefront aberrations. We shortly discuss the features (advantages and disadvantages) of various wavefront aberration sensors in the Introduction. The main part of the paper is devoted to the analysis of the weight coefficients of Zernike polynomials obtained during medical examinations of the cornea in the human eye. Using data obtained by aberrometers, the average values of the Zernike polynomial coefficients for the anterior and posterior surfaces of the healthy eye cornea and a myopic one were calculated. The original wavefront for the anterior and posterior surfaces of the cornea was restored separately, as well as the total wave aberration. For an objective assessment of the quality of vision, the corresponding point spread functions (PSFs) were calculated. We propose to compensate for the aberrations of the myopic eye, taking into account the physical features of the corneal surface. The results of numerical simulation showed that in order to improve the quality of the patient's vision, it is necessary to take into account high-order aberrations of the anterior surface of the cornea in the form of a coma of the third order and aberrations of the fourth order.

3.
Sensors (Basel) ; 22(19)2022 Sep 28.
Article in English | MEDLINE | ID: mdl-36236463

ABSTRACT

It is known that the astigmatic transformation can be used to analyze the topological charge of a vortex beam, which can be implemented by using various optical methods. In this case, in order to form an astigmatic beam pattern suitable for the clear detection of a topological charge, an optical adjustment is often required (changing the lens tilt and/or the detection distance). In this article, we propose to use multi-channel diffractive optical elements (DOEs) for the simultaneous implementation of the astigmatic transformations of various types and levels. Such multi-channel DOEs make it possible to insert several types of astigmatic aberrations of different levels into the analyzed vortex beam simultaneously, and to form a set of aberration-transformed beam patterns in different diffraction orders in one detection plane. The proposed approach greatly simplifies the analysis of the characteristics of a vortex beam based on measurements in the single plane without additional adjustments. In this article, a detailed study of the effect of various types of astigmatic aberrations based on a numerical simulation and experiments was carried out, which confirmed the effectiveness of the proposed approach.

4.
Sensors (Basel) ; 21(19)2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34641014

ABSTRACT

Axicon is a versatile optical element for forming a zero-order Bessel beam, including high-power laser radiation schemes. Nevertheless, it has drawbacks such as the produced beam's parameters being dependent on a particular element, the output beam's intensity distribution being dependent on the quality of element manufacturing, and uneven axial intensity distribution. To address these issues, extensive research has been undertaken to develop nondiffracting beams using a variety of advanced techniques. We looked at four different and special approaches for creating nondiffracting beams in this article. Diffractive axicons, meta-axicons-flat optics, spatial light modulators, and photonic integrated circuit-based axicons are among these approaches. Lately, there has been noteworthy curiosity in reducing the thickness and weight of axicons by exploiting diffraction. Meta-axicons, which are ultrathin flat optical elements made up of metasurfaces built up of arrays of subwavelength optical antennas, are one way to address such needs. In addition, when compared to their traditional refractive and diffractive equivalents, meta-axicons have a number of distinguishing advantages, including aberration correction, active tunability, and semi-transparency. This paper is not intended to be a critique of any method. We have outlined the most recent advancements in this field and let readers determine which approach best meets their needs based on the ease of fabrication and utilization. Moreover, one section is devoted to applications of axicons utilized as sensors of optical properties of devices and elements as well as singular beams states and wavefront features.