Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Radiol Med ; 125(8): 706-714, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32206985

ABSTRACT

AIM: To examine the clinical and histopathological consequences of MRI in sheep implanted with non-MRI-conditional cardiac pacemakers. MATERIALS AND METHODS: Under general anesthesia, active fixation leads of two dual-chamber, non-MRI-conditional cardiac pacemakers (St. Jude Medical and Medtronic) were implanted either at the right ventricular apex or at the right atrium of two male sheep and connected to the V and A channels of the pacemakers, respectively. The generators were placed in cervical subcutaneous pockets. On day 5, both sheep underwent 1.5 T cervical and chest MRI with continuous electrocardiogram monitoring. Obtained sequences were T1-weighted (T1W), T2-weighted (T2W), T2-gradient echo and diffusion weighted (DW). The employed modes were OVO, VOO and VVI for one sheep and OAO, AOO and AAI for the other (unipolar and bipolar configuration of pacing and sensing for both). Battery impedance, pacing lead impedance, intrinsic amplitude and capture thresholds were checked at baseline and after each sequence, as well as 48 h after imaging. Histopathological examination of the cardiac tissue around the lead tip was performed 4 weeks post-imaging. RESULTS: No significant changes in device position or configuration were observed during or after MRI. Clinical outcome was uneventful in both sheep. Minor inflammatory and necrotic changes were reported after histopathological examination of the cardiac tissue around the lead tip. CONCLUSION: 1.5 T MRI of two implanted non-MRI-conditional pacemakers was found safe in terms of device configuration and stability, clinical outcome and cardiac tissue histopathological findings.


Subject(s)
Equipment Safety , Magnetic Resonance Imaging/methods , Pacemaker, Artificial , Prosthesis Implantation/methods , Animals , Cardiac-Gated Imaging Techniques , Diffusion Magnetic Resonance Imaging , Male , Necrosis , Prosthesis Implantation/adverse effects , Sheep
2.
Br J Radiol ; 89(1066): 20150152, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27452260

ABSTRACT

OBJECTIVE: To examine the effect of using different b-values on the utility of diffusion-weighted (DW) MRI in differentiating acute infectious spondylitis from Modic type 1 and the discriminative accuracy of related apparent diffusion coefficient (ADC), claw-sign and amorphous increased signal. METHODS: 43 patients with equivocal diagnosis of acute infectious spondylitis/Modic type 1 by using MR images were prospectively studied. The discriminative accuracy of DW MRI using three b-values of 50, 400, 800 s mm(-2), ADC, claw sign and amorphous increased signal was examined. RESULTS: DW MRI differentiated infectious spondylitis from Modic type 1 change most accurately when a b-value of 800 s mm(-2) was chosen [sensitivity, 91.7%; specificity, 96.8%; positive-predictive value (PPV), 91.7%; negative-predictive value (NPV), 96.8%; and accuracy, 95.3%]. The optimal cut-off ADC value was 1.52 × 10(-3) mm(2) s(-1) (sensitivity, 91.7%; specificity, 100%; PPV, 100%; NPV, 96.9%; and accuracy, 97.7%). Best visualized at a b-value of 50 s mm(-2), claw sign (for degeneration) and amorphous increased signal (for infection) were 100% accurate. CONCLUSION: Should DW MRI be used in differentiating acute infectious spondylitis from degeneration, large b-values are required. With low b-values, however, claw sign and amorphous increased signal are very accurate in this regard. ADVANCES IN KNOWLEDGE: DW MRI using large b-values could be used in differentiating acute infectious spondylitis from Modic type I.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Spondylitis/diagnostic imaging , Spondylitis/pathology , Adult , Aged , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted , Image-Guided Biopsy , Male , Middle Aged , Prospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...