Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Infect Chemother ; 29(2): 219-222, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36346265

ABSTRACT

Schizophyllum commune is a widely distributed basidiomycete fungus that occasionally causes sinusitis or allergic bronchopulmonary mycosis. The invasive infection mostly occurs in immunocompromised adults. The number of reports on S. commune infection have increased in this decade due to the expansion of diagnostic techniques and awareness in clinical practice. However, S.commune infection in patients with primary immunodeficiencies has not been reported yet. Here, we described S. commune-abscesses developed in the brain and lung of a boy with chronic granulomatous disease (CGD) after allogenic hematopoietic cell transplantation (HCT). A 12-year-old CGD patient developed febrile neutropenia from day 4 after HCT, followed by chest pain on day 23. He had no obvious infection before HCT. Diagnostic imaging revealed disseminated lung and brain abscesses. He received administration of voriconazole, and his symptoms improved after engraftment. Chronic administration of voriconazole had also a favorable therapeutic response to brain lesion. A part of the fungus ball exhaled by the patient was cultured to develop a filamentous fungus. S. commune was identified by the analysis of the 28S rRNA gene. The catalase test was positive for S. commune, indicating that S. commune had virulence in this patient with CGD. The assessment of specific-IgG to S. commune suggested peri-transplant infection, although colonization was not excluded. This rare pediatric case of S. commune infection highlights that CGD patients are vulnerable to invasive infection, especially when undergoing HCT.


Subject(s)
Granulomatous Disease, Chronic , Invasive Pulmonary Aspergillosis , Schizophyllum , Child , Humans , Male , Abscess , Granulomatous Disease, Chronic/complications , Granulomatous Disease, Chronic/drug therapy , Invasive Pulmonary Aspergillosis/diagnosis , Schizophyllum/genetics , Voriconazole/therapeutic use
2.
J Infect Chemother ; 29(1): 82-86, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36162647

ABSTRACT

An 81-year-old man was admitted to our hospital because of fever and malaise that had persisted for 3 months. The patient had undergone two aortic valve replacements, 10 and 5 years previously, because of aortic valve regurgitation and infectious endocarditis. He also had had asymptomatic Mycobacterium abscessus complex (MABC) pulmonary disease for the two previous years. Contrast-enhanced computed tomography showed a mediastinal abscess and an ascending aortic aneurysm. Mycobacterium abscessus subsp. massiliense was cultured from his blood, suggesting the aortic aneurysm was secondary to infection of an implanted device. After enlargement over only a few days, a leakage of contrast medium to the mediastinal abscess was found on computed tomography. The patient was diagnosed with rupture of an infectious aortic aneurysm, and emergency aortic replacement and drainage of the mediastinal abscess were successful. The patient was treated with several antibiotics, including meropenem, amikacin, and clarithromycin, and his general condition improved. Cultures from both the mediastinal abscess and a pericardial patch that was placed at the time of surgery 5 years previously revealed MABC. In our case, the infected aortic aneurysm most likely resulted from MABC pulmonary disease rather than from previous intraoperative contamination. This route of infection is rare. Physicians should be aware of the possibility of dissemination and subsequent infection of implants related to MABC pulmonary disease.


Subject(s)
Aortic Aneurysm , Lung Diseases , Mycobacterium Infections, Nontuberculous , Mycobacterium abscessus , Male , Humans , Aged, 80 and over , Mycobacterium Infections, Nontuberculous/diagnosis , Mycobacterium Infections, Nontuberculous/drug therapy , Mycobacterium Infections, Nontuberculous/microbiology , Abscess , Clarithromycin/therapeutic use , Anti-Bacterial Agents/therapeutic use , Lung Diseases/microbiology , Microbial Sensitivity Tests
4.
Diagn Microbiol Infect Dis ; 83(3): 232-3, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26298818

ABSTRACT

In our hospital, positive blood culture rates of Helicobacter cinaedi dramatically increased after introducing the Bactec system. A simulated culture model of H. cinaedi bacteremia demonstrated no positive signals using the BacT/Alert system, despite efficient growth in bottles. Clinically suspected H. cinaedi bacteremia should be monitored more closely when using the BacT/Alert system, preferably with subcultivation after 7days of incubation.


Subject(s)
Bacteremia/diagnosis , Bacteriological Techniques/methods , Blood/microbiology , Helicobacter Infections/diagnosis , Helicobacter/isolation & purification , Bacteremia/microbiology , Helicobacter Infections/microbiology , Humans , Sensitivity and Specificity
5.
J Med Microbiol ; 64(10): 1144-1150, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26296999

ABSTRACT

Microflex LT (Bruker Daltonics) and VITEK MS (bioMérieux) are bacterial identification systems that are based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). For VITEK MS, two identification softwares, VITEK MS IVD (IVD) and SARAMIS (SARAMIS), are available. Microflex LT is equipped with MALDI Biotyper RTC software (Biotyper). Although the identification accuracy of each instrument has been compared for various bacteria, no detailed examination has been conducted for the identification accuracy of Clostridium difficile. In this report, we compared the three identification softwares for identification reproducibility in three ATCC C. difficile strains and identification accuracy in 50 clinical C. difficile isolates. The results showed 100, 91.7 and 100 % identification reproducibility accuracy of ATCC strains when examined by IVD, SARAMIS and Biotyper software, respectively. For the identification of the clinical isolates, all three softwares exhibited satisfactory identification accuracy of C. difficile. Among the 50 clinical isolates, seven showed identical toxin genotype corresponding to the exact ribotype. However, MALDI-TOF MS failed to identify them as the identical type. Based on the above results, we concluded that both types of MALDI-TOF MS reproducibly identified C. difficile; however, they are currently not suitable for typing of C. difficile clones.


Subject(s)
Bacteriological Techniques/methods , Clostridioides difficile/classification , Clostridioides difficile/isolation & purification , Clostridium Infections/diagnosis , Software , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Clostridioides difficile/chemistry , Clostridium Infections/microbiology , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...