Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Acad Emerg Med ; 11(1): e49, 2023.
Article in English | MEDLINE | ID: mdl-37609534

ABSTRACT

Introduction: Differentiating the soft tissue abscess from other types of skin and soft tissue infections (SSTIs) poses a particular challenge because they have similar physical evaluation findings, but each disease has a different course, outcome, and treatment. This meta-analysis aimed to investigate the diagnostic accuracy of point-of-care ultrasonography for diagnosis of soft tissue abscess in the emergency departments. Methods: A comprehensive literature search of MEDLINE, Scopus, Web of Science, Embase, and Google Scholar, from inception to January 2023, was conducted to identify relevant studies investigating the diagnostic performance of point-of-care ultrasonography for identification of abscess. Methodological quality of the included studies was assessed using a revised tool for the quality assessment of diagnostic accuracy studies (QUADAS-2). Results: The pooled estimates of diagnostic parameters of ultrasonography for diagnosis of abscess were as follows: sensitivity, 0.93 (95% CI: 0.92-0.94); specificity, 0.87 (95% CI: 0.85-0.89), and the area under the summary receiver-operating characteristic (SROC), 0.95. The pooled sensitivity, specificity, and area under the SROC of studies in adult patients were 0.98 (95% CI: 0.92-1), 0.92 (95% CI: 0.86-0.95), and 0.99, respectively. The pooled sensitivity, specificity, and area under the SROC of studies in pediatric patients were 0.9 (95% CI: 0.87-0.92), 0.78 (95% CI: 0.73-0.82), and 0.91, respectively. Conclusion: Our meta-analysis demonstrated that the point-of-care ultrasonography has excellent diagnostic value for the abscess in the emergency department. Furthermore, we found that the diagnostic performance of point-of-care ultrasonography for diagnosis of abscess was higher for adult cases than for pediatric patients.

2.
Arch Acad Emerg Med ; 11(1): e24, 2023.
Article in English | MEDLINE | ID: mdl-36919137

ABSTRACT

Introduction: The diagnosis of intussusception can be challenging in children due to the fact that the findings of clinical evaluations are nonspecific and most of the patients present with unclear history. Therefore, in this systematic review and meta-analysis, we aimed to investigate the diagnostic accuracy of ultrasonography for detection of intussusception and also compare the efficacy of point-of-care ultrasound (POCUS) with radiologist-performed ultrasound (RADUS). Methods: Two independent reviewers systematically searched different online electronic databases including MEDLINE, Scopus, Web of Science, Google Scholar, Embase, and Cochrane from inception to December 1, 2022 to identify published papers reporting accuracy of ultrasonography for diagnosis of intussusception. The quality assessment of the included studies was investigated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Results: A total of 1446 records were retrieved in the initial search of databases. After screening the titles, a total of 344 studies were retrieved for the detailed assessment of full-text. Finally, 37 studies were included in qualitative and quantitative analysis. The pooled sensitivity and specificity of ultrasonography for diagnosis of intussusception were 0.96 (95% CI: 0.95-0.97) and 0.97 (95% CI: 0.97-0.98), respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 24.57 (95% CI: 8.26-73.03) and 0.05 (95% CI: 0.04-0.08), respectively. The area under the hierarchical summary receiver operating characteristic (HSROC) curve was 0.989. Mete-regression showed that there is no significant difference between diagnostic performance of POCUS and RADUS (p = 0.06 and rDOR (diagnostic odds ratio) = 4.38 (95% CI: 0.92-20.89)). Conclusion: This meta-analysis shows that ultrasonography has excellent sensitivity, specificity, and accuracy for diagnosis of intussusception in pediatric patients. Moreover, we found that diagnostic performance of POCUS is similar to that of RADUS for diagnosis of intussusception.

3.
Perfusion ; 38(6): 1123-1132, 2023 09.
Article in English | MEDLINE | ID: mdl-35724310

ABSTRACT

BACKGROUND: Acute submassive a massive pulmonary embolism are known as leading causes of cardiovascular morbidity and mortality in emergency departments. Choosing the optimal type of catheter directed thrombolysis (CDT) for treatment of pulmonary embolism presents a quandary to the practitioners. To the best of our knowledge, there is no meta-analysis comparing superiority of conventional CDT and ultrasound-accelerated catheter directed thrombolysis (USACDT). Therefore, in this meta-analysis, we aimed to compare conventional CDT with USACDT regarding clinical outcomes and safety profile. METHODS: A systematic literature search of previous published studies comparing conventional CDT with USACDT regarding clinical outcomes and safety profile was carried out in the electronic databases including MEDLINE, Scopus, EBSCO, Google Scholar, Web of Science, and Cochrane from inception to December 2021. Data were analyzed by comprehensive meta-analysis software (CMA, version 3). RESULTS: The meta-analysis included nine studies with a total of 705 patients. Our meta-analysis showed that there is no significant difference between two groups with respect to pulmonary arterial systolic pressure (SMD: -0.084; 95% CI: -0.287 to 0.12; p: 0.41), RV/LV (SMD: -0.003; 95% CI: -0.277 to 0.270; p: 0.98), and Miller score (SMD: -0.345; 95% CI: -1.376 to 0.686; p: 0.51). Similarly, we found no statistically significant differences between two groups regarding major and minor bleeding (p > .05). CONCLUSION: Our meta-analysis showed that when compared with USACDT, conventional CDT provides similar clinical and hemodynamic outcomes or safety for treatment of pulmonary embolism without the need for very expensive technologies. However, randomized clinical trials are required to further investigate cost-effectiveness of USACDT in comparison with conventional CDT.


Subject(s)
Fibrinolytic Agents , Pulmonary Embolism , Humans , Fibrinolytic Agents/therapeutic use , Thrombolytic Therapy/adverse effects , Thrombolytic Therapy/methods , Treatment Outcome , Pulmonary Embolism/drug therapy , Catheters , Retrospective Studies
4.
Arch Acad Emerg Med ; 9(1): e68, 2021.
Article in English | MEDLINE | ID: mdl-34870234

ABSTRACT

INTRODUCTION: Recent studies have suggested that point-of-care ultrasonography can be used for confirming the placement of endotracheal tube. This systematic review and meta-analysis aimed to investigate the sensitivity and specificity of ultrasonography for confirming endotracheal tube placement. METHODS: In this meta-analysis, systematic search of the previous published papers investigating the diagnostic accuracy of ultrasonography for confirmation of endotracheal tube placement was performed. Seven electronic databases, including PubMed, Scopus, Google Scholar, EBSCO, EMBASE, Web of Science, and Cochrane Database were searched up to July 2021, for all relevant articles published in English on this topic. Meta-DiSc version 1.4 software was used for statistical analysis. RESULTS: The estimated pooled sensitivity and specificity of ultrasonography for confirmation of endotracheal tube location were 0.98 (95% CI: 0.98-0.99) and 0.94 (95% CI 0.91-0.96), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 5.94 (95% CI 4.41-7.98) and 0.03 (95% CI: 0.02-0.04), respectively. The diagnostic odds ratio of ultrasonography was 281.47 and the area under hierarchical summary receiver operating characteristic (HSROC) revealed an appropriate accuracy of 0.98. CONCLUSION: Ultrasonography has high diagnostic accuracy and can be used as a promising tool for confirmation of endotracheal tube placement, especially in critically ill patients or when capnography is not available, or its result is equivocal.

SELECTION OF CITATIONS
SEARCH DETAIL
...