Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiovasc Intervent ; 1(1): 19-27, 1998.
Article in English | MEDLINE | ID: mdl-12623410

ABSTRACT

Preliminary experience with primary stenting in myocardial infarction has suggested a greater benefit in clinical outcome than has been obtained with direct balloon angioplasty. However, subacute thrombosis (SAT) remains a limitation for this new mode of therapy. In the BENESTENT II Pilot and main trials, the incidence of SAT with the heparin-coated Palmaz-Schatz stent was only 0.15%. Therefore, as a preamble to a large randomized trial, the feasibility and safety of the use of the Heparin-Coated Palmaz-Schatz trade mark Stent in Acute Myocardial Infarction (AMI) was tested in 101 patients enrolled between April and September 1996 in 18 clinical centres. In 101 stent-eligible AMI patients, as dictated by protocol, a heparin-coated stent was implanted. The primary objectives were to determine the in-hospital incidence of major adverse cardiac events (MACE: death, MI, target lesion revascularization) and bleeding complications, while the secondary objectives were the procedural success rate and the MACE, the restenosis and reocclusion rates at 6.5 months. Stent implantation (n 3 129 stents) was successful in 97 patients of the 101 who were included in this trial. During their hospital stay, two patients died and no patient experienced re-infarction, ischaemia prompting re-PTCA or CABG. Four patients suffered a bleeding complication, three major and one minor, of whom three required surgical repair. At 210 days follow-up, 81% of the patients were event free. At 6.5 months restenosis was documented in 18% of the 88 patients who underwent follow-up angiography, including three total occlusions. The results, both with respect to QCA and the occurrence of MACE, compare favourably with studies using elective stenting in both stable and unstable angina patients. As a result of this pilot study, a large randomized trial comparing direct balloon angioplasty with direct stenting in 900 patients with AMI was initiated in December 1996.

2.
Circulation ; 93(3): 412-22, 1996 Feb 01.
Article in English | MEDLINE | ID: mdl-8565157

ABSTRACT

BACKGROUND: The purpose of the Benestent-II Pilot Study was to evaluate the safety of delaying and eliminating anticoagulant therapy in patients receiving a heparin-coated stent in conjunction with antiplatelet drugs. METHODS AND RESULTS: The study consisted of three initial phases (I, II, III) during which resumption of heparin therapy after sheath removal was progressively deferred by 6, 12, and 36 hours. In phase IV, coumadin and heparin were replaced by 250 mg ticlopidine and 100 mg aspirin. Of the 207 patients with stable angina pectoris and a de novo lesion in whom heparin-coated stent implantation was attempted, implantation was successful in 202 patients (98%). Stent thrombosis did not occur during all four phases, and the overall clinical success rate at discharge was 99%. Bleeding complications requiring blood transfusion or surgery fell from 7.9% in phase I to 5.9%, 4%, and 0% in the three following phases. Hospital stay was 7.4, 6.1, 7.2, and 3.1 days for the consecutive phases. The restenosis rate for the combined four phases was 13% (15% in phase I, 20% in phase II, 11% in phase III, and 6% in phase IV). The overall rate of reintervention for the four phases was 8.9%. At 6 months, 84%, 75%, 94%, and 92% of the patients of phases I to IV, respectively, were event free. For the four phases, the event-free rate was 86%, which compares favorably with the rate observed in the Benestent-I study (80%; relative risk, 0.68 [0.45 to 1.04]). CONCLUSIONS: The implantation of stents coated with polyamine and end-point-attached heparin in stable patients with one significant de novo coronary lesion is well tolerated, is associated with no (sub)acute stent thrombosis, and results in a favorable event-free survival after 6 months.


Subject(s)
Coronary Disease/therapy , Coronary Vessels , Heparin/administration & dosage , Stents , Aspirin/administration & dosage , Coronary Angiography , Coronary Disease/mortality , Disease-Free Survival , Equipment Design , Exercise Test , Female , Follow-Up Studies , Humans , Length of Stay , Male , Middle Aged , Pilot Projects , Safety , Stents/adverse effects , Ticlopidine/administration & dosage , Treatment Outcome , Warfarin/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...