1.
Acta Orthop ; 92(1): 67-73, 2021 02.
Article in English | MEDLINE | ID: mdl-33297800

ABSTRACT

Background and purpose - Modular-neck hip stems have been identified with corrosion-related problems from the neck-stem junction. We report an ongoing varus deformity of modular-neck hip stems with simultaneous metal ion release observed during a study comparing the migration of modular vs. standard hip stems.Patients and methods - We followed 50 patients with modular and 25 with standard neck stems using radiostereometry (RSA). At 5-year follow-up, we noted a compromised integrity of the modular stem with varus deformity in the neck-stem interface. Changes in head-tip distance as well as whole-blood ion concentration and MRI findings were analyzed. The modular stems were followed further up to 8 years.Results - The head-tip distance decreased continuously by 0.15 mm per year resulting in 1.2 (95% CI 1.0-1.4) mm at 8 years for modular stems, while for the standard stems at 5 years, the decrease was 0.09 (CI 0.0-0.2) mm or 0.02 mm/year. For the modular stems, the reduction in head-tip distance correlated to the increase in whole-blood cobalt concentration at 8 years but not to the MRI grading of tissue reactions. At 5 years, cobalt levels were 4.9 µg/L for modular stems and at 8 years 4.8 µg/L, whereas for standard stems this was 1.0 µg/L. After 8 years, 9 of 72 stems had been revised for different reasons, but only 1 with obvious adverse local tissue reaction (ALTR).Interpretation - We present a surprisingly large progressive deformation at the modular neck-stem junction, but so far without a definite clinical problem. Even the femoral head seems to show slight compression onto the taper over time. A high rate of revisions for the modular type of this stem has raised general concerns, and it has been recalled from the market.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Ions/blood , Metals, Heavy/blood , Prosthesis Design , Prosthesis Failure , Titanium/blood , Adult , Aged , Aged, 80 and over , Corrosion , Female , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Male , Middle Aged
2.
Acta Radiol Open ; 9(10): 2058460120964911, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33101707

ABSTRACT

BACKGROUND: Restoration of a correct biomechanical situation after total hip arthroplasty is important. PURPOSE: To evaluate proximal femoral symmetry of acetabular and femoral offset and femoral neck anteversion pre- and postoperatively in hip arthroplasty by semi-automated 3D-CT and to validate the software measurements by inter- and intraobserver agreement calculations. MATERIAL AND METHODS: In low-dose CT on 71 patients before and after unilateral total hip arthroplasty, two observers used a digital 3D templating software to measure acetabular offset, true and functional femoral offset, and femoral neck anteversion. Observer agreements were calculated using intraclass correlation. Hip measurements were compared in each patient and between pre- and postoperative measurements. RESULTS: Preoperatively, acetabular offset (2.4 mm), true (2.2 mm), and functional global offset (2.7 mm) were significantly larger on the osteoarthritic side without side-to-side differences for true and functional femoral offset or femoral neck anteversion. Postoperatively, acetabular offset was significantly smaller on the operated side (2.1 mm) with a concomitantly increased true (2.5 mm) and functional femoral offset (1.5 mm), resulting in symmetric true and functional global offsets. There were no differences in postoperative femoral neck anteversion. Inter- and intraobserver agreements were near-perfect, ranging between 0.92 and 0.98 with narrow confidence intervals (0.77-0.98 to 0.94-0.99). CONCLUSION: Acetabular and concomitantly global offset are generally increased in hip osteoarthritis. Postoperative acetabular offset was reduced, and femoral offset increased to maintain global offset. 3D measurements were reproducible with near-perfect observer agreements. 3D data sets should be used for pre- and postoperative measurements in hip arthroplasty.

3.
J Orthop Surg Res ; 15(1): 225, 2020 Jun 17.
Article in English | MEDLINE | ID: mdl-32552711

ABSTRACT

BACKGROUND: Inferior placement of a femoral stem is predictive for early loosening and failure, but does restoration of the original hip anatomy benefit the function and survival of a total hip replacement? METHODS: Seventy-five patients with primary unilateral hip osteoarthritis operated with an uncemented anatomical stem were randomized for either standard or modular stems. We used 50 ABG II stems with modular necks and 25 standard stems (control group). We measured the symmetry in hip anatomy between healthy and operated side. The anatomical restoration variables were anteversion, global offset, and femoral offset/acetabular offset (FO/AO) quota. We performed measurements using a CT-based 3D templating and measuring software. Migratory behavior of the stems was then measured postoperatively with repeated radiostereometry (RSA) examinations over 5 years. RESULTS: Both stem types showed an early (within 3 months) good stabilization after an initial slight rotation into retroversion and subsidence. There were no significant differences in RSA migration between modular and standard stems. Postoperative anteversion and FO/AO quota had no impact on stem migration. The standard stem tended to result in insufficient global offset (GO), whereas the modular stem did not. CONCLUSIONS: The modular stem gave good symmetrical anatomical restoration and, like the standard version, a benign migratory behavior. Anteversion, GO, and FO/AO quota had no significant impact on stem migration. It therefore seems to be of no importance whether we choose a modular or a standard stem with regard to postoperative stem migration for this stem type. We overestimated the effect anatomical parameters have on stem movement; hence, we believe the study to be underpowered. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01512550. Registered 19 January 2012-retrospectively registered.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/adverse effects , Osteoarthritis, Hip/surgery , Prosthesis Design/adverse effects , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Radiostereometric Analysis , Reoperation , Time Factors , Treatment Outcome
4.
Acta Orthop ; 80(6): 633-8, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19995312

ABSTRACT

BACKGROUND AND PURPOSE: There are rising concerns about the frequency of infection after arthroplasty surgery. Prophylactic antibiotics are an important part of the preventive measures. As their effect is related to the timing of administration, it is important to follow how the routines with preoperative prophylactic antibiotics are working. METHODS: In 114 consecutive cases treated at our own university clinic in Lund during 2008, the time of administration of preoperative prophylactic antibiotic in relation to the start of surgery was recorded from a computerized operation report. In 291 other cases of primary total knee arthroplasty (TKA), randomly selected from the Swedish Knee Arthroplasty Register (SKAR), the type and dose of prophylactic antibiotic as well as the time of administration in relation to the inflation of a tourniquet and to the start of surgery was recorded from anesthetic records. RESULTS: 45% (95% CI: 36-54) of the patients operated in Lund and 57% (CI: 50-64) of the TKAs randomly selected from the SKAR received the preoperative antibiotic 15-45 min before the start of surgery. 53% (CI: 46-61) received antibiotics 15-45 min before inflation of a tourniquet. INTERPRETATION: The inadequate timing of prophylactic antibiotics indicates that the standards of strict antiseptic and aseptic routines in arthroplasty surgery are falling. The use of a simple checklist to ensure the surgical safety may be one way of reducing infections in arthroplasty surgery.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Antibiotic Prophylaxis , Arthroplasty, Replacement, Knee/adverse effects , Prosthesis-Related Infections/prevention & control , Antibiotic Prophylaxis/methods , Antibiotic Prophylaxis/standards , Cefuroxime/administration & dosage , Clindamycin/administration & dosage , Cloxacillin/administration & dosage , Drug Administration Schedule , Drug Resistance, Bacterial , Humans , Injections, Intravenous , Outcome Assessment, Health Care , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/microbiology , Registries , Sweden , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...