1.
J Clin Med ; 12(15)2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37568458

ABSTRACT

BACKGROUND: An adequate interlesion distance (ILD) applied during point-by-point pulmonary vein (PV) isolation for atrial fibrillation (AF) has never been established. We hypothesized that maximum tolerated ILD may differ between PV regions and may influence long-term ablation outcomes. METHODS: A total of 260 AF patients underwent PV isolation with 3D electroanatomical platform. Postablation, ILD values were classified into 5 groups (6-5.5 mm, 5.5-5.0 mm, 5.0-4.5 mm, 4.5-4.0 mm and <4.0 mm); the number of tags in each group was calculated and correlated with postablation AF recurrence (AFR). All measurements were performed globally for the entire encirclement around each individual PV and regionally for designated PV anatomic segments. RESULTS: Single-procedure freedom from AF was 81% for paroxysmal and 66% for persistent AF at 12 months. Global analysis showed that AFR was not related to median ILD nor the number of lesions within each ILD tag group for any PV. Segmental analysis showed that AFR was not related to median ILD. However, the presence of tags from the 5.5-6.0 mm ILD group located on the posterior aspect of right upper PV (RUPV) correlated with AFR. This was confirmed in a multivariable logistic regression model. CONCLUSIONS: Maximum tolerated ILD of 6.0 mm translated into well-accepted ablation results. However, the study suggests that it may be inadequate at the posterior aspect of RUPV.

2.
J Cardiovasc Dev Dis ; 9(5)2022 May 02.
Article in English | MEDLINE | ID: mdl-35621853

ABSTRACT

Background: The incidence and influence of vagal response (VR) observed during cryoballoon-based pulmonary vein isolation (CBA-based PVI) on the cardiac autonomic nervous system (CANS) and ablation outcomes in paroxysmal atrial fibrillation (PAF) remain unknown. Methods: 296 patients were treated with a 28 mm second-generation cryoballoon (Medtronic). A total of 74 patients without structural heart disease and concomitant diseases were chosen for a detailed CANS assessment with a heart rate variability (HRV) analysis. All patients were screened over a 2-year post-ablation period. Results: VR was detected in 30% of patients and included sinus arrest (64%) or severe sinus bradycardia (46%). The presence of VR was not related to PV ostial dimension, patient clinical characteristics or intraprocedural ablation details. CANS modulation, manifesting as increased median HR and decreased HRV parameters with intact sympatho-vagal balance occurred independently of VR presence or absence and sustained for at least 12 months following ablation. VR was not related with more intensive CANS modulation and did not translate into better ablation outcomes when compared to the non-VR group (74% vs. 71% at 12 months and 69% vs. 65% at 24 months respectively). Conclusions: VR is frequent during CBA-based PVI for PAF and unrelated to any additional clinical benefit.

3.
Cardiol J ; 29(4): 660-669, 2022.
Article in English | MEDLINE | ID: mdl-32419127

ABSTRACT

BACKGROUND: Left atrial (LA) arrhythmogenic substrate beyond the pulmonary veins (PV) seems to play a crucial role in the maintenance of atrial fibrillation (AF). The aim of this study was to evaluate the association of selected parameters with the presence and extent of voltage-defined LA fibrosis in patients with long-standing persistent AF (LSPAF) undergoing catheter ablation. METHODS: One hundred and sixteen consecutive patients underwent high density-high resolution voltage mapping of the LA with a multielectrode catheter following PV isolation and restoration of sinus rhythm with cardioversion. A non-invasive dataset, such as clinical variables, two-and three-dimensional echocardiography determined LA size and function and fibrillatory-wave amplitude on a standard surface electrocardiogram were obtained during AF before ablation. RESULTS: Low-voltage areas (LVA; 15 cm² [IQR 8-31]) were detected in 56% of patients. Twenty nine percent of them presented mild, 43% moderate and 28% severe global LVA burden. In univariate analysis, age ≥ 57 years old, female sex, body surface area ≤ 1.76 m², valvular heart disease, moderate mitral regurgitation, chronic coronary syndrome, hypothyroidism, CHA2DS2-VASc score ≥ 3 and ≥ 4 predicted the presence of LVA. In multivariate analysis only female sex, valvular heart disease and CHA2DS2-VASc ≥ 4 remained statistically significant. AF duration, LA size and function and fibrillatory-waves amplitude were neither associated with the prediction of the LVA, nor severe LVA burden. CONCLUSIONS: A LSPAF diagnosis does not indicate the presence of voltage defined fibrosis in many cases. Simple non-invasive screening of the LSPAF population could predict LVA prevalence.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Valve Diseases , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Female , Fibrosis , Heart Atria/diagnostic imaging , Heart Valve Diseases/surgery , Humans , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Treatment Outcome
4.
Sensors (Basel) ; 22(1)2021 Dec 23.
Article in English | MEDLINE | ID: mdl-35009603

ABSTRACT

The possibility of using a smartwatch as a rehabilitation tool to monitor patients' heart rates during exercise has gained the attention of many researchers. This study aimed to evaluate the accuracy and precision of the HR measurement performed by two wrist monitors: the Fitbit Charge 4 and the Xiaomi Mi Band 5. Thirty-one healthy volunteers were asked to perform a stress test on a treadmill. Their heart rates were recorded simultaneously by the wristbands and an electrocardiogram (ECG) at 1 min intervals. The mean absolute error percentage (MAPE), Lin's concordance correlation coefficient (LCCC), and Bland-Altman analysis were calculated to compare the precision and accuracy of heart rate measurements. The estimated validation criteria were MAPE < 10% and LCCC < 0.8. The overall MAPE and LCCC of the Fitbit were 10.19% (±11.79%) and 0.753 (95% CI: 0.717-0.785), respectively. The MAPE and LCCC of the Xiaomi were 6.89% (±9.75) and 0.903 (0.886-0.917), respectively. The precision and accuracy of both devices decreased with the increased exercise intensity. The accuracy of wearable wrist-worn heart rate monitors varies and depends on the intensity of training. Therefore, the decision to use such a device as a heart rate monitor during in-home rehabilitation should be made with caution.


Subject(s)
Fitness Trackers , Heart Rate Determination , Exercise , Exercise Test , Heart Rate , Humans
7.
Kardiol Pol ; 75(3): 221-230, 2017.
Article in English | MEDLINE | ID: mdl-27958616

ABSTRACT

BACKGROUND: Clinical studies in humans have shown the site of atrial stimulation to influence atrioventricular (AV) conduction times and refractory periods, the demonstration of dual AV nodal (AVN) pathways, and induction of AVN reentry. These studies often found conflicting results. Moreover, among enrolled patients a minority of them were found to have AVN reentrant tachycardia (AVNRT). AIM: The purpose of this study was to investigate the effect of right and left atrial pacing on the electrophysiological properties of the AV junction in the typical AVNRT population. METHODS: Ninety-two consecutive patients with typical AVNRT were included. Atrial pacing was performed from the high right atrium (HRA) and the left atrium via the proximal coronary sinus (CS). RESULTS: Stimulation from either the HRA or the CS could result in dual AVN physiology and AVNRT. No site-dependent differences in the ease of induction of dual AVN pathways with variability of initiation from either site were found. However, AVNRT was easier to induce from the HRA. With CS pacing the leftward but not the rightward AVN approaches were the entry point to the AV node because of significantly shorter AH conduction times compared to HRA pacing. Conduction over the leftward AVN extensions could initiate the tachycardia with significantly shorter critical AH interval compared to conduction over the rightward AVN extensions; however, the AH interval during AVNRT and its cycle length were not significantly different. CONCLUSIONS: Rightward and leftward AVN extensions are regular features of the AV node. Their different electrophysiological properties lead to variation in the demonstration of discontinuous AVN conduction and AVNRT during right and left atrial pacing. Despite the observation that the left AVN extensions could compose the entry point to the reentrant circuit, there is no evidence that they constitute the critical component of sustained typical AVNRT.


Subject(s)
Atrioventricular Node/physiopathology , Cardiac Pacing, Artificial , Heart Atria/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Adult , Female , Humans , Male , Middle Aged , Tachycardia, Atrioventricular Nodal Reentry/therapy